Skip to main content
Medicine logoLink to Medicine
. 2025 Aug 1;104(31):e43588. doi: 10.1097/MD.0000000000043588

Efficacy of binoculus orthokeratology with different optical zone designs in myopic children and adolescents: Contributing factors and establishment of a continuous dynamic follow-up model

Xianmei Zhang a, Yuehua Xin a, Jing Chen a, Shumei Liu b,c,d,*
PMCID: PMC12323964  PMID: 40760516

Abstract

The aim was to investigate the efficacy of binoculus orthokeratology with different optical zone designs in myopic children and adolescents, analyze influencing factors, and establish a dynamic follow-up model. This retrospective cohort study randomly selected 110 myopic patients (220 eyes), aged 8 to 13 years, who underwent orthokeratology correction at the Affiliated Hospital of Hangzhou Normal University from March 2022 to March 2024. Participants were divided into 2 groups: the 5.0 group (110 eyes) with a 5.0 mm optical zone and the 6.0 group (110 eyes) with a 6.0 mm optical zone. After 1 year, the differences in visual acuity, refractive error progression, and axial length control between the groups were assessed. Patients were classified into favorable (axial length change ≤ 0.20 mm) and unfavorable (axial length change > 0.20 mm) groups. Baseline characteristics were analyzed, and logistic regression was used to identify influencing factors. A nomogram-based risk prediction model was constructed and evaluated using receiver operating characteristic curves and area under the curve. A 1-year dynamic follow-up model was also established. The 5.0 group showed better visual acuity, less refractive error progression, and less axial length growth compared to the 6.0 group (all P < .05). Axial length growth > 0.20 mm was observed in 21.00% (42/200) of eyes (unfavorable group), while 89.00% (178/200) showed ≤ 0.20 mm growth (favorable group). Significant baseline differences were found in age, spherical power, cylindrical power, spherical equivalent, axial length, optical zone diameter, and mesopic pupil diameter (all P < .05). Logistic regression identified higher spherical power, cylindrical power, spherical equivalent, axial length, and optical zone diameter as risk factors for unfavorable outcomes, while older age and larger mesopic pupil diameter were protective factors. The nomogram model showed excellent predictive performance with an area under the curve of 0.958 (95% confidence interval: 0.922–0.993). Orthokeratology lenses with a 5.0 mm optical zone demonstrated superior efficacy compared to 6.0 mm lenses. Baseline factors such as age, spherical power, cylindrical power, spherical equivalent, axial length, optical zone diameter, and mesopic pupil diameter influenced treatment outcomes. Continuous dynamic follow-up is essential for optimizing efficacy.

Keywords: axial length, cylindrical power, myopia in children and adolescents, optical zone, orthokeratology, refractive error, spherical equivalent, spherical power, treatment zone

1. Introduction

Myopia, as a prevalent refractive error, demonstrates particularly high incidence rates among children and adolescents. Epidemiological studies[1,2] reveal a concerning upward trend in both prevalence and progression velocity, affecting approximately one-third of the global population, with China’s prevalence nearing 50%. This condition has evolved into a critical public health challenge worldwide. Substantial evidence[3–5] indicates that myopia not only causes visual impairment affecting daily activities, but also predisposes individuals to severe ocular complications such as retinal detachment and cataracts in high myopia cases. Consequently, developing effective interventions for myopia control in pediatric populations has become a pressing medical priority.

Orthokeratology (ortho-k), a nonsurgical and reversible corrective approach, has gained significant attention for its ability to temporarily reshape corneal curvature through specially designed contact lenses.[6] Recent advancements have explored the therapeutic potential of binoculus ortho-k with differential optical zone designs, wherein customized optical zones are tailored to each eye’s specific refractive requirements for more precise correction.[7,8] However, clinical evidence supporting the efficacy of this asymmetric optical zone approach remains limited. Investigating its therapeutic outcomes and influencing factors is therefore crucial for optimizing myopia management strategies.

Previous research[9–12] has identified multiple determinants of ortho-k efficacy, extending beyond lens parameters to include individual ocular characteristics, refractive status, and behavioral factors. Notably, children and adolescents exhibit distinct physiological features during critical ocular development stages, including unique corneal topography and axial elongation patterns compared to adults. This underscores the necessity for comprehensive analysis of efficacy determinants and timely intervention to enhance treatment outcomes. Nevertheless, current understanding of key factors influencing ortho-k effectiveness in pediatric myopia remains fragmented without established consensus.

