Abstract
Activated carbon block (ACB) filters are widely used in point-of-use (POU) drinking technology to remove tastes, odors, and organic compounds from drinking water, and when modified can even remove inorganic pollutants (e.g., arsenate, lead, copper). To introduce ACB technologies to the POU market, thorough assessment and testing are required to meet the National Sanitary Foundation 53 certification. Testing to gain this certification can be costly and time-consuming and is usually only done on the final product before commercial distribution. We developed and explored how a cylindrical “plug” cored from an ACB can be used in a small-sized apparatus with low water volumes, to mimic full-sized ACB performance. These mini-cores allow the same outside-in radial flow conditions as the full-sized ACB. After addressing potential hydraulic channeling problems, tests with chloroform or arsenate confirmed the ability of the small-scale ACB “plugs” to mimic full-scale performance. The benefit of the small-scale ACB “plug” lab-scale approach lays the foundation for testing methodologies that can evaluate a range of pollutants, water chemistries, or material modifications using a small fraction of water compared to full-scale carbon blocks. Overall, the development of a small-scale ACB testing apparatus is a key advancement towards sustainable water purification, impacting environmental health, resource conservation, and global access to safe water.
Keywords: Carbon block filter, Small-scale carbon block apparatus, pollution, Chloroform, Arsenic, point-of-use, drinking water, tap water
1. Introduction
Point-of-use (POU) drinking water treatment systems have seen extensive adoption as essential devices for water purification in households around the globe, marking a significant aspect of home water treatment strategies in various countries (Chen et al., 2021). The array of POU devices found in the marketplace incorporates a multifaceted blend of technologies, and include sediment filters (Pratson et al., 2010), activated carbon block (ACB) filters (Alfredo et al., 2020), ion exchange materials (Chen et al., 2020), arsenic adsorbent packed beds (e.g., granular iron hydroxide), catalytic reactors (e.g., manganese greensand), membranes (e.g., microfiltration (MF), nanofiltration (NF), reverse osmosis (RO), and forward osmosis (FO)) (Butler et al., 2013; Mecha and Pillay, 2014; Rho et al., 2022a; Xia et al., 2007)), ultraviolet radiation (Lui et al., 2016; Zhao et al., 2021), among others (Silverstein, 2006). The global POU water treatment system market is estimated to reach a value of approximately $53.6B by 2030. In terms of technology, although RO dominates (34.6% of the market) the majority of this market share, the filtration (i.e., pre-sediment and ACB filter) segment of the POU is still expected to grow at the fastest compound annual growth rate (CAGR) over the forecast period (Wood, 2024). Market growth, especially in the Middle East, Asia and Africa, is due to increasing water pollution along with growing awareness, aesthetic concerns and affordability.
Among POU systems, the activated carbon block filter, a compressed blend of activated carbon and a binder material, is present alone or as a prefilter in most POU systems because it has a broad-spectrum pollutant removal performance, easy to replace nature, no chemical or electrical supply requirements, and low-cost (Alfredo et al., 2020; Wu et al., 2017). ACB filters go beyond aesthetics to improve drinking water quality by separating particulate matter, microbial cysts, lead, volatile organic compounds (VOCs), and a broad array of chemical pollutants (Campos and Büchler, 2005; CBTech, 2016). The ACB market is rapidly changing with innovations in treatment technologies and the addition of sensors to monitor performance and maintenance.
The ACB manufacturing involves selection of activated carbons (i.e., bituminous or lignite-based) and a binder (e.g., polymer), along with other proprietary functional additives such as metals or catalysts. These materials are mixed before molding and heating in casting the ACB with a press or extrusion process. The resulting ACB is a semiporous ceramic-like cylinder wherein water flows from the outside into a center space, and then out the device. Treatment technologies include the addition of multifunctional media/materials and their addition within the ACB for wider functionalities to remove wider ranges of targeted contaminants from water (Farsad et al., 2023a; Farsad et al., 2023b).
POU treatment units are often validated by third-party entities, such as the National Sanitary Foundation (NSF) International which work with stakeholders (e.g., USEPA) to develop American National Standards Institute (ANSI) standards (US EPA, 2006). The NSF/ANSI Standard outlines foundational criteria for the certification process applicable to POU drinking water treatment systems. Testing protocols delineate a comprehensive framework for the composition and attributes of the feed sample water, encompassing concentrations of prevalent minerals, alongside detailed methodologies encompassing test execution, sampling procedures, and additional analytical techniques. The efficacy of the ACB filter can be assessed within the manufacturing laboratory adhering to the benchmarks set forth in Standards 42 and 53 as advocated by NSF/ANSI. Here, Standard 42 pertains to the filtration aimed at mitigating aesthetic pollutants (for instance, chlorine, taste, and odor), while Standard 53 is dedicated to the diminution of contaminants linked to health risks (such as lead and arsenic) (CBTech, 2016; Lau et al., 2005; NSFInternationalStandard, 2017).
