Skip to main content
. 2025 May 27;17(2):146–152. doi: 10.4274/jcrpe.galenos.2024.2024-7-28

Table 2. The comparison of electrocardiographic findings in the T1DM and control group.

Electrocardiographic measurements (ms) (mean±SD)

T1DM (n=165)

Control group (n=154)

p*

Heart rate (/min)

92±16

89±17

0.675

QT maximum

361.27±33.60

351.38±30.2

0.006

QT minimum

306.66±28.39

312.16±22.7

0.058

QTd

54.017±16.74

39.22±19.40

<0.001

QTc maximum

410.44±20.45

386.82±22.18

<0.001

QTc minimum

382.96±19.98

375.60±20.87

0.011

QTc-d

27.50±9.61

11.21±7.75

<0.001

Tp-e maximum

68.11±9.52

61.27±9.02

<0.001

Tp-e minimum

46.39±8.33

42.63±9.27

0.017

Tpe-d

23.91±7.32

14.89±5.32

<0.001

Tp-e/QTc-maximum

0.19±0.03

0.16±0.03

<0.001

*Student’s t-test.

Tp-e: T-peak-to-end, Tpe-d: Tp-e dispersion, QTc: corrected QT interval, QT-d: QT interval-dispersion, T1DM: type 1 diabetes mellitus