This study systematically evaluates the therapeutic effects of binoculus differential optical zone ortho-k in pediatric myopia, analyzes associated influencing factors, and establishes a continuous dynamic follow-up protocol. Our findings aim to provide theoretical foundations for personalized ortho-k therapy, effectively decelerate myopia progression, and inform future myopia control strategies. The developed dynamic monitoring model represents a significant advancement towards precision medicine in refractive management.

2. Methods

2.1. Subjects and methods

2.1.1. Study participants

This study was approved by the Ethics Committee of Hangzhou Normal University Affiliated Hospital. This retrospective cohort study included 110 pediatric myopia patients (220 eyes) who underwent orthokeratology correction at the Affiliated Hospital of Hangzhou Normal University between March 2022 and March 2024, based on predefined inclusion criteria and the availability of complete 1-year follow-up data (2022(E2)-HS-007). For the purpose of statistical analysis, each eye was treated as an independent unit. Therefore, a total of 220 eyes from 110 patients were analyzed. All measurements and outcome variables were recorded and analyzed on a per-eye basis, unless otherwise stated. All participants received binoculus differential orthokeratology treatment: 1 eye was fitted with Paragon CRT lenses (10.5 mm total diameter, 6.0 mm optical zone) while the contralateral eye received same-brand lenses (10.5 mm total diameter, 5.0 mm optical zone). The cohort included 53 males (106 eyes) and 57 females (114 eyes), aged 8 to 13 years (mean 10.23 ± 2.10 years). Baseline refractive and ocular biometric parameters are summarized in Table 1. The study was approved by the Ethics Committee of the Affiliated Hospital of Hangzhou Normal University and conducted in accordance with the Declaration of Helsinki, with written informed consent obtained from all participants and their legal guardians.

Table 1.

Baseline demographic and ocular characteristics of the study population.

Variable Value
Number of patients 110
Number of eyes 220
Sex (male) 53 (106 eyes)
Sex (female) 57 (114 eyes)
Age (years) 10.23 ± 2.10
Spherical power (D) ‐2.65 ± 1.55
Cylindrical power (D) ‐1.15 ± 0.75
Uncorrected visual acuity (logMAR) 0.25 ± 0.20
Axial length (mm) 24.85 ± 1.10
Flat keratometry (D) 42.24 ± 2.34
Steep keratometry (D) 43.80 ± 2.43
Central corneal thickness (μm) 532.41 ± 38.54
Mesopic pupil diameter (mm) 3.50 ± 0.35

Inclusion criteria required: (1) meeting indications for orthokeratology without other ocular diseases; (2) suitability for 10.5 mm diameter Paragon CRT lenses with 5.0/6.0 mm optical zones; (3) age 8 to 13 years; (4) complete clinical documentation; (5) good compliance with standardized lens use; (6) normal cognitive function for examinations and follow-up.

Exclusion criteria included: (1) active keratitis or corneal epithelial disorders; (2) concurrent dacryocystitis, dry eye syndrome or blepharitis potentially affecting visual assessment; (3) hearing impairment, amblyopia or congenital color blindness; (4) previous orthokeratology experience, ocular trauma or surgery history.

2.2. Methods

2.2.1. Orthokeratology lens fitting protocol

All participants were fitted with Paragon CRT orthokeratology lenses (Paragon Vision Sciences, USA) featuring a 10.5 mm total diameter and asymmetric optical zones (5.0 mm in 1 eye, 6.0 mm in the contralateral eye). The lenses were manufactured from HDS100 paflufcon D material (refractive index 1.442, center thickness 0.16 mm, oxygen permeability 100, contact angle 42°). Ocular health was evaluated through comprehensive assessments including visual acuity testing, autorefraction, manifest refraction, axial length measurement, slit-lamp examination, fundus imaging, optical coherence tomography, corneal endothelial microscopy, and corneal topography.

Trial lens fitting was performed using proprietary software that integrated baseline flat keratometry and refractive error data. After 30 minutes of closed-eye wear, lens centration and movement were evaluated. Optimal fit was defined by: (1) static positioning at corneal center or slight temporal-inferior displacement, (2) complete optical zone coverage over the pupil, (3) 1 to 2 mm movement with normal blinking, and (4) adequate tear exchange. Final lens parameters were determined via over-refraction. Participants were instructed to wear lenses for 8 to 10 hours nightly during sleep, with scheduled follow-ups to monitor visual correction efficacy and corneal health.

