Significance
Elucidating how internal signals from the body influence the processing of external information from the environment is key to our understanding of perception and cognition in health and pathological conditions. Here, by testing comatose patients, we identify a mechanism by which the unconscious human brain uses ongoing inputs from the heart to track sequences of auditory stimuli. The interplay of heart signals and sounds led to changes in brain and heart activity that helped predict coma recovery. We suggest that the integration of internal and external signals extends to unconscious states and may represent an essential and computationally efficient mechanism for the detection of changes and threats in the external world.
Keywords: coma, interoception, auditory processing, EEG, HEP
Abstract
In healthy awake individuals, the neural processing of bodily signals is not only essential for survival but can also influence perception and compete with external stimulus processing. Yet, the mechanism underlying this bidirectional processing of bodily and external stimuli, as well as its persistence or modulation in unconscious states, remains largely unknown. Here, we investigated the role of cardiac activity on auditory regularity processing in coma. We recorded continuous electroencephalography and electrocardiography in 48 comatose patients on the first day after cardiac arrest during a closed-loop auditory paradigm. We tested whether sounds presented in synchrony with the ongoing heartbeat and sounds presented with fixed, isochronous intervals, would facilitate auditory processing, compared to an asynchronous sequence with variable heartbeat-to-sound and sound-to-sound intervals and a baseline without auditory stimulation. To assess sound prediction based on sequence regularity, we introduced sound omissions within the sequences, violating expected auditory patterns. In coma survivors only, the neural omission response differed in the synchronous against both control conditions. These results were corroborated by a multivariate decoding analysis of the single-trial neural responses to the synchronous omissions and baseline wherein survivors exhibited a higher degree of cardio-audio regularity encoding compared to nonsurvivors. Furthermore, omissions within the synchronous sequence elicited a heart rate deceleration exclusively in coma survivors, which was predictive of patient outcome. We show that the unconscious human brain infers on the temporal relationship across cardiac and auditory inputs and that the neural and cardiac correlates of cardio-audio regularity encoding are predictive of patient outcome.
The human brain continuously samples the external environment, a property that is essential for identifying changes or threats in one’s surroundings (1). This process extends beyond conscious wakefulness to altered consciousness states such as sleep and coma, when detecting unexpected changes in the environment can be crucial for survival (2). This is supported by experimental evidence of regularity processing studies suggesting that the brain can still identify and process patterns in sensory stimuli, even when consciousness is altered or absent (3–6). Such studies focus on the identification of electroencephalographic (EEG) responses to the detection of deviance among trains of regular stimuli, particularly utilized in the auditory domain (7). Deviance detection manifests as a characteristic neural response known as mismatch negativity, a differential response to deviant against standard auditory stimuli (8), and observable in conscious wakefulness (8), sleep (5), disorders of consciousness [DoC; (6)] and in the deep unconscious state of coma (3, 4).
Internally generated stimuli from visceral organs such as the heart may also offer an inherent regularity (9). Although humans can sometimes become aware of bodily rhythms through interoception, these signals are primarily processed implicitly. The brain continuously monitors them, regardless of the level of consciousness, to keep track of the body’s state and ensure the organism’s survival (9–12). Indeed, specific to the cardiac signal, previous work has shown the preservation of the neural response to the heartbeat (heartbeat evoked potential or HEP) in reduced vigilance in sleep (13, 14), DoC (15), and the unconscious state of coma (16, 17).
Merging the two lines of investigation, recent experimental evidence has highlighted that the pseudoregularity of the cardiac signal influences auditory processing (18–23). Some of this work has shown that auditory sequences locked to the ongoing heartbeat generate an auditory temporal prediction even in the absence of fixed sound-to-sound intervals, observed in healthy individuals during both wakefulness (18–20) and reduced vigilance in N2 sleep (19). These findings suggest that cardiac signals are processed across vigilance levels and may facilitate prediction of external sensory inputs (9, 24). However, the physiological and neural mechanisms underlying the interaction between bodily rhythms and exteroceptive sensory processing in a deep unconscious state remain largely unexplored. This phenomenon has so far been studied in patients in chronic stages of DoC (21, 23), commonly affected by a high heterogeneity in structural brain damage (25). In these patients, the high misdiagnosis rate often leaves unresolved whether patients may retain residual levels of awareness (26). To date, it is unclear whether and how bodily signals can influence sensory processing in a profound state of unresponsiveness in which the patient cannot be awakened, even with strong stimuli, and in which we can exclude any conscious access to sensory stimuli (25). Addressing these questions is important in light of the proposed role of the neural response to bodily stimuli during the conscious perception of the sensory environment in healthy participants (27–35), as well as for covert consciousness detection in DoC patients (21, 23) and long-term DoC outcome prognostication (15).
This study aims at investigating whether the simultaneous processing of cardiac and auditory signals persists in the deep unconscious state of coma during the first hours after cardiac arrest. During this time window, we can reasonably exclude major widespread structural brain damage (36), allowing for an assessment in a deeply unconscious yet mostly preserved nervous system. We recorded continuous EEG and electrocardiography (ECG) in comatose patients while administering auditory sequences with different embedded regularities and interspersed with random omissions. In the first sequence type, wherein regularity was inferred across external auditory and internal cardiac signals, administered sounds occurred at a fixed interval following each real-time detected heartbeat (synchronous or synch). In the second sequence type, wherein regularity existed only between external stimuli, sounds were presented with a fixed sound-to-sound interval (isochronous or isoch). The third sequence type presented variable sound-to-sound and heartbeat-to-sound intervals (asynchronous or asynch), i.e., no regularity between successive auditory stimuli and across cardiac and auditory stimuli. A baseline without auditory stimulation served as an additional control. Based on previous findings showing preserved cardio-audio integration during altered consciousness in N2 sleep (19), we hypothesized that cardio-audio regularity encoding may be preserved even without conscious access to auditory stimuli, and it can therefore be observable in comatose patients. We further hypothesized that the degree of preservation of the neural and peripheral response to cardiac signals and its influence on auditory stimulus processing in coma can provide a prognostic marker for patient outcome. We thus expected to observe evidence of facilitated auditory prediction in the synch condition compared to the asynch or baseline control conditions (where no such regularity could be inferred), and that this effect would selectively be observed in patients who ultimately recover.
Results
Comatose Patient Characteristics.
High-density EEG recordings were acquired in 64 comatose patients within 28 h after cardiac arrest. Data from 16 patients were excluded due to irregularities in the ECG signal [a variety of abnormal ECG features (37)] wherein the R peaks could not be easily identified, resulting in faulty auditory stimulus administration in the synch condition. Therefore, a total of 48 patients (SI Appendix, Table S1) were included in the analysis, of which 31 had favorable outcome (FO). During the recordings, patients were unconscious as verified by the full outline of unresponsiveness (FOUR) score of less than or equal to eight (38).
Neural Omission Response.
We investigated the neural response to omissions during cardio-audio regularity processing in comatose patients by contrasting the synch condition with a fixed interval between heartbeat and sound, to the asynch condition with variable heartbeat-to-sound and sound-to-sound intervals, and to the baseline condition without auditory stimulation (Fig. 1). Next, we contrasted the asynch and baseline conditions to the isoch condition, with fixed sound-to-sound intervals (Fig. 1), to identify whether external auditory regularities are processed.
