Abstract
Background
Rehabilitation of a single missing tooth using a dental implant, although often considered less complex, presents unique clinical challenges and limitations. Central to successful outcomes is a prosthetically driven treatment approach, wherein the final crown position dictates the ideal implant placement within the alveolar bone.
Treatment Considerations
Comprehensive treatment planning requires integrating findings from clinical, radiographic, and diagnostic evaluations to assess site suitability and anatomical constraints. Multiple factors influence implant planning, including soft tissue parameters such as gingival biotype, hard tissue factors like bone quality and quantity, proximity to anatomical structures, and the condition of adjacent and opposing dentition. Importantly, different regions of the oral cavity present distinct priorities: Esthetic demands dominate in the maxillary anterior region, whereas occlusal loads and biomechanical considerations are paramount in posterior sites. Recognizing the regional variability in planning criteria is essential for clinicians to ensure ideal implant positioning, long-term osseointegration, and esthetic success.
Discussion
This review consolidates and organizes key factors that vary by anatomical region, offering a structured framework to support evidence-based decision-making in single-tooth implant rehabilitation. Additionally, we outline the commonly employed surgical protocols, highlighting how clinical and anatomical variables guide the selection of one-stage vs. two-stage placement, immediate vs. delayed loading, and other procedural variations. By emphasizing both universal principles and site-specific considerations, this article aims to serve as a practical guide for clinicians striving for predictable and patient-centered single-tooth implant outcomes.
Keywords: Biomechanical factors, Implant esthetics, Prosthetic-driven approach, Treatment planning, Single-tooth implant
Introduction
The restoration of a missing single tooth presents a unique clinical challenge requiring careful consideration of esthetics, function, and long-term oral health. A single-tooth implant restoration, defined as a dental prosthesis supported by a solitary endosseous implant without involvement of adjacent teeth, has emerged as a highly effective solution for replacing individual missing teeth [1, 2].
A common reason for single-tooth loss is severe decay or apical periodontitis that is unresponsive to root canal treatment, ultimately requiring extraction as part of the treatment plan. However, tooth extraction can have negative consequences, such as (a) bone resorption, (b) shifting of adjacent teeth, and (c) compromised esthetics and chewing function [3]. Other primary causes of tooth loss include periodontal disease leading to mobility, while traumatic injuries can also lead to significant tooth loss.
Unlike traditional prosthetic options such as removable partial dentures (RPDs) and fixed dental bridges, single-tooth implants offer a conservative and biologically sound alternative. Implants restoration preserves the integrity of neighboring teeth and maintains alveolar bone volume, thereby contributing to long-term esthetic and functional stability. Moreover, patient satisfaction with single-tooth implants is consistently reported to be superior compared to alternative treatments, particularly in the anterior esthetic zone, due to their natural appearance and comfort [4].
According to Misch, the rationale for implant use extends beyond function to encompass the psychological and social dimensions of dental health, reinforcing the importance of individualized treatment planning. [5]. Successful outcomes are heavily dependent on proper diagnosis, site evaluation, and a multidisciplinary approach [6]. To ensure a reliable and long-lasting restoration, it is essential to visualize the final restorative outcome before beginning treatment. This approach is referred to as a “prosthetic-driven” treatment [7] (Fig. 1).
Fig. 1.

Workflow for a “prosthetic-driven” treatment planning
The objective of this review is to provide a comprehensive overview of the current principles and considerations in treatment planning for single-tooth implants. It aims to guide clinicians through diagnostic criteria, site assessment, surgical and prosthetic planning, with a focus on evidence-based decision-making and interdisciplinary collaboration.
Pre-Treatment Evaluation
Successful single-tooth implant therapy is contingent upon a thorough and systematic pre-treatment evaluation. This foundational step integrates clinical, radiographic, and diagnostic modalities to assess patient suitability, define anatomical limitations, and design a prosthetically guided plan.
Systemic Factors
Successful single-tooth implant therapy begins with appropriate case selection, with patient-specific factors significantly influencing outcomes. A comprehensive evaluation of systemic health, age, oral hygiene, and patient motivation is imperative prior to treatment initiation.
Systemic health considerations include chronic conditions that may compromise healing and osseointegration. Uncontrolled diabetes mellitus has been linked with delayed wound healing and increased risk of peri-implantitis; however, well-controlled diabetic patients demonstrate comparable implant survival rates to healthy individuals. Smoking, a well-documented risk factor, impairs microcirculation and immune response, reducing implant success and increasing marginal bone loss. Osteoporosis, particularly when treated with bisphosphonates or denosumab, may pose risks of impaired osseointegration and medication-related osteonecrosis of the jaws (MRONJ). While oral bisphosphonates are not an absolute contraindication, detailed risk assessment and informed consent are critical [8–11]. Further, in patients on oral anticoagulants, dental implant surgery can be safely undertaken following local hemostatic measures [12].
Age-related concerns primarily affect the growing patient. Implants are contraindicated in adolescents with incomplete skeletal growth due to the risk of infra-occlusion over time. In older adults, systemic conditions and bone quality must be factored into treatment decisions, although age alone is not a limiting factor [13].
Patient compliance and oral hygiene are equally critical for long-term success. Poor plaque control increases the risk of peri-implant mucositis and peri-implantitis, potentially leading to implant failure. Thorough preoperative education and regular maintenance must be emphasized to optimize outcomes [14].
Clinical Examination
The clinical examination begins with a comprehensive extraoral and intraoral assessment. Facial symmetry, lip line, and smile dynamics are particularly important when planning implants in the esthetic zone. Intraorally, the edentulous ridge is examined for volume, contour, mucosal health, and the width of keratinized tissue. A periodontal evaluation of adjacent teeth is essential, with probing depths, attachment levels, and signs of inflammation all influencing implant prognosis.
Gingival biotype must be classified as thin or thick, as it directly affects esthetic predictability and the likelihood of recession. A thick biotype is more forgiving during surgical and restorative phases, whereas a thin biotype may necessitate soft tissue grafting. The heightened esthetic and functional expectations focus on achieving soft tissue contours that include an intact interdental papilla and a gingival architecture that seamlessly blends with the surrounding natural dentition [15].
Ridge mapping, a technique using bone calipers or stents with anesthesia to measure buccolingual ridge thickness, may be performed when CBCT is unavailable or to supplement findings in borderline cases [6].
Radiographic Assessment
While periapical and panoramic radiographs provide preliminary data on root proximity and periapical health, cone beam computed tomography (CBCT) is now considered essential for precise 3D planning. CBCT enables evaluation of bone density, quantity, and angulation, while identifying anatomical constraints such as the inferior alveolar nerve, maxillary sinus, and nasal floor (Fig. 2).
Fig. 2.

