Table 2.

Summary of the included studies and their characteristics

Authors Bitewing origin Patient demographic Intraoral X-ray unit Image receptor Exposure parameters
a Included studies on the origin of the retrieved bitewing radiographs, patient demographics, radiographic system, image receptor used, and exposure parameters
Ayhan (2024) [14] Kırıkkale University Age: >18 Gendex Expert DC (Gendex Dental Systems, ILB, USA) – 65 kVp, 7 mA
Faculty of Dentistry
Turkey
Karakuş (2024) [26] Necmettin Erbakan University, Faculty of Dentistry, Turkey – Morita Veraview X Type R Intraoral Digital Imaging Device (J. Morita Corp., Kyoto, Japan) Phosphor plates: Soredex Digora Optime image scanner system from Finland 70 kVp, 7 mA, 0.25 s
de Frutos (2024) [23] Six Norwegian institutes and research centres, Norway 56% female 44% male – – –
Age: 19–94
Azhari (2023) [15] King Abdulaziz University Dental Hospital in Jeddah and dental practitioner, Saudi Arabia – – – –
Ahmed (2023) [12] King Abdulaziz University Dental Hospital in Jeddah, Saudi Arabia – – – –
Panyarak (2022) [31] Chiang Mai University, Faculty of Dentistry, Thailand Permanent teeth Heliodent Plus (Dentsply Sirona, Charlotte, NC, USA) Carestream 7600 Phosphor Plate (Carestream, Rochester, NY, USA) and VistaScan Imaging Plates Plus (DÜRR DENTAL, Bietigheim-Bissingen, Germany) –
Kunt (2023) [27] A hospital information system (not specified) Adult – Three direct radiography and one indirect radiography (manufacture not specified) –
Vimalarani (2022) [34] A faculty (not specified) – – – –
Mao (2021) [29] – – – – –
Moran (2021) [30] – – Sirona Heliodent Plus oral X-ray unit (Kavo Brasil Focus) The EXPRESS™ Origo imaging plate (KaVo Dental, Biberach an der Riss, Germany) 70 kVp, 7 mA, 0.25–0.64 s
Bayrakdar (2022) [18] Ordu University, School of Dentistry, Turkey Age: >18 Kodak CS 2200 (Carestream Dental, Atlanta, GA) 2 different phosphor plate systems: Carestream CS 7600(Carestream Dental, Atlanta, GA) and Kodak CR (Carestream Dental, Atlanta, GA) 50 kVp, 5 mA, 0.1 s
Forouzeshfar (2024) [25] Samin Oral and Maxillofacial Radiology Center in Tehran, Iran – Planmeca periapical device, Helsinki, Finland – 60 kVp, 8 mA, 0.128 s
Cantu (2020) [20] Dental clinic at Charité-Universitätsmedizin, Berlin, Germany 52% male Orthophos XG, Dentsply Sirona (Bensheim, Germany), and Dürr Dental (Bietigheim-Bissingen, Germany) – –
48% female
Mean age: 36.5
Age: 14–89
Chaves (2024) [21] Dutch dental practice-based research network, The Netherlands – – – –
Chen (2022) [22] Peking University School and Hospital of Stomatology in Beijing, China – Gendex Expert DC system (Gendex Dental Systems, Hatfield, PA, USA) Storage phosphor plate (manufacture not specified) 65 kVp, 7 mA, 0.125–0.32 s
Bayraktar (2022) [19] Kirikkale University, Faculty of Dentistry, Turkey Permanent teeth Gendex Expert DC (Gendex Dental Systems, IL, USA) – 65 kVp, 7 mA