Fig. 1.
Overview of the experimental design and exemplar results. EEG was acquired in comatose patients on the first day of coma after cardiac arrest. Two regular auditory conditions were acquired: in the synch condition, the R peaks in the ECG signal were detected in real time and sounds were administered at a fixed R peak-to-sound interval; in the isoch condition, the median R peak-to-R peak interval served as the fixed sound-to-sound interval. In the control condition, asynch, there was no specific regularity. Sound omissions occurred pseudorandomly for 20% of trials. At 3 mo, patients’ outcome was classified as favorable or unfavorable based on the Cerebral Performance Category (CPC) and the neural responses to the different regularity types recorded on the first day were retrospectively analyzed. Grand-average auditory and omission evoked responses for eight central electrodes and associated topographies across all electrodes in the isoch condition for a subset of favorable (N = 12) and unfavorable (N = 11) patients with similar sound-to-sound intervals are shown at the Bottom.
To investigate the effect of cardio-audio synchronicity on omission responses, we compared the HEPs during sound omissions (OHEPs; time-locked to the first R peak of the ECG during omissions) in the synch and asynch conditions for FO (N = 31) and unfavorable outcome (UO; N = 17) patients. We hypothesized that differences in OHEPs would be observed in FO patients upon contrasting the synch vs. asynch and synch vs. baseline, due to the predictability of sound onset in the synch, based on the fixed delay between R peaks and sounds (19). No differences were expected when comparing asynch and baseline or for all comparisons in UO patients.
In FO patients, cluster-based permutation statistical analysis indicated a significant effect of Condition (P < 0.05, two-tailed) when comparing synch and asynch (Fig. 2A). A spatiotemporal cluster of negative polarity extended from −99 to 47 ms at frontocentral electrodes (P < 0.05, Cohen’s d = 0.73) and a second cluster of positive polarity was observed from −99 to 118 ms at posterior electrodes (P < 0.05, Cohen’s d = 0.77). A third cluster of negative polarity extended between 313 to 500 ms at posterior electrodes following R peak onset (P < 0.05, Cohen’s d = 0.50). A significant effect of Condition (P < 0.05, two-tailed) was additionally observed when contrasting synch and baseline using cluster-based permutation statistics. We revealed a cluster of negative polarity between 245 and 500 ms at posterior electrodes (P < 0.01, Cohen’s d = 0.59) and a cluster of positive polarity between 245 and 482 ms at frontocentral electrodes (P < 0.05, Cohen’s d = 0.59). Finally, a cluster of positive polarity occurred from −96 to 53 ms at posterior electrodes (P < 0.05, Cohen’s d = 0.54). We additionally compared the two control conditions, asynch and baseline, which indicated no significant effect of Condition (P > 0.05, two-tailed). Finally, in UO patients (Fig. 2B), the cluster-based permutation test did not reveal a significant effect of Condition for any of these comparisons (P > 0.05, two-tailed). Our results suggest that, in FO patients, cardiac and auditory inputs were integrated, facilitating auditory regularity encoding.
Fig. 2.
Cardio-audio neural omission response in coma patients. (A) HEPs during sound omissions for the synch compared to the asynch and baseline conditions in FO (N = 31) patients. Top panels display the grand-average EEG waveforms (shaded regions indicate ±SEM) averaged over all electrodes (shown in the corresponding blank topoplots) in the clusters of negative polarity identified following cluster-based permutation statistical analysis (P < 0.05, two-tailed). Bottom panels display the number of electrodes within spatiotemporal clusters and the topography differences at the maximal number of electrodes with electrodes in the cluster highlighted in black. (B) HEPs during sound omissions for the synch compared to the asynch and baseline conditions in UO (N = 17) patients. In the absence of a significant effect of Condition in the UO synch vs. asynch comparison, activity was averaged over electrodes in the synch vs. asynch FO cluster. Similarly, for the UO synch vs. baseline and the FO and UO asynch vs. baseline comparisons, activity was averaged over electrodes in the synch vs. baseline FO cluster.
As a necessary condition for the presence of neural omission responses, we verified that there was a significant difference between auditory evoked potentials (AEPs) and OHEPs in the synch condition, the only auditory sequence where we found evidence of an omission response. To do so, we contrasted the synch AEPs and OHEPs in FO patients (SI Appendix, Fig. S1). The cluster permutation test contrasting the synch OHEPs and AEPs resulted in a significant effect of Evoked Potential Type (P < 0.05, two-tailed). We observed two spatiotemporal clusters which extended across multiple timepoints after stimulus onset: a first of positive polarity between 263 and 397 ms (P < 0.05, Cohen’s d = 0.94) and a second of negative polarity between 253 and 394 ms (P < 0.05, Cohen’s d = 0.91). This provided group-level evidence of preserved auditory processing in the synch condition for FO patients.
Next, we investigated auditory regularity violation in the isoch sequence (SI Appendix, Fig. S2). We compared omission evoked potentials (OEPs; time-locked to the expected sound onset during the omission period) in the isoch and asynch conditions, as well as each of the conditions to the baseline. We observed no effect of Condition (P > 0.05, two-tailed) for both FO and UO patients when contrasting OEPs from the isoch and asynch, isoch and baseline or asynch and baseline using cluster-based permutation statistics. Overall, these results point to a lack of evidence that the brain can build an expectation of upcoming sounds in the isoch or asynch condition for both patient populations.
Multivariate Decoding of Cardio-Audio Neural Omission Response.
We conducted a multivariate decoding analysis using linear support vector machines (SVM) to estimate the prognostic value of cardio-audio regularity encoding for long-term patient outcome. We decoded single-trial EEG responses to omissions in the synch and baseline condition and measured the decoding performance based on the area under the receiver operating characteristic curve (AUC) and the accuracy. Input features for the SVM were the timepoint-by-timepoint EEG amplitude between −100 and 500 ms across the 62 electrodes. This resulted in an AUC and accuracy value for each timepoint and patient, which were associated to a P-value obtained following permutation testing.
To derive a prognostic marker for each patient, we first separated patients into five training (~79%) and five independent test (~21%) sets in a fivefold cross-validation procedure. Next, for each fold, we identified discriminative intervals in the AUC and accuracy between FO and UO patients in the training set. We found discriminative intervals for the AUC-based decoding performance of FO and UO in each training dataset, with similar intervals identified in all folds (402 to 415 ms for the representative fold in Fig. 3A). Along discriminative intervals, in the training datasets, the mean(±SD) AUC was 0.61 ± 0.01 for FOs and 0.58 ± 0.03 for UOs. Accuracy showed differences between FO and UO patients at similar latencies (403 to 416 ms for the representative fold in Fig. 3D). Using these discriminative intervals, mean accuracy was 0.59 ± 0.02 for FOs and 0.56 ± 0.02 for UOs in the training sets.
Fig. 3.
