Enhancing preanalytic surgical specimen management: experience of a system implementation initiative

Peirong Chen 1,✉, Weiming Qiu 2
PMCID: PMC12315191  PMID: 40745621

Abstract

Background /Objectives

Preanalytic quality control of surgical specimens is often inadequately managed. This study aimed to share the experience of improving quality through the implementation of a system for preanalytic surgical specimens.

Methods

After initial workflow mapping and process optimization, a pathology specimen transfer system was piloted and subsequently implemented hospital-wide. Ongoing monitoring and adjustments were made based on established standards and operational needs. Data were analyzed using R Studio software.

Results

The system reduced errors from 24.82 to 2.40%, including reductions of 86.85% in requisition mistakes, 95.30% in label errors, and 100% in illegible handwriting. From 2020 to 2023, the interval between specimen removal and submission was halved, and delayed fixation decreased from 0.46 to 0.22%.

Conclusions

The system effectively standardized processes, enhanced efficiency, and reduced errors in preanalytic surgical specimens. Quality improvement was dependent on thorough workflow mapping and optimization, as well as ongoing monitoring and adjustments.

Keywords: Preanalytic, Surgical specimen, Quality control, Workflow mapping

Introduction

The pathology workflow consists of three primary phases: the preanalytic phase (from the operating room to the pathology laboratory), the analytic phase (from specimen receipt to analysis), and the postanalytic phase (reporting of results) [1]. During the preanalytic phase, surgical specimens are transferred across multiple providers and disciplines, heightening the risk of errors. Common preanalytic errors include wrong requisition forms or specimen label, patient identification issues, inappropriate containers or fixatives, and delays in specimen transport [2]. Poor-quality specimens may lead to misdiagnosis, inappropriate therapies, and emotional harm to patients [3]. It is estimated that defects occur in 6% of operative cases, contributing to as many as 160,000 adverse events annually in the United States [4].

The quality of surgical specimens is often beyond the direct control of pathology laboratories, necessitating close collaboration with clinical departments. Traditionally, specimen management has relied on manual processes, with limited oversight of pre-laboratory specimen turnaround times. This manual approach presents several challenges, including unclear communication, lack of traceability, and difficulty in assigning responsibility when errors occur [5]. Therefore, an integrated system with standardized checks is essential to minimize errors.

In 2020, in conjunction with the implementation of Level 5 Electronic Medical Records (EMR)—a national classification used to evaluate the information system capabilities of healthcare institutions—we introduced a Pathology Specimen Transfer System (PSTS) for surgical specimens. According to Level 5 EMR standards, surgical specimens must follow the same management protocols as blood samples. These standards specifically require the tracking and sharing of information related to specimen collection, transportation, and handover between the laboratory and clinical departments [6]. This paper outlines our experience in optimizing the workflow and implementing the system to enhance surgical specimen quality and reduce preanalytic errors.

Methods

In 2020, our hospital generated a total of 32,092 pathology reports, including 487 frozen sections, 21,131 histopathology reports, and 10,473 cytopathology reports. To support the system implementation, a multidisciplinary team was established, led by the Quality Control Department. The team consisted of a hospital administrator with over 10 years of experience in quality control and patient safety, responsible for project coordination and oversight. Clinical participants included one head nurse and two registered nurses from the operating room, each with more than 15 years of clinical experience, as well as one resident surgeon, one attending surgeon, and two pathologists, all of whom contributed to planning meetings and discussions regarding practical implementation. Additionally, one health informatics specialist and one systems engineer provided essential technical support throughout the project.

The Quality Control Department conducted a preliminary investigation within the surgical departments and operating rooms to map the workflow (see Fig. 1). As shown, the traditional process involved manually recording information on specimen bags, requisition forms, and registration documents, which led to repeated data entry and multiple cross-checks. Additionally, specimens were often not fixed until after surgery. This manual process resulted in several issues, including: (1) incomplete or illegible information on requisition forms, (2) specimens with unclear, contaminated, or missing labels, (3) missing or incorrect registration information, (4) delayed fixation, and (5) an untraceable transfer process, making it difficult to identify the root cause when specimens were lost or mixed.

Fig. 1.

