Abstract

Background:

Traumatic lower limb injuries can result in chronic pain. Orthotic interventions are a leading conservative approach to reduce pain, manage loading, and protect the foot. Robust carbon fiber custom dynamic orthoses (CDOs) designed for military service members have been shown to reduce foot loading. However, the effect of carbon fiber orthosis design, including designs widely used in the civilian sector, on foot loading is unknown.

Research Question:

Determine if carbon fiber orthoses alter foot loading during gait.

Methods:

Loadsol insoles were used to measure peak forces and force impulse acting on the forefoot, midfoot, hindfoot, and total foot. Nine healthy, able-bodied individuals participated. Force impulse was quantified as cumulative loading throughout stance phase. Participants walked without an orthosis and with three carbon fiber orthoses of differing designs: a Firm stiffness CDO, a Moderate stiffness CDO, and a medial and lateral strut orthosis (MLSO).

Results:

There were significant main effects of orthosis condition on peak forefoot forces as well as forefoot and hindfoot force impulse. Peak forefoot forces were significantly lower in the Moderate and Firm CDOs compared to no orthosis and MLSO. Compared to walking without an orthosis, forefoot force impulse was significantly lower and hindfoot force impulse was significantly greater in all carbon fiber orthoses. Additionally, hindfoot force impulse in the Firm CDO was significantly higher than in the MLSO and Moderate CDO.

Significance:

The three carbon fiber orthosis designs differed regarding foot loading, with more robust orthoses providing greater forefoot offloading. Orthosis-related changes in forefoot loading suggest that carbon fiber orthoses could reduce loading-associated pain during gait. However, increased hindfoot force impulse suggests caution should be used when considering carbon fiber orthoses for individuals at risk of skin breakdown with repetitive loading.

Keywords: Gait, Plantar Loading, Ankle Foot Orthosis

1. BACKGROUND

Traumatic lower limb injuries can result in poor long term physical outcomes, disability, and long term chronic pain.1–7 Pain with weight bearing and/or joint motion can stem from structural damage and impact different regions of the foot8 and foot pain can lead to mobility limitations and compensatory gait strategies.9 Chronic pain following traumatic injury can also lead to delayed amputation.4, 5 The forefoot is a commonly affected region of particular concern for individuals with conditions including traumatic lower extremity injuries.1, 9 Heel pain, which can impact daily function and gait, is often exacerbated with limb loading.7, 9, 10 Foot pain can be addressed in multiple ways, such as through offloading the painful region by transferring forces to another region.9 Orthotic interventions offer one option for managing peak forces and repetitive loading. Orthoses are used to reduce pain, manage loading, and protect the plantar surface of the foot.11–17

Ankle foot orthoses (AFOs) stiffen the limb, provide support, control motion, and have been shown to reduce pain in multiple patient populations.18, 19 Carbon fiber custom dynamic orthoses (CDOs) are a family of AFOs used to improve function for military service members following traumatic lower extremity injuries. CDOs are increasingly provided to civilians with a range of lower extremity conditions.19–23 CDOs consist of a proximal cuff that wraps around the leg just below the knee, a posterior carbon fiber strut that bends to store and return energy during gait, and a carbon fiber footplate that protects the foot and acts as a lever arm to deform the posterior strut. CDOs are commonly used in patients with lower limb trauma and weakness to augment weak or missing plantarflexors.24 As the posterior strut deforms during stance, energy is stored in early-to-mid stance and is returned in late stance to assist with push-off and help compensate for weak plantarflexors.19, 23 In addition to compensating for plantarflexor weakness, multiple studies have shown that CDOs also transfer forces away from the foot to the lower leg.19, 23 The ability to transfer forces from the foot to the lower leg may benefit patients who experience pain with foot loading following traumatic lower limb injury.

