Table 4.
The Results of the Two-Stage Model Selection and Multivariate Linear Mixed Model Analysis With 50 Preoperative Parameters Including 12 Corvis ST Parameters
| Variable | Coefficient | Standard Error | P Value |
|---|---|---|---|
| Blood examination scores | |||
| WBC (µL) | Not selected | ||
| Hb (g/dL) | 0.47 | 0.17 | 0.0072 |
| Cre (mg/dL) | −3.11 | 1.61 | 0.057 |
| BS (mg/dL) | Not selected | ||
| CRP (mg/dL) | 3.15 | 1.25 | 0.014 |
| Ocular parameters | |||
| Preoperative GAT-IOP (mm Hg) | Not selected | ||
| Preoperative use of anti-glaucoma eyedrops | |||
| Brimonidine tartrate, for yes | 1.16 | 0.58 | 0.048 |
| Corvis ST parameters | |||
| bIOP (mm Hg) | 0.28 | 0.12 | 0.024 |
| Peak distance (mm) | 0.52 | 2.50 | 0.83 |
| HCDefAmp (mm) | 6.72 | 8.32 | 0.42 |
| DA ratio max 1 mm | 8.52 | 10.12 | 0.40 |
| DA ratio max 2 mm | −1.14 | 1.04 | 0.28 |
| SPA1 (mm Hg/mm) | Not selected | ||
| SSI | 5.51 | 1.73 | 0.0019 |
| WEM-t (ms) | −0.73 | 0.34 | 0.036 |
P values in bold suggest <0.05.