Abstract
Per sensory conflict theory, vestibular sensory information has been proposed to drive motion sickness given deviations from central expectations. However, the consistency of motion sickness with quantitative predictions of manipulated vestibular sensory conflict remains untested. Here, we evaluated motion sickness symptoms within 10 participants exposed to galvanic vestibular stimulation (GVS) designed to manipulate vestibular sensory conflict during passive physical translations. Using a computational methodology, equal and opposite GVS waveforms were designed to reduce (Beneficial) or increase (Detrimental) motion sickness while controlling all other sources of sensory information and central confounds. Beneficial GVS produced a 26% motion sickness reduction, and Detrimental GVS produced a 56% increase (p = 0.0055), demonstrating the causal role of vestibular information in human motion sickness. Validating our predictions, this finding supports the theory that vestibular sensory conflict mediates motion sickness and facilitates new methods and countermeasures for mitigating motion sickness during transportation and in virtual environments.
Subject terms: Neuronal physiology, Biomedical engineering, Aerospace engineering
Aaron Allred and colleagues use Galvanic Vestibular Stimulation to alter motion sickness in humans during motion. Their findings isolate the role of vestibular information in motion sickness, support sensory conflict theory, and provide technological mitigation methods.
Introduction
Motion sickness, most universally characterized by nausea and vomiting, is prevalent among passengers in all forms of human transportation. With the emergence of autonomous vehicles, commercial space travel, and deep space exploration, this condition has once again become a central focus of scientific investigation1,2. Beyond physical transportation, motion sickness is also induced by widely adopted virtual environments3–6, manifesting as simulator sickness and cybersickness. Motion sickness symptoms, ranging from mild discomfort to prolonged incapacitation7, have motivated millennia of theoretical explanations8 and decades of empirical studies and modeling efforts.
For the last half-century, the most prominent theoretical explanation for motion sickness has been sensory conflict theory. Sensory conflict, the difference between ‘sensed’ and the brain’s centrally ‘expected’ measurements, has long been theorized to drive motion sickness9–11. Of the sensory systems that could contribute to motion sickness, it is currently hypothesized that vestibular sensory conflict is a primary driver of motion sickness, particularly sensory conflicts associated with the otolith organs12. Supporting this hypothesis, prior works have found that bilateral reduction in vestibular function (i.e., bilateral vestibular loss) greatly diminishes motion sickness symptom development compared to those with fully functioning vestibular systems13–16. Neurophysiologically, brainstem vestibular only (VO) neurons and cerebellar rostral fastigial nucleus (rFN) neurons have been identified as potential neural correlates of vestibular sensory conflict using monkey models17, the latter of which are modulated by motor commands from cerebellar Purkinje transformations18. Together, these findings highlight how sensory and motor-related information, under the context of sensory conflict theory, may be responsible for modulating motion sickness in primates across environments.
Despite the growing body of evidence supporting sensory conflict theory, conclusive evidence of the role of vestibular information, with control groups for other confounds, in producing motion sickness in humans has remained elusive, and alternative theories have persisted (such as postural control theory19). Empirically, motion sickness symptoms evoked during physical motion stimuli have remained present in patients with bilateral vestibular loss (possibly due to residual vestibular function), while greatly diminished13–16. Most importantly, past experiments examining the role of human vestibular function in producing motion sickness have been observational as vestibular function in these studies was not directly manipulated by experimenters, and results from participants with vestibulopathy are confounded by heterogeneous peripheral damage as well as compensatory central processing between groups following a reduction in vestibular function15. Neuronally, while VO and rFN neurons fire analogously to the proposed vestibular sensory conflict construct, it remains unknown whether (or how) these neurons project to pathways that drive motion sickness17, and they have yet to be examined in humans. Consequently, the causal role of vestibular sensory information in humans has not been deduced as no study to date has yet isolated the role of the vestibular system in producing motion sickness, controlling for alterations to other sensory information or central compensation following altered vestibular information.
A popular tool for altering vestibular sensory information in humans, galvanic vestibular stimulation (GVS) offers a prospective means of isolating the role of the vestibular system in producing motion sickness. GVS is a transcutaneous electrical stimulation, most commonly applied via electrodes on the mastoid processes (i.e., binaural GVS)20, that affects the firing rates of the afferent vestibular neurons within cranial nerve viii. A number of studies have pursued using GVS to reduce motion sickness either through a theorized central down-weighting of vestibular sensory information21 or through a theorized reduction of inter-modality conflict22,23, contrasting the intra-modality conflicts associated with sensory conflict theory11. In the case of the former, the addition of large amplitude (1.75 mA) noisy GVS has briefly reduced symptom severity21. In the case of the latter, GVS current was coupled to virtual, visual rotations (i.e., GVS current was proportional to the angular velocity of the visual scene’s motion) to reduce sickness symptoms. Crucially, neither of these GVS studies assessed reducing motion sickness during provocative physical motions, but they demonstrated the promising utility of GVS. However, without a quantitative means of manipulating vestibular sensory information with GVS in a manner predicted to reduce vestibular sensory conflict thus motion sickness, sensory conflict theory has not been directly assessed or leveraged to develop GVS-based countermeasures.
In the last year, a series of models, each validated using data from human participants, have emerged to enable methodologically altering vestibular stimulation to probe the role of vestibular sensory information and sensory conflict theory with GVS. First, a quantitative model that captures the dual influence of physical motion and GVS current (which primarily affects net semicircular canal signals) on human spatial orientation perception was developed24. This model combines GVS-evoked changes in vestibular afferent firing rates25,26 with an observer model of spatial orientation perception27–29. In the observer model, peripheral vestibular sensory information from head motions is computationally simulated to produce predicted spatial orientation perceptions through internal models of sensory dynamics and kinematic relationships30–32. In the model, peripheral and centrally predicted afferences are compared to compute quantitative vestibular sensory conflicts resulting from GVS and physical motion. Second, a computational model of motion sickness dynamics was produced. This model predicts motion sickness symptoms from semicircular canal and otolith-associated sensory conflicts from spatial orientation perception during passive motions in the dark12. In combination, these models enable predicting how GVS-altered vestibular information during a physical motion profile can alter vestibular sensory conflicts and motion sickness symptoms. Further, if motion sickness symptoms can be systematically altered by GVS, then GVS may be suitable as a means of countering motion sickness during physical motion.
Here, we utilize these newly developed models to generate a Beneficial GVS waveform using the binaural bipolar GVS montage (Fig. 1b; see Methods) hypothesized to reduce motion sickness during pseudorandom whole-body lateral translations (i.e., Earth-horizontal along the interaural axis) in the dark over forty minutes of continuous motion. Further, to preclude confounds of a placebo, we assess the effects of a complementary Detrimental GVS waveform hypothesized to increase motion sickness compared to the Beneficial GVS condition. The Detrimental GVS waveform maintains the same characteristics (e.g., frequency content, time delay, amplitudes) as the Beneficial GVS waveform but is polarity (left/right anode/cathode) mirrored. Implementing this design, we measured motion sickness in healthy human participants in the presence of a provocative physical motion paradigm (Fig. 1a). The effects of each condition were hypothesized a priori to systematically produce differing motion sickness symptoms during 40 min of motion and 30 min of recovery via the alteration of vestibular sensory conflict (Fig. 1b–e).
