Abstract
Background
The use of wearable devices for remote health monitoring is a rapidly expanding field. These devices might benefit patients and providers; however, they are not yet widely used in healthcare. This scoping review assesses the current state of the literature on wearable devices for remote health monitoring in non-hospital settings.
Methods
CINAHL, Scopus, Embase and MEDLINE were searched until August 5, 2024. We performed citation searching and searched Google Scholar. Studies on wearable devices in an outpatient setting with a clinically relevant, measurable outcome were included and were categorized according to intended use of data: monitoring of existing disease vs. diagnosis of new disease.
Results
Eighty studies met eligibility criteria. Most studies used device data to monitor a chronic disease (68/80, 85%), most often neurodegenerative (22/68, 32%). Twelve studies (12/80, 15%) used device data to diagnose new disease, majority being cardiovascular (9/12, 75%). A range of wearable devices were studied with watches and bracelets being most common (50/80, 63%). Only six studies (8%) were randomized controlled trials, four of which (67%) showed evidence of positive clinical impact. Feasibility determinants were inconsistently reported, including compliance (51/80, 64%), patient-reported useability (13/80, 16%), and participant technology literacy (1/80, 1%).
Conclusions
Evidence for clinical effectiveness of wearable devices remains scant. Heterogeneity across studies in terms of devices, disease targets and monitoring protocols makes data synthesis challenging, especially given the rapid pace of technical innovation. These findings provide direction for future research and implementation of wearable devices in healthcare.
Author summary
Wearable devices, such as smartwatches, have potential to benefit patients and assist healthcare workers; however, these devices are not yet widely used in healthcare. This review looks at existing research around wearable devices used to monitor health markers outside of the hospital. We worked with a research librarian to comprehensively search online databases until August 5, 2024. Studies on use of wearable devices outside of a hospital setting with clinically relevant, measurable outcomes were included and sorted by whether they used data to monitor an existing disease or identify a new disease. We included 80 studies: most focused on monitoring existing chronic diseases (68/80, 85%), while the minority looked at identifying a new disease (12/80, 15%). Many different wearable devices were investigated in these studies. A small proportion (6/80, 8%) of the studies were randomized controlled trials. Four of these six studies (67%) showed a positive clinical impact. We also found that feasibility information was reported inconsistently. There is limited evidence for the clinical effectiveness of wearable devices. Studies varied on device used, disease target, and monitoring protocol, making it difficult to draw conclusions based on this literature, especially since the technology is rapidly evolving.
Introduction
The global market for wearable electronics was estimated at US$32.5 billion in 2022 and is projected to reach US$173.7 billion by 2030, growing at an annual rate of 23.3% over this period [1]. These devices can measure an expanding array of biometrics, including heart rate, blood pressure, and oxygen saturation, and more [2]. They are increasingly integrated with daily life, offering new ways to monitor health unobtrusively for large, distributed populations [2–5]. Remote health monitoring (RHM) is rapidly gaining interest in healthcare research, leveraging wearable technologies, like smartwatches, to track health status in non-hospital environments [3,6]. In some contexts, RHM has been shown to shorten hospital stays [7], reduce hospital readmissions [8], lower healthcare costs [9], and decrease clinician burnout [10].
Despite immense potential, real-world implementations of RHM with wearable devices remain limited. Most published use-cases are for the most common, chronic diseases like diabetes, hypertension, chronic obstructive pulmonary disorder (COPD) or congestive heart failure (CHF), and evidence for effectiveness is conflicting [6]. Further, available data are derived from a diverse set of devices, many of which are now out of date, in a range of patient populations, using different biometric parameters and disease outcomes [3]. Researchers are increasingly exploring wearable devices to improve health outcomes across a broad range of disease contexts. While recent reviews have examined clinical applications of wearables, they primarily focus on chronic disease [11,12]. Given the rapid evolution of wearable technologies and the growing number of potential use cases, there is a need to update existing reviews to include non-chronic conditions and provide a more comprehensive overview of their potential impact.
We therefore performed a scoping review exploring the current clinical applications for wearable devices and RHM for non-hospital settings, summarizing evidence specifically on the impact on patient outcomes, investigating for actual change in these outcomes due to use of a wearable device.
Methods
The protocol for this scoping review was published on Open Science Framework (https://doi.org/10.17605/OSF.IO/AT7VS). We followed Arksey and O’Malley’s guidelines for scoping review methods [13].
Eligibility criteria
The inclusion and exclusion criteria for this scoping review (Table 1) were developed around the PCC (population, concept, context) framework, as per the Joanna Briggs Institute for scoping reviews [14]. We targeted an adult population, excluding studies including patients under 18 years of age. For inclusion, studies needed to use a wearable device to monitor disease. Therefore, studies including solely healthy subjects were excluded. Wearable devices had to meet the following definition based on Gao et al. 2016: devices that can be worn on human skin to continuously and closely monitor an individual’s activities, without interrupting or limiting the user’s motions” [5]. Examples include smartwatches and wearable textiles/clothing with embedded sensors.
Table 1. Study eligibility criteria, based on the PCC framework (Population, Concept, Context), as recommended by the Joanna Briggs Institute for Scoping Reviews [14].
| Inclusion criteria | Exclusion criteria | |
|---|---|---|
| Population | • Adults (18 years of age and above) | • Children (under 18 years of age) |
| Concept | • Wearable devices (according to a commonly used definition (5)) for remote health monitoring • Disease monitoring (changes in an existing disease or detection of a new disease) • Clinically relevant, measurable outcome |
• Any technology that does not meet the definition for a wearable device • Healthy subjects |
| Context | • Outpatient monitoring | • Inpatient monitoring |
| Study design | • Randomized controlled trials • Longitudinal studies • Observational studies |
• Conference proceedings • Abstracts • Validation studies • Opinion pieces • Cross-sectional studies |
| Language | • Studies written in the English language | • Studies that were not written in the English language |
We focused on outpatient or non-hospital RHM, excluding studies with hospitalized populations and long-term care facilities. This was done for two main reasons: 1) our primary interest was in settings where clinical teams are less able to support patients in their use of technology for more accurate data on usability and acceptability; and 2) to increase feasibility of the search given an expansive literature base. We also excluded studies with implantable devices, such as blood glucose monitors because they do not meet our definition for ‘wearable’ [5]. All trial designs were eligible, including randomized controlled trials, longitudinal studies, feasibility studies, and observational studies. We focused on studies that measured a clinical outcome, and therefore validation studies were excluded. Conference proceedings, opinion pieces, reviews, and cross-sectional studies were also excluded. Only studies written in the English language were included as we did not have the resources to support a translation service.
Search strategy and study selection
A research librarian (coauthor LD) assisted in designing our search strategy. We searched the following electronic databases from inception to August 5, 2024: CINAHL (1937-present), Scopus (2004-present), Embase (1974-present) and MEDLINE (1946-present via OVID). Our search strategy for MEDLINE is shown in S1 File. This search strategy was translated for use in the other databases. We searched Google Scholar on January 23, 2024. Covidence Systematic Review software [15] was used for study screening. Two reviewers (KL, MW) independently screened studies at both the title/abstract and full text stages. A third reviewer (JH) was involved to resolve conflicts. Citation searching was performed for included studies.
Data extraction and analysis
A data extraction spreadsheet was developed based on the review question and PCC. Two reviewers (KL, MW) completed data extraction. Extracted data included study characteristics (e.g., study design, mean participant age, country), wearable device information (device name, company, sensor type, body part, length of monitoring, instructions on use, frequency of removal, and technical support, and parameters monitored), control group (where applicable), and study findings (including clinical and economic outcomes, protocol compliance, device useability and feasibility).
Results
Search results and study selection
Fig 1 shows the PRISMA flow diagram summarizing search results and study selection. Our search identified 3980 studies after the removal of duplicates. Title and abstract screening resulted narrowed this to 386 studies for full-text screening; the final sample included 80 studies that met our eligibility criteria.
Fig 1. PRISMA flow diagram outlining the study selection process, including reasons for exclusion at the full text review stage.
Study characteristics
Table 2 provides a summary of key study characteristics of the included studies, categorized by disease category (i.e., body system) and outcome type (i.e., monitoring of existing disease or diagnosis of new disease). The oldest study was published in 2001, with the majority of included studies published between 2019 and 2024 (51 studies, 64%). The most frequent study location was the United States of America (40 studies, 50%), followed by the UK (10 studies, 13%) and the Netherlands (8 studies, 10%). Only three studies (4%) reported including rural patients. Six of the included studies were randomized controlled trials (RCTs) (8%). Control groups were present in 22 studies (28%).
