Vertebral artery dissection with cerebellar stroke after use of a percussive massage device: illustrative case

Prasanth Romiyo 1,✉, Taylor Furst 1, Derek D George 1, Nathaniel Ellens 1, Matthew T Bender 1, Mark R Harrigan 2
PMCID: PMC12105589  PMID: 40418893

Abstract

BACKGROUND

Vertebral artery dissection is a rare condition often due to blunt cerebrovascular injury (BCVI). Electric massage devices have rarely been documented as an etiology of BCVI; however, their use has become widespread. The authors present an illustrative case and literature review of right vertebral artery BCVI and cerebellar infarct following the use of an antique electric massage device.

OBSERVATIONS

A 65-year-old male presented with acute onset vertigo and nausea after using an antique electric massage device on his neck to relieve muscle tension. BCVI in the right vertebral artery was identified via CT angiography (CTA). MRI of the brain confirmed associated cerebellar infarction. Follow-up catheter cerebral angiography confirmed a right V3 segment intraluminal thrombus and V4 segment dissection. After inpatient observation, the patient was discharged on oral anticoagulation. At the 1-month follow-up, he reported no new symptoms, and CTA revealed resolution of the V3 thrombus and healing V4 dissection.

LESSONS

The authors report the first case of MRI-proven stroke in association with vertebral artery BCVI after the use of an antique electric massage device. This case highlights the need for kinetic studies to assess the force distribution of percussive instruments in an effort to prevent injuries.

https://thejns.org/doi/10.3171/CASE24812

Keywords: dissection, blunt cerebrovascular injury, stroke, percussive device, vertebral artery

ABBREVIATIONS: ADC = apparent diffusion coefficient, BCVI = blunt cerebrovascular injury, CTA = CT angiography, MRA = MR angiography, VAD = vertebral artery dissection.


Vertebral artery dissection (VAD) is a rare condition that can have a variety of etiologies, including blunt cerebrovascular injury (BCVI) in the context of trauma, spontaneous dissections due to arterial abnormalities, and iatrogenic causes such as in the context of surgical procedures including anterior cervical discectomy and fusion, posterior cervical fusions, and endovascular procedures.1–4 The use of electric massage devices has been rarely documented as an etiology of BCVI to the vertebral artery. However, readily available over the counter, their use has become widespread by therapists and in the fitness industries for treating myofascial conditions and pain despite being underresearched.5–7

Here, we present the case of a 65-year-old male who developed sudden-onset vertigo after using an antique body massager on his neck, resulting in BCVI to the right vertebral artery with subsequent right-sided acute cerebellar infarction. We also present a review of the scant literature on the topic.

Illustrative Case

A 65-year-old male with a past medical history of hyperlipidemia presented to the emergency department after experiencing sudden-onset vertigo. Following routine submaximal cardiovascular exercise on a stationary bike, he attempted to relieve generalized muscle tension in his neck using a 1950s’ iteration of a handheld percussive massage device patented by WAHL Manufacturing Co. in 1934 with a percussion range of 3600–7200 oscillations/min, which far exceeds the maximum of 3200 oscillations/min provided by modern devices.8 (Fig. 1). Shortly after using the device, the man became vertiginous and nauseated and described tingling in the fingertips of both extremities. These symptoms worsened with head movement.

FIG. 1.

FIG. 1.

Handheld percussion massage device circa 1950 (WAHL Manufacturing Co.).

Urgent noncontrast CT of the head was unremarkable and showed no acute infarct or hemorrhage. CT angiography (CTA) demonstrated a right VAD with intraluminal thrombus (Fig. 2). MRI showed punctate areas of diffusion restriction in the right cerebellar hemisphere with an apparent diffusion coefficient (ADC) correlate consistent with acute thromboembolic infarction. Contrast-enhanced MR angiography (MRA) with advanced vessel wall imaging demonstrated a “target sign” within the V3–4 segment of the right vertebral artery. Vessel wall enhancement in the V4 segment was consistent with underlying dissection (Fig. 3). Catheter cerebral angiography confirmed a right V4 segment dissection extending to the origin of the basilar artery consistent with a grade II BCVI (Fig. 4). Additionally, a nonocclusive thrombus was noted within the distal V3 segment. The infarcts and dissection were thought to be traumatic in nature secondary to the patient’s recent use of a percussive massage device.

FIG. 2.

FIG. 2.

CT angiograms showing right VAD. Axial (A and B) and rotational maximal intensity projection (C) CT angiograms of the right vertebral artery showing focal filling defects in the V3–4 junction to the vertebrobasilar junction (red arrows) along with decreased luminal caliber of the intracranial vertebral artery, suggestive of dissection with intraluminal thrombus.

FIG. 3.

FIG. 3.

MR images of the brain. Axial diffusion-weighted (A) and ADC (B) MR sequences revealing acute infarct in the posterior inferior right cerebellar hemisphere (arrows left). Axial contrast-enhanced fast spin-echo MR angiogram (C) showing vessel wall enhancement and luminal irregularities in the intracranial right vertebral artery, suggesting acute dissection (arrow right).