Fig. 1. Experimental results demonstrating an alteration of motion sickness symptoms over time via GVS.
a Experimental conditions given to each participant. b The lateral translation sum-of-sines profile given to participants, with a period of 40 s, as well as the GVS current profile provided during the Beneficial GVS condition. Each condition results in differing perceptions of the GIF vector, which in turn alters the sensory conflicts. Here and throughout, a head-centered right-handed coordinate system is used, where the y-axis is the interaural axis, positive out the left ear, and the x-axis is the naso-occipital axis, positive out the nose. Positive GVS corresponds to right anode and left cathode electrical stimulation. c Each condition produces altered vestibular sensory conflicts, predicted from an observer model of self-orientation and self-motion perception via augmentation of canal rotational afferent signals. d Vestibular sensory conflicts are fed through a model of motion sickness dynamics to produce temporal predictions of motion sickness severity for each condition. e Motion predictions and empirically assessed motion sickness symptoms over time (N = 10), where shaded regions correspond to the empirical standard error of the mean. Plots throughout this article use the same Beneficial GVS (green), No GVS (blue), and Detrimental GVS (red) color code.
Results
Motion sickness symptom severity in humans depends on vestibular sensory information
We empirically measured the motion sickness dynamics during GVS and passive whole-body lateral translations composed of frequencies between 0.275 and 0.325 Hz in the dark (Fig. 1a, e). Our experimental results first revealed differences in motion sickness, dependent on the GVS condition provided, confirming our hypothesis that vestibular sensory information alters motion sickness symptom severity. Using the rate of motion sickness (MISC rate per minute), a sensitive measure of symptom progression over time33, a hierarchical linear regression model (with random effect intercepts for each subject) revealed a significant linear effect of the gain supplied to the GVS current (1 for Beneficial GVS, 0 for Baseline/sham, −1 for Detrimental GVS) (t(28) = −3.00; p = 0.0055; = −0.024 MISC per minute/GVS gain; Fig. 2). Utilizing our computational model of motion sickness prior to the experiment, we hypothesized a negative slope as we predicted less motion sickness development for Beneficial GVS and more for Detrimental GVS. This affirming, significant result indicates that altered vestibular information administered via GVS can be utilized as a means to systematically decrease and increase motion sickness severity. Further, it does so in a manner consistent with that predicted by our computational model that utilizes vestibular sensory conflict to drive motion sickness symptoms over time (Fig. 1e).
Fig. 2. A linear relationship exists between experimental conditions.

As the current polarity gain (−1,0, and 1) increases (i.e., goes from Detrimental to No to Beneficial GVS), the MISC rate decreases, as hypothesized. The black line is plotted using the slope and intercept of the fixed effect of the hierarchical linear regression model. Individual markers are consistent across conditions and figures. Participant identifiers (individual shapes; N = 10) are consistent throughout the figures in this article. The Beneficial GVS condition produced the lowest MISC rate (μ = 0.035; CI = [0.0056 0.064]) compared to the No GVS (μ = 0.048; CI = [0.016 0.080]) and Detrimental GVS (μ = 0.083; CI = [0.040 0.13]) conditions. A hierarchical linear regression model (with random effect intercepts for each subject) revealed a significant linear relationship between the gain supplied to the GVS current for each of our three GVS Conditions (t(28) = −3.00; p = 0.0055; β = −0.024). Comparing the Beneficial GVS to the No GVS directly, we did not find a significant difference (t(9) = −1.1; padj = 0.3; d = 0.292), while a significant difference was found between the Beneficial and Detrimental GVS conditions (t(9) = −2.39; padj = 0.04; d = 0.92).
Sensory conflict theory explains differences in motion sickness
A computational examination of the sensory conflict produced in each experimental condition offers insight into why the application of our Beneficial GVS waveform produced decreased motion sickness compared to the Detrimental GVS waveform. Feeding our experimental conditions through a validated, quantifiable model of human perception during passive motions in the dark (i.e., the observer model27–29), we found decreases in the vestibular sensory conflict terms associated with both the canals and the otoliths (Fig. 1b, c). These reductions in the magnitudes of vestibular sensory conflict, primarily the conflict terms associated with the otolith organs (in conjunction with the motion sickness model dynamics), explain how GVS achieves a reduction of motion sickness during the Beneficial GVS waveform. Conversely, an increase in the magnitude of these terms explains why GVS increases motion sickness during the Detrimental condition.
Notably, the physical motion profile (Fig. 1b) utilized to induce a physical motion sickness stimulus across all three experimental conditions was composed of lateral, Earth-horizontal translations, which only physically stimulates the otolith organs. Conversely, GVS is estimated to primarily alter net signals of angular velocity and not net signals transduced by systems of otolith afferents34, as is approximated in the model we apply here24. Both the Beneficial and Detrimental GVS conditions provide the same (but opposite) alteration in stimulation to the semicircular canals via GVS. However, the Beneficial GVS condition is predicted to reduce sensory conflict terms associated with the semicircular canals and otolith organs (Fig. 1c). This is due to the influence of semicircular canal transduction on central expectations of both semicircular canal and otolith measurements. In the case of the latter, canal cues are known to influence otolith expectations through known spatial orientation perception pathways for disambiguating tilt and translation from gravito-inertial force (GIF)30,35. Alternatively, the Detrimental GVS waveform increases sensory conflict terms associated with both sets of vestibular organs (Fig. 1c). Ultimately, alterations in motion sickness between conditions are predicted to be achieved by systematically altering sensory conflict terms with GVS, both those associated with the canals and otolith organs (Fig. 1d, e)12.
Galvanic vestibular stimulation as a countermeasure to motion sickness
In evaluating differences in motion sickness symptom severity across experimental conditions, we found that the Beneficial GVS condition produced the lowest MISC rate (= 0.035; 95% CI = [0.0056 0.064]) compared to the No GVS (= 0.048; CI = [0.016 0.080]) and Detrimental GVS (= 0.083; CI = [0.040 0.13]) conditions. Prior to conducting the experiment, our motion sickness model predicted a reduction in MISC for the Beneficial GVS condition of 22% after 40 min of motion; empirically, we observed a mean benefit of 26%. We also predicted an increase in MISC of 23% for the Detrimental condition following 40 min of motion; we observed a mean detriment of 56%. Further, the significant negative slope (p = 0.0055; = −0.024) found from our linear mixed-effect model demonstrates GVS’s potential utility as a countermeasure to motion sickness.
Exploring our hypothesis that GVS can be utilized as a countermeasure to motion sickness further, we utilized a follow-up two-tailed t-test to assess the difference in motion sickness between the Beneficial GVS condition and the baseline, No GVS condition. Comparing the Beneficial GVS to the No GVS directly, with a Bonferroni correction for multiple comparisons, we did not find a significant difference (t(9) = −1.1; padj = 0.3; d = 0.29; Fig. 2). A difference was found between the Beneficial GVS and Detrimental GVS conditions (t(9) = −2.39; padj = 0.04; d = 0.92; Fig. 2).