Table 2. Summary of main study characteristics for each included study (n = 80).
| Monitoring disease | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Study | Country | Study design | Control | Sample size | Age | Disorder/ monitored parameter(s) | Monitoring length | Wearable device name | Summary of main finding(s) related to clinical outcomes | |
| Cardiovascular disease | ||||||||||
| [16] | Garcia et al., 2023 | France | Prospective, Cohort | No | 1013 | 61 | Heart failure/ nocturnal heart rate | Median 68 days | LifeVest, external defibrillator | High nocturnal heart rate was significantly associated with the primary endpoint (a composite of cardiovascular death and heart failure-related hospitalization). |
| [17] | Kim et al., 2020 | Korea | Prospective, non- randomized, interventional | No | 110 | N/R | Stroke/ blood pressure, physical activity | 12 weeks | Bluetooth sphygmomanometer, wrist-worn smart band | 26 patients with uncontrolled blood pressure experienced a decrease in blood pressure. |
| [18] | Kolk et al., 2023 | Netherlands, Denmark | Prospective, observational | No | 303 | 62.9 | Ischaemic cardiomyopathy, heart failure/ activity, sleep, step count | 6 months | GENEActiv accelerometer | Digital biomarkers showed significant correlations to patient-reported physical and social limitations, severity and frequency of symptoms and quality of life. |
| [19] | Okumus et al., 2018 | Turkey | Observational | No | 38 | 50 | Pulmonary hypertension/ daily activity and energy expenditure | N/R | Senseband | Significant correlations between items of the Nottingham extended activity of daily living index and activity monitor data. |
| [20] | Pothineni et al., 2022 | USA | Cohort | No | 20 | 64 | Stroke/ ECG | 2 weeks | ZIO XT patch | Arrhythmias were observed in 2/3 of patients recovering from stroke. |
| [21] | Rosenberg et al., 2013 | USA | Comparative study | No | 74 | 65 | Atrial fibrillation/ ECG | 2 weeks | Zio XT Patch | All atrial fibrillation episodes were recorded on the Holter and the wearable. The wearable detected significantly more AF episodes than the Holter due to a longer monitoring time. The wearable also detected other arrhythmias. |
| [22] | Stehlik et al., 2020 | USA | Observational | No | 100 | 68 | Heart failure/ ECG, temperature, accelerometry data, skin impedance | 3 months | Vital Connect | Combination of device parameters detected precursors of hospitalization for heart failure exacerbation with high sensitivity and specificity. |
| [23] | Stollfuss et al., 2021 | Germany | Prospective, cohort, observational | No | 31 | N/R | Pulmonary arterial hypertension/ steps, distance walked, heart rate, motion | 3 months | Apple Watch Series 2 | Daily physical activity increased during the study and so did 6-minute walk distance. |
| [24] | Tung et al., 2014 | USA | Observational | No | N/R | 68 | Stroke, transient ischemic attack/ ECG | 2 weeks | ZIO patch | The wearable device accurately captured atrial fibrillation burden in patients recovering from a stroke. |
| Diabetes | ||||||||||
| [25] | Abbott et al., 2019 | UK | Prospective, RCT | Yes | 58 | 59* | Diabetic foot ulcers/ plantar pressure | N/R | SurroSense Rx | The intervention group received alerts and offloading instructions, leading to a 71% reduction in ulcer incidence. |
| [26] | Armstrong et al., 2004 | USA | Prospective, longitudinal | No | 100 | 69 | Diabetic foot ulcers/ steps taken over a period of time | 25 weeks | Biotrainer Pro | Average daily activity was significantly lower in participants who ulcerated compared to those who did not ulcerate. No significant difference in average daily activity during that period. |
| [27] | Najafi et al., 2017 | USA | Prospective, cohort | No | 17 | 62 | Diabetic foot ulcers/ plantar pressure | 3 months | SurroSense Rx | Participants who received at least 1 alert every 2 hours were more adherent with offloading and successfully offloaded faster than those who received fewer alerts. |
| [28] | Reyzelman et al., 2018 | USA | Case studies, observational | No | 34 | 62 | Diabetic foot ulcers/ foot temperature | 1 week | Siren Diabetic Socks | Temperature measurements from the socks were consistent with initial observations and medical history. |
| Cancer | ||||||||||
| [29] | Dadhania et al., 2023 | UK | Cohort | Yes | 42 | N/R | High grade glioma/ accelerometer | Median 49 days | Axivity AX3 triaxial accelerometer | Mean acceleration and daily time spent walking correlated positively with global health quality of life and physical functioning scores and inversely with the fatigue score. |
| [30] | Gresham et al., 2018 | USA | Prospective, single cohort | No | 37 | N/R | Cancer (stage 3 or 4 pancreatic, colorectal, other gastrointestinal, gynecological, or lung cancer)/ steps, distance, flights of stairs | 2 weeks | Fitbit Charge HR | Correlations were observed between average daily steps and measures of patient functioning and ability of self-care. Increases of 1000 steps were associated with reduced odds for adverse events, hospitalizations, and hazard for death. |
| [31] | Korde et al., 2023 | USA | Prospective, observational, cohort | No | 40 | 41-82 | Multiple myeloma/ continuous activity | 6 months | Garmin Vivofit | Overall activity trended upward cycle over cycle for the entire study cohort. Activity trends associated with improvement of electronic patient reported outcome domains, including physical functioning scores, global health scores, and declining disease burden symptom scores. |
| [32] | Low et al., 2017 | USA | Exploratory | No | 14 | 60 | Gastrointestinal cancer/ activity and sleep metrics | 4 weeks | Fitbit Charge HR | Increased symptom burden was associated with reduced mobility and sleep (more sleep and increased periods of waking). |
| [32] | Low et al., 2021 | USA | Prospective, longitudinal | No | 44 | 66 | Surgery for pancreatic cancer/ step count, distance traveled | 12 weeks | Fitbit Charge 2 | Predicted next-day diarrhea, fatigue and pain with high accuracy. |
| [33] | Low et al., 2024 | USA | Prospective, longitudinal | No | 40 | 73.35 | Any cancer/ activity metrics, time spent at home | Mean 26 days | Fitbit inspire 3 | More walking, faster speeds and smoother movement were linked to better physical function. After adjusting for age and health conditions, these device parameters still showed a connection to physical function, and peak walking speed was associated with fall risk. |
| [34] | Ohri et al., 2019 | USA | Prospective | No | 50 | N/R | Locally advanced non-small cell lung cancer | N/R | Garmin Vivofit | Inactive participants were more likely to be hospitalized and less likely to complete radiation therapy without delay exceeding 1 week. |
| Renal disease | ||||||||||
| [35] | Cohen et al., 2022 | USA | Pilot | No | 48 | 60 | End stage kidney disease/ step count | 6 months | Garmin Vivofit 2 | Step count was lower on dialysis days. Step count was higher in the hour following dialysis, and these increases were greater in patients with a fast recovery time or a high short physical performance battery score. |
| [36] | Lunney et al., 2021 | Canada | Prospective observational cohort feasibility study | No | 46 | N/R | Kidney failure/ daily step count | 4 weeks | Fitbit Alta | No association between step count and the occurrence of clinical events, although the number of events was very small. |
| Respiratory diseases | ||||||||||
| [37] | Drent et al., 2020 | Netherlands | Prospective, cohort | Yes | 149 | N/R | Sarcoidosis/ Number of steps, estimated distance, number of flights climbed, activity minutes | 12 weeks | Fitbit Charge HR | Exercise capacity increased to a greater extent in the physical activity group compared to the control group.. |
| [38] | Hawthorne et al., 2022 | UK | Prospective, cohort, observational | No | 31 | N/R | COPD/ respiratory rate, heart rate, skin temperature, physical activity | 6 weeks | Equivital EQ02 + LifeMonitor | Increased heart rate and reduced physical activity were associated with worsening symptoms. |
| [39] | Orme et al., 2018 | UK | RCT | No | 33 | N/R | COPD/ sitting time, stand-ups, steps | 2 weeks | N/R | Step count increased, but stationary time and physical activity did not. No statistically significant change in COPD symptoms, fatigue, anxiety or fear of falling. Severe fatigue decreased. |
| [40] | Pedone et al., 2013 | Italy | RCT | Yes | 99 | 74 | COPD/ heart rate, physical activity, near-body temperature, galvanic skin response | 9 months | SweetAge monitoring system wristband, pulse oximeter | Incidence rate of respiratory events was lower in the telemonitoring group. |
| [41] | Rubio et al., 2017 | UK | Observational | No | 18 | 72 | COPD/ breathing rate | 6 weeks | Chest-band | A reduction in resting breathing rate during the recovery from an acute exacerbation of COPD was observed in some but not all participants and there was considerable day-to-day individual variation. |
| [42] | Tabak et al., 2014 | Netherlands | Pilot RCT | Yes | 30 | 65* | COPD/ steps per day | 4 weeks | MTx-W sensor | Wearable device data provided alerts around physical activity levels. There was a non-significant difference in improvement in health status between the monitored and usual care groups. |
| [43] | Wu et al., 2021 | Taiwan | Prospective, cohort | No | 67 | 67 | COPD/ walking steps, climbing stairs, distances, consumption in calories, heart rate, sleep status | 4 months | Fitbit Versa | Device data predicted acute exacerbation of COPD by 7-days (92.1% accuracy). The most important variables in the model were daily steps walked, stairs climbed, and daily distance moved. |
