Fitting parameters under different kinetic models under different adsorption conditions

Samples Pseudo-first order kinetic model
Pseudo-second order kinetic model
qe (g·g−1) k1 (s−1) R2 qe (g·g−1) K2 (g·g−1·s−1) R2
600°C 5.1436 0.0530 0.9775 0.3648 0.3791 0.9975
650°C 3.8640 0.0542 0.9765 0.4404 0.2803 0.9974
700°C 4.8254 0.0597 0.9784 0.4504 0.4492 0.9993
750°C 5.6504 0.0571 0.9843 0.6354 0.5626 0.9999
3 mg 2.4426 0.0698 0.9662 0.4530 0.1963 0.9997
5 mg 2.9343 0.0664 0.9681 0.4894 0.2083 0.9996
7 mg 5.6504 0.0690 0.9843 0.6354 0.5626 0.9999
9 mg 2.6989 0.0570 0.9951 0.4998 0.1694 0.9991
11 mg 2.2258 0.0690 0.9168 0.5232 0.1697 0.9987
10% 2.7507 0.0729 0.9905 0.5553 0.2625 0.9992
15% 4.1117 0.0618 0.9975 0.6105 0.3987 0.9996
20% 5.6504 0.0571 0.9843 0.6354 0.5626 0.9999
20 mL/min 5.6504 0.0690 0.9843 0.6354 0.5626 0.9999
30 mL/min 6.8179 0.0571 0.9843 0.6156 0.5586 0.9998
40 mL/min 4.5422 0.0607 0.9911 0.5794 0.4844 0.9999