2.2.2. Data collection

(1) This retrospective study extracted clinical data from electronic medical records, including: Demographic characteristics: sex, age at treatment initiation. Refractive parameters: spherical power, cylindrical power, spherical equivalent. Ocular biometrics: uncorrected visual acuity, intraocular pressure, anterior chamber depth, baseline axial length, flat keratometry, corneal diameter, central corneal thickness, corneal astigmatism, treatment zone diameter, and mesopic pupil diameter.

(2) Measurement protocols: ① Refractive error: After removing contact lenses, patients were seated with aligned chin/forehead position for autorefraction (TOPCON KR-800, Japan). Three consecutive measurements of spherical/cylindrical power were averaged, with spherical equivalent calculated as [spherical power + (cylindrical power/2)].

② Visual acuity: Monocular logMAR acuity was measured under standardized illumination using a 5-m ETDRS chart, with proper occlusion of the non-tested eye.

③ Intraocular pressure: Noncontact tonometry (MC-4STOPCON, Japan) recorded 3 measurements per eye while patients fixated on the internal target, with averaged values reported.

④ Axial length: The IOLMaster 500 (ZEISS, Germany) obtained 3 consecutive measurements of optical axial length during fixation on the instrument’s light source.

⑤ Corneal topography: The Sirius 3D corneal topographer (CSO, Italy) acquired keratometric values (flat/steep curvature), corneal diameter, pachymetry, astigmatism, anterior chamber depth, and treatment zone diameter. A senior ophthalmologist (≥5 years’ experience) analyzed all topographic maps, ensuring proper alignment of Placido disk mires and data quality control. All instruments were calibrated according to manufacturers’ protocols prior to data collection.

2.3. Outcome measures

(1) Myopia control efficacy: Evaluated after 1-year follow-up through 3 primary parameters: Best-corrected visual acuity (logMAR); Change in refractive error (spherical equivalent progression); Axial length elongation (mm).

(2) Group stratification and predictive modeling: Participants were dichotomized into the optimal response group (axial elongation ≤ 0.20 mm) and the suboptimal response group (axial elongation > 0.20 mm) based on 1-year outcomes. Intergroup comparisons of baseline characteristics were performed, followed by: collinearity diagnostics (variance inflation factor < 10, tolerance > 0.1) for significantly different variables; logistic regression incorporating noncollinear predictors; nomogram construction for risk stratification; and receiver operating characteristic curve analysis with area under the curve (AUC) quantification to evaluate model discrimination.

2.4. Statistical analysis

Data processing utilized SPSS 25.0 (IBM Corp.) with the following protocol: Categorical variables: Reported as counts [n] or proportions [n (%)]. Chi-square test with Yates’ correction applied when 40 ≤ n < 60 and 1 ≤ expected frequency < 5; standard Pearson χ² test when expected frequency ≥ 5. Ordinal data: Analyzed via Mann–Whitney U test. Continuous variables: Normality assessed by Shapiro–Wilk test: Normally distributed: Mean ± SD, compared by independent t test. Non-normal: Median (P25, P75), analyzed with nonparametric tests. Statistical significance threshold was set at P < .05 (2-tailed). Logistic regression modeling: Dependent variable: Myopia control efficacy (favorable/poor). Covariates: Baseline characteristics with P < .05 in univariate analysis. Variable selection: Stepwise method with entry/exit criteria of P = .05. The P-value for the multivariate comparison was not corrected for multiple comparisons, as the analysis was based on a stepwise logistic regression method with a significance threshold of P < .05 for variable inclusion and exclusion.

3. Results

3.1. Comparison of treatment efficacy with different optical zone diameters in children and adolescents

Treatment outcomes were compared between the 5.0 and 6.0 mm optical zone groups, with each group consisting of 110 eyes (from 110 patients, 1 eye per zone per patient). Analysis was performed per eye. The 5.0 mm group showed better visual acuity than the 6.0 mm group, and the increase in refractive power and axial length growth were lower in the 5.0 mm group compared to the 6.0 mm group, with significant differences (P < .05). This suggests that corneal reshaping lenses with a 5.0 mm optical zone diameter are more effective in correcting myopia, as shown in Table 2.

Table 2.

Comparison of treatment efficacy between different optical zone orthokeratology lenses in children and adolescents (mean ± SD).