Single-trial multivariate decoding classification in coma patients. (A) Grand-average AUC for the classification of synch and baseline OHEPs in FO (N = 24) and UO (N = 14) patients in a training subset for a representative cross-validation fold. Gray rectangles show the discriminative interval identified when comparing FO and UO patients. Shaded areas indicate ±SEM across patients. (B) Exemplar patients’ AUC is plotted over time. Periods in purple for FO and yellow for UO at the bottom of the exemplar patients’ panels demonstrate the samples at which the decoding performance between synch and baseline was significant (P < 0.001). (C) Individual patients’ average AUC in the training and test (FO: N = 7; UO: N = 3) subset of patients for a representative cross-validation fold, based on the EEG signal extracted during the discriminative intervals with differences as shown in (A). Filled points indicate patients for which the discriminative interval was significant upon permutation testing at the single patient level and hollow points the remaining patients. Black circles indicate the FO and UO exemplar patients for which the AUC (in B) is plotted over time. The same figures are plotted in (D–F) for the accuracy of multivariate decoding. TP: true positive, FN: false negative, FP: false positive, TN: true negative.
Next, we assessed whether the decoding performance upon classifying synch and baseline trials in unseen test patients was predictive of patient outcome. To do so, we evaluated the AUC and accuracy along the discriminative intervals identified during training for each patient in the five independent test sets. We considered a patient correctly predicted as FO if during these discriminative intervals, decoding AUC or accuracy was significant (P < 0.001) based on permutation statistics (Fig. 3 B and E). Across test sets, the mean decoding performance based on AUC was 0.62 ± 0.03 (mean ± SD) in FO and 0.57 ± 0.06 in UO patients. Importantly, a higher number of FO patients exhibited significant AUC decoding values compared to UO patients. In a representative test set, AUC was significant for 5 out of 7 FOs and 1 out of 3 UOs (Fig. 3C). Similar values were obtained across test sets, with an average percentage of patients with significant AUC of 71 ± 14% for FO and 33 ± 41% for UO. Across test sets, this yielded a sensitivity of 0.71 ± 0.14, specificity of 0.67 ± 0.41, positive predictive value (PPV) of 0.83 ± 0.19, negative predictive value (NPV) of 0.46 ± 0.30 and a balanced accuracy for outcome prediction of 0.69 ± 0.20. Across test sets, decoding accuracy was 0.59 ± 0.02 in FO and 0.57 ± 0.07 in UO patients. Similar to AUC, we identified more FO patients with significant accuracy values compared to UO patients, for example 4 out of 7 FOs and 0 out of 3 UOs in a representative test set (Fig. 3F). Overall, accuracy was significant for 55 ± 14% FO and 22 ± 33% UO patients across test sets. Outcome prediction using accuracy had a sensitivity of 0.55 ± 0.14, specificity of 0.78 ± 0.33, PPV of 0.86 ± 0.20, NPV of 0.47 ± 0.13 and a balanced accuracy for outcome prediction of 0.67 ± 0.15. These results show that the degree of cardio-audio encoding at the single-patient level on the first day of coma after cardiac arrest provides prognostic information on a patient’s chances of recovery.
To investigate whether the ability of the brain to identify cardio-audio regularities depends on the consciousness level, we assessed the relationship between the multivariate decoding performance and the clinical consciousness level score in comatose patients i.e., FOUR score (38). The mean AUC and accuracy values along the discriminative intervals in the five cross-validation folds (as above) were extracted in patients for which the FOUR score was available (N = 40), independent of patient outcome. Skipped Spearman correlations revealed no significant correlations (P > 0.05) between the patients’ FOUR and the AUC or accuracy in all five cross-validation folds for the synch and baseline single-trial decoding.
Auditory Evoked Response.
To corroborate that any differences observed in the group-level and single-patient comparisons of FO and UO patients were not trivially driven by differences in hearing ability between the two populations, we investigated whether AEPs were preserved at the single-patient level (SI Appendix, Fig. S3). A multivariate decoding analysis (as described above for synch vs. baseline) was performed to classify isoch AEPs and baseline. We identified significant decoding performance across multiple timepoints after sound onset in all FO and UO patients indicating preserved auditory processing in all patients, irrespective of outcome. In more detail, the AUC was significant in 364 ± 113 (Mean ± SD) and 345 ± 97 timepoints for FO and UO patients, respectively. A 1 × 2 Kruskal–Wallis ANOVA contrasting the number of significant timepoints for AUC in FO and UO patients was not significant (χ2 = 0.20, P = 0.66). Accuracy was significant in 375 ± 97 and 348 ± 86 timepoints for FO and UO patients, respectively, with no significant differences between the two patient populations (χ2 = 0.48, P = 0.49). Grand-average maximum AUC values over all significant timepoints after permutation testing were also not significantly different between the two groups of patients (χ2 = 0.80, P = 0.37) with mean(±SD) values of 0.65 ± 0.05 for FO and 0.64 ± 0.03 for UO. Similarly, grand-average maximum accuracy was 0.64 ± 0.03 for FO patients and 0.63 ± 0.03 for UO patients without statistically significant differences between patient populations (χ2 = 1.14, P = 0.29).
Cardiac Omission Response.
We investigated whether omissions in the auditory sequences elicited cardiac responses, measured using ECG in comatose patients. We analyzed heartbeat changes upon sound omission within the auditory sequences. We compared average R peak-to-R peak (RR) intervals before, during and after omissions using two-way repeated measures ANOVAs with factors Auditory Condition (synch, asynch, isoch) and Trial Order (one trial before, trial during, first trial after, second trial after sound omissions) in FO and UO patients. We normalized RR intervals by dividing each patient’s average RR interval by the average RR interval prior to omission, to account for interpatient variability in heart rate.
In FO patients only, we observed that cardio-audio regularity led to an increase in the average RR interval during omissions (RRom) compared to the trial before omission (RR−1) that persisted over the next trial (RR+1) and decreased over the second trial following omission (RR+2) (Fig. 4A). 3 × 4 repeated measures ANOVAs revealed a significant interaction of Auditory Condition × Trial Order for FO patients (F(3, 4) = 4.81, P < 0.001) with significant main effects of Auditory Condition (F(3, 1) = 6.86, P < 0.01) and Trial Order (F(1, 4) = 8.51, P < 0.001). Permutation testing followed by Wilcoxon signed-rank tests comparing the distribution of postpermutation F values against the original F values confirmed the significance of the main effects and interactions (P < 0.001). Post hoc Wilcoxon signed-rank tests with Bonferroni correction across conditions corroborated that in the synch condition, omissions elicited a long-lasting heart rate deceleration, with higher RRom compared to RR−1 (P < 0.001) that persisted over upcoming trials (P < 0.001). This deceleration in the heart rate was not present in the asynch in the absence of auditory regularity. In the isoch condition, and for FO patients only, post hoc comparisons revealed a less pronounced, yet consistent deceleration upon omission alone (P < 0.001) which did not persist over upcoming trials. In UO patients, we found no significant results (Fig. 4B; F(3, 4) = 1.54, P = 0.22; F(3, 1) = 0.05, P = 0.95; F(1, 4) = 0.36, P = 0.90).
Fig. 4.
