Abstract
Background
To evaluate the impact of different polishing systems on surface roughness (SR), surface gloss (SG), and vickers microhardness (VMH) of flowable bulk-fill composites reinforced with zirconium oxide fillers.
Methods
Two flowable bulk-fill composites reinforced with zirconium oxide fillers (PALFIQUE BULK FLOW, Filtek Bulk Fill Flowable) and another one with conventional fillers (Tetric N-Flow Bulk Fill) were used. For each tested material, 40 cylindrical specimens (8-mm diameter, 4-mm height) were prepared. Specimens were divided into 4 subgroups according to polishing system used (n = 10/subgroup): subgroup I; Mylar strip (control), subgroup II; 1-step polishing system, subgroup III; 2-step polishing system, and subgroup IV; multi-step polishing system. Surface roughness was evaluated with a 3D noncontact optical profilometer. Gloss was evaluated with a glossmeter. Microhardness was evaluated with a Vickers Microhardness tester. Statistical analysis was performed using two-way ANOVA, Bonferroni, and Pearson correlation coefficient testes (p < 0.05).
Results
For surface roughness, there was no significant difference between groups for control and 1-step (p = 0.152 for control, p = 0.296 for 1-step), while there was a significant difference for 2-step and multi-step (p = 0.025 for 2-step, p = 0.001 for multi-step). For gloss, there was no significant difference between groups for 1-step and 2-step (p = 0.124 for 1-step, p = 0.226 for 2-step), while there was a significant difference for control and multi-step (p = 0.001 for control, p < 0.001 for multi-step). For microhardness, there was no significant difference between groups for control (p = 0.245), while there was a significant difference for the other techniques (p < 0.001 for 1-step and 2-step, p = 0.001 for multi-step).
Conclusions
Reinforcement with zirconium oxide fillers improved flowable bulk-fill composites in terms of surface roughness, gloss, and microhardness. Surface gloss and microhardness were significantly influenced by material type and polishing system used, while surface roughness was influenced only by polishing system used.
Keywords: Composite resins, Dental polishing, Surface properties, Zirconium oxide
Introduction
Dental resin composites are becoming the most popular direct restorative material for both anterior and posterior teeth due to patients’ increasing esthetic demands [1, 2]. Additionally, dental resin composites are now the preferred restorative material in most nations due to the detrimental environmental consequences of dental amalgam [3]. Dental resin composites are primarily composed of a matrix that is responsible for the polymerization reaction, and filler particles that are mixed into the resin matrix to improve the composites’ mechanical and physical characteristics. Fillers also reduce the polymerization shrinkage which is the main shortage of the resin matrix [4]. Several advancements have been made to improve the mechanical and physical characteristics by modifying the matrix and fillers to extend the lifespan and therapeutic use of resin composite materials [5].
Fillers have passed through several phases of development in various aspects until nanotechnology was used [6]. These nanofillers may consist of nanoparticles or nanoaggregates made of high filler load nanoparticles of silica or zirconium/silica [7]. Resin composites’ mechanical and physical characteristics were enhanced, and their polymerization shrinkage was reduced [8].
The dental industry has seen the introduction of novel “bulk-fill” resin composites, which have the ability to polymerize into thicknesses of up to 4 and 5 mm [9, 10]. Different initiators, filler technologies, translucent structures, and alternate organic matrices are the basic characteristics of these resin composites. Therefore, bulk-fill resin composites may present advantages such as time savings and easier clinical applications [11, 12]. Bulk-fill composite resins may reduce shrinkage stress and simplify clinical processes, so they have become more popular [13]. More compact restorations may be created since the bulk-fill placement prevents contamination and gaps from forming between composite layers. Increased light transmittance through bulk-fill resin composite, which is achieved by enhancing its transparency, can result in more successful restorations. Bulk-fill resin composites can be divided into two categories according to consistency: regular viscosity and low viscosity materials [14].
Flowable bulk-fill resin composites (FBRCs) are becoming more and more common because they are simpler to manipulate with than regular viscous formulations and have excellent flow qualities that enable both the penetration of very narrow, deep clefts and the rapid filling of large gaps. The size and quantity of filler determine reduced viscosity and customized flowability; as a result, flowable bulk-fill resin composites are continually provided with less filler, which adversely affects a number of mechanical characteristics, particularly the elastic modulus and wear resistance [15, 16]. Flowable bulk-fill resin composites were believed they need to be capped with a layer of regular or high viscosity resin composite as they had inadequate color stability and low wear resistance [17]. Recently, with more advancement of fillers and resin matrix, FBRCs can be adapted to irregular anterior and posterior cavities and don’t require a capping layer of regular viscosity resin composite. Also, increasing filler load and using spherical nano zirconia and silica fillers provide good polishability and enhance the physical, mechanical, and esthetic properties. Besides that, their flowable nature provides excellent cavity adaptation and more time-saving procedures [18, 19].
Surface characteristics affect the durability and clinical behavior of restorative materials [20]. Rough surfaces make restorations more susceptible to the accumulation of plaque, gingival irritation, discoloration, and recurrent caries, so surface roughness has a significant impact on the esthetics and durability of restorations [21–24]. Similarly, the human eye can detect changes in gloss, so it is essential to ensure matching between the restoration and the surrounding enamel [25]. Microhardness is a crucial surface characteristic that establishes the material’s ability to withstand long-term scratches [26, 27]. Since resin composite with higher microhardness has more wear resistance [28, 29]. The dental resin composite composition and the restoration’s finishing or polishing method affect the surface roughness, gloss, and microhardness [30–32].
Resin composite finishing and polishing (F/P) are crucial procedures during restoration [33, 34]. Despite a properly placed Mylar strip resulting in the cleanest and most polished surface possible, the cured composite surface beneath it is rich in resin and may include voids and defects [35, 36]. Additionally, resin composite restorations require shape correction, flash removal, and modification [37]. The surface is rough after finishing processes and requires further polishing [38, 39]. The endurance and esthetics of resin composite restorations are impacted by finishing and polishing [40, 41]. Achieving desirable anatomy and appropriate occlusion is provided by proper F/P. Additionally, proper F/P lessens SR, scratches, and their effects and provides a smooth, hard, glossy and esthetically stable surface finish [42]. The dental market offers a wide range of F/P techniques and systems with varying compositions and steps. Different types of F/P techniques, such as coated abrasive discs (finishing discs), carbide burs, abrasive stones, diamond burs, abrasive-impregnated rubber wheels and cups, abrasive strips, and polishing pastes, differ in their effects [43–45]. The multi-step systems use a smaller grain polish system at each step to remove scratches in the previous polisher until a high gloss surface is obtained. For single-step systems, abrasive size is important due to the possibility of leaving scratches on the resin composites. Therefore different F/P systems with different steps should be evaluated with different types of resin composites [46].