Anatomical landmark considerations as visualized on orthopantomogram. Red line—maxillary sinus floor, blue line—nasal floor, yellow—IAN canal
Dimensional assessment on CBCT confirms whether adequate bone is present. Ideally, 1.5–2 mm of bone should surround the implant on all sides, ensuring long-term osseointegration and esthetic soft tissue contours [16, 17]. CBCT-derived bone density (using Hounsfield units) also guides drilling protocols and implant surface selection—especially in areas of low-density bone.
Additionally, root angulation and proximity to adjacent roots should be evaluated carefully on CBCT. Implants placed too close to adjacent roots (< 1.5 mm) can compromise the periodontal ligament of neighboring teeth or limit papilla preservation. Misaligned roots or apical curvatures may necessitate the use of angled abutments or pre-implant orthodontic correction [16–19] (Table 1) (Fig. 3).
Table 1.
Key dimensional requirements
| Dimension | Recommended minimums | Clinical relevance |
|---|---|---|
| Mesiodistal space | 6–7 mm | Allows for standard diameter implant placement |
| Buccolingual width | ≥ 6 mm | Ensures ≥ 1.5 mm bone around the implant on all sides |
| Interocclusal clearance | ≥ 5–7 mm | Accommodates implant abutment and crown components |
Fig. 3.

Key dimensions for implant planning—≥ 1.5 mm from adjacent tooth; ≥ 3 mm interimplant distance
An essential dimension of implant planning is the “triangle of bone”—a concept that emphasizes placing the implant in a position that maximizes surrounding bone volume and minimizes cortical plate perforation. This triangle is visualized in cross-sectional views from CBCT and is defined by the buccolingual width at the crest as its base and the center of the alveolar ridge as its apex. Ideally, the implant fixture should bisect this triangle to ensure optimal distribution of bone volume around the implant, improve bicortical stabilization, and minimize esthetic and functional complications (Fig. 4).
Fig. 4.
Triangle of bone concept. The implant placement is planned bisecting the ‘triangle of bone,’ thereby optimizing the bone volume covering the implant
Notably, following the natural socket trajectory—especially in immediate placements—can lead to implant misalignment or perforation of the thin buccal plate. The triangle of bone approach corrects for this by aligning the implant with the denser and more voluminous trajectory of the alveolar bone rather than simply following the root socket. This is particularly critical in the maxillary anterior region, where the buccal bone is often thin and angled [19].
Diagnostic Aids
Study models and diagnostic wax-ups are essential tools for visualizing the final prosthetic outcome and facilitating prosthetically guided implant positioning. A rigid vacuum-formed stent can be fabricated over a replica of the diagnostic wax-up to replicate the proposed tooth position and ensure consistent intraoral placement of the surgical guide. These diagnostic aids also help assess interocclusal space, occlusal scheme, and restorative feasibility [18, 20]. When digitized, these models can be integrated into virtual planning workflows.
Digital planning software allows clinicians to virtually place implants in prosthetically ideal positions. This digital workflow enhances surgical accuracy, supports flapless approaches, and enables the design of CAD/CAM surgical guides. These tools are particularly valuable in complex or esthetic cases, where precision is critical [16, 20–22].
Surgical Considerations
The surgical phase of single-tooth implant placement is pivotal in determining the long-term success of the restoration. Surgical precision, anatomical understanding, and prosthetically guided planning must converge to ensure optimal implant positioning, osseointegration, and esthetics. The complexities of implant placement vary significantly across different anatomical regions, particularly between the anterior and posterior zones of the maxilla and mandible.
Maxillary Anterior
The anterior maxilla presents unique challenges due to high esthetic demands and anatomical limitations. Bone quality here is generally moderate (D3) with a thin facial cortical plate [23]. Preserving and augmenting this bone is critical: A minimum of ~ 2 mm of facial bone is recommended to maintain a stable soft tissue profile [20, 24] Adequate ridge dimensions are required for implant site preparation—roughly 6 mm buccolingual width for a standard 3.7–4.0 mm implant (allowing ~ 1 mm of bone on each side) and ~ 7 mm mesiodistal space to ensure ~ 1.5 mm clearance from adjacent tooth roots [20, 25]. If the alveolar width is deficient, horizontal augmentation or guided bone regeneration may be indicated prior to implant placement [26]. Vertical placement depth is equally important: The implant platform is typically placed about 3–4 mm apical to the planned gingival margin to allow a natural emergence profile and papilla formation [26]. Excessively shallow or labial placement can risk exposure of implant metal or dehiscence, especially in sites with thin gingival biotype. Conversely, overly deep placement (> 5 mm apical) can result in a long clinical crown and shadowing at the gingival margin.
Implant placement in the midline anterior maxilla should be planned carefully to avoid encroaching on the nasopalatine canal, which contains neurovascular structures. Accidental involvement may result in excessive bleeding, sensory disturbances, or implant failure. CBCT evaluation is essential for identifying the position and size of the canal to ensure implants are placed either laterally or after careful ridge grafting if needed.
Esthetic and Soft Tissue Considerations
Preservation of the interdental papilla and gingival contour is paramount. The distance from the bone crest to the contact point of the restoration should be limited to ~ 5 mm or less—beyond this, papilla fill drops markedly (e.g., ≥ 6 mm distance yields papilla presence in only ~ 50% of cases). This underscores the need to maintain crestal bone height or perform bone grafting in extraction sites to support papillae [27]. Soft tissue augmentation (connective tissue grafts or papillae regeneration techniques) at stage 2 surgery can further enhance papillary outcomes in high-smile-line cases. Implant diameter selection and positioning should account for the anatomy of each anterior tooth: For example, a maxillary lateral incisor often requires a narrower implant (~ 3.0–3.5 mm) placed slightly more shallow than a central incisor [28] All implants in this zone should be angulated such that the prosthetic screw access emerges at the cingulum, avoiding a labial trajectory [26]. In sum, atraumatic surgical technique with a restorative-driven approach (using surgical guides or wax-ups) is essential to optimize implant positioning in the anterior maxilla [29].
Biomechanical Considerations
Although functional loads on anterior implants are lighter than in posterior regions, off-axis or excessive forces can still jeopardize outcomes. [30]. The crown should be designed to share guidance with adjacent teeth and minimize heavy protrusive or lateral contacts on the implant (Table 2).
Table 2.