Cardiac omission response in coma patients. (A and B) Single-patient swarm plots of normalized RR intervals prior (RR−1), during (RRom), and following (RR+1 and RR+2) the omission of sounds within auditory sequences (synch, asynch, isoch) in FO (A; N = 31) and UO (B; N = 17) patients. Grand-average normalized RR for the same intervals with error bars indicating the ±SD are shown in the Bottom panels. Repeated measures ANOVAs and post hoc Wilcoxon signed-rank tests revealed a significant (P < 0.001) heart rate deceleration upon omission that persisted over upcoming trials in FO patients for the synch condition. (C) Log normalized (for visualization purposes) RRom, RR+1 and RR+2 intervals within the synch condition. x denotes the mean value for each interval. Maximal cardiac deceleration observed at interval RRom indicated a FO patient predicted correctly [true positive (TP); filled dots] or a UO patient predicted incorrectly [false positive (FP); empty dots]. Conversely, maximal deceleration at intervals RR+1 or RR+2 indicated an UO patient predicted correctly [true negative (TN); filled dots] or a FO patient predicted incorrectly [false negative (FN); empty dots].
Outcome Prediction Based on the Cardio-Audio Cardiac Omission Response.
We explored whether the cardiac deceleration during omission in the synch condition was predictive of patient outcome. We identified the RR interval upon sound omission which produced the maximal cardiac deceleration within the three intervals during and after the omission. In more detail, a FO patient predicted correctly (true positive) would have maximal deceleration at RRom and not at subsequent intervals (RR+1 or RR+2) and an UO patient predicted correctly (true negative) would have maximal deceleration at subsequent intervals and not at RRom (Fig. 4C). Twenty-four out of 31 FOs (77%) had maximal deceleration during the omission, whereas only 6 out of 17 UOs (35%) had it in the same interval. Prediction based on this prognostic marker had a sensitivity of 0.77, specificity of 0.65, PPV of 0.80, NPV of 0.61, and balanced accuracy of 0.71.
Discussion
We investigated a potential role for cardiac signals upon auditory regularity processing in the absence of consciousness. We hypothesized that in the deep unconsciousness of coma, the continuously monitored cardiac signal may be utilized by the patients’ brain to facilitate auditory prediction, and that patients in a severe clinical condition (i.e., UO patients) may exhibit less preservation of this mechanism. In agreement with our hypothesis, we identified a neural and cardiac correlate of violated auditory expectation in FO patients, which was absent in UO patients. At the group-level, a neural response to sound omissions in FO patients was only evident upon contrasting the synch to the asynch and baseline and absent in the isoch, while the same comparisons in UO patients produced no significant results. Consistently, multivariate decoding of the synch and baseline EEG trials at the single-patient level was informative of the patients’ long-term outcome. Exclusively in FO patients, we additionally observed a cardiac violation response as a deceleration of the ongoing heart rate upon sound omission in the synch, which also provided predictive information for patient outcome. Overall, these results suggest that the human brain infers on the relationship between internally generated cardiac and external auditory inputs, even in the deep unconscious state of acute coma.
The group-level significant effect observed in comatose patients with FO when contrasting the cardio-audio regularity and the control conditions’ OHEPs (Fig. 2A), was previously reported in healthy individuals during conscious wakefulness (18, 19) and altered consciousness in N2 sleep (19). Importantly, in wakefulness and N2 sleep, a significant effect was also identified upon comparing external sound-to-sound regularities (isoch) to the irregular condition (asynch) (19). However, in FO patients, we found no significant effect of condition when comparing the isoch and the control conditions. This serves as indirect support to the hypothesis that in the absence of consciousness, internally generated signals like the heartbeat, constitute an effective temporal cue for the generation of an anticipatory response to upcoming sounds and a violation response upon sound omission (12). While sound-to-sound regularity (isoch) did not induce subtle omission responses in FO or UO patients, the temporal relationship across cardiac and auditory inputs (synch) was informative for regularity encoding, mostly in FO patients who ultimately recovered.
The use of omissions, which to the best of our knowledge have not been previously investigated in DoC, offers a unique opportunity to elaborate on the origins of preserved cardio-audio regularity processing in comatose patients. According to the predictive coding framework, differential neural responses to deviant stimuli upon regularity encoding are a consequence of a prediction error signal when the sequences diverge from the expected pattern (8, 39). In omissions, unlike deviant sounds which have been commonly studied in DoC (3, 4, 6, 21, 23), the violation detection signal is free from the bottom–up contribution of auditory stimulus processing and rather represents a top–down prediction error signal when the expectation of the sound is violated (40–42). The absence of omission responses in the isoch, i.e., to purely external auditory regularities, highlights the relevance of cardiac inputs in informing auditory regularity prediction, which requires higher-order integration, mostly preserved in coma survivors (43). Instead, permanent damage to the cortical regions shared between interoception and perception pathways like the somatosensory cortices, anterior cingulate cortex, auditory cortices, and ventromedial prefrontal cortex (9, 44, 45) could compromise the integration of the two stimuli types, as the brain attempts to update its model of the external and internal state (46).
The presence of surprise responses following the violation of cardio-audio regularity in the synch condition extended beyond the group, to the single-subject, observed using a multivariate decoding analysis of synch and baseline OHEP trials (Fig. 3). FO patients had a higher decoding score compared to UO patients, which yielded predictive value for patients’ long-term outcome. These findings are in line with previous studies investigating the neural response to the heartbeat and demonstrating its potential value as a marker for the stratification of chronic DoC patients (15). Previous work also showed that the strength of the HEP following auditory stimuli was informative of covert consciousness in DoC patients (21, 23). Importantly, while these latter studies investigated the consequence of auditory regularity encoding and its impact on HEPs, our investigation allows to directly assess both the bottom–up and top–down integration of cardiac and auditory signals, due to our closed-loop design. This in turn suggests that the integration of cardiac and auditory inputs and their bidirectional influence, is not uniquely present when external stimuli are consciously accessed.
Additional evidence of preserved cardio-audio regularity processing in coma patients comes from our results of alterations in cardiac activity in response to sound omissions. We observed a pronounced deceleration of the heart rate upon omission in the synch, evident only in patients with FO (Fig. 4), and therefore predictive of patient outcome. The absence of similar results in UO patients may be due to disrupted interoceptive pathways and limited flexibility of the cardiac rhythm, that has been observed even in the absence of auditory stimulation (47). These results in FO patients parallel the same findings in healthy participants where a persistent cardiac deceleration upon omissions from cardio-audio synchronous sequences was observed in wakefulness and all stages of sleep (19). The convergence of these findings suggests that the mechanism underlying cardio-audio regularity encoding, which elicits a cardiac deceleration upon omission of the expected sound, is shared across conscious and unconscious states.
This work has several limitations to consider. First, comatose patients were in the intensive care unit following a cardiac arrest of primarily cardiac etiology. This resulted in many patients (N = 16) being excluded from the analysis due to abnormal ECG features and hence, the uncontrolled real-time administration of the synch sequence. Future work will attempt to investigate the processing of cardio-audio regularities in comatose patients of different etiologies, thereby ensuring a reduced number of excluded patients. The impact of data acquisition in the intensive care unit on signal quality should also be noted as, in our study, it sometimes resulted in several artifacted, and therefore interpolated, electrodes [average of 13% herein against the recommended 10% (48)]. Second, while normal hearing was an inclusion criterion for the patients, and we found no evidence of differences between AEPs in FO and UO patients, we cannot exclude potential differences in hearing ability between FO and UO patients in this aging cohort. This could be addressed in future work, by including a systematic evaluation of basic hearing ability using, for example, auditory brainstem responses or otoacoustic emissions. Third, resting RR interval and variability differences between FO and UO comatose patients, commonly described in the literature (47), were also observed in this study (SI Appendix, Fig. S4). Due to the relationship between cardiac rhythm and sound administration herein, we cannot exclude that resting RR interval and variability differences may influence cardio-audio regularity inference.