It was reported that, the hardness of fillers, as long as the different F/P systems were found to have a significant effect on SR, SG and microhardness [47, 48]. Adding radiopaque zirconium oxide (ZrO2) nanofillers, which are harder and have higher wear resistance than conventional fillers, to FBRCs would enhance mechanical properties and help to improve radiographic diagnosis [49–52].
A comprehensive search of the literature revealed that there are no published studies assessing the effects of various finishing and polishing techniques on FBRCs reinforced with ZrO2 fillers and how these procedures affect the surface roughness, gloss, and microhardness of these resin composite materials according to the knowledge of authors. Therefore, more researches were required to expand and strengthen the scientific information regarding this issue. This study was designed to evaluate the impact of different polishing systems on surface roughness, surface gloss, and vickers microhardness of flowable bulk-fill composites reinforced with zirconium oxide fillers. The first null hypothesis tested was that the type of flowable bulk-fill resin composite had no significant effect on surface roughness, surface gloss, and microhardness. The second null hypothesis tested was that finishing and polishing technique had no significant effect on surface roughness, surface gloss, and microhardness of all tested flowable bulk-fill composite. The third null hypothesis tested was that there was no correlation between surface roughness, surface gloss, and microhardness regarding the type of resin composite and the type of finishing and polishing system.
Materials and methods
Materials
In this study, the resin composite materials used were: two commercially available FBRCs reinforced with silica-zirconia fillers; PALFIQUE BULK FLOW (PBF) (Tokuyama Dental, Tokyo, Japan), and Filtek Bulk Fill Flowable (FBF) (3 M ESPE St. Paul, MN, USA), and another FBRC with conventional fillers; Tetric N-Flow Bulk Fill (TBF) (Ivoclar Vivadent AG, Schaan, Liechtenstein). Materials used in this study are shown in Table 1. The F/P systems used in this study were: a 1-step F/P system; OneGloss (Shofu, Japan), a 2-step F/P system; Sof-Lex Spiral (3 M ESPE St. Paul, MN, USA), and a multi-step F/P system; OptiDisc (Kerr, USA). F/P systems and techniques are shown in Table 2.
Table 1.
Materials used in the study
| Material | Composition | Manufacturer | Lot No. |
|---|---|---|---|
| PALFIQUE BULK FLOW |
Matrix: 2-hydroxy propoxy, Bis-GMA, Bis-MPEPP, TEGDMA, Mequinol, Dibutyl hydroxyl toluene, and UV absorber Fillers: Supra-Nano Spherical filler (200 nm spherical SiO2-ZrO2) Filler loading: 70 wt% (56 vol%) |
Tokuyama Dental, Tokyo, Japan | 131E22 |
| Filtek Bulk Fill Flowable |
Matrix: Bis-GMA, TEGDMA, Bis-EMA, and procrylat resins Fillers: ytterbium, trifluoride (size range from 0.1 to 5.0 microns) and SiO2-ZrO2 (size range from 0.01 to 3.5 microns) Fillers loading: 64.5 wt% (42.5 vol%) |
3 M ESPE (St. Paul, MN, USA) |
10,073,908 |
| Tetric N-Flow Bulk Fill |
Matrix: monomethacrylates and dimethacrylates Fillers: barium glass, ytterbium trifluoride and copolymers (ranges between 0.1 μm and 30 μm with a mean particle size of 5 μm) Fillers loading: 68.2 wt% (46.4 vol%) |
Ivoclar Vivadent AG, Schaan, Liechtenstein | Z0417F |
Table 2.
Finishing and Polishing systems used in the study
| Material & Lot No. |
Manufacturer | Procedures | |
|---|---|---|---|
| 1-step |
OneGloss Lot No: 0721327 |
Shofu, Japan | Used for 30 s with a low-speed handpiece for each specimen at a rotation speed 10,000 RPM with intermittent water spray heavy pressure was applied first for finishing then light pressure for polishing. |
| 2-step |
Sof-Lex Spiral Finishing and Polishing Wheels Lot No: N995293 |
3 M ESPE (St. Paul, MN, USA) |
Pre-polishing with rubber spiral coated with aluminium oxide (beige) for 30 s, followed by diamond polishing spiral wheel (pink) for 30 s with a low speed handpiece at 15,000 RPM with intermittent water spray. |
| Multi-step |
OptiDisc Lot No: 9,589,808 |
Kerr, USA | descending sequence of abrasiveness, medium (light brown), fine (orange), and superfine (yellow) with uniform pressure and a planar motion using low speed handpiece at 10,000 RPM for 15–20 s for each disc with intermittent water spray |
Methods
Sample size calculation and study design
The sample size was calculated based on surface roughness results retrieved from a previous study [53]. Based on the effect size of 1.05, a 2-tailed test, α error = 0.05, and power = 90.0%, the sample size was determined to be 9 in each group using the G power software version 3.1.9.7. Therefore, 10 specimens were included in each group. Three groups of specimens were created based on the type of FBRC (n = 40). Each group was divided into four subgroups based on the type of F/P technique used (n = 10/subgroup). Subgroup I: a control group (Mylar strip) where no finishing technique was applied, subgroup II: specimens were finished with 1-step technique, subgroup III: specimens were finished with 2-step technique, and subgroup IV: specimens were finished with multi-step technique. The finishing and polishing procedures were done by the same operator to avoid bias, using a low-speed contra-angle handpiece (Sirona, Dentsply, USA) with water coolant. Specimens were fixed in a base made of dental stone and a spirit level was used to make sure they were parallel to the floor. New discs and polishers were used to polish each specimen. Surface roughness, surface gloss, and Vickers microhardness tests were performed on the same specimens.
Specimens’ preparation
All specimens were prepared using split cylindrical Teflon molds (8-mm diameter and 4-mm height). A Mylar strip was applied over a glass slide, and then the Teflon mold was fixed on them. Composite resin materials were injected into the mold until the mold was slightly overfilled, and then the mold was covered by another Mylar strip and glass slide. The glass slide above the mold was pressed with a constant metal weight (500 g) for 30 s to eliminate any excess material and make the surface flat. A light-emitting diode (LED) curing device (Elipar S10, 3 M ESPE) calibrated at 1,200 mW/cm2 for 20 s was then used to polymerize the specimens. Irradiance of the light curing unit was regularly checked by a radiometer (Bluephase Meter II, Ivoclar Vivadent, Liechtenstein). After the specimens were removed from the mold, each specimen has been marked from its side to distinguish the upper surface from the lower surface. Then all specimens were kept in distilled water at 37 ± 1 °C for 24 h before F/P procedures. F/P systems used and the technique used for each system are presented in Table 2 in details. After polishing the upper surfaces of all specimens, the specimens were kept in distilled water at 37 ± 1 °C for 24 h before evaluating the surface roughness, gloss, and microhardness of the polished surfaces.