Fig. 1

Surgical specimen workflow before implementing system

After analyzing the original process and identifying existing issues, several discussions were held to develop a new workflow (see Fig. 2). The updated process required personnel to adhere to standardized procedures for order entry, requisition, specimen collection, removal, fixation, verification, submission, and reception [7]. In two joint meetings, the decision was made to eliminate paper-based requisitions and registrations. To address the issue of delayed fixation, pre-filled specimen bottles with fixative were procured, allowing for immediate fixation of minor specimens during surgery. Additionally, to prevent specimens from being retained overnight in the operating room, the delivery schedule was revised to twice daily (8 am and 4 pm).

Fig. 2.

Fig. 2

Surgical specimen workflow after implementing system

These improvements resulted in significant advancements: (1) Paperless Requisitions: The PSTS automatically retrieves patient information, diagnosis, and medical history previously entered by the surgeon in the Electronic Medical Record (EMR) system. The surgeon pre-enters the specimen type and name, and during surgery, the circulator updates or adds specimen details. After surgery, the surgeon supplements the intraoperative findings. The finalized requisition, which includes all of the above details, is transmitted to the Pathology Reporting System (PRS), allowing pathologists to access it throughout the analytic and postanalytic phases. (2) Barcode Labeling: During surgery, the circulator verifies specimen details with the surgeon and prints the specimen label. Each specimen is assigned a unique identifier and QR code. For multiple specimens from the same patient, the system assigns consecutive numbers. (3) Real-time Tracking: The system standardizes the entire process by requiring barcode scanning at each stage—collection, removal, fixation, verification, submission, and reception. Each step is recorded with operator details and timestamps. (4) Automated Registration: During specimen counting, the system displays all collected but unprocessed specimens, with reminders for multiple specimens from the same patient. Specimen data is generated in real-time, eliminating the need for repeated manual registration. (5) Interconnectivity and Interoperability: Pathologists can reject non-compliant specimens online, specifying reasons (e.g., insufficient size, inadequate solution, inappropriate container, mismatched information). Responsible personnel receive notifications and document corrective actions. Regulators can query historical data for review and quality improvement. Additionally, the system enables the clinical team to track specimen status and receive intraoperative diagnostic reports in real time.

The pilot of the PSTS began in the Gynecology Department in mid-October 2020 and was officially rolled out to all surgical departments by the end of December. The Quality Control Department provided training and on-site support to address any issues during the implementation. As the system expanded beyond the central operating room, adjustments were made to accommodate the specific needs of each department. In July 2021, the system was extended to the Digestive Endoscopy Department. Given the importance of endoscopic findings for pathology diagnoses, the PSTS was configured to retrieve these findings and diagnoses from the endoscopy reporting system. Subsequently, the system was introduced to the Dermatology, Outpatient Surgery, and Respiratory Endoscopy Departments in August and September 2021, and March 2022, respectively. In June 2022, gynecological outpatient clinic specimens were also integrated into the system. For liquid-based specimens collected by a single doctor, the process was streamlined by eliminating the two-person check at specimen removal, bypassing the fixation and verification steps. This simplification was tailored to better accommodate the high-paced outpatient setting.

We compared specimen compliance rates before and after implementation and analyzed changes in turnaround time over the years. All statistical analyses were conducted using R Studio software. R is a free programming language that provides a wide range of packages for data analysis. The chi-square test and analysis of variance (ANOVA) were used to compare results. A p-value of less than 0.05 was considered statistically significant.

Results

Comparison of surgical specimen compliance rate

The Quality Control Department conducted monthly spot checks on surgical specimens. Samples selected from May 2020 to December 2021 were categorized into two periods: pre-implementation (May 2020 to December 2020) and post-implementation (January 2021 to December 2021). Chi-square test results (see Table 1) indicate that errors related to illegible information were eliminated, and errors in requisition forms and labels decreased significantly (P < 0.05). After system implementation, only one mislabeled specimen was reported, attributed to a printing error. However, the rate of non-compliant specimens increased slightly from 0.36 to 0.72%. Overall, after the system was implemented, the rate of non-compliant specimens significantly decreased from 24.82 to 2.40% (P < 0.05).

Table 1.