Certification of ACB filters requires a substantial volume of test water alongside ample space to accommodate testing apparatus, including tanks, pumps, and piping systems. Evaluation of the effectiveness of full-scale ACB in test water can be expensive due to the multiple chemicals needed to create model waters containing spiked contaminants in deionized water. Additionally, safe disposal of treated water and spent ACB adsorbent is necessary after conducting these tests. Several studies have been conducted by other researchers and have reported sustainability and health issues associated with these concerns (Carrière et al., 2011; Lau et al., 2005; Van Dyke et al., 1986). Overall, external validation, and routine in-house quality control testing, is a costly process. There is a need for lower cost screening for new ACB formulations or routine quality control testing that use less water (often spiked with costly chemical pollutants) to evaluate ACB, especially during initial product development and comparison of water quality from different geographic regions.
This research endeavored to create and validate a compact-scale apparatus for performance evaluations of ACB filters. For this purpose, two small-scale ACB holders were designed and evaluated for short-circuit minimization and reusability. Second, the breakthrough curves for both inorganic and organic pollutants were assessed and compared with the reported full-scale ACB performance within acceptable ranges. Third, the diminutive ACB device was juxtaposed against its full-scale counterpart by conducting simultaneous tests on both the small- and full-scale ACB units under identical conditions. All the above steps and results have been discussed for verifying the acceptance of a small-scale ACB when mimicking a full-scale ACB device performance.
2. Methods and Materials
2.1. Materials
Chemicals were purchased and used to prepare model solutions that were passed through carbon block systems. Chloroform was purchased (Merck, Darmstadt, Germany). Methylene blue (MB) was purchased (Fluka, Buchs, Switzerland). Sodium arsenate heptahydrate (Na2HAsO4·7H2O) was purchased (JT Baker, Phillipsburg, NJ). A commercially available full-scale ACB filter extruded into a hollow cylindrical shape (outer diameter of 150 mm, inner diameter of 50 mm, and height of 110 mm) was provided by our industrial partner (Amway, Ada, Michigan). Deionized (DI) water obtained from a water purification system (Millipore, France) with a resistivity of >18 MΩ cm. Local tap water (Tempe, AZ, USA) was used in experiments; water was collected from inside our building where we previously reported its water chemistry (Richard et al., 2020; Saetta et al., 2021).
2.2. Small-scale ACB preparation & device holder
To simulate full-scale ACB performance, a small-scale ACB with a diameter of 32 mm and thickness of 25 mm was prepared by cutting a full-scale hollow cylinder-shaped ACB with a bandsaw cutting and drill press machines to reach the targeted diameter (Figures 1a and 1b). The cored-out ACB cylinder surface and edges were smoothed using sandpaper to fit the ACB holder.
Figure 1.

(a) A schematic diagram of the preparation procedure of small-scale ACB and (b) a photograph image of the small-scale ACB (Ø = 32 mm, h = 25 mm). (c) Photographs of brass and PVC pipe small-scale ACB holders.
Two types of small-scale ACB holders were fabricated from either 1) polyvinyl chloride (PVC) pipes, or 2) machined brass (Figure 1c). Table S1 presents a comparison between the two types of small-scale ACB holders. The holder of PVC pipe was manufactured by securing the sockets within a PVC pipe using epoxy adhesive, while the brass ACB holder was fabricated by a machining firm in alignment with the specified design schematics. (Figure S1). In the case of the PVC pipe holder, a small-scale ACB filter was positioned within a 35 mm PVC pipe, utilizing adhesive to ensure the filter was firmly secured and snugly accommodated by the holder. For the brass holder, a small-scale ACB was inserted into the lower part of the holder, rubber and an O-ring were placed inside the upper part of the holder to prevent channeling problems, and the upper and lower parts of the brass holder were assembled.
Figures 2 shows a flow diagram for water through the small-scale ACB test apparatus and its setup (Figure S2 includes additional details). The setup included a container for test water, a pump, a digital timing device, a flow moderator, a pressure measuring instrument, and a holder for the small-scale ACB filter. A plastic barrel with a capacity of 200 L served as the reservoir for the test water. The feed water was directed into the holder of the small-scale ACB filter in an upward flow configuration, employing a fluid-metering pump to maintain a flow rate of 60 mL/min (FMI, QG50). A digital timer (Intermatic, Spring Grove, IL, USA) with dual plugs was installed along with a pump to simulate an intermittent on/off system. A flow dampener was utilized to mitigate the pulsating effect of the water emanating from the pump, while a pressure gauge was deployed to track the backpressure generated by the small-scale ACB. After setting and sealing, performance tests were performed via visual indication of MB adsorption by allowing a small quantity of MB solution to pass through the full-scale ACB filter as an assurance test (Van Dyke et al., 1986).