Surface roughness evaluation
A 3D noncontact optical profilometer (Model NT 1100, Wyko, Veeco, USA) coupled to a PC running image software (Vision 32, Veeco, USA) was used to measure SR [54, 55]. The program presents the images that gave arithmetic roughness mean (Ra) data based on the peaks and valleys observed in the analyzed region using a profilometer with a 2.4 mm evaluation length and a 0.8 mm cut-off. Consequently, a three-dimensional image of the specimen’s surface was produced. After that, five 3D pictures of each specimen were taken, one in the middle and one on each side [56]. Surface topography of representative specimens from all tested groups is shown in Fig. 1.
Fig. 1.
Surface topography of representative specimens from all tested groups. Specimens were photographed using a USB Digital microscope attached to a built-in camera (Scope Capture Digital Microscope, Guangdong, China) connected to IBM compatible computer at a magnification of 120X with a resolution of 350 × 400 pixels. A 3D image was created using a digital image analysis system WSxM software (Ver 5 develop 4.1, Nanotec, Electronica, SL)
Gloss evaluation
A ZHENTNER glossmeter of type ZGM 1130 (supplied by ZHENTNER testing equipment– Switzerland) was used to measure the gloss of every specimen. A black glass standard has a gloss of 100 gloss units (GU), which considered the perfect gloss and GU of 0 considered nonglossy, was used as a reference [57]. The measurement area was 2 × 2 mm and 60º geometry angel was used to assess each specimen [58, 59]. Each specimen was placed underneath the device base and eventually covered the whole measuring area in the center of the aperture to collect the measurements; each specimen had three measurements, which were then averaged. To avoid any outside light during the measurement process, the measurements were conducted in a completely dark room.
Microhardness evaluation
The specimens’ surface microhardness was measured using the Digital Display VMH Tester (Model HVS-50, Laizhou Huayin Testing Instrument, China) with a 20X objective lens and a diamond Vickers indenter. A 100 g force was applied to the specimens’ surface for 15 s. Each specimen’s surface had three indentations made at least 0.5 mm apart. Following the measurement of the diagonal length of the indentations using an integrated scaled microscope, Vickers values were converted into microhardness values. An equation was then used to calculate the microhardness: HV = 1.854 P/d2, where HV is Vickers hardness in Kgf/mm2, P is the load in Kgf and d is the length of the diagonals in mm.
Statistical analysis
The data were analyzed using SPSS® software version 25 (SPSS Inc., Chicago, IL, USA). Shapiro-Wilk test was used to diagnose the normality of data distribution of all variables. The data were parametric and met the normal distribution. Consequently, descriptive statistics were presented using mean, and standard deviation (SD). Comparisons for surface roughness, surface gloss, and microhardness between groups (Three different FBRCs) and F/P techniques (control, 1-step, 2-step, and multi-step) were made using two-way ANOVA followed by Bonferroni test for multiple comparisons. A correlation between the tested parameters was measured using the Pearson correlation coefficient. p < 0.05 was considered to be significant.
Results
Surface roughness test results
Two-way ANOVA test showed no significant difference in overall surface roughness between FBRCs (p = 0.147). However, there was a significant difference in overall surface roughness between F/P techniques (p < 0.001). Also, the interaction FBRC*F/P technique was significant (p < 0.001).
Comparison of surface roughness between FBRCs for each finishing and polishing technique is presented in Table 3; Fig. 2. For control and 1-step, there was no significant difference in SR among tested FBRCs (p = 0.152 for control, and p = 0.296 for 1-step). For the 2-step and multi-step, there was a significant difference in SR between tested FBRCs (p = 0.025 for 2-step, and p = 0.001 for multi-step). For 2-step, Tetric N-Flow Bulk Fill had the highest SR, PALFIQUE BULK FLOW came in second, and Filtek Bulk Fill Flowable had the lowest SR. For multi-step, Filtek Bulk Fill Flowable had the highest SR, Tetric N-Flow Bulk Fill came in second, and PALFIQUE BULK FLOW had the lowest SR. Multiple (post hoc) comparisons between each tested FBRCs are showed in the same table. For 2-step, and multi-step finishing techniques, there was a significant difference between PALFIQUE BULK FLOW and Filtek Bulk Fill Flowable, as well as between Filtek Bulk Fill Flowable and Tetric N-Flow Bulk Fill. However, PALFIQUE BULK FLOW and Tetric N-Flow Bulk Fill did not differ significantly.
Table 3.
Comparison between surface roughness mean values (SDs) in micrometer (µm) among all tested flowable bulk-fill resin composites and finishing techniques used
| Control | 1-step | 2- step | Multi-step | Two-way ANOVA (p value) | |
|---|---|---|---|---|---|
| PALFIQUE BULK FLOW | 0.16 (0.03) Aa | 0.30 (0.04) Ba | 0.25 (0.03) Ca | 0.21 (0.03) Da | < 0.001* |
| Filtek Bulk Fill Flowable | 0.20 (0.02) Aa | 0.29 (0.04) Ba | 0.22 (0.03) Cb | 0.27 (0.03) Bb | < 0.001* |
| Tetric N-Flow Bulk Fill | 0.19 (0.03) Aa | 0.27 (0.04) Ba | 0.26 (0.04) Ba | 0.23 (0.01) Ca | < 0.001* |
|
Two-way ANOVA (p value) |
0.152 | 0.296 | 0.025* | 0.001* |
A, B Different superscripted capital letters in same row indicate statistically significant differences
a, b Different superscripted lowercase letters in same column indicate statistically significant differences
Fig. 2.
A bar chart showing mean values and SDs of surface roughness (in µm) of all tested flowable bulk-fill resin composites for each finishing and polishing technique
Comparison of surface roughness between types of F/P technique for each tested FBRC is presented in Table 3. For all tested FBRCs, there was a significant difference in SR between F/P techniques (p < 0.001 for all tested FBRCs). For PALFIQUE BULK FLOW and Tetric N-Flow Bulk Fill, the highest SR was observed with 1-step, followed by 2-step, then multi-step, and the lowest SR was noted with the control. For Filtek Bulk Fill Flowable, the highest SR was observed with 1-step, followed by multi-step, then 2-step, and the lowest SR was noted with control. Multiple (post hoc) comparisons between each two F/P techniques are shown in the same table. For all tested FBRCs, there was a significant difference between each two finishing techniques, except between 1-step and multi-step for Filtek Bulk Fill Flowable, and between 1-step and 2-step for Tetric N-Flow Bulk Fill.
Surface gloss test results
Two-way ANOVA test showed that there was a significant difference in overall surface gloss between FBRCs (p < 0.001) and F/P techniques (p < 0.001). Also, the interaction FBRC*F/P technique was significant (p < 0.001).