| [44] | Wurzer et al., 2021 | Germany | Feasibility | No | 153 | – | COVID-19/ oxygen saturation, respiratory rate, heart rate, temperature | 9 days median | Cosinuss One in-ear sensor | There was a lower SpO2 before hospitalization than for participants who were not hospitalized. |
| [45] | Yamagami et al., 2021 | Japan | Prospective | No | 23 | 51 | COVID-19/ resting heart rate, sleep quality, steps, physical activity, sleep quality, estimated oxygen variation | 30 days | Fitbit Charge 3 | Oxygen saturation on device correlated with COVID-19 symptom severity. |
| Musculoskeletal disorders | ||||||||||
| [46] | Gurchiek et al., 2019 | USA | Observational | Yes | 28 | 26* | Anterior cruciate ligament surgery/ gait, daily step count | 17 weeks | BioStamp | Asymmetry indices (measured with the wearable device) were more strongly correlated with recovery time than standard step counts. Asymmetry indices were significantly different between patients and controls. |
| [47] | Maharaj et al., 2022 | Australia | Prospective, observational | No | 50 | 24 | Spine surgery for lumbar spinal stenosis or degenerative spondylolisthesis/ step count, distance traveled | 12 weeks | Mi Band 2 smartwatch | Mean daily step count and daily walking distance significantly improved over postoperative course. |
| [48] | Patterson et al., 2020 | USA | Prospective, cohort, observational | No | 20 | 63 | Total joint arthroplasty (hip, knee)/ steps, distance, floors climbed, calories expended, active minutes | 8 weeks | Fitbit Flex | Decreased activity group reported greater clinically relevant pain reduction. |
| [49] | Perraudin et al., 2018 | Ireland | Observational | Yes | 45 | N/R | Arthritis/ movement | 4 weeks | Actigraph GT9X Link | Five times sit to stand test performance (time to complete) was associated with pain and stiffness intensity. |
| [50] | Scheer et al., 2017 | USA | Prospective, cohort | No | 32 | 58 | Surgery for spinal deformity or degenerative disease/ number of daily steps, max hourly steps, activity intensity | 6 months | Fitbit Flex | Health-related quality of life measures were correlated with preoperative average daily steps, but not with post-operative steps. |
| [51] | Toogood et al., 2016 | USA | Prospective, cohort | No | 33 | 71 | Total hip arthroplasty/ mean daily step count | 30 days | Fitbit | Number of steps correlated with recovery time. Age and an anterior surgical approach were associated with increased activity. |
| Neurodegenerative disorders | ||||||||||
| [52] | Block et al., 2016 | USA | Prospective, cohort, observational, longitudinal | No | 80 | 50 | Multiple sclerosis/ step count | 4 weeks | Fitbit Flex | Greater MS disability associated with lower daily step count. |
| 50 | 48 | 6 months | Greater MS disability associated with lower average daily step count. | |||||||
| [53] | Block et al., 2017 | USA | Prospective, cohort, RCT | Yes | 99 | 50* | Multiple sclerosis/ step count | 4 weeks | Fitbit Flex 2 | Negative correlation between disability level and step count. |
| [54] | Block et al., 2019 | USA | Prospective, cohort, observational, longitudinal | No | 95 | 50 | Multiple sclerosis/ step count | 1 year | Fitbit Flex | Greater MS disability associated with lower average daily step count. |
| [55] | Block et al., 2021 | USA | RCT | Yes | 21 | 48* | Multiple sclerosis/ step count | 12 weeks | Fitbit Flex | Monitoring led to better adherence to clinical recommendations. |
| [56] | Burq et al., 2021 | Netherlands | Prospective, longitudinal | No | 388 | 63 | Parkinson’s disease/ motor signs | 1 year | Verily Study Watch 2nd Generation | Smartwatch measurements were correlated with rest tremor, bradykinesia, and gait. |
| [57] | Caballol et al., 2023 | Spain | Prospective, observational | Yes | 39 | 69 | Parkinson’s disease/ movement | 1 week before treatment, 1 week 3 months after therapeutic changes | STAT-ONTM system | Device data correlated with on-time, off-time, number of steps, gait fluidity, motor fluctuations, dyskinesia, and freezing of gait, in agreement with clinical measures. |
| [58] | Cereda et al., 2010 | Italy | Prospective, crossover | Yes | 6 | N/R | Parkinson’s disease/ total energy expenditure, physical activity, number of steps, metabolic rate | 2 weeks | SenseWear Armband | Wearable measurements correlated with dyskinesias; no correlation with number of steps for participants who ate a low-protein diet. |
| [59] | Dalla Costa et al., 2024 | Italy, Spain, Denmark | Observational | No | 306 | 45.6 | Multiple Sclerosis/ daily steps | 2 years | Fitbit charge 3 | Daily steps recorded by the Fitbit is inversely correlated with EDSS (disability) score. |
| [60] | Davies et al., 2020 | USA | Prospective, observational | No | 8 | 44 | Tay-Sachs and Sandhoff disease/ average daily maximum, average daily steps, average daily steps per 30-minute epoch | 6 months | Wristwatch | Negative correlation between disease impact/severity and wearable metrics. |
| [61] | Fay-Karmon et al., 2024 | N/R | Observational | No | 21 | 66.1 | Parkinson’s disease/ tremor, dyskinesia, level of activity | 2 weeks | Apple watch series 4 | Differences among individual symptoms’, including levodopa-related variations, led to grouping of participants into four data-driven profiles. |
| [62] | Gordon et al., 2019 | N/R | Observational | No | 15 | N/R | Huntington’s disease/ movement | 6 months | Smartwatch | Correlation between device data and patient-reported chorea score. Model including device data predicted chorea severity. |
| [63] | Joshi et al., 2019 | USA | Observational | No | 63 | N/R | Parkinson’s disease/ movement | 6 days | Personal KinetiGraph system | The wearable device detected bradykinesia or dyskinesia despite patients not reporting these symptoms and improved patient-provider communication, ability to assess treatment impact and motor assessments. |
| [64] | Klassen et al., 2007 | Canada | Exploratory, descriptive | Yes | 39 | N/R | Multiple sclerosis/ accelerometer data | 4 days | TriTrac RT3 accelerometer | Accelerometer scores were significantly correlated with neurological status and disease severity. |
| [65] | Kotschet et al., 2022 | Australia | Feasibility | No | 25 | 60 | Parkinson’s disease/ movement | 6 days | Parkinson’s KinetiGraph system | Correlations observed between wearable data and chorea and bradykinesia scores. |
| [66] | Kratz et al., 2019 | USA | Observational | No | 107 | N/R | Multiple Sclerosis/ physical activity | 7 days | PRO-Diary | Increased fatigue and depressed mood were associated with reduced physical activity. Physical activity was not associated with pain or cognitive symptoms. |
| [67] | Mancini et al., 2015 | USA | Feasibility | Yes | 32 | 65* | Parkinson’s disease/ turning (velocity, steps) | 1 week | Opal inertial sensors | Turn velocity and number of steps per turn were correlated with symptom rating scale (motor score). |
| [68] | Motl et al., 2011 | USA | Observational | No | 292 | N/R | Multiple sclerosis/ physical activity | 1 week, 1 week after 6 months | ActiGraph | Associations were observed between baseline and 6-month physical activity and disability. |
| [69] | Powers et al., 2021 | USA | Longitudinal, cohort | Yes | 396 | 71 | Parkinson’s disease/ movement | 6 months | Smartwatch | Wearable measurements were correlated with tremor severity and with expert ratings of dyskinesia. |
| [70] | Shammas et al., 2014 | Germany | Pilot study, prospective | No | 11 | N/R | Multiple Sclerosis/ step count, maximum walking speed, physical activity intensity | 1 year | Activity sensor | Patients with moderate disability took less steps and had slower walking speed than those with mild disability. |
| [71] | vanVugt et al., 2001 | Netherlands | Observational | Yes | 131 | 45* | Huntington’s disease/ daytime motor activity | 5 days | Wrist-worn activity monitor | Daytime activity was decreased in patients compared to healthy controls. Hypokinesia correlated with impaired voluntary movements, disturbed gait and posture, and reduced functional capacity, progression of functional disability. |
| [72] | Weiss et al., 2014 | Israel | Longitudinal, observational | Yes | 107 | N/R | Parkinson’s disease/ variability of the gait pattern, gait rhythmicity and consistency and gait smoothness | 3 days | DynaPort Hybrid system | Device parameters correlated with validated measures of fall risk. Wearable data predicted time to first fall. |
| [73] | Woelfle et al., 2023 | Switzerland | Longitudinal, observational | Yes | 28 | N/R | Multiple Sclerosis/ steps, activity, calories, heart rate, sleep | 6 weeks | Fitbit Versa 2 smartwatch | Device parameters correlated with 3 clinical reference tests (the expanded disability status scale, timed 25-foot walk, MS-walking scale). |
| Psychiatric disorders | ||||||||||
| [74] | Alinia et al., 2021 | USA | Proof of concept | No | 11 | 40 | Stress, EtOH cravings, pain, discomfort/ ANS arousal, heart rate, heart rate variability, interbeat interval | 2 weeks | Empatica E4 | Electrodermal activity and heart rate variability were correlated with outcomes, including self-reported stress positive and negative emotions, and pain and discomfort. |
| [75] | Carreiro et al., 2020 | USA | Observational | No | 31 | 32 | Substance use disorder/ electrodermal activity, skin temperature, acceleration, heart rate | 4 days | E4 wearable sensor | Device parameters associated with patient-reported stress and craving.. |
| [76] | Knight et al., 2018 | Australia | Prospective, cohort, observational | No | 53 | 21 | Depression, anxiety/ daily activity duration | 8 months | Fitbit, Garmin | Correlations observed between anxiety and emotional volatility scores and daily activity over 45 days of measurement. |
