Table 2.
Linear mixed effect model for serum IgG level during RTX/OCR in the two cohorts.
Predictors |
Serum IgG level |
||
---|---|---|---|
Estimates | CI | p | |
(Intercept) | 11.21 | 10.66–11.76 | <0.001 |
Centre [EID cohort] | −1.32 | −1.81–−0.84 | <0.001 |
Delay since RTX/OCR initiation | −0.33 | −0.40–−0.27 | <0.001 |
Age | −0.02 | −0.02–−0.01 | <0.001 |
SEX [M] | −0.36 | −0.58–−0.14 | 0.002 |
Centre [EID cohort] × delay since RTX/OCR initiation | 0.15 | 0.06–0.23 | 0.001 |