The Intrepid Dynamic Exoskeletal Orthosis (IDEO), a large, stiff, and highly customized CDO developed for military service members who experienced limb trauma,23 was shown to reduce forefoot loading by more than 60% and hindfoot loading by more than 10%, in a cohort of 42 military service members. Similarly, a civilian version of the IDEO, the ExoSym (Hanger Inc.) was shown to reduce forefoot loading by more than 65% in a group of six civilians with arthritic foot or ankle conditions secondary to injury.19 Despite this reduction, hindfoot loading was not significantly altered.19 Because these studies evaluated CDOs with very similar designs, that are generally stiffer and more restrictive than those used in civilian practice, applying these findings to civilian clinical practice has limitations. Previous studies evaluating the effect of AFOs and semi-rigid braces on foot loading during gait in other patient populations have yielded varied effects on forefoot and hindfoot loading and suggest design is an important consideration.25–27

Many carbon fiber orthoses available for use with civilian patients are lighter weight and use a lower profile design than military CDOs. The effect of these design differences on foot loading are not well understood. An improved understanding of how carbon fiber orthosis design affects foot loading can be used to inform efforts to reduce foot loading and pain in individuals who have experienced injury or could otherwise benefit from reduced foot loading. The purpose of this study was to determine the effects of three commercially available carbon fiber orthoses, with differing strut designs and stiffnesses, on foot loading during gait.

2. METHODS

Study activities were reviewed and approved by the local institutional review board, and all participants provided written informed consent prior to participating. Nine (4 Female/5 Male, 21.8 (1.7) years, 1.7 (0.1) m, 74.0 (13.2) kg) participants provided informed written consent and took part in this study. Participants were included if they were between the ages of 18 and 50, had a shoe size between women’s 8 and 13.5 or men’s 6.5 and 12 (United States shoe size), had full bilateral active range of motion of the lower extremities and spine, could hop and perform a full squat without pain, and were healthy without complaint of lower extremity pain, spinal pain, or medical or neuromusculoskeletal disorders that limited participation in work or exercise in the last 6 months. Participants were excluded if they had been diagnosed with a moderate or severe brain injury, had prior lower extremity injury that resulted in surgery or limited function for greater than 6 weeks, had been diagnosed with a physical or psychological condition that would preclude testing, had visual or hearing impairments that would interfere with instructions given during testing, required an assistive device, had wounds to the foot or calf that would prevent CDO use, had a body mass index (BMI) greater than 35 kg/m2, or were pregnant.

Loadsol wireless insoles (100 Hz, Novel Electronics, St. Paul, MN, USA) were used to measure forces acting on the plantar surface of the foot as participants walked at a controlled speed based on leg length.28 The Loadsol insoles provide reliable assessment of forces acting on the plantar surface of the foot during gait.29, 30 Participants first walked without an orthosis (NoCDO) and then with the three carbon fiber orthoses (Figure 1) in a randomized order. The carbon fiber orthoses included two CDOs with posterior struts of differing stiffness (FirmCDO and ModCDO; Bio-Mechanical Composites, Des Moines, IA) and a low-profile carbon fiber orthosis with two medial/lateral carbon fiber struts (MLSO; Bio-Mechanical Composites, Des Moines, IA) with generic footplate geometries. The FirmCDO and ModCDO both consist of a proximal cuff, posterior carbon fiber strut, and a full-length flexible carbon fiber footplate. The MLSO consists of two carbon fiber struts and a partial length carbon fiber footplate that extends to the metatarsal heads. The carbon fiber struts of the MLSO are located on the medial and lateral aspects of the lower leg, with the medial strut posterior to the medial malleolus and the lateral strut anterior to the lateral malleolus. The correct size orthosis was chosen to best fit each participant and the properly sized Loadsol insole size was selected for each participant based on the fit of the insole inside of the participant’s shoes and the orthosis footplate.31 In the NoCDO condition, the Loadsol insoles were placed between the participant’s feet and shoes. In the carbon fiber orthosis conditions, the Loadsol insoles were placed between the participant’s foot and shoe on the uninvolved limb and between the foot and carbon fiber orthosis footplate on the involved limb.