Group Eyes (n) Visual acuity (logMAR) Refractive change (D) Axial elongation (mm)
5.0 mm 110 0.89 ± 0.15 0.25 ± 0.10 0.13 ± 0.12
6.0 mm 110 0.85 ± 0.13 0.41 ± 0.18 0.29 ± 0.16
t-value – 2.114 8.150 8.390
P-value – .036 <.001 <.001

3.2. Analysis of myopia control efficacy following orthokeratology in children and adolescents

A total of 110 children and adolescent myopic patients (220 eyes) were included in the study. Based on axial length changes after 1 year of orthokeratology treatment, 42 eyes with an axial length increase of > 0.20 mm (21.00%, 42/200) were categorized into the suboptimal response group, while the remaining 178 eyes with an axial length increase of ≤ 0.20 mm (89.00%, 178/200) were categorized into the optimal response group.

3.3. Univariate analysis of factors influencing orthokeratology treatment outcomes

There were significant differences between the suboptimal response group and the optimal response group in terms of age, spherical power, cylindrical power, spherical equivalent, baseline axial length, optical treatment zone diameter, and mesopic pupil diameter (P < .05). The suboptimal response group had higher values of spherical power, cylindrical power, spherical equivalent, baseline axial length, and treatment zone diameter compared to the optimal response group, but had lower age and mesopic pupil diameter before treatment (see Table 3).

Table 3.

Univariate analysis of factors influencing orthokeratology efficacy in pediatric myopia (mean ± SD).

Parameter Suboptimal response (n = 42) Optimal response (n = 178) Statistical value P-value
Gender (male/female, n) 17/25 71/107 χ2 = 0.005 .944
Age (years) 9.57 ± 1.67 10.14 ± 1.12 t = 3.164 .002
Spherical power (D) ‐3.16 ± 1.15 ‐2.40 ± 1.32 t = 3.435 .001
Cylindrical power (D) ‐0.98 ± 0.40 ‐0.60 ± 0.34 t = 6.292 <.001
Spherical equivalent (D) ‐3.65 ± 1.22 ‐2.90 ± 1.35 t = 3.296 .001
Visual acuity (logMAR) 0.86 ± 0.09 0.88 ± 0.12 t = 1.014 .312
IOP (mm Hg) 15.21 ± 2.54 15.18 ± 2.47 t = 0.070 .944
Anterior chamber depth (mm) 3.12 ± 0.35 3.14 ± 0.29 t = 0.386 .700
Axial length (mm) 25.10 ± 0.86 24.38 ± 0.85 t = 4.927 <.001
Flat keratometry (D) 42.25 ± 2.25 42.23 ± 2.22 t = 0.044 .965
Corneal diameter (mm) 11.87 ± 0.65 11.76 ± 0.58 t = 1.080 .281
CCT (μm) 532.41 ± 38.56 530.24 ± 37.38 t = 0.336 .737
Corneal astigmatism (D) 1.19 ± 0.32 1.17 ± 0.36 t = 0.330 .741
Treatment zone diameter (mm) 3.71 ± 0.46 3.24 ± 0.38 t = 6.914 <.001
Mesopic pupil diameter (mm) 3.38 ± 0.32 3.60 ± 0.43 t = 3.116 .002

3.4. Independent variable assignment table

The efficacy of myopia treatment in children and adolescents was set as the dependent variable. The independent variables included age before treatment, spherical power, cylindrical power, equivalent spherical power, baseline axial length, optical treatment zone diameter, and pupil diameter, which were designated as X1, X2, X3, X4, X5, X6, and X7, respectively. Each independent variable was assigned corresponding values, as shown in Table 4.

Table 4.

Assignment of independent variables for regression analysis.

Variable Factor Assignment method
Y Treatment efficacy of orthokeratology in children/adolescents 0 = Good efficacy (axial elongation ≤ 0.20 mm); 1 = Poor efficacy (axial elongation > 0.20 mm)
X 1 Pretreatment age Actual measured value (yr)
X 2 Spherical power Actual measured value (D)
X 3 Cylindrical power Actual measured value (D)
X 4 Spherical equivalent Actual measured value (D)
X 5 Baseline axial length Actual measured value (mm)
X 6 Optical treatment zone diameter Actual measured value (mm)
X 7 Mesopic pupil diameter Actual measured value (mm)

3.5. Multicollinearity analysis

Collinearity analysis of the differential indicators from the univariate analysis revealed that there was no collinearity between age before treatment, spherical power, cylindrical power, equivalent spherical power, baseline axial length, optical treatment zone diameter, and pupil diameter (VIF ≤ 10, tolerance ≥ 0.1). This suggests that the above indicators can be included in the logistic regression model analysis, as shown in Table 5.