Individual perceptual susceptibility to GVS is predicted to alter motion sickness outcomes
Next, we asked to what extent interindividual variability to GVS susceptibility may explain differences in the effects of the Beneficial and Detrimental GVS waveforms. Population mean models of GVS’s influence on spatial orientation perception and motion sickness were utilized to derive the optimal GVS waveform utilized in this study12,24, and individual differences in GVS susceptibility may lead to diminished effects of these waveforms. To assess the influence of interindividual variability, we simulated a range of estimated GVS susceptibility factors calculated from human participants in a previous study (N = 11; 6 female)24. These individual GVS susceptibility factors were calculated as a gain on GVS’s impact on canal firing rate (such that a gain of zero indicates no effect of GVS) by fitting this gain to individual perceptual reports of self-orientation during applied binaural bipolar GVS stimulation. Propagating this range of individual susceptibility factors (Fig. 3a) through the observer model (Fig. 3b) for the experimental paradigm utilized in this study, we calculated a predicted range of percent decreases in MISC from baseline for the Beneficial and Detrimental GVS waveforms (Fig. 3c). This approach approximates a control for individual susceptibility to motion sickness by computing effects as a percentage from their predicted baseline.
Fig. 3. We compare model predictions of Beneficial and Detrimental waveform changes in MISC from the No GVS case to changes from individuals’ baseline MISC rates observed in this study.
a Model predictions are cast across a distribution of individual GVS susceptibility factors found from a separate study (N = 11) in humans24 (the range of GVS susceptibility factors is denoted with the gray region). Individual GVS susceptibility is computed using psychometric task reports of orientation perception. b This distribution of GVS susceptibility factors is modeled during the Beneficial and Detrimental GVS waveforms and lateral physical motion profile used in this study to produce temporal MISC predictions. Specifically, the individual susceptibility to GVS application is modeled as a gain on incoming GVS current as it alters canal afferent signals. c Predicted decreases in final MISC as a percentage (and absolute change in MISC rate) from the baseline after 40 min of simulated translational motion are plotted against Individual GVS susceptibility. The more susceptible to GVS, the larger the benefits and detriments are predicted to be for the range of susceptibility factors (gray region), computed using a separate sample of participants. The mean effect across the participants (using a susceptibility factor = 1) is starred. d Empirical decreases in MISC rate for the separate sample of participants (N = 10), whose data was collected in this study. Beneficial and Detrimental GVS conditions are consistent with the model predictions (Fig. 4c) formulated based on a separate sample of participants. e Individual average effects across both conditions, directionally pooled together, are also computed. Together (d, e) demonstrate consistent directional effects of GVS on MISC rate across both conditions.
Our computational predictions reveal that the Beneficial and Detrimental GVS waveforms should consistently produce beneficial and detrimental effects across an expected range of individual susceptibility to GVS. Within this range, increased susceptibility should yield more benefit/detriment and vice versa. For very GVS-susceptible individuals (beyond ~6 the average susceptibility), notably the Beneficial GVS is predicted to become detrimental, resulting in increased motion sickness. While we did not encounter any individuals with a much greater than average GVS-susceptibility in our previous experiment, this analysis suggests that the amplitude of the Beneficial waveform should be reduced in order to reduce motion sickness for these individuals. These predictions suggest that our findings have population validity, given inter-individual susceptibility to GVS variability.
With these predictions, we next assess the consistency of the Beneficial and Detrimental GVS waveforms on decreasing/increasing MISC rate in our separate participant sample collected in this study (N = 10; 5 female). Individual changes in MISC rate from their MISC rate reported during the baseline, No GVS condition (Fig. 3d) revealed consistent decreases in MISC rate for the Beneficial GVS condition (interquartile range of Beneficial GVS compared to No GVS ≥ 0) and consistent increases in MISC rate for the Detrimental GVS condition (interquartile range ≤ 0). Further, the Beneficial GVS decreases were significantly more than Detrimental GVS (t(9) = −2.37; p = 0.021; d = 1.00). To assess the consistency of the average effect of GVS across participants, we computed the average effect difference between their Beneficial and Detrimental conditions (Fig. 3e). This comparison reinforces that Beneficial GVS consistently decreased MISC rate and Detrimental GVS consistently increased MISC rate from each subject’s baseline, No GVS condition. Altogether, these computational predictions and accompanying statistical analyses show that applying a single GVS coupling waveform defined by the model with an average GVS-susceptibility can systematically impact motion sickness despite individual differences in susceptibility to GVS.
Beneficial GVS produces reduced MISC symptoms over time
Finally, we asked to what extent GVS influences different MISC outcome levels. We provide individual subject response curves (Fig. 4a) and examine the time to different MISC reports in the study (0–7 and recovery) for each of the three conditions (Fig. 4b, c). On average, we find that the Beneficial GVS waveform condition resulted in more uneasiness (MISC 1) than the other two experimental conditions, including the Detrimental GVS waveform. In simulating the different tilt and translation perceptual responses using the observer model, which may contribute to this feeling of uneasiness, we found the Beneficial GVS condition evokes smaller perceptions of translation and roughly equal perceptions of tilt. Thus, it produces a larger ratio of tilt to translation than the other conditions (tilt perceptions shown in Fig. 1b). While the Beneficial GVS waveform was designed to reduce motion sickness (Methods), these resulting altered perceptions may have contributed to these reports of uneasiness during the Beneficial GVS condition.
Fig. 4. An evaluation of individual participant MISC reports.
a Individual participant MISC dynamics across all three conditions (N = 10; with the symbol makers denoting which subject is shown in each subpanel). b A depiction of an example time to MISC value and time to recovery (final MISC) calculations. c Time to different MISC values for all three conditions. The Beneficial GVS condition showed larger (i.e., longer) times to reach MISC values of 2 (‘vague’ dizziness, warmth, headache, stomach awareness, sweating), 3 (‘slight’), 4 (‘fair’), 5 (‘severe’), as visualized by higher green (Beneficial GVS) box plots than blue (No GVS) or red (Detrimental). In contrast, time to MISC equals one (‘uneasiness’) tended to be shorter for Beneficial GVS, which may be attributed to larger tilt perceptions vs. translations perceptions in the Beneficial GVS condition.
Considering motion sickness symptoms beyond uneasiness (MISC 2 and on), the Beneficial GVS condition produces longer times to each level of sickness than the other conditions on average, indicating reduced motion sickness symptoms beyond uneasiness. Complementing our previous results evaluating MISC rate, the Detrimental GVS condition produced the shortest times to each MISC value on average (indicating higher motion sickness). In the forty minutes of motion exposure, the Beneficial GVS condition never produced a MISC larger than 5 (i.e., never produced symptoms of slight nausea using MISC reports, which starts at 6). In comparison, the No GVS condition produced a MISC of 6 in one participant, and the Detrimental GVS waveform produced a MISC of 6 in two participants as well as a MISC of 7 in one participant that required the only early termination of motion (at minute 39).
Discussion
In finding that motion sickness is modulated by equal and opposite applications of GVS during a consistent physical motion profile with all other sensory cues controlled for, we find that vestibular sensory information in isolation, modulated by GVS, contributes to motion sickness in humans. Further, because our empirical results trend in the same direction as predicted by our model of motion sickness driven by vestibular sensory conflict, our results indicate that vestibular sensory conflict (produced by altering incoming vestibular information and subsequent central processing) is likely also a causal driver of motion sickness as a mediator of vestibular sensory information. While the role of vestibular sensory conflict has long been suspected9–11, it has never been empirically evaluated. Until now, no means of manipulating vestibular stimulation in a manner predictive of quantitatively altering sensory conflict to alter motion sickness has been enacted.