Panyarak (2023) [32] Chiang Mai University, Faculty of Dentistry, Thailand Permanent teeth Heliodent Plus (Dentsply Sirona, Charlotte, NC, USA) Carestream 7600 Phosphor Plate (Carestream, Rochester, NY, USA) and VistaScan Imaging Plates Plus (DÜRR DENTAL, Bietigheim-Bissingen, Germany) –
Estai (2022) [24] Dental clinics in Perth, Australia Age: 18–60 Australia Photostimulable phosphor plate (not specified) Australia
Lee (2021) [28] Yonsei University, Conservative Dentistry, Korea Permanent teeth Kodak RVG 6200 digital radiography system with CS 2200 (Carestream, Rochester, NY, USA) – –
Baydar (2023) [17] Eski¸sehir Osmangazi University, Faculty of Dentistry, Turkey – ProX periapical X-ray unit (Planmeca, Helsinki, Finland) ProScanner Phosphor Plates and Scanning System (Planmeca, Helsinki, Finland) 60 kVp, 2 mA, 0.05 s
van Nistelrooij (2024) [33] Dutch dental practice-based research network, The Netherlands 15–88 years – – –
202 females, 179 males, and 2 unknown
Ayan (2024) [13] Kirikkale University, Faculty of Dentistry, Turkey Not considered Gendex Expert DC (Gendex Dental Systems, IL, USA) – 65 kVp, 7 mA
Bayati (2025) [16] Tehran University of Medical Science, Faculty of Dentistry, Iran Permanent teeth Owandy dental X-ray machine Photostimulable phosphor plates, and a Sordex Digora scanner 60 kVp, 6 mA, 0.32 s
Authors AI models Images, n, training/total Annotators, n/ experience Lesion prevalence Lesion type Diagnostic performance of AI models
b Included studies on model architecture, dataset characteristics, annotation details, lesion prevalence in the training model, and diagnostic performance metrics of the AI models
Ayhan (2024) [14] YOLOv7-AP-CBAM 1,000/1,170 2/>4 years 0.24 Interproximal F1: 0.82, recall: 0.83, precision: 0. 87
Karakuş (2024) [26] YOLOv8 −/860 2/>3 years – Overall caries F1: 0.95, recall: 0.93, precision: 0.98
Interproximal
D1 F1: 0.96
D2 F1: 0.96
D3 F1: 0.93
Occlusal F1: 0.95
Secondary caries F1: 0.96
de Frutos (2024) [23] YOLOv5 RetinaNet EfficientDet (D0 and D1) 8,342/8,539 6/– – Interproximal YOLOv5 performed best, except for the F1 for enamel caries (EfficientDet D1)
Enamel F1: 0.53, AP: 0.60 (at IoU 0.3), FNR: 0.15
Dentine F1: 0.59, AP: 0.62 (at IoU 0.3), FNR: 0.22
Secondary lesions F1: 0.56, AP: 0.68 (at IoU 0.3), FNR: 0.16
Azhari (2023) [15] Ensemble U-Net (ResNet50, ResNext101, VGG19) –/771 3/– – Interproximal adult
Sound IoU: 0.98
Primary IoU: 0.23
Moderate IoU: 0.19
Advanced IoU: 0.51
Overall Mean F1: 0.52, mean IoU: 0.54
Interproximal Ped
Sound IoU: 0.97
Primary IoU: 0.08
Moderate IoU: 0.17
Advanced IoU: 0.25
Overall Mean F1: 0.44, mean IoU: 0.38
Ahmed (2023) [12] U-Net ensemble (ResNet50, ResNext101, Inception-ResNet-v2) 443/554 2/– – Overall caries Mean F1: 0.54, mean IoU: 0.55
Modified-ICIDAS system
Sound IoU: 0.96
Outer 1/2 enamel IoU: 0.21
Inner 1/2 enamel IoU: 0.23
Outer 1/2 dentine IoU: 0.35
Inner 1/2 dentine IoU: 0.41
Panyarak (2022) [31] YOLOv3 994/1,425 3/>7 0.42 ICCMS™ 2 class At IoU 0.50
Overall caries Precision 0.77, recall: 0.82, F1: 0.79, AP:0.72
0.34 ICCMS™ 4 class At IoU 0.50
0.035 Initial stage Precision: 0.75, recall: 0.67, F1: 0.71, AP: 0.57