To conclude, the early hours after coma onset offer a unique state during which the integration of interoceptive and exteroceptive stimuli provides a marker of preservation of the neural circuits which are functionally relevant for later recovery.
Materials and Methods
The study was approved by the local ethics committee, The Cantonal Ethics Committee for Research on Human Beings [https://www.cer-vd.ch/, PB_2016-00530 (23/05)], in accordance with the Helsinki declaration. Written informed consent was obtained for all patients in accordance with the ethical agreement.
Comatose Patients.
EEG and ECG data were prospectively acquired in 64 comatose patients at the intensive care unit of Bern University Hospital between May 2017 and July 2022. Patients were excluded if they had a pacemaker resulting in no heart rate variability. Electrophysiological data were acquired within the first 28 h of coma after cardiac arrest. Patient temperature was controlled using ice packs or cooling pads/cooling catheter with a feedback-controlled cooling device (Arctic Sun System, medivance, Louisville, USA or thermogard XP, ZOLL Medical, Zug, Switzerland). Patients were administered neuromuscular blocking agents to control shivering when needed. Fentanyl, propofol, and/or midazolam were used for analgesia-sedation. The patients’ functional and neurological condition was evaluated using the FOUR score (38).
A multimodal approach was used for the decision of withdrawal of life-sustaining therapy at least 72 h after cardiac arrest, according to the European Society of Intensive Medicine guidelines (49, 50), when the patient had a Glasgow Coma Scale motor score of ≤3, and at least two of the following: i) incomplete return of the pupillary and corneal reflexes; ii) treatment-resistant early myoclonus or status epilepticus; iii) bilateral absence of cortical somatosensory evoked potentials; iv) unreactive EEG background activity after sedation weaning; v) markedly elevated NSE (i.e., >60 µg/L); vi) extended posthypoxic lesion in the CT or MRI. Clinical EEG features including reactivity, discontinuity, epileptiform features were assessed by a board certified neurologist (FZ) in a separate EEG recording (51).
Patients were classified according to the best functional outcome at 3 mo post cardiac arrest using a semistructured phone interview to evaluate the Cerebral Performance Category [CPC; (52)]. Classification was dichotomized to FO (CPC = 1 to 2) and UO (CPC = 3 to 5). Clinical decisions were independent of and blinded to the retrospective analysis described herein.
Patient clinical characteristics were assessed to evaluate whether significant differences existed between FO and UO. Time to return of spontaneous circulation, age, latency of EEG acquisition, temperature during EEG acquisition, the FOUR score and sedative concentrations (fentanyl, propofol, midazolam) were contrasted between FOs and UOs using nonparametric 1 × 2 Kruskal–Wallis ANOVAs (P < 0.05) with within-subject factor Patient (FO, UO). Binary measures of gender, etiology of cardiac arrest (cardiac, pulmonary), number of sedated patients (fentanyl, propofol, midazolam), presence of brainstem reflexes, and clinical EEG features (reactivity, discontinuity, epileptiform activity) were assessed using Fisher’s exact tests (P < 0.05) contrasting FO and UO patients.
Experimental Procedures.
EEG was acquired at 1,200 Hz from 63 active ring electrodes (g.tec medical engineering, Graz, Austria) arranged according to the international 10 to 10 system. Electrode AFz served as the ground, the right ear lobe served as the online reference and both the left and right ear lobes as the offline reference. Three-lead ECG and horizontal and vertical electrooculography were additionally acquired. Impedances for all electrodes were below 30 kΩ.
Four types of experimental conditions were administered in separate experimental blocks in a pseudorandom order using MATLAB Simulink (R2017b, The MathWorks, Natick, MA). The conditions were a baseline condition without auditory stimulation and three auditory conditions: synch, asynch, and isoch. The baseline condition lasted 20 min and was acquired prior to auditory stimulation. The auditory conditions lasted approximately 10 min each (depending on the patient’s heart rate) and were repeated twice in a pseudorandom order. Each auditory condition consisted of the sequential presentation of 500 stimuli which were 400 sounds (80%) and 100 omissions [20% (18, 19), although see refs. 40–42 for paradigms using a lower percentage of omissions]. Sound stimuli were 1,000 Hz sinusoidal tones of 100 ms duration with 5 ms rise and fall times and 0 μs interaural time difference. A 10 ms linear amplitude envelope was applied at stimulus onset and offset to avoid clicks. Stimuli were 16-bit stereo sounds sampled at 44.1 kHz and were presented binaurally with fixed intensity. Stimulus presentation followed a pseudorandom distribution where omissions could be presented after one and up to seven sound stimuli.
In the synch condition, we administered sounds (or omissions) at a fixed interval after the R peaks of the ECG signal. R peaks were detected in real-time by computing the variance over the preceding 50 ms time window and identifying the R peak when the online ECG variance surpassed a 10 to 15 mV2 threshold, adjusted for each patient. This procedure resulted in a fixed R peak-to-sound average delay (i.e., RS interval) of 46 ms and RS variability (SD of RS intervals here and elsewhere) of 5 ms across patients (SI Appendix, Fig. S4A). Conversely, the isoch and asynch conditions had no fixed relationship to the ongoing heartbeat and therefore had variable RS intervals (SI Appendix, Fig. S4A), verified in post hoc analyses investigating the single-subject RS intervals (see SI Appendix, Fig. S5 for the isoch). For the remaining auditory conditions, the ECG acquired during the baseline block was processed to extract RR intervals. In the isoch condition, the baseline median RR interval was computed and used as the fixed SS interval. In the asynch condition, the sound sequence was generated by randomly selecting and shuffling 500 RR intervals within the baseline. This resulted in a pseudorandom auditory sequence closely resembling that of the synch condition. As expected, SS variability was low only in the isoch with a value of 1 ms compared to the synch and asynch condition with values of 24 ms and 19 ms, respectively (SI Appendix, Fig. S4B). No differences in RR intervals or variability were observed between synch, asynch, isoch, and baseline (SI Appendix, Fig. S4C).
Data Analysis.
Data were analyzed in MATLAB (R2019b, The MathWorks, Natick, MA) using open-source toolboxes EEGLAB [13.4.4b, (53)], Fieldtrip [20201205, (54)] and custom-made scripts.
The R peaks in the continuous raw ECG signal were detected offline using a semiautomated approach (18, 19). peakdetect.m (https://ch.mathworks.com/matlabcentral/fileexchange/72-peakdetect-m/content/peakdetect.m) was utilized to automatically identify the R peaks in the raw ECG signal. Visual inspection of the online and offline detected R peaks verified the correct administration of the synch condition which if not met, resulted in the exclusion of the patient.
EEG Preprocessing.