Comparison of surgical specimen compliance rates [n (%)]

Items Pre-implementation (n = 274) Post-implementation (n = 416) P
illegible handwriting 23(8.39) 0(0.00) 0.000
errors in requisition form 30(10.95) 6(1.44) 0.000
errors in specimen label 14(5.11) 1(0.24) 0.000
handling non-compliant specimens * 1(0.36) 3(0.72) 0.546
total 68(24.82) 10(2.40) 0.000

*Note: Before the system implementation, it was unavailable to track fixation time. Therefore, non-compliant specimen handling only included issues such as insufficient fixative and not-dissected specimens recorded by the pathology department

Comparison of surgical specimen time

The system’s accurate recording capabilities enable the direct tracking and review of time limits. Analysis of data from 2020 to 2023 (see Table 2) showed that most specimens were fixed within the required 30-minute window. The interval between specimen removal and submission was reduced by half, from 14.15 h to 6.86 h, while the percentage of non-compliant specimens due to delayed fixation decreased from 0.46 to 0.22% (P < 0.05).

Table 2.

Comparison of surgical specimen time

Items 2020
(n = 431)
2021
(n = 11303)
2022
(n = 42451)
2023
(n = 38982)
P
intervals between specimen removal and fixation (minutes, Inline graphic) 1.155 ± 4.055 2.353 ± 38.59 1.070 ± 19.81 0.543 ± 5.352 0.000
intervals between specimen removal and submission (hours, Inline graphic) 14.15 ± 7.725 9.670 ± 8.086 7.363 ± 7.579 6.868 ± 7.591 0.000
non-compliant specimens exceeding 30-minute fixation limit (n,%) 2(0.46) 48(0.42) 111(0.26) 87(0.22) 0.003*

*Note: The time from removal to fixation and removal to submission were analyzed using variance analysis, while fixation times exceeding 30 min were evaluated using the chi-square test

Discussion

Preanalytic specimen management guidelines, such as those outlined in ISO 15,189 Accreditation, emphasize the need for rigorous evaluation and continuous monitoring of all preanalytic processes [8]. The Practical Guide to Specimen Handling in Surgical Pathology highlights common process deficiencies and provides comprehensive workflow support [9]. Additionally, the Q-Probes program, established by the College of American Pathologists (CAP), offers a peer comparison-based quality assurance framework and sets benchmarks for preanalytic performance [10]. Collectively, these resources form a foundational framework for implementing quality improvement systems in pathology practice.

Numerous studies have shown that the majority of errors in pathology occur during the preanalytic phase. The Initiative for Anatomic Pathology Laboratory Patient Safety (IAPLPS) identified 47 performance metrics for specimen handling, including 9 potential deficiencies specific to the preanalytic stage, 4 of which were classified as high-risk [9]. In one descriptive study, 93% of 648 reported events were traced to errors in the pre-laboratory phase [11]. A multicenter study reported 646 errors among 5,617 specimens (11.5%)2, a rate lower than that observed in our pre-implementation data but significantly higher than our post-implementation results. Requisition form and container errors have been identified as the most common types of preanalytic errors, a finding consistent with our experience [3]. Accurate and complete requisition information is crucial for pathologists to reach correct diagnoses. For example, the omission of pertinent clinical history—such as the presence of a mass lesion or suspicion of liver disease—may alter specimen processing requirements, including the need for deeper tissue sections or special staining [12]. Furthermore, accurate labeling is essential, as mislabeled containers can result in serious adverse outcomes, such as lateralization errors (e.g., right vs. left), potentially leading to incorrect treatment of the organ or limb [13].

Delayed formalin fixation can significantly degrade specimen quality and alter diagnostic results. The Biospecimen Preanalytical Variables program, through controlled and randomized studies, demonstrated that delays in fixation adversely affect DNA and RNA integrity [14]. However, these studies primarily examined fixation delays exceeding one hour, whereas in China, current guidelines recommend that the interval between specimen removal and fixation should not exceed 30 minutes [15]. Notably, one study reported that the expression levels of 5% of genes in lung cancer samples changed by at least two-fold following a 30-minute processing delay [16]. Our findings similarly demonstrated a statistically significant improvement in fixation times following system implementation.

Factors contributing to surgical specimen errors can be broadly categorized into management-related issues (such as incomplete procedures and lack of standardization), environmental influences (including distractions and interruptions), and human factors (such as miscommunication and inadequate handoffs) [3]. The integration of advanced technologies, including barcode scanning and specimen tracking systems, has been shown to standardize workflows and enhance process consistency [2]. In our implementation, the system mandates adherence to prescribed procedures, effectively functioning as both standard operating procedures (SOPs) and work instructions. This structure helps prevent shortcuts and procedural omissions. Real-time tracking further allows personnel to monitor each specimen’s location and status, identify who completed each step, and detect any delays or discrepancies in a timely manner [17].