Reduced motion sickness during the Beneficial GVS waveform compared to the Detrimental GVS waveform can be explained via a reduction in vestibular sensory conflict. In particular, the conflict terms associated with the otolith organs could be reduced with the Beneficial GVS waveform. Counterintuitively, a reduction of these otolith conflict terms is predicted (Fig. 1c) despite GVS only altering the net signal transduction of the canals in the model and the physical motion profile only stimulating the otolith organs. In our model of central processing27, the canal signals impact internal perceptions of angular velocity, which in turn influence the perceived GIF through the GIF resolution hypothesis (Fig. 1a, b). Here, it is thought that the CNS uses internal models of kinematics in conjunction with perceived angular rotation to separate tilt from translation35,36 with neural mechanisms located in Nodulus and Uvula lobules of the cerebellar vermis30.
Concerning the neurophysiology of vestibular sensory conflict, our results support the likely role of both VO neurons in the brainstem’s vestibular nuclei and rFN neurons of the deep cerebellar nuclei in producing motion sickness17, which fire analogously to sensory conflict terms for rotations and translations37–39, encoding responses during passive motions yet demonstrating reduced responses (i.e., reafference cancellation) during active motion, the latter likely due to accurate forward model predications projected by anterior cerebellar vermis Purkinje cells18,40. While not explored here, vestibular sensory conflict as a causal driver of motion sickness explains the lack of motion sickness during coordinated active motions, where the vestibular consequences of motion are anticipated, as highlighted by Oman and Cullen17. This idea was computationally implemented by Laurens and Angelaki40 for a reduced degree-of-freedom Kalman filter modeling implementation of the observer model. They showed that vestibular sensory conflict is not present during active motions where the vestibular consequences of self-generated motion are perfectly predicted by the central nervous system. Taken together with our results, a causal relationship between these neural correlates and motion sickness is deemed increasingly likely. Alternatively, similar functioning neural correlates that project to motion sickness centers are likely to exist somewhere in the brain.
Regarding human spaceflight, where the hazard of emesis from motion sickness drives operational schedules, our finding that vestibular information modulated by GVS drives motion sickness lends empirical evidence to the vestibular reinterpretation hypothesis41,42 as a driver of motion sickness through the production of vestibular sensory conflict as well. In this theory, vestibular sensory conflict is predicted to be a byproduct of a maladapted state of centrally processing vestibular sensory cues following a gravity transition. Similarly to how vestibular sensory conflict is present during unrealized attempts at head movements in the rhesus macaque43, the vestibular reinterpretation hypotheses can be framed as improper internal model predictions (e.g., such as those following a gravity transition), which do not match actual vestibular afference. Furthermore, reports of worsened motion sickness experienced by astronauts during active head movements44 can be framed as an additional consequence of inappropriate reafference cancellation via maladapted forward models, which worsen vestibular sensory conflict until sensory adaptation is completed. These results lay the foundation for quantitatively exploring non-pharmaceutical, technological countermeasures to motion sickness in astronauts by establishing a holistic understanding of how vestibular information and sensory conflict broadly drives motion sickness. Our methods enable future efforts to design and evaluate beneficial GVS waveforms for spaceflight applications following the transition from Earth to microgravity. Following central adaptation to gravity, the computational methodology provided here, specifically the central observer model of spatial orientation perception, will require modification to capture the time course of central adaptation to reflect updated neural circuits in humans (see current modeling efforts45–48).
In evaluating GVS as a countermeasure to motion sickness, we found GVS to reduce motion sickness symptoms on average compared to the control condition, but we did not reach statistical significance (padj = 0.3). While the trend is in the hypothesized direction, the lack of significance is unsurprising given the population mean effect predicted by the model (a decrease in MISC of 23% after 40 min of motion). Conducting a post-hoc power analysis to determine how many participants would be needed to find significance at the current effect size, we would likely need to examine more than 100 participants to reach significance. Further, the statistically significant difference between the Beneficial GVS condition and the Detrimental GVS condition is afforded by the additional statistical power available from the larger effect size (where we only require seven participants according to a post-hoc power analysis, with ten tested in our study). A limitation in our ability to examine the full benefit of GVS stems from the inability to implement a sufficiently sickening baseline, No GVS condition using our Tilt Translation Sled (TTS) motion device. Ideally, our baseline motion stimulus would have been of higher amplitude thus more nauseogenic, but the physical motion profile implemented here reached the upper capability of our motion device, which was restricted in both translational velocity and acceleration. This limitation explains why we observed larger detrimental effects than beneficial effects of GVS since there was more opportunity for motion sickness to worsen from the relatively benign baseline, No GVS condition. However, if the baseline physical motion had been too nauseogenic, then we may not have been able to observe the full detrimental effect of GVS. While our simple comparison between the No GVS and GVS conditions was not significant, the trend towards a decrease in MISC on a population level (as well as the significant negative linear effect between all three conditions) provides an indication that GVS can be utilized to reduce motion sickness symptoms on average for the population. Our experimental results encourage GVS-based solutions (as well as other technological means of reducing vestibular sensory conflict) be explored on a larger scale as a means of mitigating motion sickness and making provocative scenarios less nauseogenic.
The finding that motion sickness is altered between our two GVS conditions, while controlling for the physical motion, posture, and all other sensory cues, provides evidence that is inconsistent with postural control theory19 (as it has been proposed as an alternative, mutually exclusive theory of motion sickness49). Specifically, as formulated by Riccio and Stoffregen, postural control theory19 claims that sensory conflict on the level of a single sensory system is an improper evaluation of central processing of patterns of sensory information and postulates that sensory conflict does not exist. Furthermore, they define posture as the configuration of the body and its segments, and postural control as the coordinated stabilization of the body and its segments. Because we experimentally control for both posture, postural control, and all other sensory cues across experimental conditions, our empirical findings are incompatible with postural control theory as a comprehensive explanation for motion sickness. While our controlled experimental outcome does not prove vestibular stimulation to be the only contributor to the development of motion sickness (i.e., it is sufficient but may not be necessary), postural control theory rejects all other contributors to motion sickness outside inadequate postural control, which is determined by holistic patterns of sensory information beyond just the vestibular system.
As a final contribution, the computational methodology provided here to produce the Beneficial GVS waveform (Fig. 5; see Methods) provides a means of generating GVS waveforms to achieve specific desired outcomes within the operating capabilities of binaural bipolar GVS. Thus far, no known application of GVS has been developed for use during lateral translations, and no application of GVS has utilized models of spatial orientation or motion sickness to make a priori predictions. By combining models of GVS’s influence on spatial orientation perception and a model of how sensory conflicts involved with processing spatial orientation then produce motion sickness (nested within an optimization scheme), this methodology allowed us to generate a non-intuitive solution to alter motion sickness during lateral translations. Furthermore, our empirical results, assessed in a separate cohort of participants, validate the efficacy of this approach, opening the door to future applications where GVS is designed to reduce motion sickness (or alter/rectify self-motion and self-orientation percepts) across different situations.