Figure 2.

Performance test apparatus for full-scale and small-scale ACBs.
Table 1 lists the design features and operational conditions of the small-scale ACB. The volume of a small-scale ACB is approximately 57 times smaller than that of a full-scale ACB, which is a significant benefit of small-scale ACB testing. The test using the small-scale ACB drastically reduced (×57 times lower) the feed flow rate and volume of test water while maintaining the same operating conditions as those in the full-scale operation, such as the empty-bed contact time (EBCT) and operation time.
Table 1.
Design attributes and functional parameters of ACBs.
| Parameters | Full-scale ACB | Small-scale ACB |
|---|---|---|
| Height (mm) | 150 | 25 |
| Outer diameter (mm) | 110 | 32 |
| Inner diameter (mm) | 50 | 32 |
| Volume of ACB (cm3) | 1,130 | 20 |
| Flow rate (ml/min) | 3,400 | 60 |
| EBCT (s) | 20 | 20 |
| Operation time (h) | 25 | 25 |
| Volume treated (L) | 5,100 | 90 |
| Surface loading rate (ml/cm2.min) | 6.6–14.4 | 7.5 |
2.3. Performance evaluation of small-scale and full-scale ACBs
Full-scale and small-scale ACBs were simultaneously evaluated using chloroform and arsenate (As(V)) as model contaminants under the same experimental conditions to investigate whether the small-scale ACB could adequately simulate the full-scale ACB performance tests. Figure 2 depicts the schematic representation of the testing apparatus for evaluating the performance of both full-scale and small-scale ACBs.
The first set of arsenic removal tests were performed on commercially available ACB modified with iron (Altwell, South Korea). The ACB influent water contained 100–120 μg/L was fed to the full-scale ACB along with the small-scale ACBs by adjusting the flow rate with flow meters. The pH level of the test water was modified to 6.5 with nitric acid (HNO3), aligning it with the pH conditions recommended by the manufacturer. A 10 mg/L As(V) solution in a 110-L container was prepared by continuously spiking the As(V) stock solution into dechlorinated tap water and was continuously transported to the inline mixer using a dosing pump (LE02SA, Pulsafeeder). During operation, both the operational parameters, such as flow rate and pressure, and the water quality indicators, including pH, electrical conductivity (EC), and temperature, were diligently monitored. The cumulative volume processed by the system amounted to roughly 14,000 L for the full-scale ACB and 240 L for the small-scale ACB, corresponding to 25,000 bed volumes (BVs).
Chloroform, a prevalent component of chlorinated tap water as part of the trihalomethane (THM) group, served as a benchmarking chemical in assessing the efficiency of full-scale ACB; chloroform is also used as part of NSF/ANSI standard certification. To evaluate the efficacy of small-scale ACB, test water containing 300 μg/L of chloroform was concocted by infusing 6 mL of a 10,000 mg/L chloroform solution into 200 L of dechlorinated tap water, which was then circulated through the ACB holder at a rate of 60 mL/min. Comparative analyses of chloroform elimination were executed for full-scale tests under identical experimental conditions, facilitating a direct comparison with the outcomes from the small-scale ACB performance assessment.
To demonstrate how the small-scale ACB can be integrated into development of novel ACB, we compared performance of a full-scale customized and modified ACB for arsenate removal. Briefly, a commercial (ICEPURE™) ACB was impregnated with an amorphous titanium (hydr)oxide-impregnated based upon prior published methodologies (Farsad et al., 2023a; Farsad et al., 2023b; Traegner and Suidan, 1989; Wang et al., 2023). Tap water with a was spiked with 100 μg/L arsenate and pumped through the modified ACB with an EBCT of 17 s (0.28 min) that is within the common range of the POU systems (<1 min).