Figure 1:

Figure 1:

Participants completed testing without an orthosis (NoCDO) and while wearing three carbon fiber orthoses: A) a CDO with a firm stiffness posterior strut – FirmCDO, B) a CDO with a moderate stiffness posterior strut – ModCDO, and C) a low-profile carbon fiber orthosis with two medial/lateral struts – MLSO.

Data were processed using Visual 3D software (C-motion Inc., Germantown, MD) and MATLAB R2022 (The MathWorks Inc., Natick, MA). Peak forces (N/kg) and force impulse (Ns/kg) normalized to participant body weight were calculated for the forefoot (distal 40% of insole), midfoot (middle 30% of insole), hindfoot (proximal 30% of insole), and total foot (100% of insole). Force impulse was calculated using the indefinite integral over the stance phase of gait for all three regions of the foot and the combined total foot.

Shapiro Wilk tests for normality were run for peak force and force impulse data for all conditions and regions of the foot. A one-way repeated measures analysis of variance (ANOVA) was used to determine main effects of condition for peak force and force impulse data. Significant main effects (p<0.05) were further analyzed with post-hoc paired sample t-tests using a Bonferroni Holm correction. Statistical analysis was completed using SPSS v29 (IBM, New York, NY).

3. RESULTS

Timeseries data for the force, normalized to body weight, acting on each region of the foot and the total foot from 0–100% of the gait cycle can be found in Figure 2. Ensemble mean values for peak forces and force impulse for each region of the foot and the total foot are presented in Table 1 and Table 2 respectively.

Figure 2:

Figure 2:

Mean forces acting on the forefoot, midfoot, hindfoot, and total foot from 0–100% of the gait cycle, normalized to body weight. For each condition, mean forces acting on each region of the foot were calculated using data from all participants.

Table 1:

Force impulse normalized to body weight, mean (SD), was calculated for each condition and each region of the foot using data from all participants. Statistically significant differences following Bonferroni Holm corrections have been identified.

NoCDO FirmCDO ModCDO MLSO
Forefoot Force Impulse (Ns/kg) 2.7 (0.5) 1.8 (0.6)* 2.2 (0.5)* 2.0 (0.6)*
Midfoot Force Impulse (Ns/kg) 0.9 (0.3) 1.1 (0.4) 1.2 (0.4) 1.2 (0.3)
Hindfoot Force Impulse (Ns/kg) 1.9 (0.4) 2.9 (0.9)* 2.3 (0.5)*^ 2.5 (0.8)*^
Total Foot Force Impulse (Ns/kg) 5.6 (0.5) 5.8 (0.4) 5.6 (0.5) 5.8 (0.5)

Significantly different from

*

NoCDO

^

FirmCDO conditions

Table 2:

Peak force normalized to body weight, mean (SD), for each condition and each region of the foot were calculated using data from all study participants. Statistically significant differences following Bonferroni Holm corrections have been identified.

NoCDO FirmCDO ModCDO MLSO
Hindfoot Max (N/kg) 8.3 (0.5) 8.3 (1.6) 8.3 (1.4) 8.0 (0.5)
Midfoot Max (N/kg) 2.9 (1.0) 2.7 (1.0) 2.9 (0.8) 3.0 (0.8)
Forefoot Max (N/kg) 10.1 (0.8) 7.6 (1.6)*+ 7.9 (1.4)*+ 9.4 (1.0)
Total Max Early (N/kg) 10.8 (0.7) 10.7 (1.0) 10.8 (1.2) 10.6 (0.6)
Total Max Late (N/kg) 10.6 (0.7) 11.2 (1.1) 11.2 (1.1) 10.8 (0.8)