Fig. 5. Methodology used to generate the desired GVS waveforms.
a The GVS waveform can be described by coupling to physical motion characteristics in the GVS plane, which is tilted with respect to the frontal plane24,34. These motion characteristics, GIF angle (), rate-of-change of GIF (), head roll angle (), and head roll angular velocity (), were chosen to describe the GVS waveform for two reasons. First, GVS primarily affects signals of rotation, and each of these characteristics describes either a rotation angle or angular velocity associated with vestibular stimulation. The chosen set of motion characteristics captures all situations of motion-producing vestibular stimulation. Secondly, each of these motion characteristics lies in the plane of rotation that binaural bipolar GVS signals where GVS can be expected to alter spatial orientation perception, sensory conflict, and motion sickness. b To determine the optimal GVS waveform using a set of weights and a time delay on these characteristics, the two-stage model of (1) GVS influencing spatial orientation perception24, producing sensory conflicts, and (2) weighting of sensory conflicts from spatial orientation perception to produce MISC symptom dynamics12 was nesting inside an optimizing scheme that sought to reduce MISC at the end of 40 min of motion (the scalar objective function).
Notably, GVS remains limited in its ability to reduce motion sickness in its entirety, regardless of potential other sources that drive motion sickness. First, GVS is inherently limited by the amplitude of electrical current that can comfortably be applied to the skin, and side effects of applying GVS current (visual flashes, metallic taste, etc.) generally increase with larger current amplitudes. With the dynamic waveform used in this study, only discomfort at the electrode sites (which can be resolved with local anesthetics at the electrode site if desired) and metallic tastes were reported by participants. Additionally, the binaural bipolar GVS montage is only capable of stimulating a single degree of vestibular, semicircular canal sensation. It is thus limited in its utility as a countermeasure for altering physical motions not in the frontal plane (e.g., fore-aft translations and pitch tilt). Additionally, it is unlikely that GVS will be beneficial in countering sensory conflict in order to reduce motion sickness resulting from Earth-vertical components of motion50. However, this effort provides a methodological means of computationally designing and empirically evaluating the efficacy of other GVS montages, such as those that tend to act in the sagittal plane23,51.
Methods
Study approval and participant recruitment
This study was approved by the Institutional Review Board of the University of Colorado, Boulder (Protocol 23-0413). Ten participants (mean age: 27; SD = 3.9; 5 female) took part in this study, all of which partook in all three conditions (Beneficial, Detrimental, and No GVS), in a counterbalanced order. Participants reported no known history of vestibular dysfunction and refrained from consuming alcohol within 6 h prior to the study. Participants were between the heights of 5’2” and 6’3” and weighed less than 225 lbs. as required by the motion device used in the study.
Motion sickness experimental protocol
Participants were outfitted with a 2 × 2” square sponge electrode on each mastoid, held in place with a headband for all conditions (including the No GVS Baseline condition as a sham). Impedance between the two electrodes was checked and found to be below 10 kΩ for all participants. During the first visit, participants received 12 s duration sinusoidal GVS waveforms, of 0.01, 2, and 4 mA while seated on a stool with their feet dangling, back unsupported, arms crossed, and eyes closed to familiarize themselves with GVS and ensure comfort during stimulation. For the experiment, participants sat upright in the TTS, a motion device capable of providing combinations of tilt and translation, with their heads restrained upright by firm foam blocks on each side, which were adjusted to fit the participant’s head. Participants were constrained to the chair by a five-point harness, with arms and legs supported by rigid feet and armrests attached to the chair, located inside a closed chassis that translated along the track. The lights were off to remove visual cues, and white noise was provided in earbuds to help mask auditory cues from the device’s motors.
During motion, participants remained upright (i.e., were not tilted) and were linearly translated along their interaural axis (Earth-horizontal) via a pseudorandom sum of sines profile (Fig. 1a, b) for up to 40 min. This lateral translation profile was comprised of low-frequency (0.275, 0.3, and 0.325 Hz) sine waves, and the sum-of-sines translation profile had a peak acceleration/deceleration of ±1.78 m/s2, velocity of ±0.95 m/s, translation of ±0.5 m, and repeating period of 40 s. These motion characteristics were selected to be within the operating bounds of the TTS (particularly for translational velocity and acceleration). A pseudorandom motion profile was selected over a sinusoidal motion profile in order to reduce the potential effects of repeated motion, where participants may be able to anticipate future motions of a repeating single-frequency sine wave motion. Lastly, a lateral translation profile was selected (rather than including roll rotations) to test the hypothesis that lateral translation-inducing motion sickness, where physical motion stimulates only the otoliths, can be altered by GVS, which primarily (and essentially only) influences the semicircular canals. This test provided the opportunity to comprehensively evaluate our understanding of sensory conflict theory and the role of spatial orientation perception in producing motion sickness. Further, lateral translations provided our experiment with an additional degree of ecological validity as lateral translations are experienced in cars, and new patterns of otolith stimulation are experienced during spaceflight, both of which contribute to motion sickness. The same physical motion was administered during all three GVS conditions (described below).
To capture the dynamics of their motion sickness symptoms, before (t = 0), during, and following motion (i.e., recovery), participants continuously reported their motion sickness symptoms using the commonly utilized MISC52 (anchored 0–10 levels; Fig. 4c lists the descriptors associated with levels 1–7, as no subjects reported levels 8–10 before motion was stopped), and this scale has been found to monotonically increase with discomfort during provocative stimulation53. An additional motivation to use the MISC scale is that it is congruent with our computational model output12. Additionally, general discomfort and nausea (on scales of none, slight moderate, and severe) were queried every one minute to further monitor participant comfort and stopping criteria. Two consecutive verbal reports of “moderate nausea” or two consecutive verbal reports of a 7 on the MISC were set a priori as our stopping criterion. These stopping criterion was only reached for one participant, who had an early termination of motion after 39 min of the nominal 40 min of motion during the Detrimental GVS condition. Two-way audio communication and one-way infrared video allowed operators to monitor subjects in the dark. Following the up to 40 min of passive motion, motion sickness reports continued during 30 min of stationary recovery, seated with eyes open in a chair outside the TTS.
Experimental paradigms
Participants (N = 10; 5 female) were randomly assigned in a counterbalanced order to one of the three experimental conditions per visit: No GVS, Beneficial GVS, and Detrimental GVS. To avoid experimental confounds (such as placebo effects) presented by using a No GVS control condition or a different GVS waveform as a sham, the Detrimental GVS waveform was added as a third condition to our experiment in addition to the No GVS condition. The Detrimental GVS condition was identical to the Beneficial GVS waveform, applied with mirrored polarity to the Beneficial GVS current waveform (i.e., reversed polarity electrodes), and predicted to increase motion sickness symptom severity. This approach allowed us to control all other variables between the treatment and sham conditions, keeping the waveform characteristics (e.g., frequency content, time delay, and amplitudes) the same between the two GVS conditions. As a result, the single independent variable between these two conditions is incoming vestibular information alone, modulated by identical GVS waveforms (just with opposite polarity), applied during the exact same physical motion. For the Beneficial and Detrimental conditions, GVS current was applied during the motion phase only, and our GVS device was programmed to start temporally synced to motion as displayed in Fig. 1b. Our GVS device was pre-programmed with the current waveform to enable this sync.