2.4. Analytical methods
The ultraviolet (UV) absorbance of MB was quantified at a wavelength of 664 nm employing a UV-Visible spectrophotometer (DR 5000, HACH, Loveland, CO, USA) (Rizzo et al., 2007). As(V) analysis was carried out using an inductively coupled plasma mass spectrometer (ICP–MS; Thermo Fisher Scientific, XSeries II, USA) (Yan et al., 1998). Before ICP–MS analysis, the collected samples were refrigerated following acidification with concentrated HNO3. Chloroform was sampled (headspace-free 40 mL amber glass vials) prior to analysis using a gas chromatography-mass spectrometry (GC–MS) instrument (Varian CP-3800 GC and Varian 320 MS models, Varian Inc., USA) from SCION Instruments and Purge&Trap from Tekmar (Eichelberger et al., 1995). Scanning electron microscopy (SEM; Philips XL-30, Eindhoven, The Netherlands) was used to investigate the surface morphology of ACB (Hailemariam et al., 2022). Prior to analysis, the samples were coated with gold/palladium for 60 s using an ion sputter device (E-1030, Hitachi, Tokyo, Japan) to mitigate electron-charging effects on the surface. The structure of the ACB was also examined by X-ray diffraction (XRD; Bruker D8 multipurpose Diffractometer, Germany) in θ/2θ geometry with Cu Kα radiation operating at 40 kV and 40 mA (Rho et al., 2022b).
3. Results and Discussion
3.1. ACB characterization
Figure 3 shows characterization data for the iron-impregnated ACB. The SEM images confirmed the microstructure of ACB composed of porous activated carbon grains with irregular shapes and sizes (ranging from 50 to 150 μm). A small amount of deposited materials attached to the activated carbon surface included residual char from the polymeric binder plus iron (hydr)oxides introduced during the manufacturing process. XRD analysis suggests the presence of both maghemite/magnetite and goethite on ACB. XRD result showed the presence of amorphous carbon, whose diffraction pattern in ACB is composed of three broad peaks, which can be indexed to the (002), (100), and (110) graphite-type reflections.
Figure 3.

Surface characteristics of iron-impregnated ACB (Altwell) including (a) SEM images at various magnifications, (b) XRD patterns.
3.2. ACB holder hydraulic evaluation
Before the performance tests with arsenate or chloroform, sealing tests of small-scale ACB in two different holders (PVC pipe and brass holder) were conducted using MB to visually observe whether the holder was well sealed and to confirm no hydraulic short-circuiting or channeling issues existed. Table S2 summarizes the sealing test results using the MB solution. Initially, rapid MB breakthrough occurred and indicated that channeling or short-circuiting occurred in the PVC holder owing to its inner structural features (such as connection with epoxy gluing). Furthermore, because of the glues used to hold the ACB in the PVC holder, the system was not considered reusable nor easy to extract the used ACB for post-experimental autopsy.
In contrast with the initial testing using the PVC holder of ACB, the brass holder equipped with rubber O-rings on each end offered numerous benefits. First, there was no hydraulic channeling or short-circuiting of MB observed (Table 2). This was because the rubber O-rings replaced glue to seal in the ACB. Second, the brass holder could be assembled with ACB in < 30 minutes whereas the > 1 day was needed for the PVC and glues to cure. Third, the used ACB could be removed from the brass holder for post-experimental analysis without any contamination from glues. Finally, the brass holder was reusable, and thus reduces generation of plastic and other waste materials. Therefore, the brass ACB holder device was used in all subsequent experiments.
Table 2.
Sealing test result for small scale ACB holders.
| ACB holder type | Test period (min) | Channeling problem | MB (mg/L) | Removal (%) | |
|---|---|---|---|---|---|
| Influent | Effluent | ||||
| PVC pipe | 15 | Yes | 1.10 | 0.85 | 26.9 |
| PVC pipe | 15 | Yes | 0.90 | 0.02 | 98 |
| PVC pipe | 15 | No | 2.00 | 0 | 100 |
| Brass | 15 | No | 2.00 | 0 | 100 |
| Brass | 10 | No | 2.00 | 0 | 100 |
| Brass | 5 | No | 21.42 | 0 | 100 |
3.3. Methylene blue removal in continuous- versus intermittent-flow POU testing
Figure 4a shows the triplicate breakthrough curves for MB with continuous-flow small-scale ACBs normalized to the influent MB concentrations (C/C0). The first and second ACB (CB-1 and 2) demonstrated an earlier breakthrough (defined as a normalized effluent concentration C/C0 = 0.1) at only 1,230 BVs. Earlier breakthrough in CB-1 and 2 was attributed to the short-circuiting flow between the packed ACB and the ACB holder. To address this issue, polytetrafluoroethylene (PTFE) tape was utilized to secure the ACBs within the holder, effectively resolving the problem of short-circuiting. Consequently, the third ACB (CB-3) achieved >99% MB removal for over 5,000 BVs. Upon conducting additional experiments to verify the CB-3 results, similar results of complete MB removal over 4,000 BVs were observed (Figure 4b). Subsequently, all tests were performed using the improved method to prevent short-circuiting.
Figure 4.