Comparison of surface gloss between FBRCs for each F/P technique is presented in Table 4; Fig. 3. For 1-step and 2-step, there was no significant difference in SG between tested FBRCs (p = 0.124 for 1-step, and p = 0.226 for 2-step). For control and multi-step, there was a significant difference in SG between FBRCs (p = 0.001 for control and p < 0.001 for multi-step). For control, 1-step, and multi-step, PALFIQUE BULK FLOW produced the highest SG, Tetric N-Flow Bulk Fill came in second, and Filtek Bulk Fill Flowable had the lowest surface gloss. For 2-step, Filtek Bulk Fill Flowable had the greatest SG, PALFIQUE BULK FLOW came next, and Tetric N-Flow Bulk Fill showed the lowest surface gloss. Multiple (post hoc) comparisons between each two FBRCs is presented in the same table. For control and multi-step F/P technique, there was a significant difference between PALFIQUE BULK FLOW and Filtek Bulk Fill Flowable, as well as between PALFIQUE BULK FLOW and Tetric N-Flow Bulk Fill. However, Filtek Bulk Fill Flowable and Tetric N-Flow Bulk Fill did not differ significantly.
Table 4.
Comparison between surface gloss mean values (SDs) in gloss units (GU) among all tested flowable bulk-fill resin composites and finishing techniques used
| Control | 1-step | 2-step | Multi-step | Two-way ANOVA (p value) | |
|---|---|---|---|---|---|
| PALFIQUE BULK FLOW | 70.96 (3.12) Aa | 54.17 (2.88) Ba | 55.21 (3.21)Ba | 62.72 (3.73) Ca | < 0.001* |
| Filtek Bulk Fill Flowable | 60.26 (3.87) Ab | 50.67 (3.92) Ba | 57.63 (5.30) ACa | 56.07 (3.99) Cb | < 0.001* |
| Tetric N-Flow Bulk Fill | 63.13 (4.01) Ab | 52.27 (3.36) Ba | 54.96 (2.44) Ba | 58.84 (4.82) Cb | < 0.001* |
|
Two-way ANOVA (p value) |
0.001* | 0.124 | 0.226 | < 0.001* |
A, B Different superscripted capital letters in same row indicate statistically significant differences
a, b Different superscripted lowercase letters in same column indicate statistically significant differences
Fig. 3.
A bar chart showing mean values and SDs of surface gloss (in GU) of all tested flowable bulk-fill resin composites for each finishing and polishing technique
Comparison of surface gloss between types of F/P technique for each FBRC is presented in Table 4. For all tested FBRCs, there was a significant difference in SG between F/P techniques (p < 0.001 for all groups). For PALFIQUE BULK FLOW and Tetric N-Flow Bulk Fill groups, the highest SG was observed with control, followed by multi-step, then 2-step, and the lowest surface gloss was noted with 1-step. For Filtek Bulk Fill Flowable, the highest SG was observed with control, followed by 2-step, then multi-step, and the lowest SG was noted with 1-step. Multiple (post hoc) comparisons between each two F/P techniques are presented in the same table. For PALFIQUE BULK FLOW and Tetric N-Flow Bulk Fill groups, there was a significant difference between each two F/P techniques except between the 1-step and 2-step. For Filtek Bulk Fill Flowable group, there was a significant difference between each two F/P techniques except between control and 2-step, and between 2-step and multi-step.
Vickers microhardness test results
Two-way ANOVA test showed that there was a significant difference in overall VMH between FBRCs (p < 0.001) and F/P techniques (p < 0.001). However, the interaction FBRC*F/P technique was not significant (p = 0.365).
Comparison of VMH between FBRCs for each F/P technique is presented in Table 5; Fig. 4. For control, there was no significant difference in VMH between FBRCs (p = 0.245). For the other F/P techniques, there was a significant difference in VMH between FBRCs (p < 0.001 for 1-step and 2-step, and p = 0.001 for multi-step). For all F/P techniques, PALFIQUE BULK FLOW had the highest VMH, followed by Filtek Bulk Fill Flowable, while Tetric N-Flow Bulk Fill showed the lowest microhardness. Multiple (post hoc) comparisons between each two FBRCs are showed in the same table. For 1-step, 2-step, and multi-step F/P techniques, there was a significant difference between PALFIQUE BULK FLOW and Tetric N-Flow Bulk Fill, as well as between Filtek Bulk Fill Flowable and Tetric N-Flow Bulk Fill. However, PALFIQUE BULK FLOW and Filtek Bulk Fill Flowable did not differ significantly.
Table 5.
Comparison between microhardness mean values (SDs) in Vickers hardness number (HV) among all tested flowable bulk-fill resin composites and finishing techniques used
| Control | 1-step | 2-step | Multi-step | Two-way ANOVA (p value) | |
|---|---|---|---|---|---|
| PALFIQUE BULK FLOW | 68.34 (0.82) Aa | 70.32 (0.81) Ba | 71.13 (0.89) Ba | 70.74 (1.20) Ba | < 0.001* |
| Filtek Bulk Fill Flowable | 68.00 (0.84) Aa | 69.76 (0.84) Ba | 70.17 (1.25) Ba | 70.72 (0.95) Ba | < 0.001* |
| Tetric N-Flow Bulk Fill | 67.52 (1.84) Aa | 68.40 (1.3) Bb | 69.11 (0.98) Bb | 69.16 (0.93) Bb | 0.005* |
|
Two-way ANOVA (p value) |
0.245 | < 0.001* | < 0.001* | 0.001* |
A, B Different superscripted capital letters in same row indicate statistically significant differences
a, b Different superscripted lowercase letters in same column indicate statistically significant differences
Fig. 4.
A bar chart showing mean values and SDs of Vickers microhardness (in HV) of all tested flowable bulk-fill resin composites for each finishing and polishing technique
Comparison of VMH between types of F/P technique for each FBRC is presented in Table 5. For all tested FBRCs, there was a significant difference in VMH between finishing techniques (p < 0.001 for PALFIQUE BULK FLOW and Filtek Bulk Fill Flowable, and p = 0.005 for Tetric N-Flow Bulk Fill). For Filtek Bulk Fill Flowable and Tetric N-Flow Bulk Fill, the highest VMH was observed with the multi-step, followed by the 2-step, then the 1-step, and the lowest VMH was noted with control. For PALFIQUE BULK FLOW, the highest VMH was observed with the 2-step, followed by the multi-step, then the 1-step, and the lowest VMH was noted with control. Multiple (post hoc) comparisons between each two F/P techniques are presented in the same table. For all FBRCs, there was a significant difference between control and other F/P techniques (1-step, 2-step, and multi-step). However, there was no significant difference between 1-step, 2-step, and multi-step F/P techniques.
Correlation between parameters
Correlation between tested parameters is presented in Table 6; Fig. 5. There was a significant negative correlation between surface roughness and surface gloss (R=-0.597, p < 0.001). There was a significant positive correlation between surface roughness and microhardness (R = 0.307, p < 0.001). There was a significant negative correlation between surface gloss and microhardness (R=-0.385, p < 0.001).