| [77] | Lahti et al., 2021 | USA | Observational | No | 40 | 40 | Schizophrenia/ sleep-wake, activity count, light exposure, step count | 4 months | Philips Actiwatch, Garmin Vivofit wristband | Wearable data and psychotic symptoms were correlated. |
| [78] | Lee et al., 2022 | South Korea | Prospective, cohort | No | 270 | 23 | Major depressive disorder, bipolar disorder/ heart rate and motion | Average 280 days | Fitbit Charge HR 2 or 3 | Device metrics predicted onset of depression episodes. |
| [79] | Mahoney et al., 2023 | USA | Prospective | No | 77 | 37.3 | Substance use disorder/ heart rate, blood oxygen saturation, stress, activity, sleep | 1 year | Garmin vivosmart 4 | Physiological markers were significantly elevated in the week prior to drug use recurrence relative to periods of sustained abstinence. |
| [80] | O’Brien et al., 2017 | UK | Observational | Yes | 59 | 74* | Depression/ physical activity | 7 days | Wrist-worn device | Physical activity and fine motor movement speed was associated with depression, quality of life, and associative learning. |
| [81] | Sun et al., 2023 | UK, Spain, Netherlands | Longitudinal, observational | No | 623 | 49 | Major depressive disorder/ sleep metrics | Median 312 days | Fitbit Charge 2 or 3 | Sleep onset and wakefulness correlated with PHQ-8 (patient health questionnaire for depressive symptoms) |
| [82] | Zhang et al., 2021 | UK, Netherlands, Spain | Longitudinal, observational | No | 368 | N/R | Major depressive disorder/ N/R | N/R | Fitbit Charge 2 or 3 | Sleep features were associated with depressive symptoms. |
| Identification of new diseases | ||||||||||
| Study | Country | Study design | Control | Sample size | Age | Disorder/ monitored parameter(s) | Monitoring length | Wearable device name | Summary of main findings | |
| Cardiovascular disease | ||||||||||
| [83] | Ha et al., 2021 | Canada | Prospective, open-label RCT | Yes | 336 | 67 | Atrial fibrillation/ ECG | 30 days | SEEQ system (Medtronic), CardioSTAT system (Icentia) | Cumulative arrythmia burden was more monitored patients vs. usual care |
| [84] | Moshe et al., 2021 | Germany | Longitudinal, observational | No | 55 | 43 | Depression, anxiety/ step count, metabolic equivalent for class, sleep | 30 days | Oura ring | Sleep metrics were associated with depression. Heart rate variability was associated with anxiety. Combined data (wearable, self-reported mood and smartphone) provided the best prediction. |
| [85] | Pagola et al., 2023 | Spain | Prospective, observational | No | 224 | N/R | Cryptogenic stroke/ EGC | 90 days | Nuubo (textile wearable holter) | Accurate detection of paroxysmal atrial fibrillation compared to Holter.. o |
| [86] | Perez et al., 2023 | USA | Prospective, pragmatic study | No | 419297 | N/R | Atrial fibrillation/ changes in blood flow, ECG | N/R | Apple watch, ECG patch | The ECG patch identified atrial fibrillation. |
| [87] | Rooney et al., 2019 | USA | Observational, cross-sectional | No | 2616 | 79 | Atrial fibrillation/ ECG | 2 weeks vs 4 weeks | Zio XT Patch | 78% more subclinical atrial fibrillation was detected by 4 weeks of monitoring vs 2 weeks of ECG monitoring. |
| [88] | Schreiber et al., 2014 | USA | Prospective, observational | No | 174 | 52 | Cardiac arrhythmia/ ECG | 2 weeks | Zio Patch | Diagnostic yield for cardiac arrhythmias with the wearable device was 63.2%. |
| [89] | Steinhubl et al., 2018 | USA | Observational, cohort | Yes | 15214 | 72 | Atrial fibrillation/ ECG | 2-4 weeks | iRhythm ZioXT, skin adhesive patch | Atrial fibrillation was identified more in monitored groups than unmonitored. Monitoring was associated with increased initiation of anticoagulants, outpatient cardiology visits, and primary care visits, but no difference in emergency departments and hospitalizations. |
| [90] | Tison et al., 2018 | USA | Cohort | No | 1617 | N/R | Arrhythmia/ heart rate, step count | N/R | Apple watch | The wearable detected atrial fibrillation against the reference standard 12-lead ECG. |
| [91] | Wouters et al., 2022 | Belgium | Prospective RCT | Yes | 40 | 69* | Cryptogenic stroke or transient ischemic attack/ photoplethysmography | 180 days | Smartwatch | Device detected atrial fibrillation and other arrhythmias that were confirmed in some participants. |
| Respiratory diseases | ||||||||||
| [92] | Mishra et al., 2020 | USA | Prospective | Yes | 5262 (32) | 44 | COVID-19/ heart rate, number of daily steps, time asleep | N/R | Smartwatches (Fitbits, Apple watches, Garmin, other) | Device detected COVID-19 before or at symptom onset. |
| [93] | Smarr et al., 2020 | USA, UK, Finland, Austria, Canada, Germany, Honduras, Italy, Netherlands, Norway, Sweden | Feasibility | No | 50 | 44 | COVID-19/ skin temperature | 65 days | Oura ring | Device detected temperature increases that correlated with self-reported fever. Wearable data showed that COVID-19 onset could be detected before first symptoms. |
| [94] | Radin et al., 2020 | USA | Population-based | No | 47249 | 43 | Influenza-like illness/ mean resting heart rate, mean sleep time | N/R | Fitbit | Fitbit data significantly improved influenza-like illness predictions. |
*age is for the experimental group only
Most of the included studies monitored changes in an existing disease (68 studies, 85%), while the remainder detected new diseases or risk factors for disease (12 studies, 15%). Of the 12 studies that identified new diseases, the majority were on cardiovascular (9/12, 75%), and the remainder were respiratory (3/12, 25%). Of the 68 studies that monitored an existing disease, the most common disease category was neurodegenerative disorders (22/68, 32%), followed by respiratory diseases (9/68, 13%), psychiatric disorders (9/68, 13%) and cardiac diseases and stroke (9/68, 13%). Other categories for existing disease were diabetes, cancer, musculoskeletal disorders, and renal disease.
Wearable devices
Table 2 lists wearable device names and monitoring lengths for each of the included studies. Fig 2 and Table 3 show device types and brands. S2 File contains detailed information on device name, model, company, and sensor type for each study, organized by wearable device type. Studies used many different wearable device types, models, brands, and sensors. Some studies did not include details on device name (6/80, 8%), model (38/80, 48%), brand (11/80, 14%), sensor type (24/80, 30%), or body part (14/80, 18%). The most common device types were watches and bracelets (50 studies, 63%), and the most frequently used brand was Fitbit (22 studies, 42%). A wide variety of parameters were measured across studies, including movement or activity (37 studies, 46%), step count (33 studies, 41%), heart rate (15 studies, 19%), ECG (10 studies, 13%), sleep-related parameters (10 studies, 13%), temperature (7 studies, 9%), breathing rate (3 studies, 4%), blood oxygen saturation (3 studies, 4%), and blood pressure (2 studies, 3%).
Fig 2. Device types.
Light blue indicates wrist-worn devices (72.3% of total devices), purple indicates chest band (1.2%), green indicates patch devices (9.6%), light pink indicates ring wearables (2.4%), dark pink indicates attachable devices (6.0%), yellow indicates insole devices (3.6%), red indicates garment devices (3.6%), and dark blue indicates wearable defibrillator (1,2%).
Table 3. Device types, models and brands used in the included studies.
| Device type | Device brand and model | Used in # of studies (%) |
|---|---|---|
| Wrist-worn | Wrist-worn, not specified | 11 (14%) |
| Senseband | 2 (3%) | |
| Apple Watch Series 2 | 3 (4%) | |
| Apple Watch Series 4 | 1 (1%) | |
| FitBit Charge HR | 3 (4%) | |
| FitBit Charge 2 | 3 (4%) | |
| FitBit Charge 3 | 3 (4%) | |
| FitBit Flex | 5 (6%) | |
| FitBit - unspecified | 4 (5%) | |
| FitBit Inspire 3 | 1 (1%) | |
| Garmin Vivofit 2 | 1 (1%) | |
| Gramin Vivofit | 3 (4%) | |
| Garmin Vivosmart 4 | 1 (1%) | |
| Garmin - unspecified | 1 (1%) | |
| Fitbit Alta | 1 (1%) | |
| SweetAge | 1 (1%) | |
| FitBit Versa | 2 (3%) | |
| Mi Band 2 smartwatch | 1 (1%) | |
| Actigraph GT9X Link | 2 (3%) | |
| Verily Study Watch 2nd Generation | 1 (1%) | |
| Personal KinetiGraph system | 2 (3%) | |
| TriTrac RT3 accelerometer | 1 (1%) | |
| PRO-Diary | 1 (1%) | |
| Opal inertial sensors | 1 (1%) | |
| Axixity AX3 triaxial accelerometer | 1 (1%) | |
| Empatica E4 | 2 (3%) | |
| GENE Activ accelerometer | 1 (1%) | |
| Philips Actiwatch | 1 (1%) | |
| Chest band | Chest band | 1 (1%) |
| Patch | ZIO | 5 (6%) |
| Vital Connect | 1 (1%) | |
| BioStamp | 1 (1%) | |
| iRhythm ZioXT | 1 (1%) | |
| Ring | Oura ring | 2 (3%) |
| Attachable sensor | MTx-W sensor | 1 (1%) |
| Cosinuss One in-ear sensor | 1 (1%) | |
| STAT-ONTM system | 1 (1%) | |
| DynaPort Hybrid system | 1 (1%) | |
| SEEQ system | 1 (1%) | |
| Insole | SurroSense Rx | 2 (3%) |
| BioTrainer Pro | 1 (1%) | |
| Garment | Siren Diabetic Socks | 1 (1%) |
| Equivital EQ02 + LifeMonitor | 1 (1%) | |
| Nuubo | 1 (1%) | |
| External Defibrillator | LifeVest | 1 (1%) |
Table 4 contains information on study methods related to wearable devices. Almost half of the included studies monitored participants for up to one month (33 studies, 41%). Seventeen studies (21%) monitored participants for one to three months, and 12 studies (15%) monitored participants for three to six months. Eight studies (10%) monitored participants for six months to one year. One study (1%) monitored patients for over one year. Forty-one of the included studies (51%) reported the onboarding instructions provided to participants, 25 studies (31%) included information on the frequency of device charging or removal from the body, and 13 studies (16%) included information on technical support with maintenance and setup of the device that was provided to study participants. One study (1%) used a device that required a prescription.