Continuous raw EEG data were band-pass filtered using second-order Butterworth filters between 0.1 and 40 Hz. Independent Component Analysis (54) was used to identify and remove any cardiac field, eye or muscle related components. Next, EEG data were epoched between −100 and 500 ms relative to the selected event onset (18, 19). For the auditory conditions, event onsets included sounds for AEPs, the closest R peak during omission for OHEPs, and the expected omission onset (average SS interval added to the sound onset before the omission) for OEPs. For the baseline (without auditory stimulation), event onsets included the R peaks for HEPs, and the R peaks matched on the single-trial level to the trial onsets in the sound-based isoch and asynch OEPs.
Artifact electrodes and trials were identified using a semiautomated approach for artifact rejection by utilizing ft_rejectvisual (https://github.com/fieldtrip/fieldtrip/blob/master/ft_rejectvisual.m) (54), verified by the visual inspection of selected electrodes and trials. Artifact trials were excluded and artifacted electrodes were interpolated. An average(±SD) of 7.3 ± 2.2 and 8.9 ± 1.1 electrodes were interpolated in FOs and UOs, respectively. The number of baseline trials was quantitatively matched to those in the synch, asynch, and isoch. In addition, for asynch OHEPs, trials where the previous sound occurred less than 400 ms before the omission R peak onset were excluded to prevent the overlap between the AEP and OHEP. The final number of trials is shown in SI Appendix, Table S2. Finally, the data were rereferenced to the common average.
EEG Group-Level Statistical Analysis.
Nonparametric cluster-based permutation statistics with 5,000 permutations [P < 0.05, two-tailed; (55)] were used to investigate EEG-based differences between the experimental conditions. Under this statistical framework, statistically significant individual data samples were grouped based on the degree of their shared spatial and temporal characteristics. This procedure was performed over the entire trial length (between −100 and 500 ms). Effect sizes for significant differences were evaluated using the Cohen’s d statistic at the latencies of the largest number of electrodes in significant clusters.
We also carried out a control analysis on the ECG waveforms to exclude the potential confound of a different degree of contamination of the ECG artifacts in the HEP analysis between conditions of interest. We performed a time-wise ECG waveform comparison of the average ECG trials time-locked to R peaks during sound omissions using cluster permutation statistics (P < 0.05, two-tailed) contrasting paired experimental conditions (synch, asynch, isoch, baseline). As expected, no significant differences existed in FO or UO patients (SI Appendix, Fig. S6).
EEG Single-Patient Multivariate Decoding Analysis.
We attempted to evaluate cardio-audio encoding at the single-patient level and to relate it to the outcome and consciousness level clinical assessment. We hypothesized that a higher number of patients with preserved cardio-audio encoding would have FO compared to UO and that the degree of this preservation had prognostic value. To verify this hypothesis, we implemented a multivariate decoding algorithm with the aim of evaluating the significance of the cardio-audio encoding at the single-patient level and its prognostic value. We considered the single-trial EEG responses to omissions during the synch compared to the single-trial EEG extracted during the baseline at the same latencies with respect to the R peak of the ECG signals. The following analysis was also performed for the single-trial classification of isoch AEPs and baseline to verify no differences in AEPs between FO and UO patients at the single-patient level.
Multivariate decoding was based on a linear SVM classifier, as implemented in MATLAB (fitclinear.m). Input features for the SVM were the EEG amplitude at every timepoint between −100 and 500 ms relative to the R peak of the ECG signal (720 timepoints for trials between −100 and 500 ms sampled at 1,200 Hz) across the 62 electrodes. A SVM model was computed at each timepoint on a learning dataset including 240 trials (~65% of total trials; 120 trials for each condition). The remaining trials were used to evaluate the performance of the multivariate decoding. Performance was evaluated based on the AUC and accuracy. To assess the significance of the cardio-audio decoding performance at the single-patient level, the AUC and accuracy were statistically compared to chance level using permutation statistics at each timepoint via 500 random permutations, i.e., comparing the actual decoding performance in the evaluation set to the distribution of the performance based on random permutations of the learning dataset (Wilcoxon signed-rank test, P < 6.94 × 10−5 with Bonferroni correction across timepoints). This analysis resulted in a P-value for AUC and accuracy obtained via the permutation test at each timepoint.
Next, in a fivefold cross-validation procedure, the cohort of coma patients was divided in five training sets (~79%), used for parameter selection and outcome predictive value evaluation, and five nonoverlapping test sets (~21%), used to assess whether this predictive value generalizes to unseen data. In each cross-validation fold, to derive a predictive marker, we attempted to identify the time intervals at which FO and UO patients exhibited differences in decoding performance in the training set (discriminative intervals). To do so, we computed the difference between the mean AUC and accuracy in the FO and UO training set and computed the mean and SD of the absolute values of this difference. To identify the discriminative intervals, we selected timepoints for which the difference in the AUC or accuracy between FO and UO patients at group-level exceeded a threshold of mean + 2 SD or was below a threshold of mean − 2 SD. With this selection of discriminative intervals, we did not impose a higher or lower AUC (or accuracy) for FO vs. UO patients. Finally, discriminative intervals were identified if they contained at least 15 consecutive timepoints that met this threshold. In the requirement of consecutive timepoints, we had a tolerance of five timepoints such that any gap of significance for up to five timepoints was ignored. For each patient, the mean AUC and accuracy along the identified discriminative interval was used as the outcome predictive score for FO and UO patients. A patient was predicted as FO (true positive) if the decoding performance in classifying synch vs. baseline trials was significant (P < 6.94 × 10−5) at all timepoints within the discriminative interval. The predictive performance based on AUC or accuracy was assessed in each test set using the sensitivity, specificity, PPV, NPV, and balanced accuracy [(sensitivity+specificity)/2]. The average performance of these values is reported only for the independent test sets as they represent an unbiased evaluation of the predictive value of the proposed marker.
We further investigated whether the multivariate decoding performance varied in different consciousness levels based on the clinical assessment using the FOUR score. For each cross-validation fold, across training and test datasets, we tested the skipped Spearman correlation [(56), P < 0.05] between patient consciousness level, using the FOUR score in patients with this information available (N = 40) and the AUC and accuracy predictive score.
ECG Analysis.
Continuous ECG data were used to derive omission-related RR intervals. The omission RR interval (RRom) was identified by subtracting the latency of the first R peak following an omission from the one preceding it (the omission onset was obtained by adding the average SS interval within each block to the sound onset prior to the omission). Additional RR intervals were calculated using contiguous R peaks as the RR interval for the trial prior to the sound omission (RR−1) and up to two trials following the omission (RR+1 and RR+2) with no RR overlap. Unrealistic RR intervals, following flawed R peak detection, were identified, and excluded using the rmoutliers.m MATLAB function and visual inspection. Finally, RR intervals were normalized for each patient and condition by dividing the average RR intervals (RRom, RR+1 and RR+2) by the average RR−1 interval.
3 × 4 repeated measures ANOVAs were performed on the average RR intervals with within-subject factors Auditory Condition (synch, asynch, isoch) and Trial Order (RR−1, RRom, RR+1 and RR+2), for FO and UO patients separately. To reject the null hypothesis that no significant differences existed in the given set of ANOVA factors being compared, each of the factors’ condition labels were shuffled (5,000 permutations), to estimate the chance-based distribution of maximal cluster-level statistics. Wilcoxon signed-ranked tests (P < 0.05) evaluated whether significant differences existed between the distribution of postpermutation F and the true main effect and interaction effect F values. Post hoc Wilcoxon signed-rank tests with Bonferroni correction (P < 0.017 for auditory condition and P < 0.008 for omission trial order comparisons) were utilized for pairwise comparisons between within-subject variables.