We implemented a within-participants experimental design where each participant experienced each condition over the course of three separate visits (30 total test sessions). Testing within participant groups helps address several statistical complications due to interindividual differences. First, motion sickness is reported subjectively, and interindividual differences in understanding and reporting motion sickness severity using motion sickness scales are expected. Second, there are large interindividual differences in motion sickness susceptibility7,54. Recently in the literature, habituation to repeated motions has been mitigated by spacing testing sessions within participants by at least one week33. Here, each condition was also separated by at least one week (mean: 25 days). A Friedman test of session order revealed no significant effect on MISC rate (p = 0.8).
The GVS waveform administered during the Beneficial GVS condition was predicted to reduce motion sickness during the physical motion profile by nesting simulations of the combined GVS and motion sickness model within an optimization loop (Fig. 5). The first stage of the model enabled quantitatively predicting vestibular sensory conflicts in humans as intermediates of spatial orientation perception during applied passive physical motion and binaural bipolar GVS current24. The second stage of the model weighed vestibular sensory conflicts, both those associated with semicircular canals and otolith organs, to produce MISC symptoms12. The associated weights were trained and validated in a previous study by simulating several passive motion paradigms in the dark with human participant motion sickness reports over time. During the optimization routine, the scalar objective function that was minimized was the predicted MISC after 40 min of the lateral translation motion profile provided to the participants in this study. The optimization variables were weights associated with the GVS current being coupled to a weighted linear combination of physical motion characteristics in the head reference frame (Fig. 5a), including the GIF angle, the time rate of change of the GIF angle, as well as a time delay in the GVS plane. Within the optimization loop, current values above an absolute magnitude of 5 mA were capped at 5 mA to produce current waveforms that would be tolerated by subjects. MATLAB’s fmincon function was utilized to determine the optimal physical motion characteristic coupling. In addition to the results presented herein, this methodology for devising a countermeasure to motion sickness (Fig. 5b) via computational models represents a scientific contribution that can also be utilized to produce GVS waveforms that are predicted to systematically alter spatial orientation perceptions55.
The optimized Beneficial GVS waveform, depicted in Fig. 1b, was proportional to the lateral velocity of the head along the interaural axis. During the dynamic motion frequencies used here, this waveform (coupling factor of 12.7 mA/(m/s)) is tantamount to coupling to the time rate of change of the GIF angle (with a coupling factor of −0.84 mA/(deg/s)) of the head over time given the small GIF angles present in the motion profile. This latter, more robust coupling scheme was developed by enhancing early optimization schemes by modifying the optimization parameters to include a weight/optimization variable on the time rate of change of the GIF rather than the lateral velocity. While these are essentially equivalent (and produce the same model prediction changes in MISC from the baseline simulation without GVS), we encourage researchers to couple applied GVS to the time rate of change of the GIF angle of the head over time for other applications seeking to reduce motion sickness during lateral Earth-horizontal translations experienced along the interaural axis. This physical motion characteristic is robust to prolonged translational velocities, which do not simulate the vestibular system and GVS is likely not needed or beneficial. The translational velocity coupling waveform was used for empirical evaluation and to formulate model predictions throughout this article. Additionally, we provide a means of optimizing/designing any arbitrary GVS waveform that is not coupled to a physical motion characteristic using temporally spaced and splined nodes as optimization variables. This routine and code are included in the linked repository (as well as a comprehensive guide to its construction and implementation56).
Following generating a Beneficial GVS waveform, the Detrimental GVS waveform administered was the polarity-mirrored counterpart to the Beneficial GVS waveform. A priori, the Beneficial GVS waveform was predicted to decrease motion sickness by 22%, and the Detrimental GVS waveform was predicted to increase motion sickness by 23% compared to baseline for the population on average using MISC. A No GVS condition was conducted as a measure of baseline motion sickness without any GVS current applied. However, electrodes were still applied, and participants remained blind to the experimental condition.
Previous studies that have examined GVS as a countermeasure to motion and cybersickness have encountered several notable obstacles. The first is the lack of an obvious sham condition when examining the effects of GVS. In prior experiments, the control condition has simply been only the application of ‘No GVS’21–23, in which case participants are likely not blind to the experimental conditions and can likely identify the treatment group given obvious GVS-induced tactile sensations. Further, known side effects of GVS (e.g., tactile sensations, visual flashes, etc.) are confounds in assessing the causal aspects of GVS as a countermeasure, thus the impact of GVS on the vestibular sense alone cannot be isolated. Alternatively, if an alternative sham condition is used instead of a ‘No GVS’ condition, where some other GVS current is applied, then the effects of that waveform (e.g., stochastic resonance, down-weighting of vestibular information, altered tactile cues, etc.) become uncontrolled confounds between conditions. Finally, waveforms used for treatment have been ‘best guesses’ without models of how GVS impacts peripheral vestibular signals, perception, and motion sickness. Our approach of (1) generating a Beneficial GVS waveform computationally for empirical evaluation and (2) evaluating a complementary Detrimental GVS waveform of the same characteristics as the Beneficial waveform, opposite in polarity, enabled circumventing these issues.
With this experimental design, we sought to evaluate the following hypotheses. First, we hypothesized that motion sickness during physical motion will be lower in individuals given the ‘Beneficial’ GVS waveform, computationally predicted a priori to reduce motion sickness via the reduction of vestibular sensory conflict, than in individuals during the same physical motion paradigm given the administration of an equal and opposite, ‘Detrimental’ GVS waveform (computationally predicted a priori to increase motion sickness via the increase of vestibular sensory conflict). Second, we hypothesized that GVS could be utilized in the binaural bipolar configuration to reduce motion sickness symptom severity in the presence of passive, upright lateral translations compared to a control, in which GVS electrodes are worn without current applied.
Statistical analyses
Chosen metrics and statistical analyses were picked a priori from existing motion sickness analyses in the literature that used the verbal MISC reporting metric33,57,58. Motion sickness severity of an experimental condition was quantified using MISC rate: participants’ final MISC report during motion normalized by the time at that report. This metric was chosen as a scalar descriptor of motion sickness severity because it accounts for early termination of the experiment for participants that reached the stopping criterion before cessation of motion, and crucially, because it has been found to be the most discriminative measure of motion sickness for passive motions in the dark and is comparable to other paradigms of varying duration where it has been utilized previously33.
Utilizing the MISC rate metric, we evaluated GVS’s ability to alter motion sickness with a hierarchical, linear mixed-effect model, where each participant is given a random intercept (corresponding to the baseline, No GVS condition) to account for the dependence between observations of the same participant across conditions. This specific statistical analysis has been used previously in the literature to characterize known increases in MISC rate with increasing motion amplitude33. Here, we assess the slope coefficient within this model across a continuous independent variable: the GVS gain supplied to participants during each condition. The GVS gain for the Detrimental condition is −1 (polarity is flipped from Beneficial), the gain on the No GVS condition is 0 (no current is applied), and the gain on the Beneficial condition is 1. Because we predicted a priori that the Beneficial GVS condition would have lower motion sickness than the No GVS condition, which in turn would be lower than the Detrimental GVS condition, we hypothesized a negative slope, resulting from lower MISC rate with increasing gain on the GVS current. Here we utilize a two-tailed analysis, but we note that a one-tailed analysis was justified as a negative slope was predicted a priori.