The system also addresses frequent documentation deficiencies by enforcing required fields and utilizing electronic records. For instance, one study found that missing physician signatures accounted for 50.8% of all preanalytical deficiencies [18]. Direct observation has shown that 1.7% of specimen containers lacked the patient’s name or a secondary identifier, 3.4% were missing the collection date, and 7.3% omitted the physician’s name [13]. These common errors, often resulting from manual data entry, can be entirely prevented by electronic systems. Our data demonstrated that the system reduced requisition form errors by 86.85%, label errors by 95.30%, and eliminated illegible handwriting errors completely. Although barcoding is widely endorsed as a best practice for minimizing specimen identification errors [19] baseline identification error rates were not available for comparison in this study. Nonetheless, the system successfully triggered an alert during a near-miss incident caused by a label printing error, highlighting its effectiveness in early error detection.

Communication failures are the root cause of approximately 52% of surgical incidents [11]. Information-sharing capabilities are critical for overcoming communication barriers, enabling seamless message exchange across systems and facilitating real-time collaboration regardless of physical location. A retrospective review found that intraoperative diagnoses communicated verbally were frequently misinterpreted by surgeons, and that telephone communication increased the risk of perception errors [20]. In our system, finalized reports generated in the PRS are automatically transferred to the PSTS, immediately notifying surgeons and nurses and granting them direct access to diagnostic information. This integration also enhances collaborative management. Previously, the return of non-compliant specimens depended on telephone communication, which often resulted in misunderstandings. The observed increase in specimen non-compliance rates after implementation may reflect the stricter enforcement of standards compared to previous, more lenient manual registration practices. The system’s ability to formally reject non-compliant specimens has made these issues more visible.

However, information technology alone cannot compensate for nonstandard operations. Two incidents of specimen loss occurred, and failure mode analysis revealed that both were linked to consecutive procedural failures. In one case, the circulator, overwhelmed by workload, failed to promptly print specimen labels. Meanwhile, the surgeon presented the specimen to the patient’s family without directly handing it to the nurse, leaving it unattended on the operating table, where it was mistakenly discarded as medical waste. Although the system could cross-reference system data with physical specimens, it could not identify missing specimens if neither the label nor the specimen was available. In response, the operating room revised the Management Regulations for Surgical Patient Specimens, updating the verification process to require the surgeon to confirm each specimen by scanning a code upon placement in the specimen room, thereby establishing joint responsibility for preservation. Additionally, errors related to incomplete or substandard diagnoses, medical histories, and operative findings persisted in 1.44% of requisition forms. To maximize the effectiveness of information technology and reduce errors, strict adherence to standardized operating procedures, regular personnel training, and robust quality control mechanisms are essential [21].

In practice, we employed workflow mapping to diagram the tasks performed by team members across various areas, enabling us to understand complex processes and rapidly identify inefficient or non-value-added activities through visual representation [22]. Redundancies were identified within the manual processes of documenting and cross-checking patient and specimen information. Optimizing these redundant procedures can significantly enhance efficiency, reducing both time and labor costs. Estimates suggest that 10% of traditional processes are wasteful and could be eliminated, while an additional 20% could be substantially improved [23]. Furthermore, successful quality assurance relies on three core principles: continuous quality improvement, a systems approach, and persistent effort [24]. We made targeted adjustments based on departmental needs and conducted regular performance assessments to drive comprehensive quality improvements.

The implementation process required a moderate two-year investment, comprising four weeks of planning, four weeks of staff training and on-site support, and six weeks of pilot testing in a single surgical unit prior to full-scale deployment. No additional financial burden was incurred, as the project utilized internal resources and existing digital infrastructure, including barcode scanners and label printers. Three years after implementation, the system achieved a 90% reduction in documentation errors and a 52% decrease in fixation delays. These improvements, realized with minimal financial investment, suggest that the initiative was both time-efficient and cost-effective, particularly in enhancing preanalytic specimen quality.

This article presents our experience in managing the entire preanalytic process for surgical specimens through the implementation of an information system. Unlike clinical specimens, the preanalytic phase for surgical specimens is often overlooked or undervalued. Moreover, defects in preanalytic surgical specimens remain underexplored, despite being both preventable and identifiable [4]. Few publications have addressed how information technology and management tools can be applied to reform processes and enhance continuous quality control in this domain [25]. As innovations such as automation and artificial intelligence continue to evolve, it is essential for medical institutions to embrace and adapt to these changes to improve diagnostic accuracy and patient outcomes [17]. By utilizing visual tools such as diagrams and symbols, which are assimilated more quickly than text, we mapped the complex workflow, identified inefficiencies, and optimized the process. Through continuous monitoring and iterative adjustments, this approach significantly reduced surgical specimen defects, providing a practical strategy for healthcare systems to implement quality assurance programs.