Table 6.
Correlations between all tested parameters
| Correlations | ||||
|---|---|---|---|---|
| Surface roughness | Surface gloss | Microhardness | ||
| Surface roughness | Pearson Correlation | 1 | -0.597** | 0.307** |
| Sig. (2-tailed) | 0.000 | 0.001 | ||
| N | 120 | 120 | 120 | |
| Surface gloss | Pearson Correlation | -0.597** | 1 | -0.385** |
| Sig. (2-tailed) | 0.000 | 0.000 | ||
| N | 120 | 120 | 120 | |
| Microhardness | Pearson Correlation | 0.307** | -0.385** | 1 |
| Sig. (2-tailed) | 0.001 | 0.000 | ||
| N | 120 | 120 | 120 | |
**. Correlation is significant at the 0.01 level (2-tailed)
Fig. 5.
Linear charts showing the correlations between surface roughness, surface gloss and microhardness for all tested flowable bulk-fill resin composites
Discussion
Over the years, the development of resin composite has continuously advanced [5]. Nowadays, fillers used in resin composites typically consist of several components, mainly particulate, silica-based fillers, with alumina, zirconia, or any other metal oxides, either separately or in combination, to achieve acceptable mechanical properties, color, and transparency [7]. Furthermore, it has been established that zirconia significantly strengthens the mechanical characteristics of resin composites [50, 51]. Additionally, manufacturers have introduced FBRCs, which have improved curing, shrinkage, mechanical, and wear qualities [14]. This study assessed the surface roughness, surface gloss, and surface microhardness of FBRCs reinforced with zirconium oxide fillers (PALFIQUE BULK FLOW and Filtek Bulk Fill Flowable) in comparison to another bulk-fill flowable resin composite with conventional fillers (Tetric N-Flow Bulk Fill).
The effectiveness of polishing techniques is based on several variables, including the flexibility of the backing material in which the abrasive particles are embedded, the hardness of the abrasives themselves, the geometry of the polishing tools, and the application method (i.e., pressure, duration, and angle). When polishing composite materials, the particles in the abrasive must be harder than the filler particles in the resin. If not, polishing will only occur by the softer resin matrix being worn away, with the harder fillers left behind as protrusions and producing a rough, uneven surface [45]. Since most studies have shown that discs containing aluminium oxide particles are an effective tool for creating a smooth surface [2, 23], OptiDiscs had been used in the current study. Spiral polishing wheels were chosen for our study because of their design, since they can polish any flat or curved surface, including the occlusal surface of posterior teeth [9, 58]. The polishing systems in this study were chosen depending on the number of application steps: 1-step F/P system (OneGloss), 2-step F/P system (Sof-Lex Spiral), and multi-step F/P system (OptiDisc).
In this study, a single operator handled every attempt to guarantee that the technique and all of processes were standardized. To create a uniform, smooth surface for every specimen, the resin composite material was pressed by a constant metal weight between two thin glass slides that were coated on both sides with Mylar strips. Procedures for F/P were delayed for 24 h in this study. Since some earlier research showed that immediate F/P might result in insufficient maturation and plastic deformation of the resin, due to being prone to heat generation [34, 42]. Nasoohi et al. [36] found that dry finishing and polishing resin composites can increase SR values because the abrasive particles detached from the polishing tool may become lodged in the surface of resin composite. On the other hand, Kaminedi et al. [24] found that the smoothest and highest hardness values in nanohybrid resin composites were obtained with dry finishing and polishing. Despite the debate over whether the approach produces smoother surfaces, the generation of excessive heat that might arise from dry F/P and weaken the matrix/filler connection must be taken into account. In the current study, all finishing and polishing systems were used according to manufacturer’s instructions under intermittent water spray.
The surface’s roughness is one of numerous indicators used to describe how a surface deviates from its ideal condition due to slight imperfections that alter the surface’s smoothness, which is impacted by the materials or the manufacturing process [1, 20]. Because a non-contact digital profilometer microscope can scan a surface using a certain kind of laser and produce a 3D surface map without harming the specimens, it was chosen in this study as a quick and simple assessment tool [54, 60]. Surface roughness above the roughness threshold (Ra = 0.2 μm) simultaneously increases biofilm buildup, and below the threshold value, no further bacterial adherence is detectable [55]. Smooth surfaces increase patient comfort since the tip of the tongue can detect a 0.3 μm difference in SR [37]. In the current study, all F/P systems produce surface roughness less than 0.3 μm. So all three systems used in this study could be accepted clinically.
Gloss, which is measured in GU, is a visual appearance characteristic that includes specular reflection from a surface [58]. Numerous factors influence gloss, such as filler size, filler-matrix uniformity, and the refractive index difference between the resin matrix and the fillers [58, 59]. High-gloss resin composite materials blend in better with adjacent teeth than low-gloss ones, and gloss values correlate with resin composite smoothness [59]. Da Costa et al. [57] said that gloss levels between 40 and 50 GU are clinically adequate for resin composites; however previous studies indicated that gloss values between 60 and 70 GU are acceptable [9, 29, 58].
Microhardness is a feature of resin composite that affects its endurance and is linked to its wear resistance [31]. By using the right polishing techniques to remove the outer layer, restoration surfaces with high hardness and wear resistance are produced [22]. The amount of applied force divided by the exposed contact area is the way we can measure the microhardness. The Vickers and Knoop tests are the primary methods used to measure it. Their indenters are shaped differently. In contrast to the diamond base in Knoop, the indenter in the Vickers microhardness testing has a square base pyramid form. In this study, surface microhardness was assessed using the Vickers tester. Because the diagonal indentations that were created by the indenter should be sufficiently large to allow for maximum resolution for accurate measurement, a 100 g applied force was used. If the load exceeded this, the indentation could be too big for the screen [39]. Additionally, the measurements may be impacted by cracks in the indentation.
In this study, surface roughness was significantly influenced by the polishing systems but less so by resin composite type. Babina et al. [33] stated that the resin composite type has an insignificant impact on the restoration SR. In contrast, other studies found that SR was significantly impacted by polishing systems, along with the type of resin composite [10, 11]. In this study, the control group, where samples were cured against a Mylar strip, produced the lowest surface roughness values, which agrees with previous studies [21, 32, 35]. A relatively higher level of surface roughness results from the hard filler particles that are abraded away from the resin matrix when the surface of resin composite comes into contact with finishing and polishing techniques [21]. Among F/P systems, the multi-step F/P system resulted in the lowest SR, followed by 2-step and 1-step, respectively. This could be related to the uniform removal of resin matrix and fillers from the surface by polishing systems that use aluminium oxide-impregnated discs, as previous studies found that flexible aluminium oxide discs resulted in minimum surface roughness in resin composite [10, 34, 45]. According to Erturk-Avunduk et al. [21] and Batmaz et al. [41] multi-step polishing technique tend to have better SR than 1-step technique which agrees with our study. In contrast, Korkmaz et al. [38] found that the 1-step polishing technique results in SR comparable to the multi-step polishing system, and that could be because of the different multi-step system used. Among resin composite materials, PBF exhibited the smoothest surface with the multi-step F/P technique. For the 2-step F/P technique, FBF demonstrated the lowest roughness values. This means, ZrO2-containing resin composite exhibited the smoothest surface, which agrees with previous studies found that resin composites reinforced with ZrO2 fillers exhibited lower surface roughness [48, 49].