Summary of pre-requisites for maxillary anterior implant
| Aspect | Details |
|---|---|
| Bone quality | D3 (moderate density) |
| Anatomical consideration | Nasopalatine foramen |
| Ideal dimensions | ≥ 6 mm BL width, 7 mm MD space, 10 mm vertical height |
| Esthetic priorities | High esthetic zone, papilla and gingival margin crucial |
| Surgical key points | Place implant 3–4 mm apical to gingival margin; avoid labial dehiscence |
| Papilla management | Maintain < 5 mm from bone crest to contact point |
| Common risks | Metal exposure, recession, poor papilla fill |
Maxillary Posterior
In the posterior maxilla, surgical planning centers on managing poorer bone quality and proximity to the sinus. The bone in this region is often of low density (Misch D4), which historically showed higher early failure rates if standard protocols were used [31]. Modern techniques adapt the site preparation to soft bone: Under-preparation of the osteotomy (leaving the final drill size ~ 0.5 mm smaller than the implant diameter) allows the implant threads to compress and engage trabecular bone, improving primary stability in D4 bone [32]. Achieving good initial stability may also involve using tapered implants or those with deeper thread patterns designed for soft bone [33].
Implant placement in this region must account for the floor of the maxillary sinus—a vital anatomical constraint [20]. Sufficient vertical bone (at least ~ 10 mm) should exist to place an implant; if less is available due to sinus pneumatization, a sinus elevation procedure is indicated. For minor vertical deficits (e.g., 6–8 mm crestal bone), an indirect sinus lift with simultaneous implant placement can be considered. Larger deficiencies typically require a lateral window sinus augmentation and a delayed implant placement after graft healing. In all cases, a minimum 1–2 mm buffer from the sinus floor is recommended to avoid membrane trauma [20].
Cone beam CT imaging is invaluable in posterior maxillary sites to assess sinus anatomy, ridge width, and the presence of any septa or undercuts that could influence surgical approach. Horizontal ridge width in molar/premolar sites is often adequate. If < 5–6 mm of buccolingual bone is present, lateral ridge augmentation or use of narrower implants (with careful consideration of load) are options [28]. Generally, a standard or wide-platform implant (4–6 mm diameter) is preferred for molar replacement to better resist occlusal forces. Wide implants can often be placed in posterior sites without deeply countersinking, as esthetic concerns are minimal; however, one must ensure that at least ~ 1 mm of bone will remain around all aspects of the implant to avoid dehiscence (Fig. 5). When ridge width is limited, bone grafting to achieve this 1–2 mm bone sleeve is advised rather than using an undersized implant for a molar load [26, 28].
Fig. 5.

Implant placement for rehabilitation of maxillary first premolar
Esthetic Considerations
The visual demands are lower in the maxillary posterior, but soft tissue health and papillae should not be neglected. Posterior implants usually have broader interproximal spaces, yet if adjacent teeth are present, maintaining ~ 1.5 mm of bone between the implant and those teeth helps preserve the interproximal bone and papilla [34]. The gingival biotype in posterior regions is often thicker, which may be protective against recession. Thus, one-stage surgeries with transmucosal healing abutments are commonly employed in the maxilla posteriorly, unless primary stability is low. Ensuring the implant is centered mesiodistally and buccolingually in the edentulous space will yield a symmetrical crown form that fills the gap without excessive cantilevers [18, 20].
Biomechanical Considerations
Occlusal loads are greatest in the posterior jaws. Implant site preparation must therefore facilitate an implant position that can withstand these forces. The implant should ideally be placed perpendicular to occlusal forces and centered under the future crown to avoid off-axis loading. A faciolingually centered implant minimizes bending moments on the fixture [35, 36]. Sufficient interarch space (crown height space) is another concern: An implant crown in the maxillary posterior should not be excessively tall relative to implant length. A crown-to-implant ratio around 1:1 is considered a sound biomechanical goal [37]. During osteotomy in softer bone, care must be taken not to over-expand the site with excessive drilling, as this can reduce primary stability. Given the poorer initial fixation in D4 bone, a longer healing period before loading (> 4–6 months) is often recommended in the maxillary posterior [38] Immediate loading of a single implant in this region is generally approached cautiously; if attempted, it should only be when high primary stability (> 35 Ncm) is achieved and the prosthesis is out of heavy occlusion [39] (Table 3).
Table 3.
Summary of pre-requisites for maxillary posterior implant
| Aspect | Details |
|---|---|
| Bone quality | D4 (low density) |
| Anatomical considerations | Proximity to sinus; often requires sinus lift |
| Surgical key points | Under-drill osteotomy to enhance primary stability |
| Grafting needs | Lateral/crestal sinus elevation if vertical bone < 10 mm |
| Implant diameter | Prefer 4.5–6 mm (wide-platform) implants |
| Esthetic relevance | Low esthetic concern; emphasize hygiene and emergence profile |
Mandibular Anterior
The mandibular anterior region (incisors and canines) often provides very dense bone (frequently D1–D2 quality) but presents constraints in space and esthetics. The inter-root distance between natural mandibular incisors is narrow, so replacing a missing incisor with an implant requires careful evaluation of mesiodistal space and root alignment. A minimum of ~ 5–7 mm of mesial-distal span at the crest is needed to place even a narrow implant (~ 3 mm diameter) with ~ 1–1.5 mm clearance to adjacent roots [20]. For a missing mandibular canine (which typically has more space), a standard diameter implant (~ 3.5–4 mm) can often be placed [26]. Buccolingual bone width in the anterior mandible is usually limited. At least ~ 6 mm BL width is ideal to encompass a 3–4 mm implant [40]. If the labial plate is extremely thin or dehisced, grafting (either at the time of implant placement or in a preliminary ridge preservation step) should be considered to rebuild the contour and prevent future recession.
The mandibular anterior segment is a low esthetic zone (usually concealed by the lower lip), but symmetry of gingival margins and papilla fill remain important for the patient’s perception of a natural result. Fortunately, papillae tend to be stable if the periodontal support of adjacent teeth is intact. As in other regions, maintaining ~ 5 mm or less from bone crest to contact point favors papilla preservation [27].
Anatomical Considerations
Key anatomical concerns include the proximity of adjacent tooth roots and the lingual undercut of the mandible. Cross-sectional evaluation is recommended to gauge the thickness of bone between the labial cortex and the lingual cortex, which can sometimes exhibit a concavity (sublingual fossa). The implant must be angled and centered within the bony envelope to avoid perforating the lingual plate—a perforation here can risk injury to sublingual vessels or other structures [41]. Fortunately, there are no large sinuses or canals in the anterior mandible, so implants can often be placed to a depth of 12–15 mm as anatomy allows. One must still maintain a safety margin of ~ 1-2 mm above the lower border of the mandible.
