Skip to main content
. 2025 Apr 7;15(4):116. doi: 10.3390/membranes15040116

Table 5.

Quality characteristics of treated water by step of treatment, using RO system.

TDS (mg/L) EC (µS/cm) Cl (mg/L)
Input
RO
Output RO Output IEX2 Output IEX3 Input
RO
Output
RO
Output IEX2 Output IEX3 Input RO Output RO Output IEX2 Output IEX3
5000 ± 50 448 ± 2 67.2 ± 5 6 ± 1 6500 ± 50 700 ± 5 40 ± 5 3.3 ± 1 810 ± 10 162 ± 3 24.3 ± 3 2 ± 1