Table 4. Proportion of studies that reported details on monitoring protocols, compliance, useability, and technology literacy.
| Proportion of included studies | |
|---|---|
| Methods | |
| Instructions on device use | n = 41, 51% |
| Frequency of charging or removal from the body | n = 25, 31% |
| Technical support with maintenance/setup | n = 13, 16% |
| Results | |
| Compliance (device wear time, study dropout) | n = 51, 64% |
| Patient reported useability | n = 13, 16% |
| Technology literacy data | n = 1, 1% |
Findings of the included studies
A summary of outcome-related findings for each of the 80 included studies can be found in Table 1. Six of the studies (9%) were randomized controlled trials (RCTs), and four of these RCTs (4/6, 67%) showed a positive clinical impact, including evidence of improved patient outcomes resulting from device use. Observational studies used a wide range of wearable devices and health parameters for a diverse set of diseases. All but two observational studies (62/64, 97%) found at least one significant correlation between a device parameter and a clinical outcome of interest. Table 3 shows studies that reported findings related to compliance, useability, and participant technology literacy. Over half of the included studies (51 studies, 64%) reported study protocol compliance, including device wear time or study dropout. Patient-reported usability was reported in 13 studies (16%). Only one study (1%) assessed technology literacy among the participants.
Discussion
Remote health monitoring has the potential to improve healthcare significantly by enabeling continuous monitoring of fidrsdr pstsmryrtd in non-hospital settings, however, real-world impacts remain unproven. (8)(9)(10) In this review, we examined the current evidence for wearables in the medical realm, focusing on measurable effects on clinical outcomes. Building on prior work, we included a wide variety of disease contexts in non-hospital settings and a broadly inclusive set of devices.
The most commonly used devices in this review were watches and bracelets (50/80, 63%), with Fitbit Inc. being the most common brand (22/50, 42%). Wrist-worn devices offer key advantages in clinical settings due to their unobtrusive, comfortable design – similar to traditional wristwatches – which facilitates continuous wear during sleep and physical activity (3). This enables uninterrupted data collection and the potential for early detection of health anomalies [3]. Interestingly, some studies (6/80, 8%) also neglected to report the specific device model/brand using generic terms like “smartwatch”, “inclinometer”, or “wearable activity tracker”. Additional missing details included device model (38/80, 48%), manufacturer (11/80, 14%), sensor type (24/80, 30%), and body placement (14/80, 18%) (S2). Insufficient reporting of technical specifications limits cross-study comparisons and synthesis of findings.
Most included studies monitored an existing disease (68/80, 85%), while a smaller proportion aimed to diagnose a new disease (12/80, 15%). A wide variety of health conditions were monitored, including neurodegenerative disorders (22/68, 32%), respiratory disorders (9/68, 13%), psychiatric disorders (9/68, 13%), cardiac diseases and stroke (9/68, 13%), cancer (7/68, 10%) musculoskeletal disorders (6/68, 9%), diabetes (4/68, 6%), and renal disease (2/68, 3%). Among the studies targeting new disease diagnosis (12/80, 15%), two main categories emerged: cardiac diseases (9/12, 75%) and respiratory diseases (3/12, 25%).
Of the 80 studies included in this review, only six (6/80, 8%) were RCTs, focusing on diabetes (1/6, 17%) respiratory disorders (3/6, 50%), and neurodegenerative disorders (2/6, 33%). Four of these trials (4/6, 67%) showed a positive clinical impact, including evidence of improved patient outcomes associated with device use. Abbott et al (2019) demonstrated a 71% reduction in diabetic ulcer incidence with the use of SurroSense Rx, a smart insole system was used [25]. In COPD, Pedone et al (2013) reported a lower incidence of respiratory events in an experimental group monitored using a wristband tracking heart rate, physical activity, temperature and galvanic skin response, in combination with a commercial pulse-oximeter [40]. In multiple sclerosis (MS), Block et al (2021) found improved adherence to therapy recommendations in patients using a Fitbit Flex 2 but no improvements in disease symptoms [55]. Orme et al (2018) reported mixed effects for COPD using an inclinometer: no change in respiratory symptoms, but reduced fatigue levels [39]. Finally, Tabak et al (2014) found no difference in health status between COPD patients who used a belt-worn Mtx-W sensor and those who did not [42].
As this is a scoping review, we did not perform a systematic quality assessment of studies in this review, however, it is clear that the overall quality of evidence in included studies was low as there were few RCTs. Our findings on minimally published RCTs on this topic do however align with a 2018 meta-analysis reporting a lack of high-quality data on effectiveness for RHM and wearables [95]. In part, the paucity of high-quality data in this area can possibly be explained factors such as high cost associated with complex study protocols, significant implementation challenges, the need for industry partnerships, and complex ethical and legal barriers. There may also be a lack of buy-in from key stakeholders, including patients and doctors [96–98]. Given the paucity of evidence, the use of wearables and real-time data feedback for medical interventions, particularly in acute care, represents an emerging and largely uncharted frontier.
As mentioned, a large proportion of the reviewed publications used common, consumer-grade, wrist-worn devices, for example, fitness trackers or smartwatches. Despite concerns about their accuracy, commercial-grade devices have gained widespread popularity in the general population and therefore offer great potential for wide-spread health impacts. Save for a few select applications (ex. atrial fibrillation detection), these tools are marketed for non-medical use and lifestyle enhancement; however, the integration of their data in medical decision-making seems inevitable. Future research should attempt to test the medical utility of commercial-grade devices in the real-world.
Finally, a key factor in the successful implementation of RHM is patient interest and satisfaction [98]. Involving end users is essential to support patient-centered design principles that promote long-term adoption and usability [99,100]. However, most studies (41/80, 51%) did not report whether participants received device usage instructions. Proper education is critical, as improper use and motion artifacts can compromise data quality and analysis [101]. Additionally, only 13 studies (16%) described providing technical support for device setup or maintenance. This lack of support may contribute to the low compliance rates frequently observed in RHM studies [102,103]. Despite the importance of adherence, only 64% of studies in our review reported on participant compliance. Furthermore, just 16% included patient-reported data on device usability, and only 1% assessed baseline technology literacy. The absence of such data limits the ability to refine digital health interventions and adapt them to diverse populations. Future research should address not only the selection of wearable technologies, but also the critical role of patient education, ongoing technical support, and user engagement to enable successful and scalable implementation [104].
Another issue not well-addressed by the reviewed studies were concerns with data privacy and security. As artificial intelligence advances and risks related to data breaches and cyberattacks grow, the continuous transmission of data via wearables may raise significant privacy issues for patients. Future research must obtain appropriate ethical clearances and adhere to institutional and federal regulations, which may require the development of new policies governing continuous health monitoring technologies. In parallel, researchers and clinical innovators must prioritize the development of secure algorithms and communication channels to safeguard patient data. Compromised security could present a critical barrier to adoption and trust, particularly within research contexts. As wearable technologies become more prevalent in healthcare, careful consideration of regulatory frameworks and ethical requirements is essential to ensure patient safety and data protection.
Limitations
There are several limitations inherent to this review. Since the field of RHM continues to develop and expand, there is a general lack of consensus around terminology, for example, definitions of ‘remote monitoring’ and ‘wearable device’ [105]. This posed a significant challenge when devising a search strategy and we likely did not capture all relevant studies. However, our eligibility criteria were broad compared to prior work [3,106,107], allowing us to capture studies on a wide range of devices and disorders. We also performed citation searching to identify studies that were missed by our search strategy. Importantly, we did not eliminate studies based on methodological quality and we included both consumer-grade and medical-grade technologies. We focused on wearable (not implantable) devices and our findings may not generalize to more invasive forms of RHM, including blood glucose monitors and pacemakers. We also did not include smartphones in our definition of wearable devices, although these can in theory be ‘worn’ if strapped to the body. Lastly, the fast pace of innovation complicates the generalizability of data on older devices included in our review.
Conclusions
To our knowledge, our review is the most comprehensive to date for evidence of wearables influencing clinical outcomes in non-hospital settings. Our findings underscore the challenges of conducting timely and comprehensive evidence synthesis in this rapidly evolving field. The adoption of standardized terminology and consistent reporting on usability, acceptability, adherence, patient education, and technical support would enhance data quality and facilitate comparability across studies. High-quality RCT data is critically needed to establish the clinical utility of wearable technologies. Future research should be strategically prioritized to focus on technologies and applications most relevant to clinical practice and regulatory decision-making. Additionally, continued attention to patient privacy and data security will be essential to prevent unintended harms as these technologies are integrated into clinical care.
Supporting information
This search strategy was translated for use in other databases.
(DOCX)
(DOCX)
Data Availability
All data are in the manuscript and/or supporting information files.
Funding Statement
The author(s) received no specific funding for this work.