Significantly different from

*

NoCDO

+

MLSO conditions

A significant main effect of orthosis condition was observed for forefoot (p=0.003) and hindfoot (p=0.003) force impulse. No significant main effects were found for midfoot or total foot force impulse. Post-hoc testing, using paired sample t-tests with Bonferroni Holm corrections, indicated that hindfoot force impulse significantly increased when walking in all carbon fiber orthosis conditions (FirmCDO: p=0.001, ModCDO: p<0.001, MLSO: p=0.003) relative to walking without an orthosis (NoCDO). Further, hindfoot force impulse increased significantly less in ModCDO (p=0.004) and MLSO (p=0.008) conditions than in the FirmCDO. Post-hoc testing also indicated that forefoot force impulse was significantly reduced for all orthosis conditions (FirmCDO: p<0.001, ModCDO: p=0.005, MLSO: p=0.001) relative to walking without an orthosis (NoCDO).

There was a significant main effect of condition on peak forefoot force (p = 0.016). No significant main effects were observed for peak midfoot, hindfoot, or total foot forces. Post-hoc testing, indicated a significant reduction in peak forefoot forces while walking in the ModCDO (p=0.016) and FirmCDO (p=0.011) conditions compared to walking without an orthosis (NoCDO). Further, the FirmCDO (p=0.006) and the ModCDO (p=0.013) conditions reduced peak forefoot forces significantly more than the MLSO.

4. DISCUSSION

Reducing foot loading has potential benefits for individuals with foot and ankle pathology, including reducing pain and lowering the risk of ulceration.32, 33 Carbon fiber orthoses are one option to manage foot loading during gait,19–23, 27 but the effects of ankle foot orthoses and orthosis design on limb loading are not well understood. This study measured forces acting on the hindfoot, midfoot, forefoot, and total foot while participants walked without an orthosis and while wearing three carbon fiber orthoses of different strut stiffnesses and designs.

During gait, forces acting on the foot progress from the hindfoot to the forefoot.9, 34 Orthoses provide external support to the ankle joint through resisting rotation and augmenting or replacing forces required by the ankle plantar flexors, reducing forward progression of the center of pressure (CoP).19, 23 Even if total loading under the foot is not altered, as seen in this study, the forces under the foot may be redistributed. All three carbon fiber orthoses in this study increased the hindfoot force impulse relative to walking without an orthosis, primarily due to greater loading from 30 to 55% of the gait cycle (Figure 2). This finding is consistent with previous studies showing a redistribution of forces under the foot with orthoses that cross the ankle,19, 23, 26, 27 as compared to normal gait. The hindfoot force impulse with the FirmCDO was significantly higher than for the other two carbon fiber orthoses and over 50% greater than NoCDO. Given that there were no significant changes in total foot force impulse, the greater hindfoot force impulse was counterbalanced by the largest decrease in forefoot force impulse with the FirmCDO. While forefoot force impulse with the FirmCDO was >30% lower than NoCDO, it was not significantly different than the other carbon fiber orthoses. These results suggest that, within the range of orthoses assessed in this study, design has a greater effect on cumulative loading of the hindfoot than of the forefoot. It may be unexpected that the reductions in forefoot force impulse with the MLSO, which had the lowest strut height, and lever arm, were not significantly different than the CDOs.

Redistribution of loading from the forefoot to the hindfoot while walking with the carbon fiber orthoses altered the trajectory of the mean forefoot force curve over stance. In normal gait, forefoot forces rapidly rise from 20–50% of the gait cycle, peaking during push-off after the heel has risen off of the ground.35 In this study, the mean forefoot forces with the carbon fiber orthosis diverged from the NoCDO condition, rising more gradually between 30–55% of the gait cycle, resulting in decreased peak forefoot forces. While all carbon fiber orthoses had lower mean peak forefoot forces, only the ModCDO and FirmCDO were significantly decreased when compared to walking in NoCDO. Additionally, the ModCDO and FirmCDO, which utilize a full-length carbon fiber footplate and posterior strut which runs the length of the lower limb, were shown to have significantly lower peak forefoot forces compared to the MLSO which uses a shorter footplate and strut design.