If placing an implant in the region of the mental symphysis (between canine roots), clinicians should be mindful of the mental foramen which is more posterior (near premolars)—direct nerve injury is unlikely in the midline, but referred nerve loops can occur toward the canine region in some cases [42]. Preoperative imaging (CBCT) helps identify any anterior loop of the mental nerve to avoid [43] Overall, the dense cortical nature of anterior mandibular bone provides excellent primary stability but is also at higher risk of heat-induced osteonecrosis during drilling. Thus, the surgical protocol should include stepped drill sequences with copious irrigation and intermittent drilling, especially for D1-like bone. Misch recommends using sharp burs at low speed with ample cooling and even suggests bone tapping (pre-cutting threads) in very dense bone to reduce insertion torque and internal microfractures [40]. Healing times in the anterior mandible can be shorter than elsewhere (often 3–4 months) given the excellent primary stability.
Biomechanical Considerations
Functionally, mandibular anterior teeth are subject to shearing forces (during incising) but relatively lower occlusal loads compared to posterior teeth. To ensure longevity, the implant crown should be in light contact in centric occlusion and protected in excursions [44].
For canines, which are critical load-bearing teeth in lateral excursions, the implant should be as large as the space allows (often > 4 mm diameter and ~ 13 mm length if possible) and ideally splinted or protected by the natural dentition in lateral movements. If a narrow implant (< 3.5 mm) is used, a high-strength abutment and precise prosthetic fit are important to prevent screw loosening or fracture under function [45]. Given the minimal mesiodistal space, angled abutments or custom abutments are often needed. In summary, the mandibular anterior region can predictably receive implants when careful attention is paid to space analysis and dense bone management (Table 4).
Table 4.
Summary of pre-requisites for mandibular anterior implant:
| Aspect | Details |
|---|---|
| Bone quality | D1-D2 (very dense) |
| Space constraints | ≥ 5–7 mm MD, ≥ 6 mm BL ridge width |
| Surgical key points | Avoid root proximity and lingual perforation; consider bone tapping |
| Esthetic considerations | Low esthetic zone; preserve papilla if visible |
| Risks | Lingual undercut, thermal damage risk during drilling |
| Biomechanical tips | Use light occlusal contacts; avoid canine-guided lateral forces |
Mandibular Posterior
The posterior mandible is characterized by robust cortical bone (often Misch D2 in the first molar area, D3 more posteriorly) and high masticatory loads, but also by important anatomical hazards such as the inferior alveolar nerve (IAN) and the submandibular fossa. Surgical site preparation in this region must begin with a thorough radiographic assessment of available bone height above the mandibular canal. It is imperative to leave a safety margin of about 2 mm between the implant apex and the superior border of the IAN canal [46]. This guideline helps prevent postoperative neurosensory disturbances by accounting for minor inaccuracies in imaging or implant length (Fig. 6). In addition, one must consider the anterior looping of the mental nerve in the premolar area. A common recommendation is to keep the posterior edge of an implant at least 5 mm anterior to the mental foramen to avoid encroaching on an anterior loop [42, 43, 46].
Fig. 6.

Evaluation of bone width and height for planning of mandibular posterior implant. A safe distance of ~ 2 mm from IAN canal (red dot) is recommended to prevent paraesthesia
Besides nerve anatomy, the lingual concavity (submandibular fossa) on the internal aspect of the posterior mandible is a critical consideration. The mylohyoid muscle attachment often maintains the crest width, while below it the bone can curve inward. An osteotomy drilled perpendicular to the occlusal plane can inadvertently perforate the lingual cortex if this undercut is pronounced [47]. Tactile feedback during drilling (checking for sudden “drop-off”) and careful measurement on cross-sectional images help in detecting and respecting the lingual wall. If a perforation is suspected, the implant length or angulation should be adjusted [48, 49]. The buccal cortex of the mandible is usually thick, but if the ridge is knife-edged, a ridge expansion or graft may be needed. Wide-body implants (5–6 mm) are commonly used for molar sites, but they require at least ~ 7–8 mm of ridge width to accommodate them safely. If such width is not available and augmentation is not feasible, a slightly narrower implant (4–5 mm) may be placed with the understanding that the crown will have a larger emergence profile.
Biomechanical and Surgical Considerations
The mandibular posterior region endures the highest chewing forces, so strategic biomechanical planning is required. It is generally recommended to use the widest implant diameter that the bone will allow, to increase the surface area and reduce stress on the bone–implant interface. During site preparation, the dense nature of mandibular bone means that drills may encounter significant resistance. Rigid control of drilling speed, pressure, and irrigation is needed to prevent heat generation—even more so than in other regions [50, 51]. Many clinicians use a stepped drilling protocol with more intermediate drill sizes (and possibly twist drills replaced by sharper spade or trephine drills) to gradually open the osteotomy in dense bone, as recommended by Misch’s protocol for D2 bone [23, 52]. If the bone at the site is D1-like (very dense cortical throughout), one should consider pre-tapping the site to cut threads, and not force the implant to self-tap entirely, as this could lead to high insertion torque and microfractures.
Occlusal management is crucial for implants in this region. Ideally, the implant crown should be designed in harmonious occlusion with light contact in centric and no heavy excursive interferences. A tall crown on a short implant can act as a lever arm; thus, if an implant length is limited by the canal, one might shorten the crown (by modestly reducing cuspal height) to improve the crown/implant ratio. Also, the platform switching concept (using an abutment narrower than the implant platform) can be utilized to increase the thickness of circumferential bone and soft tissue around the implant neck, which may reduce crestal bone stress under load [53].
Clinical Outcomes
With careful surgical technique and adherence to anatomical guidelines, single-tooth implants in the mandibular posterior have demonstrated success rates comparable to or exceeding those of traditional bridges [54, 55]. The American College of Prosthodontists’ protocols note that while the absence of a second molar is sometimes left unrestored if function is acceptable, the loss of a first molar usually warrants replacement to maintain occlusal stability. By respecting the mandible’s dense bone with the appropriate drilling strategy, protecting vital structures, and optimizing implant positioning—clinicians can predictably rehabilitate single missing molars and premolars (Table 5).
Table 5.
Summary of pre-requisites for mandibular posterior implant
| Aspect | Details |
|---|---|
| Bone quality | D2 (dense cortical with trabecular core) |
| Anatomical hazards | IAN canal, mental foramen, submandibular fossa |
| Surgical strategy | Use CT-guided angulation; maintain 2 mm safety from IAN |
| Implant size | Prefer 4.5–6 mm diameter, ≤ 10 mm length if safe |
| Occlusion management | Avoid tall crowns; target 1:1 crown-implant ratio |
| Healing & success | High success > 95% when load and anatomy are respected |
Surgical Protocols
Optimal surgical technique is paramount for the success of single-tooth implants. The choice of protocol is influenced by clinical presentation, anatomical limitations, and esthetic requirements. Three critical elements—surgical staging, flap design, and timing of implant loading—guide the clinician in tailoring treatment to individual patients (Tables 6, 7).
Table 6.