However, there are limitations to our approach. Initially, surgeons were not directly involved in specimen preservation, despite their critical role in preventing specimen loss. Furthermore, attention must be given to emerging issues, such as the rise in near-miss events and adverse outcomes. Continued research and ongoing quality improvement initiatives are essential to address these challenges and ensure patient safety.

Conclusion

The pathology specimen transfer system for surgical preanalytic specimens standardizes the entire process, reduces repetitive tasks, enhances efficiency, and minimizes errors. Successful implementation requires comprehensive preliminary research to optimize existing workflows, real-time tracking with adaptive adjustments to meet clinical needs, and strict adherence to established quality standards. These components are crucial for ensuring sustained quality improvement.

List of symbols

n

Number

%

Percentage

Inline graphic

Mean ± standard deviation

p

P-value

EMR

Electronic medical record system

PSTS

Pathology specimen transfer system

PRS

Pathology reporting system

Author contributions

P.C: Conceptualization, software, project administration, methodology, formal analysis, investigation, writing original draft preparation, and visualization.W.Q: Supervision, data curation, writing - review & editing.

Funding

Not applicable.

Data availability

No datasets were generated or analysed during the current study.

Declarations

Compliance with ethical standards

Not applicable.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Link T. Guidelines in Practice: Specimen Management, AORN J. 2021;114(5):443–455. 10.1002/aorn.13518 [DOI] [PubMed]
  • 2.Tabatabaee SS, Ghavami V, Kalhor R, Amerzadeh M, Zomorrodi-Niat H. Evaluation of errors related to surgical pathology specimens of different hospital departments with a patient safety approach: a case study in Iran. Patient Saf Surg. 2023;17(1):8. 10.1186/s13037-023-00360-1. [DOI] [PMC free article] [PubMed]
  • 3.Kinlaw TS, Whiteside D. Surgical Specimen Management in the Preanalytic Phase: Perioperative Nursing Implications, AORN Journal. 2019;110(3):237–250. 10.1002/aorn.12782 [DOI] [PubMed]
  • 4.Bixenstine PJ et al. Jul., Developing and Pilot Testing Practical Measures of Preanalytic Surgical Specimen Identification Defects, Am J Med Qual. 2013;28(4):308–314. 10.1177/1062860612469824 [DOI] [PubMed]
  • 5.Holstine JB, Samora JB. Reducing Surgical Specimen Errors Through Multidisciplinary Quality Improvement, The Joint Commission Journal on Quality and Patient Safety. 2021;47(9):563–571. 10.1016/j.jcjq.2021.04.003 [DOI] [PubMed]
  • 6.National Health Commission of the People’s Republic of China. Notice on the issuance of the grading and evaluation management measures for the application level of electronic medical record systems (Trial) and evaluation standards (Trial).2018. https://www.gov.cn/xinwen/2018-12/09/content_5347261.htm
  • 7.Chandra S, Chandra H, Kusum A, Singh Gaur D. Study of the preanalytical phase of an ISO 15189: 2012-Certified cytopathology laboratory: A 5-Year institutional experience. Acta Cytol. 2019;63(1):56–62. 10.1159/000494567. [DOI] [PubMed] [Google Scholar]
  • 8.Schneider F, Maurer C, Friedberg RC. International organization for standardization (ISO) 15189. Ann Lab Med. 2017;37(5):365–70. 10.3343/alm.2017.37.5.365. [DOI] [PMC free article] [PubMed]
  • 9.Banks P, et al. A proposed set of metrics to reduce patient safety risk from within the anatomic pathology laboratory. Lab Med. 2017;48(2):195–201. 10.1093/labmed/lmw068. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Tworek JA, Volmar KE, McCall SJ, Bashleben CP, Howanitz PJ. Q-Probes Studies in Anatomic Pathology: Quality Improvement Through Targeted Benchmarking, Archives of Pathology & Laboratory Medicine. 2014;138(9):1156–1166. 10.5858/arpa.2014-0149-OA [DOI] [PubMed]
