CCD design matrix of coded process variables and corresponding results.

S.N Run X1 X2 X3 Y, CO2 Uptake (mmol/g)
Experimental Response Error (%)
1 19 − 1 − 1 − 1 2.3090 2.3559 1.99
2 3 1 − 1 − 1 4.0319 4.0221 0.24
3 11 − 1 1 − 1 2.5805 2.6018 0.82
4 9 1 1 − 1 3.9771 4.1294 3.69
5 18 − 1 − 1 1 2.3635 2.2566 4.52
6 8 1 − 1 1 3.3318 3.3559 0.72
7 13 − 1 1 1 2.2221 2.2773 2.43
8 6 1 1 1 3.2394 3.2380 0.05
9 14 − 1 0 0 2.7215 2.7050 0.61
10 20 1 0 0 4.1834 4.0184 3.94
11 15 0 − 1 0 3.8690 3.9149 1.17
12 16 0 1 0 4.2063 3.9789 5.40
13 17 0 0 − 1 3.8715 3.6608 5.44
14 4 0 0 1 3.1362 3.1654 0.92
15 1 0 0 0 3.8747 3.8461 0.74
16 10 0 0 0 3.7626 3.8461 2.17
17 5 0 0 0 3.7343 3.8461 2.91
18 2 0 0 0 3.8443 3.8461 0.04
19 7 0 0 0 3.6717 3.8461 4.53
20 12 0 0 0 3.8257 3.8461 0.53