In the current study, surface gloss showed significant difference with resin composite type and finishing techniques, which agrees with previous studies [2, 35]. Among the materials, PBF exhibited the highest gloss for most F/P techniques, followed by TBF and FBF respectively. This hierarchy slightly varied with the 2-step F/P technique, as FBF achieved the highest gloss. The multi-step polishing system produced the highest gloss values across most groups, followed by the 2-step system and the 1-step system. Pala et al. [29] and Altınışık et al. [32] reported that 1-step polishing technique (OneGloss) resulted in the least gloss among the other polishing techniques. Also Rodrigues-Junior et al. [25] and Nithya et al. [53] reported that multi-step F/P systems produced higher SG than produced by 1-step systems. The control group (Mylar strip) generally exhibited highest SG values for resin composites due to the smooth surface imparted by Mylar strips during specimens preparation, as confirmed by previous studies [26, 35].
The results demonstrated significant differences in microhardness across FBRC types and finishing techniques, and this revealed that both the type of FBRC and finishing technique significantly influenced VMH. Alharbi et al. [44] and Ehrmann et al. [39] agreed with this. Among the tested materials, the resin composites reinforced with ZrO2 fillers exhibited higher VMH compared to resin composites with conventional fillers. PBF exhibited the highest microhardness, TBF exhibited the lowest microhardness, and FBF exhibited intermediate microhardness. Previous studies found that the resin composite with higher filler load resulted in increased microhardness [6, 27]. In this study, this might explain that PBF (70 wt% and 56 vol%) had a higher VMH than TBF (filler load 68.2 wt% and 46.4 vol%) and FBF (filler load 64.5 wt% and 42.5 vol%). Although TBF has higher filler load than FBF, VMH of FBF was higher than VMH of TBF. The presence of ZrO2 fillers in FBF might explain this result. The enhanced microhardness observed in this study with all F/P systems (1-step, 2-step, and multi-step) compared to Mylar strip is supported by many previous studies [21, 36, 39]. The lowest VMH noted with Mylar strip is explained by the high resin concentration of the outer layer, which results from oxygen inhibition beneath the celluloid strip and impairs the layer’s mechanical qualities.
Based on the results of this study, the first null hypothesis, which stated that the type of flowable bulk-fill resin composite had no significant effect on surface roughness, surface gloss, and microhardness was partially rejected. The results demonstrated that the type of FBRC significantly affected surface gloss and microhardness, but it had no significant effect on surface roughness. The results confirmed that the finishing and polishing techniques significantly affected surface roughness, surface gloss, and microhardness for all tested resin composites. Therefore, the second null hypothesis, which stated that the finishing and polishing technique had no significant effect on surface roughness, surface gloss, and microhardness of all tested flowable bulk-fill resin composites, was rejected. In this study, there was a significant correlation between surface roughness, gloss, and microhardness. The analysis showed a significant negative correlation between surface roughness and surface gloss. It can be attributed to smoother surface reflecting light more uniformly, enhancing gloss. A significant positive correlation was found between surface roughness and microhardness, and a significant negative correlation was observed between surface gloss and microhardness. It can be attributed to harder materials are more resistant to F/P procedures. Therefore, the third null hypothesis which stated that there was no correlation between surface roughness, surface gloss, and microhardness regarding the type of resin composite and the type of finishing and polishing system, was rejected.
Several limitations were identified during the study. The specimens were prepared and tested under ideal conditions. These conditions didn’t replicate the dynamic oral environment. Future studies should incorporate simulated oral environments (e.g., thermal cycling, mechanical loading, and pH variations) to assess long-term material behavior. For resin composite materials and finishing systems, only three types of FBRCs were included, and only three F/P systems were studied. So future studies should include more resin composite materials and finishing techniques to increase generalizability.
Conclusions
Within the limitations of this study the following conclusions can be drawn:
It appeared that zirconium oxide fillers improved the flowable bulk-fill resin composites’ surface roughness, surface gloss, and microhardness.
Surface gloss and microhardness were significantly influenced by material type and polishing system used, while surface roughness was influenced only by polishing system used.
OptiDisc system achieved the smoothest and highest gloss surface with PALFIQUE BULK FLOW and Tetric N-Flow Bulk Fill, whereas the Sof-Lex Spiral system achieved the smoothest and highest gloss surface with Filtek Bulk Fill Flowable.
Compared to Mylar strip, all finishing and polishing systems used in this study enhanced the microhardness of all tested flowable bulk-fill resin composites.
Acknowledgements
Not applicable.
Abbreviations
- FBRCs
Flowable bulk-fill resin composites
- F/P
Finishing and polishing
- ZrO2
Zirconium oxide
- PBF
PALFIQUE BULK FLOW
- FBF
Filtek Bulk Fill Flowable
- TBF
Tetric N-Flow Bulk Fill
- SR
Surface roughness
- SG
Surface gloss
- VMH
Vickers microhardness
- LED
Light-emitting diode
- Ra
Arithmetic roughness mean
- GU
Gloss unit
- Bis-GMA
Bisphenol A glycerolate dimethacrylate
- Bis-MPEPP
Bisphenol A polyethoxy dimethacrylate
- TEGDMA
Triethylene glycol dimethacrylate
- UV
Ultraviolet radiation
- Bis-EMA
Ethoxylated bisphenol A glycol dimethacrylate
Author contributions
Amr E. Elnahas: Methodology, Resources, Investigation, Data curation, Funding acquisition, Writing-original draft and confirming final version. Mohamed E. Elawsya: Visualization, Software, Formal analysis, Validation, Writing-reviewing-editing and confirming final version. Abeer E. ElEmbaby: Conceptualization, Supervision, Project administration, Reviewing and confirming final version.
Funding
Open access funding provided by The Science, Technology & Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB). This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Data availability
The data that support the findings of this study are available from the corresponding author upon reasonable request.
Declarations
Ethics approval and consent to participate
The study was submitted to and approved by the Dental Research Ethics Committee under protocol number A0301024CD (Faculty of Dentistry, Mansoura University).
Consent for publication
Not applicable.
Competing interests
The authors declare no competing interests.