Summary of different regions for single-tooth implant rehabilitation
| Region | Bone density | Esthetic concern | Common challenges | Ideal buccolingual width (mm) | Min mesiodistal space (mm) | Surgical notes |
|---|---|---|---|---|---|---|
| Maxillary anterior | Type III | High | Thin buccal plate, high esthetic demand | ≥ 6 | ≥ 6–7 | Palatal placement, 3–4 mm apical to gingival margin |
| Maxillary posterior | Type III/IV | Low | Sinus proximity, low bone density | ≥ 6–7 | ≥ 6–7 | May require sinus lift, engage cortical bone |
| Mandibular anterior | Type I/II | Moderate | Narrow ridge, limited space | ≥ 5.5–6 | ≥ 5.5–6 | Careful spacing, consider GBR or ridge split |
| Mandibular posterior | Type I/II | Low | Proximity to nerve, high occlusal load | ≥ 6–7 | ≥ 6–7 | Use CBCT to avoid nerve, gradual drilling essential |
Table 7.
Various implant surgical protocols
| Protocol name | Pros | Cons | Indications |
|---|---|---|---|
| One-stage surgery | Fewer surgeries, reduced patient morbidity, shorter treatment time | Higher risk of soft tissue complications in esthetic areas | Non-esthetic sites with good bone quality and primary stability |
| Two-stage surgery | Better implant protection during healing, ideal for grafted sites | Requires second surgery, longer overall treatment time | Esthetic or grafted sites, soft bone, cases with augmentation |
| Flap technique | Direct bone visualization, facilitates GBR or ridge correction | Increased surgical trauma, longer recovery, greater discomfort | Sites needing bone grafting or ridge modification |
| Flapless technique | Preserves blood supply, less post-op discomfort, faster healing | Limited visibility, risk of improper placement without guidance | Ideal bone and soft tissue architecture, guided surgery availability |
| Immediate implant placement | Preserves soft/hard tissue architecture, reduces total treatment time | Requires primary stability, challenging soft tissue management | Fresh extraction sockets with intact walls and stable conditions |
| Immediate loading | Shortens time to final restoration, increased patient convenience | Requires high insertion torque, risk of failure if overloaded | Carefully selected cases with sufficient primary stability |
One-Stage vs. Two-Stage Surgery
In a one-stage approach, the implant is placed with a healing abutment, while in two-stage protocol, implant is covered by soft tissue during osseointegration [56]. Misch emphasizes the importance of submerged healing in cases involving soft bone or when bone augmentation is performed simultaneously.
Flap vs. Flapless Technique
The flap technique involves reflecting a full-thickness mucoperiosteal flap to allow direct visualization of the bone. In contrast, the flapless approach is often performed using a tissue punch or through guided surgery [57].
Immediate Implant Placement and Loading
Immediate implant placement post-extraction demands meticulous technique to ensure implant stability and soft tissue management [48, 58–61]. Misch and Donati highlight the importance of achieving primary stability (insertion torque > 30–35 Ncm) and avoiding soft tissue trauma [22]. In select cases, immediate loading may be feasible, particularly when occlusal forces can be minimized, and multi-surface contact is avoided during healing [62].
Prosthetic Considerations
Prosthetic planning in single-tooth implant restoration plays a pivotal role in the functional and esthetic success of the treatment. Thoughtful evaluation of space requirements, abutment choice, and restorative materials is essential to ensure biomechanical stability and long-term success.
Restorative Space Requirements
Proper interarch and mesiodistal spacing is fundamental for accommodating both the implant fixture and prosthetic components. Interocclusal (vertical) restorative space of at least 5–7 mm is necessary to accommodate the abutment and prosthetic crown without compromising esthetics or occlusal function (Fig. 7). Inadequate spacing can lead to biomechanical complications, poor emergence profiles, and hygiene challenges [63].
Fig. 7.

Prolonged edentulism can lead to supraeruption of opposing tooth, leading to inadequate interocclusal space
The emergence profile should mimic the natural tooth form to support peri-implant soft tissues. Biological width and papilla preservation are critical, and various studies underscore the importance of maintaining a minimum of 3 mm from the implant shoulder to the free gingival margin [64] (Table 8).
Table 8.
Key dimension for implant restoration
| Parameter | Recommended value | Clinical relevance |
|---|---|---|
| Mesiodistal space | 6–7 mm (for standard diameter implants) | Ensures proper implant placement and emergence profile |
| Interocclusal (vertical) space | 5–7 mm (minimum for abutment + crown) | Allows sufficient room for abutment and crown without functional or esthetic compromise |
| Buccolingual ridge width | ≥ 6 mm (to accommodate 1.5–2 mm bone around implant) | Prevents dehiscence and ensures primary stability |
| Distance from implant to adjacent teeth | ≥ 1.5 mm | Avoids damage to adjacent teeth and maintains papilla |
| Distance between two adjacent implants | ≥ 3 mm | Promotes bone preservation and soft tissue esthetics |
| Distance from implant shoulder to free gingival margin | ≥ 3 mm | Supports soft tissue for natural-looking emergence profile |
Abutment Selection
Abutments may be classified as stock (prefabricated) or custom (CAD/CAM-designed). Stock abutments are cost-effective and suitable for posterior regions where esthetic demand is low and soft tissue contours are forgiving. However, custom abutments are preferred in esthetically demanding cases or where the implant angulation requires compensation. Customization allows ideal emergence profiles, margin placement, and soft tissue support, especially important for thin biotype patients [65, 66].
Cement-retained crowns are preferred in cases with off-axis implant placement and are less technique-sensitive during fabrication. However, they carry a risk of cement-induced peri-implantitis if excess cement is not meticulously removed. Screw-retained prostheses, on the other hand, facilitate easy retrievability, minimize biological complications, and are often preferred in the anterior esthetic zone when proper implant positioning allows for screw access in a non-visible area [67, 68]. Misch and Scott Ganz highlight the use of angulated screw channel technology to combine esthetics with retrievability [4, 19].
Prosthetic Material Choices
Material selection for the final restoration impacts both function and esthetics. Zirconia-based restorations offer excellent biocompatibility, translucency, and strength, making them ideal for anterior and premolar regions. They are especially advantageous in thin gingival biotypes due to their ability to mimic natural tooth color and reduce soft tissue discoloration.
Metal–ceramic restorations, long considered the gold standard, provide proven durability and cost-effectiveness, especially in posterior load-bearing regions. Though less esthetic due to potential gray margins or opacity, newer porcelain systems have enhanced their appearance and clinical viability [69, 70].
Occlusal Considerations
Unlike natural teeth, implants lack a periodontal ligament and have reduced proprioception, making them less capable of absorbing occlusal forces. Thus, precise occlusal management is essential to prevent biomechanical and biological complications [36].
