Univariable Linear Regression Models Exploring Factors Associated with Interocular Difference (Right Eye Minus Left Eye) in Average RNFL Thickness

Interocular Difference in Average RNFL Thickness (µm)
Predictor Univariable
Interval/Reference β 95% CI P Value
Age 1 year older −0.04 −0.13 to 0.04 0.32
Gender (female) Male −0.03 −1.19 to 1.13 0.96
Race (black) White 0.64 −1.89 to 3.17 0.62
Ethnicity (Hispanic or Latino) Not Hispanic or Latino 0.36 −2.80 to 3.52 0.82
Interocular difference in average CDR 1-unit increase −7.36 −13.1 to −1.62 0.01
Interocular difference in vertical CDR 1-unit increase −7.07 −12.43 to −1.71 0.01
Interocular difference in cup volume 1-mm3 increase −6.55 −13.9 to 0.81 0.08
Interocular difference in disc area 1-mm2 increase 1.26 −1.31 to 3.82 0.34
Interocular difference in rim area 1-mm2 increase 7.59 4.00 to 11.18 <.001
Interocular difference in axial length 1-mm increase −1.53 −2.97 to −0.09 0.04
Interocular difference in signal strength 1-unit increase 1.30 0.72 to 1.88 <.001

Interocular differences in all OCT parameters were calculated by subtracting left eye values from the right eye.