(a) Continuous-flow experiments showing MB breakthrough profiles for small-scale ACBs under continuous flow and 10-minute cyclic operation modes (C0 = 5.0 mg/L, ν = 60 mL/min). (b) Comparisons of MB breakthrough curves for small-scale ACBs operated in continuous-flow versus intermittent-flow modes (C0 = 10 mg/L, ν = 60 mL/min).
Figure 4b compares the MB breakthrough curve for small-scale ACBs in continuous-flow versus intermittent-flow (i.e.,10 min of on/off operation cycles). Cycling more closely represented real-world usage patterns of POU water treatment devices. Unlike faucets left running continuously, POU-water treatment devices are typically used intermittently. During the no-flow (i.e., off) cycle, pollutants can potential diffuse into the intraparticle pores of the activated carbon. Data in Figure 4b were normalized to absolute bed volumes of water treated on the x-axis. Comparable performance of MB removal was achieved in continuous- and intermittent-flow operation modes. Because the continuous-flow tests require only have the operational run-time, subsequent experiments primarily relied upon continuous-flow mode testing. Thus, these results validated that the contaminant removal efficiency in ACB is not significantly impacted by the operational mode (continuous-flow versus intermittent-flow).
3.4. Comparisons of mini- versus commercial-sized ACB performance
Chloroform is a disinfection by-product and primarily removed by adsorption within ACBs (Tsai et al., 2008; Xiang et al., 2020). Figure 5 shows the chloroform breakthrough of both small-scale and full-scale ACBs from tap water spiked with 300 μg/L of chloroform. The dashed line indicates the breakthrough point, where the normalized effluent concentration (C/C0) reached a value of 0.1. The breakthrough of the small-scale ACB began at 7,000 BV, which was comparable with results using full-scale ACB. Both ACB test devices continued to perform similar throughout the experiment, reaching ~50% breakthrough after 11,000 BVs. These results validated that small-scale ACB can accurately simulate the performance of full-scale ACB.
Figure 5.

Chloroform breakthrough curves for experiments using small-scale and full-scale ACB devices (C0 = 300 μg/L, ν = 60 mL/min, pHi = 7.5). The dashed line indicates the breakthrough point, where the normalized effluent concentration (C/C0) reaches 0.1.
Prior work confirmed that non-modified carbon block did not remove arsenate, but ACB impregnated with metal (hydr)oxides can remove anionic arsenate or even non-ionic arsenite (Farsad et al., 2023b). Arsenate is present in most municipal tap waters because they have been disinfected with oxidants (e.g., chlorine). Either arsenite (As(III)) or arsenate can occur in private well water, but for these tests experiments focused on comparing hydraulic and adsorption behavior rather than redox behavior – and therefore experiments were performed using only As(V).
Commercially-available full-scale carbon blocks impregnated with iron were used in parallel experiments to assess arsenate removal in the full-scale iron impregnated carbon block and a core of this material placed in the mini-ACB device. The vendor for the iron impregnated carbon block claimed removal of arsenate for up to 10,000 L (AltwellTech, 2017). Figure 6a shows excellent reproducibility of arsenate breakthrough using two replicate small-scale ACBs. No short-circuiting was observed, and arsenate breakthrough exhibited a classical “S-shaped” breakthrough curve characteristic of other granular iron packed bed adsorbents (Badruzzaman et al., 2004). Approximately 50% arsenate breakthrough occurred after treating 10,000 BV.
Figure 6.

(a) Duplicate arsenate breakthrough curves for small-scale ACBs, (C0 = 116 μg/L, EBCT = 20 s, conductivity = 1.4 mS/cm, pHi = 6.5, T = 23 ± 1 °C), (b) Comparison of breakthrough curves for small-scale and full-scale ACBs (C0 = 102 μg/L, EBCT = 20 s, conductivity = 1.4 mS/cm, pHi = 8.0, T = 23 ± 1 °C), (c) pH for both full-scale and small-scale ACBs using tap water spiked with arsenate, (d) electrical conductivity (EC) for both full-scale and small-scale ACBs using tap water spiked with arsenate.
After showing excellent reproducibility of the mini-ACB device using the iron-impregnated ACB, a second batch of water, with a slightly lower influent arsenate concentration, was used to compare performance of the mini- to as-received full-scale iron-ACB. Figure 6b shows the comparative breakthrough curves are also in very good agreement, again validating the use of the mini-ACB device. The full-scale ACB operated at a flow-rate of 3,400 mL/min, and 10,000 L of water was processed after passing 18,000 BV of water. The mini-ACB system only required 170 L of water, representing a considerable savings of not only water but also the carcinogen arsenic itself which was spiked in just for these tests.