Footnotes
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Monterubbianesi R, Tosco V, Orilisi G, et al. Surface evaluations of a nanocomposite after different finishing and Polishing systems for anterior and posterior restorations. Microsc Res Tech. 2021;84(12):2922–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Lopes IAD, Monteiro PJVC, Mendes JJB, et al. The effect of different finishing and Polishing techniques on surface roughness and gloss of two nanocomposites. Saudi Dent J. 2018;30(3):197–207. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Ferracane JL. Resin composite—state of the Art. Dent Mater. 2011;27(1):29–38. [DOI] [PubMed] [Google Scholar]
- 4.German MJ. Developments in resin-based composites. Br Dent J. 2022;232(9):638–43. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Pfeifer CS. Polymer-based direct filling materials. Dent Clin North Am. 2017;61(4):733–50. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Erdemir U, Sancakli HS, Yildiz E. The effect of one-step and multi-step Polishing systems on the surface roughness and microhardness of novel resin composites. Eur J Dent. 2012;6(2):198–205. [PMC free article] [PubMed] [Google Scholar]
- 7.Habib E, Wang R, Wang Y, et al. Inorganic fillers for dental resin composites: present and future. ACS Biomater Sci Eng. 2016;2(1):1–11. [DOI] [PubMed] [Google Scholar]
- 8.Randolph LD, Palin WM, Leloup G, Leprince JG. Filler characteristics of modern dental resin composites and their influence on physico-mechanical properties. Dent Mater. 2016;32(12):1586–99. [DOI] [PubMed] [Google Scholar]
- 9.Elgammal YA, Temirek MM, Hassanein OE, Abdelaziz MM. The effect of different finishing and Polishing systems on surface properties of new flowable Bulk-fill resin composite. J Contemp Dent Pract. 2023;24(8):587–94. [DOI] [PubMed] [Google Scholar]
- 10.Ishii R, Takamizawa T, Tsujimoto A, et al. Effects of finishing and Polishing methods on the surface roughness and surface free energy of Bulk-fill resin composites. Oper Dent. 2020;45(2):E91–104. [DOI] [PubMed] [Google Scholar]
- 11.Freitas F, Pinheiro de Melo T, Delgado AH, et al. Varying the Polishing protocol influences the color stability and surface roughness of Bulk-Fill Resin-Based composites. J Funct Biomater. 2020;12(1):1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Jakupović S, Pervan N, Mešić E, et al. Assessment of microhardness of conventional and Bulk-Fill resin composites using different Light-Curing intensity. Polym (Basel). 2023;15(10):2250. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Karakaş SN, Batmaz SG, Çiftçi V, Küden C. Experimental study of Polishing systems on surface roughness and color stability of novel bulk-fill composite resins. BMC Oral Health. 2025;25(1):74. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Lassila L, Säilynoja E, Prinssi R, et al. Characterization of a new fiber-reinforced flowable composite. Odontology. 2019;107(3):342–52. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Ömeroğlu MK, Hekimoğlu HC. Evaluation of colour stability, water sorption and solubility of no-cap flowable bulk fill resin composites. BMC Oral Health. 2025;25(1):604. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Ilie N, Högg C. Kinetic of light transmission during setting and aging of modern flowable Bulk-Fill composites. Mater (Basel). 2024;17(17):4292. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Tomaszewska IM, Kearns JO, Ilie N, Fleming GJ. Bulk fill restoratives: to cap or not to cap–that is the question? J Dent. 2015;43(3):309–16. [DOI] [PubMed] [Google Scholar]
- 18.Alshehri A, Alhalabi F, Robaian A, et al. No-cap flowable bulk-fill composite: physico-mechanical assessment. Polym (Basel). 2023;15(8):1847. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Hada YS, Panwar S. Comparison of the fracture resistance of three different recent composite systems in large class II mesio-occlusal distal cavities: an: in vitro: study. J Conserv Dent Endod. 2019;22(3):287–91. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Jang J, Kim H, Shin S, et al. Clinical effectiveness of different Polishing systems and Self-Etch adhesives in class V composite resin restorations: Two-Year randomized controlled clinical trial. Oper Dent. 2017;42(1):19–29. [DOI] [PubMed] [Google Scholar]
- 21.Chowdhury D, Mukherjee S, Maity I, Mazumdar P. Surface roughness and microhardness evaluation of composite resin restorations subjected to three different Polishing systems immediately and after 24 h: an in vitro study. J Conserv Dent Endod. 2023;26(6):639–45. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Chinelatti MA, Chimello DT, Ramos RP, Palma-Dibb RG. Evaluation of the surface hardness of composite resins before and after Polishing at different times. J Appl Oral Sci. 2006;14(3):188–92. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Aydın N, Topçu F-T, Karaoğlanoğlu S, et al. Effect of finishing and Polishing systems on the surface roughness and color change of composite resins. J Clin Exp Dent. 2021;13(5):E446–54. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Kaminedi RR, Penumatsa NV, Priya T, Baroudi K. The influence of finishing/polishing time and cooling system on surface roughness and microhardness of two different types of composite resin restorations. J Int Soc Prev Community Dent. 2014;4(Suppl 2):S99–104. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Rodrigues-Junior S, Chemin P, Piaia P, Ferracane J. Surface roughness and gloss of actual composites as polished with different Polishing systems. Oper Dent. 2015;40(4):418–29. [DOI] [PubMed] [Google Scholar]
- 26.Yazici AR, Tuncer D, Antonson S, et al. Effects of delayed finishing/polishing on surface roughness, hardness and gloss of tooth-coloured restorative materials. Eur J Dent. 2010;4(1):50–6. [PMC free article] [PubMed] [Google Scholar]
- 27.Korkmaz Y, Ozel E, Attar N, Aksoy G. The influence of one-step Polishing systems on the surface roughness and microhardness of nanocomposites. Oper Dent. 2008;33(1):44–50. [DOI] [PubMed] [Google Scholar]
- 28.Elawsya ME, Montaser MA, El-Wassefy N, Zaghloul NM. Depth of cure of dual-and light-cure bulk-fill resin composites. Am J Dent. 2022;35(4):185–90. [PubMed] [Google Scholar]
- 29.Pala K, Tekce N, Tuncer S, et al. Evaluation of the surface hardness, roughness, gloss and color of composites after different finishing/polishing treatments and thermocycling using a multitechnique approach. Dent Mater J. 2016;35(2):278–89. [DOI] [PubMed] [Google Scholar]
- 30.Tchorz J, Doll R, Wolkewitz M, et al. Microhardness of composite materials with different organic phases in deep class II cavities: an in vitro study. Oper Dent. 2011;36(5):502–11. [DOI] [PubMed] [Google Scholar]
- 31.Alfawaz Y. Impact of Polishing systems on the surface roughness and microhardness of nanocomposites. J Contemp Dent Pract. 2017;18(8):647–51. [DOI] [PubMed] [Google Scholar]