Previous work investigating the effects of CDOs on foot loading have used robust, very stiff CDOs.19, 23 These CDOs have also been shown to redistribute loading from the forefoot to the hindfoot as evidenced by shorter CoP progression, altered force impulse, and decreased peak loading.19, 27 Hindfoot force impulse increased by more than 65% and forefoot force impulse decrease more than 50% with the robust CDOs.19 Moreover, peak forefoot forces were shown to decrease by more than 60%.19, 23 The smaller reduction in forces observed in this study may stem from a number of factors, such as CDO design differences. The IDEO and similar CDOs include a rigid proximal cuff, stiff posterior strut, and a rigid, highly customized footplate. While the ModCDO and FirmCDO in this study have a carbon fiber keel that runs from the top of the cuff to the end of the toes, the padded cuff, strut, and foot plate are designed to be more compliant. More compliant devices can allow greater ankle motion during gait24, 36 and allow forces to progress further under the forefoot during gait. Greater flexibility of the footplate may also reduce the transfer of forces from under the foot to the posterior strut and proximal cuff. Further, the orthoses in this study were not customized to the individual, potentially allowing greater motion of the limb and limiting force redistribution. These design differences potentially explain why the ModCDO and FirmCDO reduced forefoot force impulse (18–33%) and peak forefoot forces (21–24%) are less than the highly robust CDOs previously studied. Similarly, the MLSO has multiple design differences compared to the CDOs, including the lack of a proximal cuff, shorter carbon fiber struts running along the medial and lateral sides of the leg, and a short footplate. While the MLSO was shown to influence hindfoot and forefoot force impulse, it had no significant effect on peak forefoot forces. This result indicates that orthosis design may play a larger role on peak loading than cumulative loading.

Pain with foot loading is common and can be affected by injury or pathology type, as well as patient characteristics.1, 8–10, 37 Personalized intervention requires an understanding of the effects of the orthosis being provided. Orthoses are intended to provide external support to the ankle joint and resist rotation of the ankle, thereby reducing forward progression of the CoP.19, 23 This is seen with each of the carbon fiber orthoses included in this study, as forces were redistributed across the foot, forefoot force impulse and peak forefoot forces decreased and hindfoot force impulse increased. Individuals who experience pain with forefoot loading may benefit from the reductions in peak forefoot forces provided by a CDO with a full-length carbon fiber footplate and posterior strut that runs the length of the leg. Reductions in forefoot force impulse may also benefit individuals with forefoot pain. However, the increased hindfoot force indicates that caution should be used when considering carbon fiber orthoses as a treatment option for individuals who are at risk of skin breakdown with prolonged loading.

While the results of this study provide important insight into the effects of clinically available carbon fiber orthoses on foot loading, limitations include the use of a modest cohort of healthy, able-bodied individuals. While the study of individuals without pathology limits direct application to specific patients or patient populations, it provides valuable insight into the general effects of carbon fiber orthosis design on offloading. These findings can be used to inform future device and patient population selection for subsequent studies, with the appreciation that the findings are independent of potentially confounding factors such as changes in gait or the effect of deformities in patients. For example, the increased hindfoot force impulse observed in this study emphasizes the importance of conducting skin checks in future studies with patient populations to verify participant skin health. To best represent the offloading associated with individual types of foot and ankle pathology, future work should include the study of promising device designs in individuals who experience foot and ankle pain during gait.

Acknowledgements

This work was supported by the Assistant Secretary of Defense for Health Affairs endorsed by the Department of Defense, through the Peer Reviewed Medical Research Program under Award No. W81XWH-17 and by the National Center for Advancing Translational Sciences of the National Institutes of Health under Award Number UM1TR004403. Opinions, interpretations, conclusions, and recommendations are those of the authors and are not necessarily endorsed by the Department of Defense or National Institutes of Health. The generic sized CDOs included in this study were purchased from the manufacturer and the low-profile carbon fiber orthoses with two medial/lateral carbon fiber struts were donated.

