TABLE II.
Detection Evaluation. The F-score is calculated with β = 0.5 to reflect the preference for precision over recall.
Noise level | True positive | False positive | False negative | Precision | Recall | F-score |
---|---|---|---|---|---|---|
1× SNR | 667 | 16 | 1333 | 0.98 | 0.33 | 0.70 |
10× SNR | 727 | 15 | 1273 | 0.98 | 0.36 | 0.73 |
100× SNR | 758 | 19 | 1242 | 0.98 | 0.38 | 0.74 |