Skip to main content
. 2025 Apr 26;8:100235. doi: 10.1016/j.crtox.2025.100235

Table 4.

The BMD recommendations modeling hepatic endpoints for Osweiler et al. (1993) and Jennings et al. (2020).

BMDS Recommendations and Notes
Study FUM dataset Endpoint Response means Response variability Exponential 3 Exponential 5 Hill Linear Power
Osweiler et al. (1993) 5, 31, and 148 AST 70.5, 79.5, 392.3* 2.1, 10.1, 136.7* Unusable Questionable Questionable Questionable Questionable
Did not successfully execute. Zero degrees of freedom; saturated model Zero degrees of freedom; saturated model Nonconstant variance test failed (Test 3p-value < 0.05) Zero degrees of freedom; saturated model
Nonconstant variance test failed (Test 3p-value < 0.05) Nonconstant variance test failed (Test 3p-value < 0.05) Goodness of fit p-value < 0.1 Nonconstant variance test failed (Test 3p-value < 0.05)
Control stdev. fit > 1.5 Control stdev. fit > 1.5 Control stdev. fit > 1.5 Control stdev. fit > 1.5
Osweiler et al. (1993) 5, 31, and 148 GGT 17.5, 20.5, 84.3* 1.71, 3.67, 14.45* Recommended: lowest AIC Questionable Questionable Questionable Questionable
BMD − 18.2 Zero degrees of freedom; saturated model Zero degrees of freedom; saturated model Zero degrees of freedom; saturated model Goodness of fit p-value < 0.1
BMDL − 8.2
BMDU − 41.3
Osweiler et al. (1993) 5, 31, and 148 LDH 952.8, 970.7, 1811.1* 55.9, 51.3, 255.8* Recommended: lowest AIC Questionable Questionable Questionable Questionable
BMD − 64.3 Zero degrees of freedom; saturated model Zero degrees of freedom; saturated model Zero degrees of freedom; saturated model Goodness of fit p-value < 0.2
BMDL − 34.7
BMDU − 134.5
Jennings et al. (2020) 5.0, 26.7, 40.7, SA:SO 0.07, 0.08, 0.2, 0.01, 0.05, 0.12, Questionable Questionable Unusable Unusable Unusable
67.7, and 108.8 0.3, and 0.8* 0.08, and 0.45* Control stdev. fit > 1.5 Lowest dose/BMDL ratio > 3 Control stdev. fit > 1.5 Lowest dose/BMD ratio > 3 Control stdev. fit > 1.5
Constant variance test failed (Test 2p-value < 0.05) Lowest dose/BMDL ratio > 10 Constant variance test failed (Test 2p-value < 0.05) Lowest dose/BMD ratio > 10 Constant variance test failed (Test 2p-value < 0.05)
Control stdev. fit > 1.5 BMDL does not exist Goodness of fit p-value < 0.1 BMDL does not exist
Constant variance test failed (Test 2p-value < 0.05) Control stdev. fit > 1.5
BMD/BMDL ratio > 3 Constant variance test failed (Test 2p-value < 0.05)
BMD/BMDL ratio > 20 BMDL does not exist

*Reported to differ from corresponding control.