While the commercial vendor marketing material reported complete arsenate removal for 10,000 L, clearly our testing did not confirm this reported finding (Figure 6b). The most likely reason for this was differences in water quality used in the tests. The pH and EC of the effluents from the full-scale and small-scale ACB systems demonstrated similar values during the entire test (Figures 6c and 6d). We have previously shown that pH, silica and presence of competing solutes (e.g., vanadate, tungstate, etc.) impact performance of arsenate removal using iron-based adsorbents (Badruzzaman et al., 2004). This highlights the need for testing capabilities that use local water sources, and our mini-ACB device enables such lab-scale testing of one or multiple adsorbents using a small volume of the water, compared against >57 times larger volume required to test commercial-scale ACB modules.
3.5. Comparisons of arsenate removal performance for mini- versus commercial-sized ACB impregnated with amorphous titanium (hydr)oxide
Breakthrough curves for arsenate removal by the modified ACB shown in Figure 7 demonstrates excellent agreement between the mini- and commercial-sized ACB. Using the area above the breakthrough curve and hydraulic flowrate, after treating 10,000 BV of water containing 100 μg/L As(V) the mini-ACB yielded an adsorption capacity of 4.1 mg As/g Ti, which is comparable to the adsorption capacity of 4.6 mg As/g Ti obtained for the full-scale ACB. Prior work showed the ability of these types of modified carbon block to remove both oxidation forms of arsenic (i.e., arsenite and arsenate) (Farsad et al., 2023a; Farsad et al., 2023b).
Figure 7.

Comparison of breakthrough curves for small-scale and full-scale amorphous titanium (hydr)oxide-impregnated ACBs (C0 = 100 μg/L, EBCT = 20 s, conductivity = 1.4 mS/cm, pHi = 7.9, T = 23 ± 1 °C).
Comparable breakthrough curves obtained for both small-scale and full-scale ACBs allow for parameterization and predictive modeling of the ACB. In prior work, arsenate removal by mini amorphous titanium (hydr)oxide-impregnated ACB was parameterized and simulated using the pore-surface diffusion model (PSDM) (Farsad et al., 2023b). Impregnated ACB had high pore and surface diffusivities of 3.2×10−6 and 3.1×10−12 cm2/s, respectively, enabling rapid removal of arsenic from water and into the activated carbon block pores containing amorphous titanium (hydr)oxide surface films. The combined Biot number (Bic) was 32, which signified that both film mass transfer and intraparticle diffusion were important (Traegner and Suidan, 1989) in arsenic removal by the modified ACB. The ability to parameter a PSDM using mini-ACB systems significant reduced operational limitations (e.g., water volume) but also simplified flow assumptions because the mini-ACB has single-direction longitudinal flow, compared against conical flowlines that exist in outside-inward flow of tubular full-scale ACB. The experimental and modeling work was further extended and predicted well cyclical (on-off) periods of water flow through the ACB device. This represented more realistic applications of how POU systems operate. Overall, the mini-ACB and associated modeling aided in rapid prototyping and testing of a novel strategy to impregnate ACB for arsenic removal, without detrimentally impact ACB removal capacity for organic pollutants that co-occurred in influent water.
4. Conclusions
A small-scale ACB device was engineered to emulate the operational efficacy of full-scale ACBs. The brass ACB holder equipped with O-rings was employed as a small-scale ACB apparatus because it saved preparation and setup time, was reusable, and eliminated hydraulic channeling concerns. Without channeling, 100% of the MB was removed using an effectively sealed ACB holder. Furthermore, tests on the removal of chloroform showed that the small-scale ACB accurately mimicked the performance of full-scale ACBs, reaching equivalent levels of chloroform breakthrough at ~7,000 BVs. During arsenic removal tests both the full- and small-scale ACBs exhibited comparable patterns of As(V) breakthrough, suggesting that the small-scale ACB apparatus developed as part of this research can effectively mimic the performance of a full-scale ACBs. Hence, the small-scale ACB device serves as a practical tool for assessing or swiftly evaluating full-scale ACBs, with the added benefits of diminishing water use and shortening the time necessary to comply with NSF test procedures.
By accurately simulating full-scale ACB performance, the mini-ACB approach used fewer resources (i.e., 57 times water savings; less arsenic or other spiked chemicals) and less costly small-scale apparatus, this innovative approach directly contributes to reducing the environmental footprint associated with the testing and development of water treatment technologies. Because water quality differs around the globe, water from different locations can easily be shipped to a central laboratory where mini-ACB tests can using non-modified or metal (hydr)oxide (e.g., iron, titanium) modified ACB to better understand water quality impacts and aid in selecting optimized ACBs for different geographic locations. The mini-ACB approach has already proven successful in supporting development of new strategies to modify ACB, using titanium sol-gel impregnation techniques that appear to perform better than iron-impregnated systems (Farsad et al., 2023b). Overall, the development of a small-scale ACB testing apparatus represents a significant step in the pursuit of sustainable water treatment solutions, with broad implications for environmental health, resource conservation, and ensuring access to safe drinking water, which is a global challenge.