Using paired t-tests, we then evaluated the individual hypotheses i.e., (1) the Beneficial GVS condition produces less motion sickness than the No GVS condition, and (2) the Beneficial GVS condition produces less motion sickness than the No GVS condition. We confirmed residuals were consistent with being normally distributed. To correct for family-wise error, we implemented a Bonferroni correction (factor of 2, reported as padj) on these tests. Because we had a priori directional hypotheses, quantified using a model of motion sickness with physical motion and GVS current as inputs, we conducted one-sided tests for each. Cohen’s d was used to compute effect size. For post-hoc power analyses, = 0.8.
Reporting summary
Further information on research design is available in the Nature Portfolio Reporting Summary linked to this article.
Supplementary information
Acknowledgements
This work was supported by a NASA Space Technology Graduate Research Opportunities Award.
Author contributions
A.R.A. and T.K.C. conceived the study. A.R.A., A.R.G., and T.K.C. prepared the manuscript. A.R.A. and T.K.C. designed the experimental protocol. A.R.A. and A.R.G. conducted the experiment. A.R.A. analyzed the data. All authors reviewed the results and approved the final version of the manuscript.
Peer review
Peer review information
Communications Engineering thanks Jean Laurens and John Golding for their contribution to the peer review of this work. Primary Handling Editors: [Or Perlman] and [Rosamund Daw]. Peer reviewer reports are available.
Data availability
Source and processed datasets generated during and/or analyzed during the current study are available on Open Science Framework (OSF) at the following link: https://osf.io/p4zjq/?view_only=09a54cc689af42d98c3a1c789be161a8.
Code availability
Modeling code is additionally available on Open Science Framework (OSF) at the following link: https://osf.io/p4zjq/?view_only=09a54cc689af42d98c3a1c789be161a8.
Competing interests
The authors declare no competing interests.
Footnotes
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
The online version contains supplementary material available at 10.1038/s44172-025-00417-2.
References
- 1.De Winkel, K. N., Irmak, T., Happee, R. & Shyrokau, B. Standards for passenger comfort in automated vehicles: acceleration and jerk. Appl. Ergon.106, 103881 (2023). [DOI] [PubMed] [Google Scholar]
- 2.Khalid, A. et al. Pharmacological and non-pharmacological countermeasures to Space Motion Sickness: a systematic review. Front. Neural Circuits17, 1150233 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Bos, J. E., Diels, C. & Souman, J. L. Beyond seasickness: a motivated call for a new motion sickness standard across motion environments. Vibration5, 755–769 (2022). [Google Scholar]
- 4.Davis, S., Nesbitt, K. & Nalivaiko, E. A systematic review of cybersickness. In Proceedings of the 2014 Conference on Interactive Entertainment. 1–9 10.1145/2677758.2677780 (ACM, 2014).
- 5.Kennedy, R. S., Lane, N. E., Berbaum, K. S. & Lilienthal, M. G. Simulator sickness questionnaire: an enhanced method for quantifying simulator sickness. Int. J. Aviat. Psychol.3, 203 (1993). [Google Scholar]
- 6.Stanney, K., Fidopiastis, C. & Foster, L. Virtual reality is sexist: but it does not have to be. Front. Robot AI7, 4 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Lackner, J. R. Motion sickness: more than nausea and vomiting. Exp. Brain Res.232, 2493–2510 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Golding, J. F. Motion sickness. In Handbook of Clinical Neurology. Vol. 137, 371–390. 10.1016/B978-0-444-63437-5.00027-3 (Elsevier, 2016). [DOI] [PubMed]
- 9.Oman, C. M. A Heuristic Mathematical Model for the Dynamics of Sensory Conflict and Motion Sickness. https://go.exlibris.link/rJjgfgfW (1982). [PubMed]
- 10.Oman, C. M. Motion sickness: a synthesis and evaluation of the sensory conflict theory. Can. J. Physiol. Pharmacol.68, 294–303 (1990). [DOI] [PubMed] [Google Scholar]
- 11.Reason, J. T. Motion sickness adaptation: a neural mismatch model. J. R. Soc. Med.71, 819–829 (1978). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Allred, A. R. & Clark, T. K. A computational model of motion sickness dynamics during passive self-motion in the dark. Exp. Brain Res. 10.1007/s00221-024-06804-z (2024). [DOI] [PubMed]
- 13.Murdin, L. et al. Motion sickness in migraine and vestibular disorders: figure 1. J. Neurol. Neurosurg. Psychiatry86, 585–587 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Paillard, A. C. et al. Motion sickness susceptibility in healthy subjects and vestibular patients: effects of gender, age and trait-anxiety. VES23, 203–209 (2013). [DOI] [PubMed] [Google Scholar]
- 15.Johnson, W. H., Sunahara, F. A. & Landolt, J. P. Importance of the vestibular system in visually induced nausea and self-vection. VES9, 83–87 (1999). [PubMed] [Google Scholar]
- 16.Cheung, B. S., Howard, I. P. & Money, K. E. Visually-induced sickness in normal and bilaterally labyrinthine-defective subjects. Aviat. Space Environ. Med.62, 527–531 (1991). [PubMed] [Google Scholar]
- 17.Oman, C. M. & Cullen, K. E. Brainstem processing of vestibular sensory exafference: implications for motion sickness etiology. Exp. Brain Res.232, 2483–2492 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Zobeiri, O. A. & Cullen, K. E. Cerebellar Purkinje cells in male macaques combine sensory and motor information to predict the sensory consequences of active self-motion. Nat. Commun.15, 4003 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Riccio, G. E. & Stoffregen, T. A. An ecological theory of motion sickness and postural instability. Ecol. Psychol.3, 195–240 (1991). [Google Scholar]
- 20.Valter, Y. et al. A review of parameter settings for galvanic vestibular stimulation in clinical applications. Front. Hum. Neurosci. 1910.3389/fnhum.2025.1518727 (2025). [DOI] [PMC free article] [PubMed]
- 21.Weech, S., Wall, T. & Barnett-Cowan, M. Reduction of cybersickness during and immediately following noisy galvanic vestibular stimulation. Exp. Brain Res.238, 427–437 (2020). [DOI] [PubMed] [Google Scholar]
- 22.Groth, C. et al. Omnidirectional galvanic vestibular stimulation in virtual reality. IEEE Trans. Vis. Comput. Graph.28, 2234–2244 (2022). [DOI] [PubMed] [Google Scholar]
- 23.Pradhan, G. N., Galvan-Garza, R. C., Perez, A. M., Stepanek, J. & Cevette, M. J. Visual vestibular conflict mitigation in virtual reality using galvanic vestibular stimulation. Aerosp. Med. Hum. Perform.93, 406–414 (2022). [DOI] [PubMed] [Google Scholar]
- 24.Allred, A. R., Austin, C. R., Klausing, L., Boggess, N. & Clark, T. K. Human perception of self-motion and orientation during galvanic vestibular stimulation and physical motion. PLoS Comput. Biol.20, e1012601 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Kwan, A., Forbes, P. A., Mitchell, D. E., Blouin, J. S. & Cullen, K. E. Neural substrates, dynamics and thresholds of galvanic vestibular stimulation in the behaving primate. Nat. Commun.10, 1904 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Forbes, P. A., Kwan, A., Mitchell, D. E., Blouin, J. S. & Cullen, K. E. The neural basis for biased behavioral responses evoked by galvanic vestibular stimulation in primates. J. Neurosci. 10.1523/JNEUROSCI.0987-22.2023 (2023). [DOI] [PMC free article] [PubMed]
- 27.Clark, T. K., Newman, M. C., Karmali, F., Oman, C. M. & Merfeld, D. M. Mathematical models for dynamic, multisensory spatial orientation perception. Prog. Brain Res.248, 65–90 (2019). [DOI] [PubMed] [Google Scholar]
- 28.Merfeld, D. M., Young, L. R., Oman, C. M. & Shelhamert, M. J. A multidimensional model of the effect of gravity on the spatial orientation of the monkey. VES3, 141–161 (1993). [PubMed] [Google Scholar]
- 29.Newman M. C. A Multisensory Observer Model for Human Spatial Orientation Perception (Massachusetts Institute of Technology, 2009).