Table 5.

Multicollinearity analysis of independent variables.

Variable VIF Tolerance
Pretreatment age 1.011 0.989
Spherical power 1.111 0.900
Cylindrical power 1.029 0.972
Spherical equivalent 1.017 0.983
Baseline axial length 1.136 0.881
Optical treatment zone diameter 1.038 0.963
Mesopic pupil diameter 1.028 0.973

3.6. Multivariate analysis of factors affecting orthokeratology efficacy in children and adolescents

The results of the logistic regression analysis showed that spherical power, cylindrical power, equivalent spherical power, baseline axial length, and optical treatment zone diameter were risk factors for poor myopia treatment outcomes in children and adolescents wearing corneal reshaping lenses (P < .05), with odds ratio values of 1.563, 20.977, 1.520, 2.671, and 17.460, respectively. Age before treatment and pupil diameter were protective factors (P < .05), with odds value values of 0.590 and 0.237, as shown in Table 6.

Table 6.

Multivariate logistic regression analysis of factors influencing orthokeratology efficacy in children and adolescents.

Factor β coefficient SE Wald χ² P-value OR (95% CI)
Pretreatment age ‐0.527 0.174 9.124 .003 0.590 (0.419–0.831)
Spherical power 0.446 0.138 10.394 .001 1.563 (1.191–2.050)
Cylindrical power 3.043 0.582 27.378 <.001 20.977 (6.709–65.590)
Spherical equivalent 0.419 0.133 9.9 .002 1.520 (1.171–1.973)
Baseline axial length 0.982 0.223 19.479 <.001 2.671 (1.727–4.132)
Optical treatment zone diameter 2.86 0.527 29.492 <.001 17.460 (6.220–49.014)
Mesopic pupil diameter ‐1.438 0.458 9.838 .002 0.237 (0.097–0.583)

3.7. Development and validation of a nomogram prediction model for orthokeratology efficacy in children and adolescents

A nomogram was constructed incorporating pretreatment age, spherical power, cylindrical power, spherical equivalent, baseline axial length, optical treatment zone diameter, and mesopic pupil diameter, which demonstrated excellent predictive value for orthokeratology outcomes. The model showed outstanding discrimination with an AUC of 0.958 (95% confidence interval: 0.922–0.993), indicating high predictive accuracy. The sensitivity and specificity of the model were 92.5% and 88.7%, respectively, further supporting its potential clinical applicability (see Figs. 1 and 2).

Figure 1.

Figure 1.

A nomogram for predicting myopia outcomes in children and adolescents wearing orthokeratology lenses.

Figure 2.

Figure 2.

The internal validation ROC curve of the risk prediction model. ROC = receiver operating characteristic.

4. Discussion

With the rapid development of modern society and widespread use of electronic devices, myopia among children and adolescents has become increasingly prevalent. This condition exerts comprehensive and profound impacts on individuals’ health, daily life, career development, and psychological well-being, making effective control and slowing of myopia progression a crucial research focus in the medical field.[13]

In recent years, orthokeratology has been widely applied in myopia control for young populations. By employing specially designed lenses worn overnight to temporarily reshape corneal curvature through pressure effects, this approach has demonstrated effectiveness in controlling myopia progression and improving visual acuity. However, despite its notable success in treating pediatric myopia, treatment outcomes show considerable variability, with suboptimal results observed in some patients—a phenomenon potentially associated with multiple contributing factors.[14,15]

Consequently, investigating the factors influencing orthokeratology treatment efficacy holds significant value for optimizing myopia control strategies and enhancing intervention outcomes in children and adolescents. The identification of key predictive factors enables more personalized treatment approaches and improved clinical decision-making.

The study data revealed that the 5.0 mm optical zone group demonstrated better visual acuity, smaller increases in refractive error, and less axial elongation compared to the 6.0 mm group, indicating superior treatment efficacy with the smaller 5.0 mm optical zone design. These findings are consistent with research by Zhang Xianmei team,[16] whose retrospective analysis of 100 patients (196 eyes) wearing 10.5 mm Paragon CRT orthokeratology lenses similarly found better myopia correction outcomes with 5.0 mm optical zones.