Footnotes

CRediT Authorship Contribution Statement

Kirsten Anderson: Data curation, formal analysis, investigation, methodology, project administration, visualization, writing – original draft, writing – review & editing. Molly Corlett: Conceptualization, data curation, investigation, methodology, visualization. Sara Magdziarz: Data curation, investigation, methodology, visualization, writing – review & editing. Donald Anderson: Conceptualization, funding acquisition, methodology, resources, software, supervision, validation, writing – review & editing. Jason Wilken: Conceptualization, funding acquisition, methodology, resources, software, supervision, validation, writing – original draft, writing – review & editing.

Conflict of Interest Statement

The authors have no conflicts of interest to disclose.

Data Availability

The data findings from this study are available from the corresponding author upon reasonable request.

References

  • 1.Castillo RC, MacKenzie EJ, Wegener ST, et al. Prevalence of chronic pain seven years following limb threatening lower extremity trauma. Pain 2006; 124: 321–329. DOI: 10.1016/j.pain.2006.04.020. [DOI] [PubMed] [Google Scholar]
  • 2.MacKenzie EJ and Bosse MJ. Factors influencing outcome following limb-threatening lower limb trauma: lessons learned from the Lower Extremity Assessment Project (LEAP). J Am Acad Orthop Surg 2006; 14: S205–210. DOI: 10.5435/00124635-200600001-00044. [DOI] [PubMed] [Google Scholar]
  • 3.Doukas WC, Hayda RA, Frisch HM, et al. The Military Extremity Trauma Amputation/Limb Salvage (METALS) study: outcomes of amputation versus limb salvage following major lower-extremity trauma. J Bone Joint Surg Am 2013; 95: 138–145. DOI: 10.2106/jbjs.K.00734. [DOI] [PubMed] [Google Scholar]
  • 4.Ramasamy A, Hill AM, Phillip R, et al. The modern “deck-slap” injury--calcaneal blast fractures from vehicle explosions. J Trauma 2011; 71: 1694–1698. DOI: 10.1097/TA.0b013e318227a999. [DOI] [PubMed] [Google Scholar]
  • 5.Ramasamy A, Hill AM, Masouros S, et al. Outcomes of IED foot and ankle blast injuries. J Bone Joint Surg Am 2013; 95: e25. DOI: 10.2106/jbjs.K.01666. [DOI] [PubMed] [Google Scholar]
  • 6.McLaughlin KH, Mitchell SL, Archer KR, et al. Effect of Severe Distal Tibia, Ankle, and Mid- to Hindfoot Trauma on Meeting Physical Activity Guidelines 18 Months After Injury. Archives of Physical Medicine and Rehabilitation 2022; 103: 409–417.e402. DOI: 10.1016/j.apmr.2021.07.805. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Bosse MJ, Teague D, Reider L, et al. Outcomes After Severe Distal Tibia, Ankle, and/or Foot Trauma: Comparison of Limb Salvage Versus Transtibial Amputation (OUTLET). Journal of Orthopaedic Trauma 2017; 31. [DOI] [PubMed] [Google Scholar]
  • 8.Chung CL, Paquette MR and DiAngelo DJ. Impact of a dynamic ankle orthosis on acute pain and function in patients with mechanical foot and ankle pain. Clin Biomech (Bristol, Avon) 2021; 83: 105281. 2021/02/20. DOI: 10.1016/j.clinbiomech.2021.105281. [DOI] [PubMed] [Google Scholar]