- 30.Laurens J. The otolith vermis: a systems neuroscience theory of the Nodulus and Uvula. Front. Syst. Neurosci. 16, Accessed 13 June 2023. https://www.frontiersin.org/articles/10.3389/fnsys.2022.886284 (2022). [DOI] [PMC free article] [PubMed]
- 31.Angelaki, D. E., Shaikh, A. G., Green, A. M. & Dickman, J. D. Neurons compute internal models of the physical laws of motion. Nature430, 560–564 (2004). [DOI] [PubMed] [Google Scholar]
- 32.Laurens, J., Meng, H. & Angelaki, D. E. Computation of linear acceleration through an internal model in the macaque cerebellum. Nat. Neurosci.16, 1701–1708 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Irmak, T., Kotian, V., Happee, R., de Winkel, K. N. & Pool, D. M. Amplitude and temporal dynamics of motion sickness. Front. Syst. Neurosci.16, 866503 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Fitzpatrick, R. C. & Day, B. L. Probing the human vestibular system with galvanic stimulation. J. Appl. Physiol.96, 2301–2316 (2004). [DOI] [PubMed] [Google Scholar]
- 35.Merfeld, D. M., Zupan, L. & Peterka, R. J. Humans use internal models to estimate gravity and linear acceleration. Nature398, 615–618 (1999). [DOI] [PubMed] [Google Scholar]
- 36.Angelaki, D. E., McHenry, M. Q., Dickman, J. D., Newlands, S. D. & Hess, B. J. M. Computation of inertial motion: neural strategies to resolve ambiguous otolith information. J. Neurosci.19, 316–327 (1999). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Roy, J. E. & Cullen, K. E. Selective processing of vestibular reafference during self-generated head motion. J. Neurosci.21, 2131–2142 (2001). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Jamali, M., Sadeghi, S. G. & Cullen, K. E. Response of vestibular nerve afferents innervating utricle and saccule during passive and active translations. J. Neurophysiol.101, 141–149 (2009). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Brooks, J. X. & Cullen, K. E. Multimodal integration in rostral fastigial nucleus provides an estimate of body movement. J. Neurosci.29, 10499–10511 (2009). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Laurens, J. & Angelaki, D. E. A unified internal model theory to resolve the paradox of active versus passive self-motion sensation. eLife6, e28074 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Young L. R. Space motion sickness and vestibular adaptation to weightlessness. Accessed 29 April 2024. https://ntrs.nasa.gov/citations/19840047546 (1983).
- 42.Young, L. R., Oman, C. M., Watt, D. G. D., Money, K. E. & Lichtenberg, B. K. Spatial orientation in weightlessness and readaptation to earth’s gravity. Science225, 205–208 (1984). [DOI] [PubMed] [Google Scholar]
- 43.Brooks, J. X. & Cullen, K. E. The primate cerebellum selectively encodes unexpected self-motion. Curr. Biol.23, 947–955 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Graybiel, A., Miller, E. F. & Homick, J. L. Individual differences in susceptibility to motion sickness among six Skylab astronauts. Acta Astronautica.2, 155–174 (1975). [DOI] [PubMed] [Google Scholar]
- 45.Kravets, V. G. A Computational Tool to Model Astronaut Neurovestibular Adaptation to Altered Gravity (University of Colorado Boulder, 2024). [DOI] [PMC free article] [PubMed]
- 46.Allred, A. R., Kravets, V. G., Ahmed, N. & Clark, T. K. Modeling orientation perception adaptation to altered gravity environments with memory of past sensorimotor states. Front. Neural Circuits. 1710.3389/fncir.2023.1190582 (2023). [DOI] [PMC free article] [PubMed]
- 47.Kravets, V. G., Dixon, J. B., Ahmed, N. R. & Clark, T. K. COMPASS: computations for orientation and motion perception in altered sensorimotor states. Front. Neural Circuits15. Accessed 18 March 2022. https://www.frontiersin.org/article/10.3389/fncir.2021.757817 (2021). [DOI] [PMC free article] [PubMed]
- 48.Kravets, V., Ahmed, N. & Clark, T. A Rao-Blackwellized particle filter for modeling neurovestibular adaptation to altered gravity. In 51st International Conference on Environmental Systems. Vol ICES-2022-27. Accessed 5 July 5 2023. https://ttu-ir.tdl.org/handle/2346/89576 (51st International Conference on Environmental Systems, 2022).
- 49.Bos, J. E. Nuancing the relationship between motion sickness and postural stability. Displays32, 189–193 (2011). [Google Scholar]
- 50.O’Hanlon, J. & McCauley, M. Motion sickness incidence as a function of vertical sinusoidal motion.pdf. Aerosp. Med. Hum. Perform.45, 366–369 (1974). [PubMed] [Google Scholar]
- 51.Aoyama, K., Iizuka, H., Ando, H. & Maeda, T. Four-pole galvanic vestibular stimulation causes body sway about three axes. Sci. Rep.5, 10168 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Bos, J. E., MacKinnon, S. N. & Patterson, A. Motion sickness symptoms in a ship motion simulator: effects of inside. Outs. No View.76, 8 (2005). [PubMed] [Google Scholar]
- 53.de Winkel, K. N., Irmak, T., Kotian, V., Pool, D. M. & Happee, R. Relating individual motion sickness levels to subjective discomfort ratings. Exp. Brain Res.240, 1231–1240 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54.Golding J. F. Motion sickness susceptibility. Auton. Neurosci. 129, 67–76 (2006). [DOI] [PubMed]
- 55.Allred, A. R., Lippert, A. F. & Wood, S. J. Galvanic vestibular stimulation advancements for spatial disorientation training. Aerosp. Med Hum. Perform.95, 390–398 (2024). [DOI] [PubMed] [Google Scholar]
- 56.Allred, A. R. Galvanic Vestibular Stimulation as a Countermeasure to Motion Sickness in Astronauts (University of Colorado Boulder, 2024).
- 57.Irmak, T., de Winkel, K. N., Pool, D. M., Bülthoff, H. H. & Happee, R. Individual motion perception parameters and motion sickness frequency sensitivity in fore-aft motion. Exp. Brain Res.239, 1727–1745 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58.Irmak, T., Pool, D. M. & Happee, R. Objective and subjective responses to motion sickness: the group and the individual. Exp. Brain Res.239, 515–531 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
Source and processed datasets generated during and/or analyzed during the current study are available on Open Science Framework (OSF) at the following link: https://osf.io/p4zjq/?view_only=09a54cc689af42d98c3a1c789be161a8.
Modeling code is additionally available on Open Science Framework (OSF) at the following link: https://osf.io/p4zjq/?view_only=09a54cc689af42d98c3a1c789be161a8.