The therapeutic advantage of smaller optical zones can be attributed to several mechanisms: The 5.0 mm design creates a relatively smaller optical treatment area on the cornea, generating a wider and higher peripheral defocus ring that increases defocus signals entering the pupil. This produces stronger peripheral myopic defocus signals that more effectively inhibit axial elongation and slow myopia progression. Additionally, the 5.0 mm lenses provide more precise focusing by concentrating corneal reshaping within a smaller central area, while the stronger corrective forces create more localized corneal deformation, reducing visual fluctuations and improving stability of visual outcomes.

Our study also identified pretreatment age, spherical power, cylindrical power, spherical equivalent, baseline axial length, optical treatment zone diameter, and mesopic pupil diameter as significant factors influencing treatment efficacy. The developed nomogram showed excellent predictive capability (AUC = 0.958), confirming the predictive value of these factors. These results align with Li Ping’s research[17] demonstrating age-dependent effects of orthokeratology in pediatric myopia control. From an anatomical perspective, ages 10 to 15 represent a “golden period” of axial eye growth when the eye exhibits greater plasticity. Consequently, older children and adolescents typically show better myopia control outcomes with orthokeratology. Furthermore, improved self-management abilities in older adolescents lead to better treatment compliance,[18] ensuring consistent lens wear and sustained therapeutic effects for controlling myopia progression.

The findings suggest that optical zone diameter represents a modifiable treatment parameter that should be personalized based on individual patient characteristics rather than using standardized sizes. The strong predictive model enables clinicians to estimate treatment outcomes and optimize lens selection for improved myopia management in children and adolescents. Future studies should investigate long-term safety and efficacy of smaller optical zone designs, particularly regarding corneal endothelial changes and stability of treatment effects beyond 1 year.

The current study found that the poor-response group had significantly higher baseline spherical power, cylindrical power, spherical equivalent, and axial length compared to the good-response group. Spherical and cylindrical powers directly reflect the patient’s refractive status, while spherical equivalent represents a comprehensive measure combining both spherical and cylindrical powers, serving as an important indicator of overall myopic severity. Higher spherical equivalent values indicate greater degrees of myopia, which requires more precise adjustments in orthokeratology lens design to accommodate more complex corneal morphology and higher refractive correction demands. This increased complexity in lens customization and application precision may introduce greater uncertainty during treatment, potentially leading to relatively poorer therapeutic outcomes.[19]

Previous research by Zhang et al[20] has identified baseline axial length as a key factor influencing myopia control efficacy. As the primary determinant of refractive status, myopia typically results from excessive axial elongation causing light to focus in front of the retina. Orthokeratology works by altering corneal morphology to control axial growth and slow or stop myopia progression. Children and adolescents with longer baseline axial lengths generally have higher degrees of myopia and faster axial growth rates, making axial length a direct determinant of orthokeratology treatment outcomes.[21]

Smaller optical treatment zone diameters indicate that the corrective forces of orthokeratology lenses are more concentrated in the central corneal region, allowing more effective modification of anterior corneal morphology, and curvature to improve focal power and visual acuity. Furthermore, smaller treatment zones create gentler curvature transition gradients between the optical zone and peripheral zone, which helps reduce peripheral retinal tensile stress and inhibits pathological axial elongation by modulating peripheral retinal defocus. Additionally, smaller treatment zone diameters minimize edge-induced optical interference effects and reduce the incidence of irregular astigmatism in the corneal periphery, thereby maintaining more stable visual quality and significantly improving myopia control efficacy.[22] The current finding of larger treatment zone diameters in the poor-response group further supports this conclusion.

Mesopic pupil diameter represents another critical factor influencing orthokeratology outcomes in children and adolescents. Patients with larger mesopic pupils have greater light-perceiving areas, requiring more precise matching between the treatment zone and pupil size/shape in lens design. When the treatment zone adequately covers the pupil area, it enables more effective visual correction and reduces myopia progression during axial elongation. Therefore, patients with larger mesopic pupils may benefit more from customized designs, resulting in superior myopia control outcomes.[23,24] These findings highlight the importance of personalized orthokeratology treatment strategies based on individual ocular characteristics.