FIG. 4.

FIG. 4.

Digital subtraction angiograms of the vertebrobasilar system. Anterior-posterior (A) and lateral (B) projections of a right vertebral artery injection catheter angiogram depicting the dissection of the V4 segment extending to the vertebrobasilar junction associated with luminal irregularities and thrombus (arrows).

The patient’s hospital course was uneventful, and he was discharged home on apixaban 5 mg twice daily and atorvastatin 40 mg daily for secondary stroke prevention. He described continued dizziness and headache in subsequent telephone encounters after discharge. A follow-up CT angiogram obtained 1 month after presentation showed resolution of the intraluminal thrombus with decreased conspicuity of the V4 dissection (Fig. 5).

FIG. 5.

FIG. 5.

Sagittal (A) and coronal (B) CT angiograms of the right vertebral artery acquired 1 month after initial presentation showing resolution of intraluminal thrombus with decreased conspicuity of V4 luminal irregularities (arrows).

Informed Consent

The necessary informed consent was obtained in this study.

Discussion

Observations

Here, we demonstrate a case of an acute V4 dissection with extension into the proximal basilar artery with a distal V3 intraluminal thrombus and cerebellar infarct associated with the use of a percussive massage device.

A total of 3 case reports of VAD from percussion massage devices have been published, only one of which was associated with a handheld device. In the case of Sulkowski et al.,9 a 27-year-old woman presented with a 2-week history of dizziness and disequilibrium without a history of trauma or stimulant use, but had been regularly using a modern percussive massage gun. CT of the head showed no abnormality, but CTA revealed a right vertebral artery cervical segment with stenotic luminal irregularities consistent with dissection. The other cases of VAD occurred in patients using massage chairs/pillows.10

Our case represents what we believe to be only the second instance of VAD related to the use of a handheld percussion massage device in the current literature and provides the most comprehensive imaging assessment to date for this specific presentation. It remains possible that the current case resulted from either a spontaneous or an exercise-induced VAD, which are both well-known etiologies of this pathology. Supporting these other theories is the fact that the patient complained of muscle tension in the neck following exercise. However, the exercise reported was a submaximal routine cardiovascular exercise on a stationary bike, not vigorous in nature. Furthermore, the reported generalized muscle tension is thought to be the result of neck positioning while on the stationary bike, rather than spontaneous-onset unilateral neck pain associated with a VAD. Because of the routine submaximal exercise efforts, generalized muscle tension, and temporal relation of symptom onset with the use of the handheld percussion massage device, it is the authors’ opinion that spontaneous and exercise-induced VADs are less likely etiologies.

No studies have directly addressed the mechanistic potential of handheld percussion massage devices to cause bodily injury. However, cases of VAD, rhabdomyolysis, hemothorax, and ophthalmological injury demonstrate that these devices can inflict serious harm.9,11–13 Modern handheld percussive massage devices (or “guns”) have multiple characteristics that can influence the force vector quantity applied to tissues. These operating parameters include stall force, stroke length, and percussion range. Stall force is defined as the force required to stall the actuator by applying perpendicular force to the tissue. Stroke length is the amplitude of the axial motion of the applicator. The percussion range is the frequency of applicator oscillations per minute. Commercially available modern handheld percussion massage devices have stall forces ranging from approximately 16 to 36 kg (35–80 lb), stroke lengths ranging from 5 to 16 mm, and percussion ranges of up to 3200 oscillations/min. The relationship of device operating parameters to tissue compression loading has not been well characterized; however, cadaveric studies have shown that the tensile force required to cause dissection or rupture of the vertebral artery ranges from 1.4 to 9.7 N (0.31–2.18 pound-force).14 Whether the force generated from these devices can exceed the tensile force necessary to cause VAD is unknown, although our case suggests it is possible. Moreover, the dearth of reported BCVI cases caused by these devices suggests other factors, such as overlying tissue density, could be important contributors to possible injury. Further studies are necessary to understand the biomechanical forces of these devices and their propensity for tissue injury.

Interestingly, the percussive massage device used by our patient was an antique. US patent filings provide some insight into the functionality of the device. In the filing of the original device in 1934, Wahl8 wrote that his “vibrator device” could produce 60–120 vibrations/sec (3600–7200 vibrations/min), with the lower hertz setting able to “move the armature and its implement outwardly to deliver its blow with perfect freedom and at such a rate as to produce a much better penetration.” Our patient’s device was a later iteration from circa 1950. While operative parameters of stall force and stroke length are unknown for this device, the percussion range of 3600–7200 vibrations/min is higher than that of currently available devices. Thus, this device could be capable of imparting powerful pulsations of high enough frequencies to potentiate tissue damage, and antique devices such as these might have a higher potential to cause BCVI.