  • 9.Riskowski JL, Hagedorn TJ, Dufour AB, et al. Associations of Region-Specific Foot Pain and Foot Biomechanics: The Framingham Foot Study. The Journals of Gerontology: Series A 2015; 70: 1281–1288. DOI: 10.1093/gerona/glv067. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Wearing SC, Smeathers JE, Yates B, et al. Bulk compressive properties of the heel fat pad during walking: A pilot investigation in plantar heel pain. Clinical Biomechanics 2009; 24: 397–402. DOI: 10.1016/j.clinbiomech.2009.01.002. [DOI] [PubMed] [Google Scholar]
  • 11.Janisse DJ and Janisse E. Shoe modification and the use of orthoses in the treatment of foot and ankle pathology. J Am Acad Orthop Surg 2008; 16: 152–158. DOI: 10.5435/00124635-200803000-00006. [DOI] [PubMed] [Google Scholar]
  • 12.Kay H Clinical Applications of the Veterans Administration Prosthetics Center PatellarTendon-Bearing Brace Artificial Limbs 1971; 15: 46–67. [PubMed] [Google Scholar]
  • 13.Roy KJ. Force, pressure, and motion measurements in the foot: current concepts. Clin Podiatr Med Surg 1988; 5: 491–508. [PubMed] [Google Scholar]
  • 14.Shaw JE, Hsi WL, Ulbrecht JS, et al. The mechanism of plantar unloading in total contact casts: implications for design and clinical use. Foot Ankle Int 1997; 18: 809–817. DOI: 10.1177/107110079701801210. [DOI] [PubMed] [Google Scholar]
  • 15.Trepman E and Donnelly P. Patellar Tendon-Bearing, Patten-Bottom Caliper Suspension Orthosis in Active Charcot Arthropathy: Crutch-Free Ambulation with No Weight Bearing in the Foot. Foot & Ankle International 2002; 23: 335–339. DOI: 10.1177/107110070202300408. [DOI] [PubMed] [Google Scholar]
  • 16.Varma AK. Charcot neuroarthropathy of the foot and ankle: a review. J Foot Ankle Surg 2013; 52: 740–749. 2013/08/24. DOI: 10.1053/j.jfas.2013.07.001. [DOI] [PubMed] [Google Scholar]
  • 17.Mcllmurray WJ, Greenbaum W. A below-knee weight bearing brace. Orthop Prosth Appl J 1958.; 12: 81–82. [Google Scholar]
  • 18.Choo YJ and Chang MC. Commonly Used Types and Recent Development of Ankle-Foot Orthosis: A Narrative Review. Healthcare 9. DOI: 10.3390/healthcare9081046. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Feng J, Weiss J, Thompson A, et al. Passive Dynamic Ankle Foot Orthoses Use in Civilian Patients with Arthritic Conditions of the Foot and Ankle. Foot & Ankle Orthopaedics 2023; 8: 24730114231157734. DOI: 10.1177/24730114231157734. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Anderson KM, Evans RE, Connerly CE, et al. Custom Dynamic Orthoses and Physical Therapist Intervention for Bilateral Midfoot Amputation: A Case Report. Phys Ther 2021; 101. DOI: 10.1093/ptj/pzab028. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Alimusaj M, Knie I, Wolf S, et al. [Functional impact of carbon fiber springs in ankle-foot orthoses]. Orthopade 2007; 36: 752–756. DOI: 10.1007/s00132-007-1125-0. [DOI] [PubMed] [Google Scholar]
  • 22.Patzkowski JC, Blanck RV, Owens JG, et al. Can an ankle-foot orthosis change hearts and minds? Journal of surgical orthopaedic advances 2011; 20: 8–18. [PubMed] [Google Scholar]
  • 23.Stewart J, Djafar T, Miltenberger R, et al. Plantar Pressure Changes with Use of an Intrepid Dynamic Exoskeletal Orthosis. JPO: Journal of Prosthetics and Orthotics 2020; 32. [Google Scholar]
  • 24.Grunst MM, Wiederien RC and Wilken JM. Carbon fiber ankle-foot orthoses in impaired populations: A systematic review. Prosthetics and Orthotics International 9900. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Alimerzaloo F, Kashani RV, Saeedi H, et al. Patellar tendon bearing brace: combined effect of heel clearance and ankle status on foot plantar pressure. Prosthet Orthot Int 2014; 38: 34–38. . DOI: 10.1177/0309364613486916. [DOI] [PubMed] [Google Scholar]