References
- 1.ltd R and M. Wearable Electronics - Global Strategic Business Report. [cited March 2, 2024] Available from: https://www.researchandmarkets.com/reports/4911767/wearable-electronics-global-strategic-business [Google Scholar]
- 2.Al-khafajiy M, Baker T, Chalmers C, Asim M, Kolivand H, Fahim M, et al. Remote health monitoring of elderly through wearable sensors. Multimed Tools Appl. 2019;78(17):24681–706. doi: 10.1007/s11042-018-7134-7 [DOI] [Google Scholar]
- 3.King CE, Sarrafzadeh M. A survey of smartwatches in remote health monitoring. J Healthc Inform Res. 2018;2(1–2):1–24. doi: 10.1007/s41666-017-0012-7 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Beiwinkel T, Kindermann S, Maier A, Kerl C, Moock J, Barbian G, et al. Using smartphones to monitor bipolar disorder symptoms: a pilot study. JMIR Ment Health. 2016;3(1):e2. doi: 10.2196/mental.4560 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Gao W, Emaminejad S, Nyein HYY, Challa S, Chen K, Peck A, et al. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis. Nature. 2016;529(7587):509–14. doi: 10.1038/nature16521 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Gheorghiu B, Ratchford F. Scaling up the use of remote patient monitoring in Canada. Stud Health Technol Inform. 2015. [PubMed] [Google Scholar]
- 7.Patel H, Hassell A, Keniston A, Davis C. Impact of remote patient monitoring on length of stay for patients with COVID-19. Telemed e-Health. 2023;29. [DOI] [PubMed] [Google Scholar]
- 8.Patel V, Orchanian-Cheff A, Wu R. Evaluating the validity and utility of wearable technology for continuously monitoring patients in a hospital setting: systematic review. JMIR Mhealth Uhealth. 2021. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Dimitrov D. Medical internet of things and big data in healthcare. Healthc Inform Res. 2016. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Baig M, GholamHosseini H, Moqeem A, Mirza F, Lindén M. A systematic review of wearable patient monitoring systems – current challenges and opportunities for clinical adoption. J Med Syst. 2017;41. [DOI] [PubMed] [Google Scholar]
- 11.Jafleh EA, Alnaqbi FA, Almaeeni HA, Faqeeh S, Alzaabi MA, Al Zaman K. The role of wearable devices in chronic disease monitoring and patient care: a comprehensive review. Cureus. 2024;16(9):e68921. doi: 10.7759/cureus.68921 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Stuart T, Hanna J, Gutruf P. Wearable devices for continuous monitoring of biosignals: challenges and opportunities. APL Bioeng. 2022. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Arksey H, O’Malley L. Scoping studies: towards a methodological framework. International Journal of Social Research Methodology. 2005;8(1):19–32. doi: 10.1080/1364557032000119616 [DOI] [Google Scholar]
- 14.Peters MDJ, Godfrey CM, Khalil H, McInerney P, Parker D, Soares CB. Guidance for conducting systematic scoping reviews. Int J Evid Based Healthc. 2015;13(3):141–6. doi: 10.1097/XEB.0000000000000050 [DOI] [PubMed] [Google Scholar]
- 15.Covidence systematic review software. Veritas Health Innovation. 2022. [Google Scholar]
- 16.Garcia R, Warming PE, Narayanan K, Defaye P, Guedon-Moreau L, Blangy H, et al. Dynamic changes in nocturnal heart rate predict short-term cardiovascular events in patients using the wearable cardioverter-defibrillator: from the WEARIT-France cohort study. Europace. 2023;25(5):euad062. doi: 10.1093/europace/euad062 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Kim DY, Kwon H, Nam K-W, Lee Y, Kwon H-M, Chung YS. Remote management of poststroke patients with a smartphone-based management system integrated in clinical care: prospective, nonrandomized, interventional study. J Med Internet Res. 2020;22(2):e15377. doi: 10.2196/15377 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Kolk M, Frodi D, Langford J, Meskers C, Andersen T, Jacobsen P, et al. Behavioural digital biomarkers enable real-time monitoring of patient-reported outcomes: a substudy of the multicenter, prospective observational SafeHeart study. Eur Heart J Qual Care Clin Outcomes. 2023. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Okumus G, Aslan GK, Arseven O, Ongen G, Issever H, Kiyan E. The role of an activity monitor in the objective evaluation of patients with pulmonary hypertension. Clin Respir J. 2018;12(1):119–25. doi: 10.1111/crj.12495 [DOI] [PubMed] [Google Scholar]
- 20.Pothineni NVK, Soliman EZ, Cushman M, Howard G, Howard VJ, Kasner SE, et al. Continuous cardiac rhythm monitoring post-stroke: a feasibility study in REGARDS. J Stroke Cerebrovasc Dis. 2022;31:106662. [DOI] [PubMed] [Google Scholar]
- 21.Rosenberg MA, Samuel M, Thosani A, Zimetbaum PJ. Use of a noninvasive continuous monitoring device in the management of atrial fibrillation: a pilot study. Pacing Clin Electrophysiol. 2013;36(3):328–33. doi: 10.1111/pace.12053 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Stehlik J, Schmalfuss C, Bozkurt B, Nativi-Nicolau J, Wohlfahrt P, Wegerich S, et al. Continuous wearable monitoring analytics predict heart failure hospitalization: The LINK-HF multicenter study. Circ Heart Fail. 2020;13(3):e006513. doi: 10.1161/CIRCHEARTFAILURE.119.006513 [DOI] [PubMed] [Google Scholar]
- 23.Stollfuss B, Richter M, Drömann D, Klose H, Schwaiblmair M, Gruenig E, et al. Digital tracking of physical activity, heart rate, and inhalation behavior in patients with pulmonary arterial hypertension treated with inhaled iloprost: observational study (VENTASTEP). J Med Internet Res. 2021;23(10):e25163. doi: 10.2196/25163 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Tung CE, Su D, Turakhia MP, Lansberg MG. Diagnostic yield of extended cardiac patch monitoring in patients with stroke or TIA. Front Neurol. 2014;5:266. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Abbott CA, Chatwin KE, Foden P, Hasan AN, Sange C, Rajbhandari SM, et al. Innovative intelligent insole system reduces diabetic foot ulcer recurrence at plantar sites: a prospective, randomised, proof-of-concept study. Lancet Digit Health. 2019;1(6):e308–18. doi: 10.1016/S2589-7500(19)30128-1 [DOI] [PubMed] [Google Scholar]
- 26.Armstrong DG, Lavery LA, Holtz-Neiderer K, Mohler MJ, Wendel CS, Nixon BP, et al. Variability in activity may precede diabetic foot ulceration. Diabetes Care. 2004;27(8):1980–4. doi: 10.2337/diacare.27.8.1980 [DOI] [PubMed] [Google Scholar]
- 27.Najafi B, Ron E, Enriquez A, Marin I, Razjouyan J, Armstrong DG. Smarter sole survival: will neuropathic patients at high risk for ulceration use a smart insole-based foot protection system?. J Diabetes Sci Technol. 2017;11(4):702–13. doi: 10.1177/1932296816689105 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Reyzelman AM, Koelewyn K, Murphy M, Shen X, Yu E, Pillai R, et al. Continuous temperature-monitoring socks for home use in patients with diabetes: observational study. J Med Internet Res. 2018;20(12):e12460. doi: 10.2196/12460 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Dadhania S, Pakzad-Shahabi L, Mistry S, Williams M. Triaxial accelerometer-measured physical activity and functional behaviours among people with high grade glioma: the brainwear study. PLoS One. 2023;18(5):e0285399. doi: 10.1371/journal.pone.0285399 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Gresham G, Hendifar AE, Spiegel B, Neeman E, Tuli R, Rimel BJ, et al. Wearable activity monitors to assess performance status and predict clinical outcomes in advanced cancer patients. NPJ Digit Med. 2018;1:27. doi: 10.1038/s41746-018-0032-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Korde N, Tavitian E, Mastey D, Lengfellner J, Hevroni G, Zarski A, et al. Association of patient activity bio-profiles with health-related quality of life in patients with newly diagnosed multiple myeloma: a prospective observational cohort study. EClinicalMedicine. 2023;57:101854. doi: 10.1016/j.eclinm.2023.101854 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Low CA, Li M, Vega J, Durica KC, Ferreira D, Tam V, et al. Digital biomarkers of symptom burden self-reported by perioperative patients undergoing pancreatic surgery: prospective longitudinal study. JMIR Cancer. 2021;7(2):e27975. doi: 10.2196/27975 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Low CA, Bartel C, Fedor J, Durica KC, Marchetti G, Rosso AL, et al. Associations between performance-based and patient-reported physical functioning and real-world mobile sensor metrics in older cancer survivors: a pilot study. J Geriatr Oncol. 2024;15(2):101708. doi: 10.1016/j.jgo.2024.101708 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Ohri N, Halmos B, Bodner WR, Cheng H, Guha C, Kalnicki S, et al. Daily step counts: a new prognostic factor in locally advanced non-small cell lung cancer?. Int J Radiat Oncol Biol Phys. 2019;105(4):745–51. doi: 10.1016/j.ijrobp.2019.07.055 [DOI] [PubMed] [Google Scholar]