Load Distribution and Biomechanics
Proper load distribution is critical to avoid excessive stress on the bone–implant interface. Implants transmit occlusal forces directly to the surrounding bone without the cushioning effect of a periodontal ligament. Misch emphasized that occlusal overload, particularly in off-axis loading or cantilever situations, can result in marginal bone loss, screw loosening, or even implant fracture. It is recommended that occlusal contacts on implant restorations are light and centralized, especially during lateral excursions [71].
Occlusal Scheme for Single Implants
The occlusal scheme must be tailored to minimize lateral forces. A mutually protected occlusion or canine guidance is preferred in most cases, ensuring that posterior implants disclude during excursive movements (Table 9). For posterior single implants, it is advisable to design centric contacts in the central fossa or near the implant axis. Eccentric contacts should be minimized, and non-working interferences should be avoided. In anterior regions, incisal guidance should be carefully established, particularly when replacing maxillary incisors, to prevent excessive shear forces [72].
Table 9.
Occlusal scheme considerations for single-implant restoration
| Occlusal scheme aspect | Recommended approach | Clinical rationale |
|---|---|---|
| Centric contacts | Centralized and light contact, ideally in central fossa | Minimizes overload at bone-implant interface |
| Eccentric contacts | Minimized or eliminated, especially in posterior regions | Reduces risk of screw loosening and bone loss |
| Cuspal anatomy | Flat cusp inclines to reduce lateral forces | Lowers shear stress on implant components |
| Occlusal table | Narrower table to minimize force magnitude and direction | Decreases lateral load transmission |
| Guidance scheme | Canine guidance or mutually protected occlusion | Protects posterior restorations during movement |
| Posterior disclusion | Ensure posterior implants disclude during excursions | Prevents occlusal trauma and overload |
| Occlusal force distribution | Axial loading preferred; avoid cantilevers or off-axis forces | Enhances long-term biomechanical stability |
Shenoy and Kumar Shah emphasize the importance of using narrow occlusal tables, flat cusp inclines, and appropriate crown height-to-width ratios to reduce torque and bending forces, particularly in high-load regions [18, 20].
Managing Parafunctional Habits
Parafunctional habits such as bruxism and clenching pose a significant threat to implant longevity. These habits generate excessive, repetitive forces that can lead to prosthetic fractures, screw loosening, or even implant failure [73]. Resnick and Misch suggest the use of occlusal guards, particularly at night, for patients with bruxism tendencies. Materials for restorations should also be chosen with durability in mind, favoring metal–ceramic or monolithic zirconia crowns in high-risk cases.
Conclusion
Single-tooth implants represent a highly predictable and esthetically satisfying solution for tooth replacement. Success depends on meticulous treatment planning, precise surgical execution, thoughtful prosthetic design, and long-term maintenance. By integrating digital technologies and evidence-based protocols, clinicians can achieve durable, patient-centered outcomes. As innovations continue to evolve, the future of implant dentistry promises greater precision, personalization, and efficiency.
Funding
No funding was received.
Declarations
Conflict of interest
None.
Footnotes
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Ekfeldt A, Carlsson GE, Börjesson G (1994) Clinical evaluation of single-tooth restorations supported by osseointegrated implants: a retrospective study. Int J Oral Maxillof Implants 9(2):179 [PubMed] [Google Scholar]
- 2.Haas R, Mensdorff-Pouilly N, Mailath G, Watzek G (1995) Branemark single tooth implants: a preliminary report of 76 implants. J Prosthet Dent 73(3):274–279 [DOI] [PubMed] [Google Scholar]
- 3.Guertin G. The decision to restore a tooth or extract it and replace it with a single implant. In: Treatment planning in implant dentistry 2024 Dec 1 (pp. 115–136). Cham: Springer Nature Switzerland.
- 4.Misch CE (2008) Single-tooth replacement: treatment options. Contemporary implant dentistry, 3rd edn. St. Louis, MO, pp 327–66 [Google Scholar]
- 5.Misch CE (2014) Rationale for dental implants. Dental Implant Prosthet 1(2):1–25 [Google Scholar]
- 6.Chatzistavrianou D, Wilson PH, Taylor P (2019) A guide to implant dentistry part 1: treatment planning. Dent Update 46(5):412–425 [Google Scholar]
- 7.Da G (1995) Restoration-driven implant placement with restoration-generated site development. Compend Contin Educ Dent 16:798–802 [PubMed] [Google Scholar]
- 8.Donos N, Calciolari E (2014) Dental implants in patients affected by systemic diseases. Br Dent J 217(8):425–430 [DOI] [PubMed] [Google Scholar]
- 9.Diz P, Scully C, Sanz M (2013) Dental implants in the medically compromised patient. J Dent 41(3):195–206 [DOI] [PubMed] [Google Scholar]
- 10.Hwang D, Wang HL (2006) Medical contraindications to implant therapy: Part I: absolute contraindications. Implant Dent 15(4):353–360 [DOI] [PubMed] [Google Scholar]
- 11.Liddelow G, Klineberg I (2011) Patient-related risk factors for implant therapy. A critique of pertinent literature. Aust Dent J 56(4):417–26 [DOI] [PubMed] [Google Scholar]
- 12.Gómez-Moreno G, Aguilar-Salvatierra A, Fernández-Cejas E, Delgado-Ruiz RA, Markovic A, Calvo-Guirado JL (2016) Dental implant surgery in patients in treatment with the anticoagulant oral rivaroxaban. Clin Oral Implants Res 27(6):730–733 [DOI] [PubMed] [Google Scholar]
- 13.Mankani N, Chowdhary R, Patil BA, Nagaraj E, Madalli P (2014) Osseointegrated dental implants in growing children: a literature review. J Oral Implantol 40(5):627–631 [DOI] [PubMed] [Google Scholar]
- 14.Remizova AA, Sakaeva ZU, Dzgoeva ZG, Rayushkin II, Tingaeva YI, Povetkin SN et al (2021) The role of oral hygiene in the effectiveness of prosthetics on dental implants. Ann Dent Spec 9(1):39–46 [Google Scholar]
- 15.Wood MR, Vermilyea SG (2004) A review of selected dental literature on evidence-based treatment planning for dental implants: report of the committee on research in fixed prosthodontics of the academy of fixed prosthodontics. J Prosthet Dent 92(5):447–462 [DOI] [PubMed] [Google Scholar]
- 16.Greenberg AM (2015) Digital technologies for dental implant treatment planning and guided surgery. Oral and Maxillof Surg Clin 27(2):319–340 [DOI] [PubMed] [Google Scholar]
- 17.Greenberg AM (2015) Cone beam computed tomography scanning and diagnosis for dental implants. Oral Maxillofac Surg Clinics 27(2):185–202 [DOI] [PubMed] [Google Scholar]
- 18.Shah KC, Lum MG (2008) Treatment planning for the single-tooth implant restoration–general considerations and the pretreatment evaluation. J Calif Dent Assoc 36(11):827–834 [PubMed] [Google Scholar]
- 19.Ganz SD (1995) The triangle of bone–a formula for successful implant placement and restoration. Implant Soc: [periodical] 5(5):2–6 [PubMed] [Google Scholar]
- 20.Shenoy V (2012) Single tooth implants: pretreatment considerations and pretreatment evaluation. J Interdiscip Dent 2(3):149 [Google Scholar]
- 21.Shah N, Palan S, Mahajan A, Shah P, Shah R, Kumar P (2014) Why and how maxillofacial disability and impairment due to trauma should be quantified for compensation: a need for nationwide guidelines. J Maxillofac Oral Surg 13(4):425–430 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Donati M, La Scala V, Di Raimondo R, Speroni S, Testi M, Berglundh T (2015) Marginal bone preservation in single-tooth replacement: a 5-year prospective clinical multicenter study. Clin Implant Dent Relat Res 17(3):425–434 [DOI] [PubMed] [Google Scholar]
- 23.Misch CE. Density of bone: effect on surgical approach, and healing. Contemporary implant dentistry. 1999:371–84.