Little research exists describing how much force is translated through muscle and bone to the underlying vasculature with handheld percussive devices. Biomechanical studies exploring the force needed to cause fractures of the cervical spine in military combat environments show that peak forces of up to 4382 Newtons (985.11 pounds-force) are required to result in instability with vertical loading.15 More analogous to manual percussive devices are axial and shearing forces applied during whiplash injuries, with up to 1518 N (341.2 pound-force) required to trigger fractures of the cervical spine.16 While these machines are capable of delivering direct blunt force much greater than that required to disrupt luminal architecture, the relative dearth of BCVI cases caused by percussive devices suggests that the cervical spine and its musculature provide sufficient protection for the vast majority of everyday users. With the use of these devices becoming more widespread and commercially available to the general public without training, great care should be taken by the user regarding applied force to the body to prevent self-injury.

Lessons

Given the rise in popularity of personal percussive massage devices, it is important to consider the potential complications of prolonged or excessive massage device use over the cervical spine or other regions of the body. We report the first case of MRI-proven stroke in association with traumatic VAD after the use of a handheld massage device. While causality cannot be invoked, our case highlights the need for further kinetic and biomechanical studies to assess the force distribution from percussive instruments across specialized tissues, muscle, bone, and cervical vasculature in an effort to prevent injuries.

Acknowledgments

We acknowledge the hospital staff including anesthesiologists, radiation technicians, nurses, and patient care technicians who allow for the safe and efficient management of patients.

Disclosures

The authors report no conflict of interest concerning the materials or methods used in this study or the findings specified in this paper.

Author Contributions

Conception and design: Romiyo, Furst, Ellens, Harrigan. Acquisition of data: Romiyo, Furst, George. Analysis and interpretation of data: Romiyo, George. Drafting the article: Romiyo, Furst, Ellens, Bender. Critically revising the article: all authors. Reviewed submitted version of manuscript: Romiyo, Furst, George, Ellens. Approved the final version of the manuscript on behalf of all authors: Romiyo. Study supervision: Ellens, Harrigan.

Correspondence

Prasanth Romiyo: University of Rochester Medical Center, Rochester, NY. prasanth_romiyo@urmc.rochester.edu.

References

  • 1.Schroeder GD Hsu WK.. Vertebral artery injuries in cervical spine surgery. Surg Neurol Int. 2013;4(suppl 5):S362-S367. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Hsu WK, Kannan A, Mai HT.Epidemiology and outcomes of vertebral artery injury in 16 582 cervical spine surgery patients: an AOSpine North America multicenter study. Glob Spine J. 2017;7(1suppl):21S-27S. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Yi HJ.. Epidemiology and management of iatrogenic vertebral artery injury associated with cervical spine surgery. Korean J Neurotrauma. 2022;18(1):34-44. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Inamasu J Guiot BH.. Iatrogenic vertebral artery injury. Acta Neurol Scand. 2005;112(6):349-357. [DOI] [PubMed] [Google Scholar]
  • 5.Yang C Huang X Li Y Sucharit W Sirasaporn P Eungpinichpong W.. Acute effects of percussive massage therapy on thoracolumbar fascia thickness and ultrasound echo intensity in healthy male individuals: a randomized controlled trial. Int J Environ Res Public Health. 2023;20(2):1073. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Sams L Langdown BL Simons J Vseteckova J.. The effect of percussive therapy on musculoskeletal performance and experiences of pain: a systematic literature review. Int J Sports Phys Ther. 2023;18(2):309-327. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Leabeater AJ Clarke AC James L Huynh M Driller M.. Under the gun: percussive massage therapy and physical and perceptual recovery in active adults. J Athl Train. 2024;59(3):310-316. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Wahl LJ.Vibrator device. US patent 2054590A. January 4, 1934. [Google Scholar]
  • 9.Sulkowski K Grant G Brodie T.. Case report: vertebral artery dissection after use of handheld massage gun. Clin Pract Cases Emerg Med. 2022;6(2):159-161. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Shariff E, Al Ghannam ZT, AlDamigh FA.Home self-massage device necessitates public awareness: vertebral artery dissection associated with a home massage device. Cureus. 2023;15(1):e33394. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Chen J Zhang F Chen H Pan H.. Rhabdomyolysis after the use of percussion massage gun: a case report. Phys Ther. 2021;101(1):pzaa199. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Masters AChiang B, Sarvottam K, Patel K. Hemothorax after use of percussion massage gun: a case report. Am J Respir Crit Care Med; 2022. [Google Scholar]
  • 13.Mu J Fan W.. Lens subluxation after use of a percussion massage gun: a case report. Med (Baltim). 2022;101(49):e31825. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Gorrell LM Sawatsky A Edwards WB Herzog W.. Vertebral arteries do not experience tensile force during manual cervical spine manipulation applied to human cadavers. J Man Manip Ther. 2023;31(4):261-269. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Yoganandan N Pintar FA Humm JR Maiman DJ Voo L Merkle A.. Cervical spine injuries, mechanisms, stability and AIS scores from vertical loading applied to military environments. Eur Spine J. 2016;25(7):2193-2201. [DOI] [PubMed] [Google Scholar]
  • 16.Ivancic PC Panjabi MM Ito S.. Cervical spine loads and intervertebral motions during whiplash. Traffic Inj Prev. 2006;7(4):389-399. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Neurosurgery: Case Lessons are provided here courtesy of American Association of Neurological Surgeons

RESOURCES