- 35.Cohen B, Munugoti S, Kotwani S, Randhawa LS, Dalezman S, Elters AC, et al. Continuous long-term physical activity monitoring in hemodialysis patients. Kidney360. 2022;3(9):1545–55. doi: 10.34067/KID.0002082022 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Lunney M, Wiebe N, Kusi-Appiah E, Tonelli A, Lewis R, Ferber R, et al. Wearable fitness trackers to predict clinical deterioration in maintenance hemodialysis: a prospective cohort feasibility study. Kidney Med. 2021;3(5):768-775.e1. doi: 10.1016/j.xkme.2021.04.013 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Drent M, Elfferich M, Breedveld E, Vries JD, Strookappe B. Benefit of wearing an activity tracker in sarcoidosis. J Pers Med. 2020;10(3):97. doi: 10.3390/jpm10030097 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Hawthorne G, Richardson M, Greening N, Esliger D, Briggs-Price S, Chaplin E. A proof of concept for continuous, non-invasive, free-living vital signs monitoring to predict readmission following an acute exacerbation of copd: a prospective cohort study. Respir Res. 2022;23:102. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Orme MW, Weedon AE, Saukko PM, Esliger DW, Morgan MD, Steiner MC, et al. Findings of the Chronic Obstructive Pulmonary Disease-Sitting and Exacerbations Trial (COPD-SEAT) in reducing sedentary time using wearable and mobile technologies with educational support: randomized controlled feasibility trial. JMIR Mhealth Uhealth. 2018;6(4):e84. doi: 10.2196/mhealth.9398 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Pedone C, Chiurco D, Scarlata S, Incalzi RA. Efficacy of multiparametric telemonitoring on respiratory outcomes in elderly people with COPD: a randomized controlled trial. BMC Health Serv Res. 2013;13:82. doi: 10.1186/1472-6963-13-82 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Rubio N, Parker RA, Drost EM, Pinnock H, Weir CJ, Hanley J, et al. Home monitoring of breathing rate in people with chronic obstructive pulmonary disease: observational study of feasibility, acceptability, and change after exacerbation. Int J Chron Obstruct Pulmon Dis. 2017;12:1221–31. doi: 10.2147/COPD.S120706 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Tabak M, Vollenbroek-Hutten M, van der Valk P, van der Palen J, Hermens H. A telerehabilitation intervention for patients with chronic obstructive pulmonary disease: a randomized controlled pilot trial. Clin Rehabil. 2014;28:582–91. [DOI] [PubMed] [Google Scholar]
- 43.Wu C-T, Li G-H, Huang C-T, Cheng Y-C, Chen C-H, Chien J-Y, et al. Acute exacerbation of a chronic obstructive pulmonary disease prediction system using wearable device data, machine learning, and deep learning: development and cohort study. JMIR Mhealth Uhealth. 2021;9(5):e22591. doi: 10.2196/22591 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Wurzer D, Spielhagen P, Siegmann A, Gercekcioglu A, Gorgass J, Henze S, et al. Remote monitoring of COVID-19 positive high-risk patients in domestic isolation: a feasibility study. PLoS One. 2021;16(9):e0257095. doi: 10.1371/journal.pone.0257095 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Yamagami K, Nomura A, Kometani M, Shimojima M, Sakata K, Usui S, et al. Early detection of symptom exacerbation in patients with SARS-CoV-2 infection using the fitbit charge 3 (DEXTERITY): pilot evaluation. JMIR Form Res. 2021;5(9):e30819. doi: 10.2196/30819 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Gurchiek RD, Choquette RH, Beynnon BD, Slauterbeck JR, Tourville TW, Toth MJ. Open-source remote gait analysis: a post-surgery patient monitoring application. Sci Rep. 2019;9:17966. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.Maharaj M, Natarajan P, Fonseka RD, Khanna S, Choy WJ, Rooke K, et al. The concept of recovery kinetics: an observational study of continuous post-operative monitoring in spine surgery. J Spine Surg. 2022;8(2):196–203. doi: 10.21037/jss-22-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Patterson JT, Wu H-H, Chung CC, Bendich I, Barry JJ, Bini SA. Wearable activity sensors and early pain after total joint arthroplasty. Arthroplast Today. 2020;6(1):68–70. doi: 10.1016/j.artd.2019.12.006 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Perraudin CGM, Illiano VP, Calvo F, O’Hare E, Donnelly SC, Mullan RH, et al. Observational study of a wearable sensor and smartphone application supporting unsupervised exercises to assess pain and stiffness. Digit Biomark. 2018;2(3):106–25. doi: 10.1159/000493277 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50.Scheer JK, Bakhsheshian J, Keefe MK, Lafage V, Bess S, Protopsaltis TS, et al. Initial experience with real-time continuous physical activity monitoring in patients undergoing spine surgery. Clin Spine Surg. 2017;30(10):E1434–43. doi: 10.1097/BSD.0000000000000521 [DOI] [PubMed] [Google Scholar]
- 51.Toogood PA, Abdel MP, Spear JA, Cook SM, Cook DJ, Taunton MJ. The monitoring of activity at home after total hip arthroplasty. Bone Joint J. 2016;98-B(11):1450–4. doi: 10.1302/0301-620X.98B11.BJJ-2016-0194.R1 [DOI] [PubMed] [Google Scholar]
- 52.Block V. Fitbit remote-monitoring in multiple sclerosis: FITriMS study. Fitbit Remote-Monitoring in Multiple Sclerosis: FITriMS Study. 2016. [Google Scholar]
- 53.Block VJ, Lizée A, Crabtree-Hartman E, Bevan CJ, Graves JS, Bove R, et al. Continuous daily assessment of multiple sclerosis disability using remote step count monitoring. J Neurol. 2017;264(2):316–26. doi: 10.1007/s00415-016-8334-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54.Block VJ, Bove R, Zhao C, Garcha P, Graves J, Romeo AR, et al. Association of Continuous Assessment of Step Count by Remote Monitoring With Disability Progression Among Adults With Multiple Sclerosis. JAMA Netw Open. 2019;2(3):e190570. doi: 10.1001/jamanetworkopen.2019.0570 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Block VJ, Gopal A, Rowles W, -Yueh C, Gelfand JM, Bove R. CoachMS, an innovative closed-loop, interdisciplinary platform to monitor and proactively treat MS symptoms: A pilot study. Mult Scler J Exp Transl Clin. 2021;7(1):2055217321988937. doi: 10.1177/2055217321988937 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56.Burq M, Rainaldi E, Ho KC, Chen C, Bloem BR, Evers LJW, et al. Virtual Exam for Parkinson’s Disease Enables Frequent and Reliable Remote Measurements of Motor Function. medRxiv [Internet]. 2021; Available from: https://www.medrxiv.org// [DOI] [PMC free article] [PubMed] [Google Scholar]
- 57.Caballol N, Bayés À, Prats A, Martín-Baranera M, Quispe P. Feasibility of a wearable inertial sensor to assess motor complications and treatment in Parkinson’s disease. PLoS One. 2023;18(2):e0279910. doi: 10.1371/journal.pone.0279910 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58.Cereda E, Pezzoli G, Barichella M. Role of an electronic armband in motor function monitoring in patients with Parkinson’s disease. Nutrition. 2010;26(2):240–2. doi: 10.1016/j.nut.2009.06.003 [DOI] [PubMed] [Google Scholar]
- 59.Dalla Costa G, Nos C, Zabalza A, Buron M, Magyari M, Sellebjerg F, et al. A wearable device perspective on the standard definitions of disability progression in multiple sclerosis. Mult Scler. 2024;30(1):103–12. doi: 10.1177/13524585231214362 [DOI] [PubMed] [Google Scholar]
- 60.Davies EH, Johnston J, Toro C, Tifft CJ. A feasibility study of mHealth and wearable technology in late onset GM2 gangliosidosis (Tay-Sachs and Sandhoff Disease). Orphanet J Rare Dis. 2020;15(1):199. doi: 10.1186/s13023-020-01473-x [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61.Fay-Karmon T, Galor N, Heimler B, Zilka A, Bartsch RP, Plotnik M. Home-based monitoring of persons with advanced Parkinson’s disease using smartwatch-smartphone technology. Sci Rep. 2024;14. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 62.Gordon M, Grachev I, Mazeh I, Dolan Y, Reilmann R, Loupe P. Quantification of motor function in Huntington disease patients using wearable sensor devices. Digit Biomark. 2019;3:103–15. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 63.Joshi R, Joshi M, Bronstein J, Keener A, Yang D, Alcazar J. Pkg movement recording system use shows promise in routine clinical care of patients with Parkinson’s disease. Front Neurol. 2019;10. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 64.Klassen L, Schachter C, Scudds R. An exploratory study of two measures of free-living physical activity for people with multiple sclerosis. Clin Rehabil. 2008;22(3):260–71. doi: 10.1177/0269215507082740 [DOI] [PubMed] [Google Scholar]
- 65.Kotschet K, Osborn S, Horne M. Measurement of bradykinesia and chorea in Huntington’s Disease using ambulatory monitoring. Clin Park Relat Disord. 2022;8:100179. doi: 10.1016/j.prdoa.2022.100179 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 66.Kratz AL, Fritz NE, Braley TJ, Scott EL, Foxen-Craft E, Murphy SL. Daily temporal associations between physical activity and symptoms in multiple sclerosis. Ann Behav Med. 2019;53(1):98–108. doi: 10.1093/abm/kay018 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 67.Mancini M, El-Gohary M, Pearson S, McNames J, Schlueter H, Nutt JG, et al. Continuous monitoring of turning in Parkinson’s disease: Rehabilitation potential. NeuroRehabilitation. 2015;37(1):3–10. doi: 10.3233/NRE-151236 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 68.Motl RW, McAuley E. Association between change in physical activity and short-term disability progression in multiple sclerosis. J Rehabil Med. 2011;43(4):305–10. doi: 10.2340/16501977-0782 [DOI] [PubMed] [Google Scholar]
- 69.Powers R, Etezadi-Amoli M, Arnold E, Kianian S, Mance I, Gibiansky M, et al. Smartwatch inertial sensors continuously monitor real-world motor fluctuations in Parkinson’s disease. Sci Transl Med. 2021;13. [DOI] [PubMed] [Google Scholar]
- 70.Shammas L, Zentek T, von Haaren B, Schlesinger S, Hey S, Rashid A. Home-based system for physical activity monitoring in patients with multiple sclerosis (Pilot study). Biomed Eng Online. 2014;13:10. doi: 10.1186/1475-925X-13-10 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 71.van Vugt JP, Siesling S, Piet KK, Zwinderman AH, Middelkoop HA, van Hilten JJ, et al. Quantitative assessment of daytime motor activity provides a responsive measure of functional decline in patients with Huntington’s disease. Mov Disord. 2001;16(3):481–8. doi: 10.1002/mds.1097 [DOI] [PubMed] [Google Scholar]
- 72.Weiss A, Herman T, Giladi N, Hausdorff JM. Objective assessment of fall risk in parkinson’s disease using a body-fixed sensor worn for 3 days. 2014; Available from: https://login.ezproxy.library.ualberta.ca/login?url= https://search.ebscohost.com/login.aspx?direct=true&db=edshld&AN=edshld.1.12407046&site=eds-live&scope=site [DOI] [PMC free article] [PubMed] [Google Scholar]
- 73.Woelfle T, Pless S, Reyes Ó, Wiencierz A, Kappos L, Granziera C, et al. Smartwatch-derived sleep and heart rate measures complement step counts in explaining established metrics of MS severity. Mult Scler Relat Disord. 2023;80:105104. doi: 10.1016/j.msard.2023.105104 [DOI] [PubMed] [Google Scholar]
