Skip to main content
. Author manuscript; available in PMC: 2025 May 6.
Published in final edited form as: Int J Heat Mass Transf. 2018 Dec;127:10.1016/j.ijheatmasstransfer.2018.07.145. doi: 10.1016/j.ijheatmasstransfer.2018.07.145

Table 3.

Model input.

Geometry and property Value

Diameter of the channel Dh=180μm,110μm
Width of the channel W=Dh/2π
Thickness of the wall thw=100µm
Thermal conductivity of wall kw=16Wm1K1@300K
kw=10Wm1K1@150K
kw=6Wm1K1@70K
Thermal conductivity of fluid kf=0.025Wm1K1@300K
kf=0.014Wm1K1@150K
kf=0.145Wm1K1@70K
Viscosity of fluid μ¯=17×106Pa-s
μ¯=10×106Pa-s
μ¯=164.95×106Pa-s
Heat capacity of fluid cp=1047kJkg1K1
cp=1089kJkg1K1
cp=2024kJkg1K1
Heat input to wall 0.1 W
Nusselt number Nu=4.36