- 24.Ebenezer S, Kumar VV, Thor A (2021) Basics of dental implantology for the oral surgeon. Oral and maxillofacial surgery for the clinician. Springer, Singapore, pp 385–405 [Google Scholar]
- 25.King E M, Schofield J (2023) Restoratively driven planning for implants in the posterior maxilla - Part 1: alveolar bone healing, bone assessment and clinical classifications. Br Dent J 235(8):585–92 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Le B, Nielsen B (2015) Esthetic implant site development. Oral Maxillofac Surg Clin 27(2):283–311 [DOI] [PubMed] [Google Scholar]
- 27.Choquet V, Hermans M, Adriaenssens P, Daelemans P, Tarnow DP, Malevez C (2001) Clinical and radiographic evaluation of the papilla level adjacent to single-tooth dental implants. A retrospective study in the maxillary anterior region. J Periodontol. 72(10):1364–71 [DOI] [PubMed] [Google Scholar]
- 28.Sadan A, Blatz MB, Salinas TJ, Block MS (2004) Single-implant restorations: a contemporary approach for achieving a predictable outcome. J Oral Maxillofac Surg 1(62):73–81 [DOI] [PubMed] [Google Scholar]
- 29.Handelsman M (2006) Surgical guidelines for dental implant placement. Br Dent J 201(3):139–152 [DOI] [PubMed] [Google Scholar]
- 30.Hsu ML, Chen FC, Kao HC, Cheng CK (2007) Influence of off-axis loading of an anterior maxillary implant: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 22(2):301 [PubMed] [Google Scholar]
- 31.Olmedo-Gaya MV, Romero-Olid MN, Ocaña-Peinado FM, Vallecillo-Rivas M, Vallecillo C, Reyes-Botella C (2023) Influence of different surgical techniques on primary implant stability in the posterior maxilla: a randomized controlled clinical trial. Clin Oral Investig 27(7):3499–3508 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Lee SY, Kim SJ, An HW, Kim HS, Ha DG, Ryo KH et al (2015) The effect of the thread depth on the mechanical properties of the dental implant. J Adv Prosthodont 7(2):115 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Sugiura T, Yamamoto K, Horita S, Murakami K, Kirita T (2019) Evaluation of primary stability of cylindrical and tapered implants in different bone types by measuring implant displacement. Contemp Clin Dent 10(3):471–476 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Elgendi MM, Hamdy ISE, Sallam HI (2025) Peri-implant soft tissue conditioning of immediate posterior implants by CAD-CAM socket sealing abutments: a randomized clinical trial. BMC Oral Health 25(1):83 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.King EM, Schofield J (2023) Restoratively driven planning for implants in the posterior maxilla - Part 2: implant planning, biomechanics and prosthodontic planning a proposed prosthodontic complexity index. Br Dent J 235(9):695–706 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Kim Y, Oh TJ, Misch CE, Wang HL (2005) Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale. Clin Oral Implant Res 16(1):26–35 [DOI] [PubMed] [Google Scholar]
- 37.Ercal P, Taysi AE, Ayvalioglu DC, Eren MM, Sismanoglu S (2021) Impact of peri-implant bone resorption, prosthetic materials, and crown to implant ratio on the stress distribution of short implants: a finite element analysis. Med Biol Eng Comput 59(4):813–824 [DOI] [PubMed] [Google Scholar]
- 38.Salem AS, Mowafey B, Elsheikh HAE, Gadallah AMT, Kandil I (2022) Impact of three different surgical drilling protocols on early loaded single implant in posterior maxilla: a 3-year follow-up. J Contemp Dent Pract 23(8):819–827 [DOI] [PubMed] [Google Scholar]
- 39.Huang YC, Huang YC, Ding SJ (2023) Primary stability of implant placement and loading related to dental implant materials and designs: a literature review. J Dent Sci 18(4):1467–1476 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Pedrinaci I, Sun TC, Sanz-Alonso M, Sanz-Esporrin J, Hamilton A, Gallucci GO (2023) Implant survival in the anterior mandible: a retrospective cohort study. Clin Oral Implants Res 34(5):463–474 [DOI] [PubMed] [Google Scholar]
- 41.Juodzbalys G, Wang HL (2010) Guidelines for the identification of the mandibular vital structures: practical clinical applications of anatomy and radiological examination methods. J Oral Maxillofac Res. 1(2):e1 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Thiruvenkata Krishnan D, Joylin K, Packiaraj I, Kandasamy M, Deepak JH, Ilango S et al (2024) Assessment of the anterior loop and pattern of entry of mental nerve into the mental foramen: a radiographic study of panoramic images. Cureus. 16(3):e55600 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Othman B, Zahid T (2022) Mental nerve anterior loop detection in panoramic and cone beam computed tomography radiograph for safe dental implant placement. Cureus 14(10):e30687 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Kan B, Coskunses FM, Mutlu I, Ugur L, Meral DG (2015) Effects of inter-implant distance and implant length on the response to frontal traumatic force of two anterior implants in an atrophic mandible: three-dimensional finite element analysis. Int J Oral Maxillofac Surg 44(7):908–913 [DOI] [PubMed] [Google Scholar]
- 45.Ongun S, Günal Abduljalil B, Önöral Ö (2021) Current approaches to the concept of occlusion in implantology. Cyprus J Med Sci 6(1):75–83 [Google Scholar]
- 46.Section V (2017) Surgical treatment planning considerations. J Oral Maxillofac Surg 75(2):23–27 [Google Scholar]