- 32.Altınışık H, Özyurt E. Effect of different Polishing systems on surface roughness and gloss values of single-shade resin composites. BMC Oral Health. 2024;24(1):1391. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Babina K, Polyakova M, Sokhova I, et al. The effect of finishing and Polishing sequences on the surface roughness of three different nanocomposites and composite/enamel and composite/cementum interfaces. Nanomaterials (Basel). 2020;10(7):1339. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Venturini D, Cenci MS, Demarco FF, et al. Effect of Polishing techniques and time on surface roughness, hardness and microleakage of resin composite restorations. Oper Dent. 2006;31(1):11–7. [DOI] [PubMed] [Google Scholar]
- 35.Soliman HA, Elkholany NR, Hamama HH, et al. Effect of different Polishing systems on the surface roughness and gloss of novel nanohybrid resin composites. Eur J Dent. 2021;15(2):259–65. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Nasoohi N, Hoorizad M, Tabatabaei SF. Effects of wet and dry finishing and Polishing on surface roughness and microhardness of composite resins. J Dent. 2017;14(2):69–75. [PMC free article] [PubMed] [Google Scholar]
- 37.Magdy NM, Kola MZ, Alqahtani HH, et al. Evaluation of surface roughness of different direct Resin-based composites. J Int Soc Prev Community Dent. 2017;7(3):104–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Aktu A, Ulusoy N. Effect of Polishing systems on the surface roughness and color stability of aged and stained Bulk-Fill resin composites. Mater (Basel). 2024;17(14):3576. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Ehrmann E, Medioni E, Brulat-Bouchard N. Finishing and Polishing effects of multiblade Burs on the surface texture of 5 resin composites: microhardness and roughness testing. Restor Dent Endod. 2019;44(1):E1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Jefferies SR. Abrasive finishing and Polishing in restorative dentistry: a state-of-the-art review. Dent Clin North Am. 2007;51(2):379–97. [DOI] [PubMed] [Google Scholar]
- 41.Batmaz SG, Karakaş SN, Küden C. Surface characteristics and bacterial adhesion on single-shade composite resins: A comparative in vitro study of one-step versus multi-step Polishing techniques. Dent Mater J. 2024;43(6):850–60. [DOI] [PubMed] [Google Scholar]
- 42.Endo T, Finger WJ, Kanehira M, et al. Surface texture and roughness of polished nanofill and nanohybrid resin composites. Dent Mater J. 2010;29(2):213–23. [DOI] [PubMed] [Google Scholar]
- 43.Khairy NM, Elkholany NR, Elembaby AE. Evaluation of surface microhardness and gingival marginal adaptation of three different bulk-fill flowable resin composites: A comparative study. J Esthet Restor Dent. 2024;36(6):920–9. [DOI] [PubMed] [Google Scholar]
- 44.Alharbi G, Al Nahedh HN, Al-Saud LM, et al. Effect of different finishing and Polishing systems on surface properties of universal single shade resin-based composites. BMC Oral Health. 2024;24(1):197. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Kılıç V, Gök A. Effect of different Polishing systems on the surface roughness of various bulk-fill and nano‐filled resin‐based composites: an atomic force microscopy and scanning electron microscopy study. Microsc Res Tech. 2021;84(9):2058–67. [DOI] [PubMed] [Google Scholar]
- 46.Ozdemir B, Ilday NO, Ozdemir S, et al. The effect of erosive beverages and Polishing systems on the surface properties of nanohybrid composite resin. Niger J Clin Pract. 2022;25(3):248–54. [DOI] [PubMed] [Google Scholar]
- 47.Barakah HM, Taher NM. Effect of Polishing systems on stain susceptibility and surface roughness of nanocomposite resin material. J Prosthet Dent. 2014;112(3):625–31. [DOI] [PubMed] [Google Scholar]
- 48.Zhang L, Yu P, Wang X-Y. Surface roughness and gloss of polished nanofilled and nanohybrid resin composites. J Dent Sci. 2021;16(4):1198–203. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Ruivo MA, Pacheco RR, Sebold M, Giannini M. Surface roughness and filler particles characterization of resin-based composites. Microsc Res Tech. 2019;82(10):1756–67. [DOI] [PubMed] [Google Scholar]
- 50.Guo G, Fan Y, Zhang J-F, et al. Novel dental composites reinforced with zirconia–silica ceramic nanofibers. Dent Mater. 2012;28(4):360–8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51.Alhavaz A, Rezaei Dastjerdi M, Ghasemi A, et al. Effect of untreated zirconium oxide nanofiller on the flexural strength and surface hardness of autopolymerized interim fixed restoration resins. J Esthet Restor Dent. 2017;29(4):264–9. [DOI] [PubMed] [Google Scholar]
- 52.Elmarsafy SM. A comprehensive narrative review of nanomaterial applications in restorative dentistry: reinforcement and therapeutic applications (Part II). Cureus. 2025;17(3):e80127. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Nithya K, Sridevi K, Keerthi V, Ravishankar P. Evaluation of surface roughness, hardness, and gloss of composites after three different finishing and Polishing techniques: an in vitro study. Cureus. 2020;12(2):E7037. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54.Amasyalı M, Sabuncuoğlu FA, Ersahan Ş, Oktay EA. Comparison of the effects of various methods used to remove adhesive from tooth surfaces on surface roughness and temperature changes in the pulp chamber. Turk J Orthod. 2019;32(3):132–8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Hao Y, Huang X, Zhou X, et al. Influence of dental prosthesis and restorative materials interface on oral biofilms. Int J Mol Sci. 2018;19(10):3157. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56.Ebaya MM, Ali AI, El-Haliem HA, Mahmoud SH. Color stability and surface roughness of ormocer-versus methacrylate-based single shade composite in anterior restoration. BMC Oral Health. 2022;22(1):430. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 57.da Costa JB, Ferracane JL, Amaya-Pajares S, Pfefferkorn F. Visually acceptable gloss threshold for resin composite and Polishing systems. J Am Dent Assoc. 2021;152(5):385–92. [DOI] [PubMed] [Google Scholar]
- 58.Paolone G, Moratti E, Goracci C, et al. Effect of finishing systems on surface roughness and gloss of Full-Body Bulk-Fill resin composites. Mater (Basel). 2020;13(24):5657. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 59.Sang EJ, Song J-S, Chung SH, et al. Influence of a new Polishing system on changes in gloss and surface roughness of resin composites after Polishing and brushing. Dent Mater J. 2021;40(3):727–35. [DOI] [PubMed] [Google Scholar]
- 60.Alkhuzaie AI, Elawsya ME, Elkholany NR. Impact of different bleaching methods on surface roughness, microhardness, and Tooth-Restoration interface of Ormocer-and Methacrylate-based restorative systems. J Clin Exp Dent. 2025;17(4):e422–31. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The data that support the findings of this study are available from the corresponding author upon reasonable request.