ECG-Based Patient Outcome Prediction.
We evaluated the prognostic value of the cardiac deceleration upon omission in the synch condition in predicting patient outcome. To do so, we identified the RR interval upon sound omission which produced the maximal cardiac deceleration. In more detail, a FO patient predicted correctly (true positive) would have maximal deceleration at RRom and not at subsequent intervals (RR+1 or RR+2) and an UO patient predicted correctly (true negative) would have maximal deceleration at subsequent intervals and not at RRom. The predictive performance was assessed using the sensitivity, specificity, PPV, NPV, and balanced accuracy.
Supplementary Material
Appendix 01 (PDF)
Acknowledgments
We thank Nathalie Ata Nguepnjo Nguissi and all neurophysiology technicians for invaluable help with EEG data acquisition. We are grateful to Rupert Ortner and Christoph Guger from g.tec for technical support. This work was supported by the University of Lausanne grant “Pro-Femmes,” the Swiss NSF (grant 32003B_212981), the Eurostars project E!3489 to M.D.L., the Bertarelli Foundation grant “Catalyst” to S.S. and M.D.L. and the University of Lausanne ‘Transition Grant’ to A.P.
Author contributions
A.P., C.P., M.I., M.H., F.Z., and M.D.L. designed research; A.P., C.P., M.I., M.H., F.Z., and M.D.L. performed research; A.P. and M.D.L. contributed new reagents/analytic tools; A.P. and M.D.L. analyzed data; and A.P., S.S., and M.D.L. wrote the paper.
Competing interests
The authors declare no competing interest.
Footnotes
This article is a PNAS Direct Submission. R.T.K. is a guest editor invited by the Editorial Board.
Contributor Information
Andria Pelentritou, Email: antria.pelentritou@chuv.ch.
Marzia De Lucia, Email: marzia.de-lucia@chuv.ch.
Data, Materials, and Software Availability
Custom-made code used in data analyses have been deposited in GitHub (https://github.com/DNC-EEG-platform/CardioAudio_Coma) (57). The data included in this study are not publicly available due to the sensitive nature of the clinical data under ethical regulations but can be available from the corresponding author on reasonable request.
Supporting Information
References
- 1.de Lange F. P., Heilbron M., Kok P., How do expectations shape perception? Trends Cogn. Sci. 22, 764–779 (2018). [DOI] [PubMed] [Google Scholar]
- 2.Cirelli C., Tononi G., Is sleep essential? PLoS Biol. 6, 1605–1611 (2008). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Tzovara A., et al. , Progression of auditory discrimination based on neural decoding predicts awakening from coma. Brain 136, 81–89 (2013). [DOI] [PubMed] [Google Scholar]
- 4.Tzovara A., et al. , Prediction of awakening from hypothermic postanoxic coma based on auditory discrimination. Ann. Neurol. 79, 748–757 (2016). [DOI] [PubMed] [Google Scholar]
- 5.Strauss M., et al. , Disruption of hierarchical predictive coding during sleep. Proc. Natl. Acad. Sci. U.S.A. 112, E1353–E1362 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Bekinschtein T. A., et al. , Neural signature of the conscious processing of auditory regularities Proc. Natl. Acad. Sci. U.S.A. 106, 1672–1677 (2009). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Heilbron M., Chait M., Great expectations: Is there evidence for predictive coding in auditory cortex? Neuroscience 389, 54–73 (2018). [DOI] [PubMed] [Google Scholar]
- 8.Garrido M. I., Kilner J. M., Stephan K. E., Friston K. J., The mismatch negativity: A review of underlying mechanisms. Clin. Neurophysiol. 120, 453–463 (2009). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Engelen T., Solcà M., Tallon-Baudry C., Interoceptive rhythms in the brain. Nat. Neurosci. 26, 1670–1684 (2023). [DOI] [PubMed] [Google Scholar]
- 10.Kluger D. S., Allen M. G., Gross J., Brain–body states embody complex temporal dynamics. Trends Cogn. Sci. 28, 695–698 (2024). [DOI] [PubMed] [Google Scholar]
- 11.Tsakiris M., Critchley H., Interoception beyond homeostasis: Affect, cognition and mental health. Philos. Trans. R. Soc. Lond. B Biol. Sci. 371, 1–6 (2016). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Candia-Rivera D., Brain-heart interactions in the neurobiology of consciousness. Curr. Res. Neurobiol. 3, 1–10 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Simor P., Bogdány T., Bódizs R., Perakakis P., Cortical monitoring of cardiac activity during rapid eye movement sleep: The heartbeat evoked potential in phasic and tonic rapid-eye-movement microstates. Sleep 44, 1–12 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Lechinger J., Heib D. P. J., Gruber W., Schabus M., Klimesch W., Heartbeat-related EEG amplitude and phase modulations from wakefulness to deep sleep: Interactions with sleep spindles and slow oscillations. Psychophysiology 52, 1441–1450 (2015). [DOI] [PubMed] [Google Scholar]
- 15.Candia-Rivera D., et al. , Neural responses to heartbeats detect residual signs of consciousness during resting state in postcomatose patients. J. Neurosci. 41, 5251–5262 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Candia-Rivera D., Machado C., Multidimensional assessment of heartbeat-evoked responses in disorders of consciousness. Eur. J. Neurosci. 58, 3098–3110 (2023). [DOI] [PubMed] [Google Scholar]
- 17.Schulz A., et al. , Late heartbeat-evoked potentials are associated with survival after cardiac arrest. Resuscitation 126, 7–13 (2018). [DOI] [PubMed] [Google Scholar]
- 18.Pfeiffer C., De Lucia M., Cardio-audio synchronization drives neural surprise response. Sci. Rep. 7, 14842 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Pelentritou A., Pfeiffer C., Schwartz S., De Lucia M., Cardio-audio synchronization elicits neural and cardiac surprise responses in human wakefulness and sleep. Commun. Biol. 7, 226 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Banellis L., Cruse D., Skipping a beat: Heartbeat-evoked potentials reflect predictions during interoceptive-exteroceptive integration. Cereb. Cortex Commun. 1, tgaa060 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Raimondo F., et al. , Brain–heart interactions reveal consciousness in noncommunicating patients. Ann. Neurol. 82, 578–591 (2017). [DOI] [PubMed] [Google Scholar]
- 22.Koroma M., Boulakis P. A., Raimondo F., Cardiac responses to auditory irregularities reveal hierarchical information processing during sleep. bioRxiv [Preprint] (2024), 10.1101/2024.09.24.614090 (Accessed 21 October 2024). [DOI]
- 23.Candia-Rivera D., et al. , Conscious processing of global and local auditory irregularities causes differentiated heartbeat-evoked responses. Elife 12, e75352 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Skora L. I., Livermore J. J. A., Roelofs K., The functional role of cardiac activity in perception and action. Neurosci. Biobehav. Rev. 137, 104655 (2022). [DOI] [PubMed] [Google Scholar]
- 25.Comanducci A., et al. , Clinical and advanced neurophysiology in the prognostic and diagnostic evaluation of disorders of consciousness: Review of an IFCN-endorsed expert group. Clin. Neurophysiol. 131, 2736–2765 (2020). [DOI] [PubMed] [Google Scholar]