- 47.Noguchi T, Morita S, Suzuki R, Matsunaga S, Hirouchi H, Kasahara N et al (2023) Structural analysis of the mylohyoid muscle as a septum dividing the floor of the oral cavity for the purposes of dental implant surgery: variety of muscle attachment positions and ranges of distribution. Int J Implant Dent 9(1):49 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Sun Y, Hu S, Xie Z, Zhou Y (2023) Relevant factors of posterior mandible lingual plate perforation during immediate implant placement: a virtual implant placement study using CBCT. BMC Oral Health 23(1):76 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Alqutaibi AY, Alghauli MA, Aboalrejal A, Mulla AK, Almohammadi AA, Aljayyar AW et al (2024) Quantitative and qualitative 3D analysis of mandibular lingual concavities: Implications for dental implant planning in the posterior mandible. Clin Exp Dent Res 10(1):e858 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50.Sindel A, Dereci Ö, Hatipoğlu M, Altay A, Özalp Ö, Öztürk A (2017) The effects of irrigation volume to the heat generation during implant surgery. Med Oral, Patolog Oral Cirugia Bucal 22(4):e506 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51.Ramesh R, Sasi A, Mohamed S, Joseph S (2024) “Compression necrosis”—A cause of concern for early implant failure? Case report and review of literature. Clin Cosmet Investig Dent 16:43–52 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Jang HJ, Yoon JU, Joo JY, Lee JY, Kim HJ (2023) Effects of a simplified drilling protocol at 50 rpm on heat generation under water-free conditions: an in vitro study. J Periodontal Implant Sci 53(1):85 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Gupta S, Sabharwal R, Nazeer J, Taneja L, Choudhury B, Sahu S (2019) Platform switching technique and crestal bone loss around the dental implants: a systematic review. Ann Afr Med 18(1):1 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54.Cristea I, Agop-Forna D, Martu MA, Dascălu C, Topoliceanu C, Török R et al (2023) Oral and periodontal risk factors of prosthetic success for 3-unit natural tooth-supported bridges versus implant-supported fixed dental prostheses. Diagnostics 13(5):852 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Jung TG, Paeng JY, Cho JH, Lee SH (2013) The study on success rate of single implant replacing the mandibular first and second molars. J Korean Acad Prosthodont 51(4):252 [Google Scholar]
- 56.Alfaer AS, Alharbi NY, Alsulami AA, Alharthi SM, Modahi FH, Modahi NH et al (2023) A comparative review one-stage and two-stage dental implants. Int J Commun Med Public Health 10(9):3387–3391 [Google Scholar]
- 57.Chandrshekhar V, Shetty A, Hemavathi U, Iyengar A, Rodrigues NA, Suryavanshi S (2024) A comprehensive analysis of flapless and conventional flap technique in dental implant surgery—A comparative study. Ann Maxillofac Surg 14(2):147–153 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58.Meng HW, Chien EY, Chien HH (2021) Immediate implant placement and provisionalization in the esthetic zone: a 6.5-year follow-up and literature review. Case Rep Dent 2021:1–11 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 59.Fu PS, Tseng FC, Lan TH, Lai PL, Chen CH, Chen JH et al (2023) Immediate implant placement with and without provisionalization: a comparison of a one-year longitudinal study. J Dent Sci 18(3):1361–1367 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 60.Lertwongpaisan T, Amornsettachai P, Panyayong W, Suphangul S (2023) Soft tissue dimensional change using customized titanium healing abutment in immediate implant placement in posterior teeth. BMC Oral Health 23(1):384 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61.Chesterman J, Chauhan R, Patel M, Chan MFWY (2014) The management of traumatic tooth loss with dental implants: Part 1. Br Dent J 217(11):627–633 [DOI] [PubMed] [Google Scholar]
- 62.Ayubianmarkazi N, Deporter D, Dastgurdi ME, Akhondi N, Ketabi M (2022) Long-term results of immediate implantation in mandibular posterior teeth with early loading: a retrospective case series. Dent Res J 19(1):66 [PMC free article] [PubMed] [Google Scholar]
- 63.Misch CE, Goodacre CJ, Finley JM, Misch CM, Marinbach M, Dabrowsky T et al (2005) Consensus conference panel report: crown-height space guidelines for implant dentistry—Part 1. Implant Dent 14(4):312–321 [DOI] [PubMed] [Google Scholar]
- 64.Zheng Z, Ao X, Xie P, Jiang F, Chen W (2021) The biological width around implant. J Prosthodont Res 65(1):11–18 [DOI] [PubMed] [Google Scholar]
- 65.Vetromilla BM, Brondani LP, Pereira-Cenci T, Bergoli CD (2019) Influence of different implant-abutment connection designs on the mechanical and biological behavior of single-tooth implants in the maxillary esthetic zone: a systematic review. J Prosthet Dent 121(3):398-403.e3 [DOI] [PubMed] [Google Scholar]
- 66.Totou D, Naka O, Mehta SB, Banerji S (2021) Esthetic, mechanical, and biological outcomes of various implant abutments for single-tooth replacement in the anterior region: a systematic review of the literature. Int J Implant Dent 7(1):85 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 67.Lemos CAA, de Souza Batista VE, Almeida DAdeF, Santiago Júnior JF, Verri FR, Pellizzer EP (2016) Evaluation of cement-retained versus screw-retained implant-supported restorations for marginal bone loss. J Prosthet Dent 115(4):419–27 [DOI] [PubMed] [Google Scholar]
- 68.Wittneben J, Joda T, Weber H, Brägger U (2017) Screw retained vs. cement retained implant-supported fixed dental prosthesis. Periodontol 2000 73(1):141–51 [DOI] [PubMed] [Google Scholar]
- 69.Ispas A, Iosif L, Popa D, Negucioiu M, Constantiniuc M, Bacali C et al (2022) Comparative assessment of the functional parameters for metal-ceramic and all-ceramic teeth restorations in prosthetic dentistry—A literature review. Biology (Basel) 11(4):556 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 70.Alqutaibi AY, Ghulam O, Krsoum M, Binmahmoud S, Taher H, Elmalky W et al (2022) Revolution of current dental zirconia: a comprehensive review. Molecules 27(5):1699 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 71.Bidez MW, Misch C (1992) Force transfer in implant dentistry: basic concepts and principles. J Oral Implantol 18(3):264–274 [PubMed] [Google Scholar]
- 72.Stilwell C (2024) Occlusal considerations in maintaining health of implants and their restorations. Br Dent J 236(10):773–779 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 73.Manfredini D, Poggio CE, Lobbezoo F (2014) Is Bruxism a risk factor for dental implants? A systematic review of the literature. Clin Implant Dent Relat Res 16(3):460–469 [DOI] [PubMed] [Google Scholar]