  • 26.Dickerson LC and Queen RM. Foot Posture and Plantar Loading With Ankle Bracing. Journal of Athletic Training 2021; 56: 461–472. DOI: 10.4085/1062-6050-164-20. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Kearney RS, Lamb SE, Achten J, et al. In-shoe plantar pressures within ankle-foot orthoses: implications for the management of achilles tendon ruptures. Am J Sports Med 2011; 39: 2679–2685. 20110909. DOI: 10.1177/0363546511420809. [DOI] [PubMed] [Google Scholar]
  • 28.Vaughan CL and O’Malley MJ. Froude and the contribution of naval architecture to our understanding of bipedal locomotion. Gait Posture 2005; 21: 350–362. DOI: 10.1016/j.gaitpost.2004.01.011. [DOI] [PubMed] [Google Scholar]
  • 29.Renner KE, Williams DSB and Queen RM. The Reliability and Validity of the Loadsol(®) under Various Walking and Running Conditions. Sensors (Basel) 2019; 19 20190111. DOI: 10.3390/s19020265. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Burns GT, Deneweth Zendler J and Zernicke RF. Validation of a wireless shoe insole for ground reaction force measurement. Journal of Sports Sciences 2019; 37: 1129–1138. DOI: 10.1080/02640414.2018.1545515. [DOI] [PubMed] [Google Scholar]
  • 31.Seiberl W, Jensen E, Merker J, et al. Accuracy and precision of loadsol® insole force-sensors for the quantification of ground reaction force-based biomechanical running parameters. European Journal of Sport Science 2018; 18: 1100–1109. DOI: 10.1080/17461391.2018.1477993. [DOI] [PubMed] [Google Scholar]
  • 32.Carlson JM. Functional Limitations From Pain Caused by Repetitive Loading on the Skin: A Review and Discussion for Practitioners, With New Data for Limiting Friction Loads. JPO: Journal of Prosthetics and Orthotics 2006; 18: 93–103. [Google Scholar]
  • 33.Hulshof CM, van Netten JJ, Pijnappels M, et al. The Role of Foot-Loading Factors and Their Associations with Ulcer Development and Ulcer Healing in People with Diabetes: A Systematic Review. Journal of Clinical Medicine 9. DOI: 10.3390/jcm9113591. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Chiu M-C, Wu H-C and Chang L-Y. Gait speed and gender effects on center of pressure progression during normal walking. Gait & Posture 2013; 37: 43–48. DOI: 10.1016/j.gaitpost.2012.05.030. [DOI] [PubMed] [Google Scholar]
  • 35.Hayafune N, Hayafune Y and Jacob HAC. Pressure and force distribution characteristics under the normal foot during the push-off phase in gait. The Foot 1999; 9: 88–92. DOI: 10.1054/foot.1999.0518. [DOI] [Google Scholar]
  • 36.Harper NG, Esposito ER, Wilken JM, et al. The influence of ankle-foot orthosis stiffness on walking performance in individuals with lower-limb impairments. Clinical Biomechanics 2014; 29: 877–884. DOI: 10.1016/j.clinbiomech.2014.07.005. [DOI] [PubMed] [Google Scholar]
  • 37.Espinosa N, Maceira E and Myerson MS. Current concept review: metatarsalgia. Foot Ankle Int 2008; 29: 871–879. DOI: 10.3113/FAI.2008.0000X. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The data findings from this study are available from the corresponding author upon reasonable request.