Wang Kaijie et al[25] demonstrated that implementing continuous dynamic follow-up for orthokeratology patients significantly improves compliance, reduces complications, and enhances myopia control efficacy. Building upon our findings, we established a comprehensive 1-year dynamic follow-up protocol: (1) Initial evaluation and scheduling: A detailed refractive profile is created during the first visit, including baseline ocular parameters and customized lens selection. Follow-ups are scheduled at critical intervals (1 day, 7 days, 1 month, 3 months, 6 months, 9 months, and 1 year post-fitting). (2) Dynamic monitoring: Non-attendees receive telephone reminders. Each visit includes comprehensive assessments—visual acuity, lens adaptation, wearing time compliance, corneal topography, refractive status, axial length, and ocular surface health. All findings are systematically documented for progress evaluation and treatment optimization. (3) Education and support: Structured education emphasizes proper lens care and follow-up importance. First-time wearers receive psychological support through WeChat groups where experienced parents share success stories, preventing premature discontinuation due to initial slow progress.

This study has several limitations. First, although it included 110 patients (220 eyes), the sample size is still insufficient for broader population-level generalizations. Future studies should incorporate power calculations and enroll larger, multicenter cohorts. Second, the current analysis was based on a 1-year follow-up period, which may not fully capture the long-term efficacy and safety of orthokeratology treatment. Extended longitudinal studies over 2 to 3 years are necessary to assess sustained outcomes. Third, while the developed nomogram showed excellent internal predictive performance, external validation using independent datasets from other clinical centers is required to confirm its generalizability and robustness in diverse populations.

In conclusion, 5.0 mm optical zone orthokeratology lenses demonstrate superior myopia correction. Pretreatment age, spherical/cylindrical power, spherical equivalent, axial length, treatment zone diameter, and mesopic pupil diameter significantly influence outcomes. The high-accuracy nomogram (AUC = 0.958) provides valuable guidance for personalized treatment optimization in pediatric myopia management. These findings support the clinical implementation of customized optical zone selection combined with structured dynamic follow-up protocols to maximize treatment efficacy. Future multicenter studies with extended observation periods will further validate these conclusions.

Author contributions

Conceptualization: Xianmei Zhang, Yuehua Xin, Shumei Liu.

Data curation: Xianmei Zhang, Yuehua Xin, Jing Chen, Shumei Liu.

Formal analysis: Xianmei Zhang, Jing Chen, Shumei Liu.

Visualization: Shumei Liu.

Writing – original draft: Xianmei Zhang, Yuehua Xin, Shumei Liu.

Writing – review & editing: Xianmei Zhang, Jing Chen.

Abbreviations:

AUC
area under the curve
ortho-k
orthokeratology

National Social Science Foundation of China “14th Five-Year Plan” Project (Grant no. BLA220233).

The authors have no conflicts of interest to disclose.

The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.

How to cite this article: Zhang X, Xin Y, Chen J, Liu S. Efficacy of binoculus orthokeratology with different optical zone designs in myopic children and adolescents: Contributing factors and establishment of a continuous dynamic follow-up model. Medicine 2025;104:31(e43588).

Contributor Information

Xianmei Zhang, Email: xianmeiz@163.com.

Yuehua Xin, Email: helloellen@qq.com.

Jing Chen, Email: chenjing8629@163.com.