Supplementary Material
Acknowledgments
The authors thank K-water (Korea Water Resources Corporation) which provided a research fellowship for Heuidae Lee and partial funding provided by Nanotechnology Enabled Water Treatment Center (NEWT) through the National Science Foundation (NSF) award (EEC-1449500) and the AWII Global Center for Water Technology at Arizona State University. Additional support was provided by the National Research Foundation of Korea (NRF) and Commercialization Promotion Agency for R&D Outcomes (COMPA) grant funded by the Korea government (MSIT) (RS2023-00233235).
References
- Alfredo K, Lin J, Islam A and Wang ZW 2020. Impact of activated carbon block point-of-use filters on chloraminated water quality. AWWA Water Science 2(3), e1180. [Google Scholar]
- AltwellTech 2017. Standard Carbon Block. [Google Scholar]
- Badruzzaman M, Westerhoff P and Knappe DR 2004. Intraparticle diffusion and adsorption of arsenate onto granular ferric hydroxide (GFH). Water research 38(18), 4002–4012. [DOI] [PubMed] [Google Scholar]
- Butler E, Silva A, Horton K, Rom Z, Chwatko M, Havasov A and McCutcheon JR 2013. Point of use water treatment with forward osmosis for emergency relief. Desalination 312, 23–30. [Google Scholar]
- Campos V and Büchler PM 2005. Removal of chromate from drinking water using powder carbon steel. Environmental Geology 47, 926–930. [Google Scholar]
- Carrière A, Brouillon M, Sauvé S, Bouchard MF and Barbeau B 2011. Performance of point-of-use devices to remove manganese from drinking water. Journal of Environmental Science and Health Part A 46(6), 601–607. [DOI] [PubMed] [Google Scholar]
- CBTech 2016. Carbon Block Buyer’s Guide. [Google Scholar]
- Chen AS, Wang L, Sorg TJ and Lytle DA 2020. Removing arsenic and co-occurring contaminants from drinking water by full-scale ion exchange and point-of-use/point-of-entry reverse osmosis systems. Water research 172, 115455. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chen B, Jiang J, Yang X, Zhang X and Westerhoff P 2021. Roles and knowledge gaps of point-of-use technologies for mitigating health risks from disinfection byproducts in tap water: a critical review. Water research 200, 117265. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Eichelberger J, Budde-Revision W, Munch J and Bellar-Revision T 1995. Method 524.2 measurement of purgeable organic compounds in water by capillary column gas chromatography/mass spectrometry. National Exposure Research laboratory, US EPA 524. [Google Scholar]
- Farsad A, Marcos-Hernandez M, Sinha S and Westerhoff P 2023a. Sous Vide-Inspired Impregnation of Amorphous Titanium (Hydr)Oxide into Carbon Block Point-of-Use Filters for Arsenic Removal from Water. Environmental Science & Technology 57(48), 20410–20420. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Farsad A, Niimi K, Ersan MS, Gonzalez-Rodriguez JR, Hristovski KD and Westerhoff P 2023b. Mechanistic Study of Arsenate Adsorption onto Different Amorphous Grades of Titanium (Hydr)Oxides Impregnated into a Point-of-Use Activated Carbon Block. ACS ES&T Engineering 3(7), 989–1000. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hailemariam RH, Choi J-S, Damtie MM, Rho H, Park K-D, Lee J and Woo YC 2022. Enhancing performances of polyamide thin film composite membranes via co-solvent assisted interfacial polymerization. Desalination 524, 115481. [Google Scholar]
- Lau BL, Harrington GW, Anderson MA and Tejedor I 2005. Physicochemical aspects of Cryptosporidium surrogate removal in carbon block filtration. Journal-American Water Works Association 97(2), 92–101. [Google Scholar]
- Lui GY, Roser D, Corkish R, Ashbolt NJ and Stuetz R 2016. Point-of-use water disinfection using ultraviolet and visible light-emitting diodes. Science of the total environment 553, 626–635. [DOI] [PubMed] [Google Scholar]
- Mecha C and Pillay VL 2014. Development and evaluation of woven fabric microfiltration membranes impregnated with silver nanoparticles for potable water treatment. Journal of membrane science 458, 149–156. [Google Scholar]