- 26.Schnakers C., et al. , Diagnostic accuracy of the vegetative and minimally conscious state: Clinical consensus versus standardized neurobehavioral assessment. BMC Neurol. 9, 35 (2009). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Al E., et al. , Heart-brain interactions shape somatosensory perception and evoked potentials. Proc. Natl. Acad. Sci. U.S.A. 117, 10575–10584 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Leupin V., Britz J., Interoceptive signals shape the earliest markers and neural pathway to awareness at the visual threshold. Proc. Natl. Acad. Sci. U.S.A. 121, e2311953121 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Fouragnan E. F., et al. , Timing along the cardiac cycle modulates neural signals of reward-based learning. Nat. Commun. 15, 2976 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Garfinkel S. N., Seth A. K., Barrett A. B., Suzuki K., Critchley H. D., Knowing your own heart: Distinguishing interoceptive accuracy from interoceptive awareness. Biol. Psychol. 104, 65–74 (2015). [DOI] [PubMed] [Google Scholar]
- 31.Babo-Rebelo M., Buot A., Tallon-Baudry C., Neural responses to heartbeats distinguish self from other during imagination. Neuroimage 191, 10–20 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Park H. D., Tallon-Baudry C., The neural subjective frame: From bodily signals to perceptual consciousness. Philos. Trans. R. Soc. B 369, 20130 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Tallon-Baudry C., Campana F., Park H., Babo-rebelo M., The neural monitoring of visceral inputs, rather than attention, accounts for first-person perspective in conscious vision. Cortex 102, 139–149 (2017). [DOI] [PubMed] [Google Scholar]
- 34.Paci M., et al. , When the heart inhibits the brain: Cardiac phases modulate short-interval intracortical inhibition. iScience 27, 109140 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Galvez-Pol A., Virdee P., Villacampa J., Kilner J. M., Active tactile discrimination is coupled with and modulated by the cardiac cycle. Elife 11, e78126 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Keijzer H. M., et al. , Brain imaging in comatose survivors of cardiac arrest: Pathophysiological correlates and prognostic properties. Resuscitation 133, 124–136 (2018). [DOI] [PubMed] [Google Scholar]
- 37.Gentile F. R., et al. , Association between postresuscitation 12-lead ECG features and early mortality after out-of-hospital cardiac arrest: A post hoc subanalysis of the PEACE study. J. Am. Heart Assoc. 12, 1–17 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Wijdicks E. F. M. M., Bamlet W. R., Maramattom B. V., Manno E. M., McClelland R. L., Validation of a new coma scale: The FOUR score. Ann. Neurol. 58, 585–593 (2005). [DOI] [PubMed] [Google Scholar]
- 39.Friston K., A theory of cortical responses. Philos. Trans. R. Soc. Lond. B Biol. Sci. 360, 815–836 (2005). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Wacongne C., et al. , Evidence for a hierarchy of predictions and prediction errors in human cortex. Proc. Natl. Acad. Sci. U.S.A. 108, 20754–20759 (2011). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Chennu S., et al. , Silent expectations: Dynamic causal modeling of cortical prediction and attention to sounds that weren’t. J. Neurosci. 36, 8305–8316 (2016). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.SanMiguel I., Widmann A., Bendixen A., Trujillo-Barreto N., Schröger E., Hearing silences: Human auditory processing relies on preactivation of sound-specific brain activity patterns. J. Neurosci. 33, 8633–8639 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Edlow B. L., Claassen J., Schiff N. D., Greer D. M., Recovery from disorders of consciousness: Mechanisms, prognosis and emerging therapies. Nat. Rev. Neurol. 17, 135–156 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Chen W. G., et al. , The emerging science of interoception: Sensing, integrating, interpreting, and regulating signals within the self. Trends Neurosci. 44, 3–16 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Berntson G. G., Khalsa S. S., Neural circuits of interoception. Trends Neurosci. 44, 17–28 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Seth A. K., Suzuki K., Critchley H. D., An interoceptive predictive coding model of conscious presence. Front. Psychol. 2, 395 (2012). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.Riganello F., Zubler F., Haenggi M., De Lucia M., Heart rate complexity: An early prognostic marker of patient outcome after cardiac arrest. Clin. Neurophysiol. 134, 27–33 (2022). [DOI] [PubMed] [Google Scholar]
- 48.Dong L., et al. , Reference Electrode Standardization Interpolation Technique (RESIT): A novel interpolation method for scalp EEG. Brain Topogr. 34, 403–414 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Nolan J. P., et al. , European resuscitation council and European society of intensive care medicine 2015 guidelines for post-resuscitation care. Intensive Care Med. 41, 2039–2056 (2015). [DOI] [PubMed] [Google Scholar]
- 50.Nolan J. P., et al. , European resuscitation council and European society of intensive care medicine guidelines 2021: Post-resuscitation care. Intensive Care Med. 47, 369–421 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51.Westhall E., et al. , Standardized EEG interpretation accurately predicts prognosis after cardiac arrest. Neurology 87, 1631 (2016). [DOI] [PubMed] [Google Scholar]
- 52.Booth C. M., Boone R. H., Tomlinson G., Detsky A. S., Is this patient dead, vegetative, or severely neurologically impaired? Assessing outcome for comatose survivors of cardiac arrest. J. Am. Med. Assoc. 291, 870–879 (2004). [DOI] [PubMed] [Google Scholar]
- 53.Delorme A., Makeig S., EEGLAB: An open source toolbox for analysis of single-trial EEG dynamics including independent component analysis. J. Neurosci. Methods 134, 9–21 (2004). [DOI] [PubMed] [Google Scholar]
- 54.Oostenveld R., Fries P., Maris E., Schoffelen J. M., FieldTrip: Open source software for advanced analysis of MEG, EEG, and invasive electrophysiological data. Comput. Intell. Neurosci. 2011, 1568 (2011). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Maris E., Oostenveld R., Nonparametric statistical testing of EEG- and MEG-data. J. Neurosci. Methods 164, 177–190 (2007). [DOI] [PubMed] [Google Scholar]
- 56.Pernet C. R., Wilcox R., Rousselet G. A., Robust correlation analyses: False positive and power validation using a new open source matlab toolbox. Front. Psychol. 3, 606 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 57.Pelentritou A., et al. , Cardiac signals inform auditory regularity processing in the absence of consciousness. GitHub. https://github.com/DNC-EEG-platform/CardioAudio_Coma. Deposited 15 April 2025. [DOI] [PMC free article] [PubMed]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Appendix 01 (PDF)
Data Availability Statement
Custom-made code used in data analyses have been deposited in GitHub (https://github.com/DNC-EEG-platform/CardioAudio_Coma) (57). The data included in this study are not publicly available due to the sensitive nature of the clinical data under ethical regulations but can be available from the corresponding author on reasonable request.