- 74.Alinia P, Sah RK, McDonell M, Pendry P, Parent S, Ghasemzadeh H, et al. Associations between physiological signals captured using wearable sensors and self-reported outcomes among adults in alcohol use disorder recovery: development and usability study. JMIR Form Res. 2021;5(7):e27891. doi: 10.2196/27891 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 75.Carreiro S, Chintha KK, Shrestha S, Chapman B, Smelson D, Indic P. Wearable sensor-based detection of stress and craving in patients during treatment for substance use disorder: A mixed methods pilot study. Drug Alcohol Depend. 2020;209:107929. doi: 10.1016/j.drugalcdep.2020.107929 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 76.Knight A, Bidargaddi N. Commonly available activity tracker apps and wearables as a mental health outcome indicator: A prospective observational cohort study among young adults with psychological distress. J Affect Disord. 2018;236:31–6. doi: 10.1016/j.jad.2018.04.099 [DOI] [PubMed] [Google Scholar]
- 77.Lahti AC, Wang D, Pei H, Baker S, Narayan VA. Clinical utility of wearable sensors and patient-reported surveys in patients with schizophrenia: noninterventional, observational study. JMIR Ment Health. 2021;8(8):e26234. doi: 10.2196/26234 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 78.Lee H, Cho C, Lee T, Jeong J, Yeom J, Kim S. Prediction of impending mood episode recurrence using real-time digital phenotypes in major depression and bipolar disorders in South Korea: a prospective nationwide cohort study. Psychol Med. 2022:1–9. [DOI] [PubMed] [Google Scholar]
- 79.Mahoney JJ, Finomore VS, Marton JL, Ramadan J, Hodder SL, Thompson-Lake DGY, et al. Identifying biomarkers of drug use recurrence using wearable device technologies and phone applications. Drug Alcohol Depend. 2023;249:110817. doi: 10.1016/j.drugalcdep.2023.110817 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 80.O’Brien JT, Gallagher P, Stow D, Hammerla N, Ploetz T, Firbank M, et al. A study of wrist-worn activity measurement as a potential real-world biomarker for late-life depression. Psychol Med. 2017;47(1):93–102. doi: 10.1017/S0033291716002166 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 81.Sun S, Folarin AA, Zhang Y, Cummins N, Garcia-Dias R, Stewart C, et al. Challenges in Using mHealth Data From Smartphones and Wearable Devices to Predict Depression Symptom Severity: Retrospective Analysis. J Med Internet Res. 2023;25. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 82.Zhang Y, Folarin AA, Sun S, Cummins N, Bendayan R, Ranjan Y, et al. Relationship between major depression symptom severity and sleep collected using a wristband wearable device: multicenter longitudinal observational study. JMIR Mhealth Uhealth. 2021;9(4):e24604. doi: 10.2196/24604 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 83.Ha ACT, Verma S, Mazer CD, Quan A, Yanagawa B, Latter DA, et al. Effect of continuous electrocardiogram monitoring on detection of undiagnosed atrial fibrillation after hospitalization for cardiac surgery: a randomized clinical trial. JAMA Netw Open. 2021;4(8):e2121867. doi: 10.1001/jamanetworkopen.2021.21867 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 84.Moshe I, Terhorst Y, Opoku Asare K, Sander LB, Ferreira D, Baumeister H, et al. Predicting symptoms of depression and anxiety using smartphone and wearable data. Front Psychiatry. 2021;12:625247. doi: 10.3389/fpsyt.2021.625247 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 85.Pagola J, Juega J, Francisco-Pascual J, Rodriguez M, Dorado L, Martinez R, et al. Intensive 90-day textile wearable Holter monitoring: an alternative to detect paroxysmal atrial fibrillation in selected patients with cryptogenic stroke. Heart Vessels. 2023;38(1):114–21. doi: 10.1007/s00380-022-02141-9 [DOI] [PubMed] [Google Scholar]
- 86.Perez MV, Mahaffey KW, Hedlin H, Rumsfeld JS, Garcia A, Ferris T, et al. Large-scale assessment of a smartwatch to identify atrial fibrillation. N Engl J Med. 2019;381(20):1909–17. doi: 10.1056/NEJMoa1901183 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 87.Rooney MR, Soliman EZ, Lutsey PL, Norby FL, Loehr LR, Mosley TH, et al. Prevalence and characteristics of subclinical atrial fibrillation in a community-dwelling elderly population: the ARIC study. Circ Arrhythm Electrophysiol. 2019;12(10):e007390. doi: 10.1161/CIRCEP.119.007390 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 88.Schreiber D, Sattar A, Drigalla D, Higgins S. Ambulatory cardiac monitoring for discharged emergency department patients with possible cardiac arrhythmias. West J Emerg Med. 2014;15:194–8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 89.Steinhubl SR, Waalen J, Edwards AM, Ariniello LM, Mehta RR, Ebner GS, et al. Effect of a home-based wearable continuous ECG monitoring patch on detection of undiagnosed atrial fibrillation: the mSToPS randomized clinical trial. JAMA. 2018;320(2):146–55. doi: 10.1001/jama.2018.8102 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 90.Tison GH, Sanchez JM, Ballinger B, Singh A, Olgin JE, Pletcher MJ, et al. Passive detection of atrial fibrillation using a commercially available smartwatch. JAMA Cardiol. 2018;3(5):409–16. doi: 10.1001/jamacardio.2018.0136 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 91.Wouters F, Gruwez H, Vranken J, Vanhaen D, Daelman B, Ernon L, et al. The potential and limitations of mobile health and insertable cardiac monitors in the detection of atrial fibrillation in cryptogenic stroke patients: preliminary results from the REMOTE trial. Front Cardiovasc Med. 2022;9:848914. doi: 10.3389/fcvm.2022.848914 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 92.Mishra T, Wang M, Metwally AA, Bogu GK, Brooks AW, Bahmani A, et al. Pre-symptomatic detection of COVID-19 from smartwatch data. Nat Biomed Eng. 2020;4(12):1208–20. doi: 10.1038/s41551-020-00640-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 93.Smarr BL, Aschbacher K, Fisher SM, Chowdhary A, Dilchert S, Puldon K, et al. Feasibility of continuous fever monitoring using wearable devices. Sci Rep. 2020;10(1):21640. doi: 10.1038/s41598-020-78355-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 94.Radin JM, Wineinger NE, Topol EJ, Steinhubl SR. Harnessing wearable device data to improve state-level real-time surveillance of influenza-like illness in the USA: a population-based study. Lancet Digit Health. 2020;2(2):e85–93. doi: 10.1016/S2589-7500(19)30222-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 95.Noah B, Keller MS, Mosadeghi S, Stein L, Johl S, Delshad S, et al. Impact of remote patient monitoring on clinical outcomes: an updated meta-analysis of randomized controlled trials. NPJ Digit Med. 2018;1:20172. doi: 10.1038/s41746-017-0002-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 96.Izmailova ES, Wagner JA, Perakslis ED. Wearable devices in clinical trials: hype and hypothesis. Clin Pharmacol Ther. 2018;104. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 97.Smuck M, Odonkor C, Wilt J, Schmidt N, Swiernik M. The emerging clinical role of wearables: factors for successful implementation in healthcare. NPJ Digit Med. 2021. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 98.Dzimitrowicz HE, Blakely LJ, Jones LW, LeBlanc TW. Bridging New Technology Into Clinical Practice With Mobile Apps, Electronic Patient-Reported Outcomes, and Wearables. American Society of Clinical Oncology Educational Book. 2022. [DOI] [PubMed] [Google Scholar]
- 99.Botti A, Monda A. Sustainable value co-creation and digital health: the case of trentino eHealth ecosystem. Sustainability. 2020;12(13):5263. doi: 10.3390/su12135263 [DOI] [Google Scholar]
- 100.Enam A, Dreyer HC, De Boer L. Impact of distance monitoring service in managing healthcare demand: a case study through the lens of cocreation. BMC Health Serv Res. 2022;22(1):802. doi: 10.1186/s12913-022-08164-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 101.Majumder S, Mondal T, Deen MJ. Wearable sensors for remote health monitoring. Sensors (Basel). 2017;17(1):130. doi: 10.3390/s17010130 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 102.Pratap A, Neto EC, Snyder P, Stepnowsky C, Elhadad N, Grant D, et al. Indicators of retention in remote digital health studies: a cross-study evaluation of 100,000 participants. NPJ Digit Med. 2020;3:21. doi: 10.1038/s41746-020-0224-8 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 103.Doumen M, De Cock D, Van Lierde C, Betrains A, Pazmino S, Bertrand D. Engagement and attrition with eHealth tools for remote monitoring in chronic arthritis: a systematic review and meta-analysis. RMD Open. 2022. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 104.Warrington L, Absolom K, Conner M, Kellar I, Clayton B, Ayres M. Electronic systems for patients to report and manage side effects of cancer treatment: systematic review. J Med Internet Res. 2019. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 105.Alvarado MM, Kum HC, Coronado KG, Foster MJ, Ortega P, Lawley MA. Barriers to remote health interventions for type 2 diabetes: a systematic review and proposed classification scheme. J Med Internet Res. 2017. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 106.Olmedo-Aguirre J, Reyes-Campos J, Alor-Hernández G, Machorro-Cano I, Rodríguez-Mazahua L, Sánchez-Cervantes J. Remote healthcare for elderly people using wearables: a review. Biosensors. 2022. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 107.Hilty DM, Armstrong CM, Luxton DD, Gentry MT, Krupinski EA. A scoping review of sensors, wearables, and remote monitoring for behavioral health: uses, outcomes, clinical competencies, and research directions. J Technol Behav Sci. 2021. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
This search strategy was translated for use in other databases.
(DOCX)
(DOCX)
Data Availability Statement
All data are in the manuscript and/or supporting information files.