References

  • [1].Shi XZ, Li ZP, Chen ZM, et al. Retrospective study on meridian-flow acupoint selection with low-frequency therapy for mild myopia in children. J Guangzhou Univ Tradit Chin Med. 2024;41:2980–4. [Google Scholar]
  • [2].Han GY, Zhang YH, Xie XF, et al. Clinical observation of acupuncture combined with abdominal acupuncture-specific electromagnetic wave therapy for adolescent myopia with heart-yang deficiency syndrome. China J Chin Ophthalmol. 2023;33:111–115126. [Google Scholar]
  • [3].Li WT, Wen YM, Zhong LA, et al. Observational study on the effects of retinal laser photocoagulation on accommodative function in myopic patients. Chin J New Clin Med. 2024;17:415–8. [Google Scholar]
  • [4].Qiu MZ, Zou MB, Zhao CH, et al. Therapeutic efficacy of multifocal defocus spectacles combined with atropine eye drops for mild-to-moderate myopia in children. J North Sichuan Med College. 2024;39:1114–7. [Google Scholar]
  • [5].Wang L, Yun JX. Characteristics analysis of atropine-related clinical trials for pediatric myopia registered in international clinical trial platforms. Recent Adv Ophthalmol. 2024;44:802–7. [Google Scholar]
  • [6].Hou JM, Chen HT, Lyu GQ, et al. Comparative efficacy of fully digital versus conventional orthokeratology for adolescent myopia. China J Chin Ophthalmol. 2024;34:737–41. [Google Scholar]
  • [7].Chen M, Zhang R, Zhu C, Peng L, Zhao S, Mao X. Analysis of corneal surface shape following overnight orthokeratology with different optical zone diameters. Front Med (Lausanne). 2024;11:1361. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [8].Meng Z, Chen S, Zhe N, et al. Short-term changes in epithelial and optical redistribution induced by different orthokeratology designs. Eye Contact Lens. 2023;49:528–34. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [9].He WW, Zhang KK, Liu WT, et al. Influencing factors of postoperative efficacy in high myopia cataract patients. Chin J Ophthalmol Otorhinolaryngol. 2020;20:461–4. [Google Scholar]
  • [10].Xiang JB, Guo Y, Yang JF, et al. Treatment outcomes and influencing factors of refractive amblyopia in 208 children. J Clin Res. 2023;40:21–2327. [Google Scholar]
  • [11].Wang X, Lyu Y. Recent advances in risk factors, complications and preventive treatment of myopia. Recent Adv Ophthalmol. 2024;44:564–71. [Google Scholar]
  • [12].Cao K, Hao J, Wang NL. Incidence and its risk factors of high myopia in Chinese rural adults: a population-based six-year cohort study. Eur J Ophthalmol. 2023;33:2139–45. [DOI] [PubMed] [Google Scholar]
  • [13].Li XQ, Wang Z, Zhang LH, et al. Comparison of myopia control effects between defocus-incorporated spectacles and orthokeratology in children. Chin J Ocular Trauma Occupational Eye Dis. 2024;46:87–93. [Google Scholar]
  • [14].Li YL, Su WM, He XH, et al. Comparative efficacy of orthokeratology and peripheral defocus spectacles for myopia control. Int Eye Sci. 2023;23:1887–90. [Google Scholar]
  • [15].Xu FE, Yang M, Zhou L, et al. Efficacy of orthokeratology with small optical zone and high defocus in controlling axial elongation in mild myopic children. Chin J Optometry Visual Sci. 2025;27:126–33. [Google Scholar]
  • [16].Zhang XM, Chen J, Xin YF. Influence of optical zone diameter on orthokeratology efficacy. Chin J Primary Med Pharmacy. 2024;31:1000–5. [Google Scholar]
  • [17].Li P, Liu T, Sun XP. Efficacy and influencing factors of orthokeratology combined with 0.01% atropine for pediatricmyopia. Int Eye Sci. 2021;21:698–701. [Google Scholar]
  • [18].Luo Y, Li X, Chi YJ, et al. Treatment outcomes and influencing factors of amblyopia in children based on behavioral vision therapy. Recent Adv Ophthalmol. 2022;42:887–92. [Google Scholar]
  • [19].Li MH, Zhang J, Li C, et al. Influencing factors of orthokeratology for adolescent myopia control. Med J Chin People’s Armed Police Forces. 2023;34:202–5. [Google Scholar]
  • [20].Zhang H, Gao SF, Zhao X, et al. Random forest and logistic regression-based modeling for orthokeratology efficacy prediction in myopia control. Recent Adv Ophthalmol. 2024;44:637–42. [Google Scholar]
  • [21].Kou SS, Ren YR, Zhuang XY, et al. Factors influencing optical treatment zone diameter in Paragon CRT orthokeratology. Int Eye Sci. 2023;23:867–72. [Google Scholar]
  • [22].Yuan CQ, Wang QJ, Meng X, et al. Efficacy and influencing factors of orthokeratology with different back optic zone diameters for axial length control in pediatric myopia. . Chin J Optometry Visual Sci. 2024;26:824–30. [Google Scholar]
  • [23].Gan L, Wang JF, Zhao WX. Influence of orthokeratology lens decentration on peripheral retinal defocus in myopia. Recent Adv Ophthalmol. 2024;44:287–90. [Google Scholar]
  • [24].Tang SY, Zhang R, Li XC, et al. Compliance and influencing factors of orthokeratology wear in adolescents aged 8–16 years. Modern Prevent Med. 2023;50:3624–9. [Google Scholar]
  • [25].Wang KJ, Ma ZF. Impact of continuous dynamic follow-up on clinical efficacy and compliance in orthokeratology patients. Med J Chin People’s Armed Police Forces. 2024;35:6–9. [Google Scholar]

Articles from Medicine are provided here courtesy of Wolters Kluwer Health

RESOURCES