- NSFInternationalStandard 2017. Standards for Water Treatment Systems. [Google Scholar]
- Pratson E, Vengosh A, Dwyer G, Pratson L and Klein E 2010. The effectiveness of arsenic remediation from groundwater in a private home. Groundwater Monitoring & Remediation 30(1), 87–93. [Google Scholar]
- Rho H, Kim S, Shin J, Cho J, Lee Y-G and Chon K 2022a. Effects of two-step cleaning sequences on foulant extraction from multibore ultrafiltration membranes in a pilot-scale membrane filtration system for surface water treatment. Chemosphere 297, 134164. [DOI] [PubMed] [Google Scholar]
- Rho H, Yu P, Zhao Z, Lee C-S, Chon K, Perreault F, Alvarez PJ, Amy G and Westerhoff P 2022b. Inhibition of biofouling on reverse osmosis membrane surfaces by germicidal ultraviolet light side-emitting optical fibers. Water Research 224, 119094. [DOI] [PubMed] [Google Scholar]
- Richard R, Hamilton KA, Westerhoff P and Boyer TH 2020. Tracking copper, chlorine, and occupancy in a new, multi-story, institutional green building. Environmental Science: Water Research & Technology 6(6), 1672–1680. [Google Scholar]
- Rizzo L, Koch J, Belgiorno V and Anderson M 2007. Removal of methylene blue in a photocatalytic reactor using polymethylmethacrylate supported TiO2 nanofilm. Desalination 211(1-3), 1–9. [Google Scholar]
- Saetta D, Richard R, Leyva C, Westerhoff P and Boyer TH 2021. Data-mining methods predict chlorine residuals in premise plumbing using low-cost sensors. AWWA Water Science 3(1), e1214. [Google Scholar]
- Silverstein I 2006. Investigation of the capability of point-of-use/point-of-entry treatment devices as a means of providing water security. EPA Rep, 1–54. [Google Scholar]
- Traegner U and Suidan M 1989. Parameter evaluation for carbon adsorption. Journal of Environmental Engineering 115(1), 109–128. [Google Scholar]
- Tsai J-H, Chiang H-M, Huang G-Y and Chiang H-L 2008. Adsorption characteristics of acetone, chloroform and acetonitrile on sludge-derived adsorbent, commercial granular activated carbon and activated carbon fibers. Journal of Hazardous Materials 154(1), 1183–1191. [DOI] [PubMed] [Google Scholar]
- Van Dyke K, Kuennen R, Stiles J, Wezeman J and O’Neal J 1986. Test stand design and testing for a pressed carbon block water filter. American Laboratory 18(9), 118-&. [Google Scholar]
- Wang Z, Bi X, He X, Xie Y, Lin J and Deng B 2023. A two-sorbent system for fast uptake of arsenate from water: Batch and column studies. Water Research 228, 119290. [DOI] [PubMed] [Google Scholar]
- Wood L 2024. Point of Use Water Treatment Systems Market to Hit USD 53.56 Billion by 2030 with Reverse Osmosis Technology Spearheading Growth, GlobeNewswire, Research and Markets. [Google Scholar]
- Wu B, Christen T, Tan HS, Hochstrasser F, Suwarno SR, Liu X, Chong TH, Burkhardt M, Pronk W and Fane AG 2017. Improved performance of gravity-driven membrane filtration for seawater pretreatment: implications of membrane module configuration. Water research 114, 59–68. [DOI] [PubMed] [Google Scholar]
- Xia S, Dong B, Zhang Q, Xu B, Gao N and Causseranda C 2007. Study of arsenic removal by nanofiltration and its application in China. Desalination 204(1-3), 374–379. [Google Scholar]
- Xiang W, Zhang X, Chen K, Fang J, He F, Hu X, Tsang DC, Ok YS and Gao B 2020. Enhanced adsorption performance and governing mechanisms of ball-milled biochar for the removal of volatile organic compounds (VOCs). Chemical Engineering Journal 385, 123842. [Google Scholar]
- Yan X-P, Kerrich R and Hendry MJ 1998. Determination of (ultra) trace amounts of arsenic (III) and arsenic (V) in water by inductively coupled plasma mass spectrometry coupled with flow injection on-line sorption preconcentration and separation in a knotted reactor. Analytical chemistry 70(22), 4736–4742. [DOI] [PubMed] [Google Scholar]
- Zhao Z, Lanzarini-Lopes M, Westerhoff E, Long X, Rho H, Bi Y, Ling L and Westerhoff P 2021. Evanescent wave interactions with nanoparticles on optical fiber modulate side emission of germicidal ultraviolet light. Environmental Science: Nano 8(9), 2441–2452. [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.