  • 11.Steelman VM, Williams TL, Szekendi MK, Halverson AL, Dintzis SM, Pavkovic S. Surgical Specimen Management: A Descriptive Study of 648 Adverse Events and Near Misses, Arch Pathol Lab Med. 2016;140(12):1390–1396. 10.5858/arpa.2016-0021-OA [DOI] [PubMed]
  • 12.Bonert M et al. Aug., Physician and Surgeon Communication Assessed via the Pathology Requisition in a Regional Laboratory Over Ten Years, Cureus. 2022;14(8):e27714. 10.7759/cureus.27714 [DOI] [PMC free article] [PubMed]
  • 13.Layfield LJ, Anderson GM. Specimen Labeling Errors in Surgical Pathology: Table 1: An 18-Month Experience, Am J Clin Pathol. 2010;134(3):466–470. 10.1309/AJCPHLQHJ0S3DFJK [DOI] [PubMed]
  • 14.Carithers LJ et al. Sep., The Biospecimen Preanalytical Variables Program: A Multiassay Comparison of Effects of Delay to Fixation and Fixation Duration on Nucleic Acid Quality, Arch Pathol Lab Med. 2019;143(9):1106–1118. 10.5858/arpa.2018-0172-OA [DOI] [PubMed]
  • 15.Zeng L et al. Jul., Delay in formalin fixation and HER2 testing in gastric cancer, Zhonghua Bing Li Xue Za Zhi. 2014;43(7):468–472. [PubMed]
  • 16.Zhou JH, Sahin AA, Myers JN. Biobanking in genomic medicine. Arch Pathol Lab Med. 2015;139(6):812–8. 10.5858/arpa.2014-0261-RA. [DOI] [PMC free article] [PubMed]
  • 17.Munari E, et al. Cutting-edge technology and automation in the pathology laboratory. Virchows Arch. 2024;484(4):555–66. 10.1007/s00428-023-03637-z. [DOI] [PMC free article] [PubMed]
  • 18.Truong T, et al. Redefining and capturing preanalytic deficiencies in an anatomical pathology laboratory: a quality improvement initiative. Virchows Arch. 2024;484(5):743–51. 10.1007/s00428-023-03611-9. [DOI] [PubMed]
  • 19.Snyder SR, et al. Effectiveness of barcoding for reducing patient specimen and laboratory testing identification errors: A laboratory medicine best practices systematic review and meta-analysis. Clin Biochem. 2012;45:13–4. 10.1016/j.clinbiochem.2012.06.019. [DOI] [PMC free article] [PubMed]
  • 20.Talmon G, Horn A, Wedel W, Miller R, Stefonek A, Rinehart T. How well do we communicate? a comparison of intraoperative diagnoses listed in pathology reports and operative notes, Am J Clin Pathol. 2013;140(5):651–657. 10.1309/AJCP9YUX7DJYMNEE [DOI] [PubMed]
  • 21.Recsky C et al. Feb., Clinical Informatics Team Members’ Perspectives on Health Information Technology Safety After Experiential Learning and Safety Process Development: Qualitative Descriptive Study, JMIR Form Res. 2024;8:e53302. 10.2196/53302 [DOI] [PMC free article] [PubMed]
  • 22.Perrotta P, Novis DA, Nelson S, Blond B, Stankovic A, Talbert M. Workflow Mapping—A Q-Probes Study of Preanalytic Testing Processes: A College of American Pathologists Q-Probes Study of 35 Clinical Laboratories, Archives of Pathology & Laboratory Medicine. 2020;144(12):1517–1524. 10.5858/arpa.2020-0043-CP [DOI] [PMC free article] [PubMed]
  • 23.Tzankov A, Tornillo L. Hands-On experience: accreditation of pathology laboratories according to ISO 15189. Pathobiology. 2017;84(3):121–9. 10.1159/000449254. [DOI] [PubMed] [Google Scholar]
  • 24.Nakhleh RE. Core components of a comprehensive quality assurance program in anatomic pathology. Adv Anat Pathol. 2009;16(6):418–23. 10.1097/PAP.0b013e3181bb6bf7. [DOI] [PubMed]
  • 25.D’Angelo R, Mejabi O. Getting it right for patient safety: specimen collection process improvement from operating room to pathology. Am J Clin Pathol. 2016;146(1):8–17. 10.1093/ajcp/aqw057. [DOI] [PubMed]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

No datasets were generated or analysed during the current study.