0.046 Moderate stage Precision: 0.62, recall: 0.53, F1: 0.57, AP: 0.36
Extensive stage Precision: 0.75, recall: 0.78, F1: 0.76, AP: 0.67
0.08 ICCMS™ 7 class At IoU 0.50
0.12 Outer 1/2 enamel Precision: 0.35, recall: 0.23, F1: 0.27, AP: 0.10
0.13 Inner 1/2 enamel Precision: 0.48, recall: 0.63, F1: 0.55, AP: 0.38
0.035 Outer 1/3 dentine Precision: 0.55, recall: 0.55, F1: 0.55, AP: 0.37
0.026 Mid 1/3 dentine Precision: 0.48, recall: 0.56, F1: 0.52, AP: 0.36
0.02 Inner 1/3 dentine Precision: 0.52, recall: 0.61, F1: 0.56, AP:0.39
Pulp Precision: 0.77, recall: 0.61, F1: 0.68, AP:0.52
Kunt (2023) [27] YOLOv5 RetinaNet 2,992/3,989 1/5 – Overall caries Ensemble models
Faster R-CNN EfficientDet
F1: 0.79–0.80, Precision: 0.81–0.83
Recall: 0.77–0.79, AP: 0.84–0.86 (at IoU 0.5)
Individual models
F1: 0.72–0.76, Precision: 0.71–0.77
Recall: 0.71–0.79, AP: 0.74–0.83 (at IoU 0.5)
Small lesion Individual models at IoU 0.5
AP: 0.66–0.79
Medium lesion AP: 0.78–0.85
Large lesion AP: 0.67–0.85
Vimalarani (2022) [34] DG-LeNet 800/1,000 –/– 0.16 Overall caries Accuracy: 0.99
Sensitivity: 0.91, specificity: 0.99
Premolars Accuracy: 0.99
Molars Sensitivity: 0.93, specificity: 0.99
Accuracy: 0.99
Sensitivity: 0.92, specificity: 0.99
Mao (2021) [29] AlexNet 195/278 3/>3 0.023 Overall caries Accuracy: 0.90 (AlexNet)
(GoogleNet Accuracy: 0.87 (Google Net)
Vgg19 Accuracy: 0.80 (Vgg19)
ResNet50) Accuracy: 0.83 (Resnet50)
Moran (2021) [30] Inception –/112 1/– 0.24 Interproximal The inception model with a 0.001 learning rate performed best
ResNet Incipient Precision: 0.72, recall: 0.87
Specificity: 0.83, NPV: 0.93, AUC: 0.86
0.13 Interproximal Precision: 0.69, recall: 0.733
Advanced Specificity: 0.83, NPV: 0.86, AUC: 0.81
Bayrakdar (2022) [18] VGG-16 –/621 2/>9 – Overall caries VGG-16 (detection)
Sensitivity: 0.84, precision: 0.84, F1: 0.84
U-Net (segmentation)
Sensitivity: 0.81, precision: 0.86, F1: 0.84
Overall caries VGG-16 (detection)
External dataset Sensitivity: 0.77, precision: 0.78, F1: 0.78
U-Net (segmentation)
Sensitivity: 0.76, precision: 0.87, F1: 0.81
Forouzeshfar (2024) [25] VGG16, VGG19, AlexNet, ResNet50 –/1,517 2/– – Overall caries VGG19 performed best
Accuracy: 0.91–0.94
F1: 0.90–0.93, precision: 0.90–0.93
Sensitivity: 0.91–0.95, specificity: 0.89–096
Cantu (2022) [20] U-Net with EfficientNet-B5 encoder 3,293/3,686 4/>3 years – Overall caries Accuracy: 0.80
F1: 0.73
Sensitivity: ≥0.70
Chaves (2024) [21] Mask-RCNN with Swin Transformer backbone 340/425 2/2+3* – Interproximal Interproximal
Primary caries Sensitivity: 0.74, precision: 0.68
F1: 0.69; AUC: 0.81
Secondary caries Sensitivity: 0.70, precision: 0.75
F1: 0.72; AUC: 0.80
Chen (2022) [22] Faster R-CNN 818/978 3/>5 years 0.25 Interproximal Accuracy: 0.87, F1: 0.74, precision: 0.77
All caries Sensitivity: 0.72, specificity: 0.93
E1, E2 Sensitivity: 0.65, precision: 0.69
D1 Sensitivity: 0.69, precision: 0.71
D2 and D3 Sensitivity: 0.85, precision: 0.92
Bayraktar (2022) [19] Modified YOLOv3 800/1,000 2/>10 years 0.16 Interproximal caries Accuracy: 0.95, AUC: 0.87
Sensitivity: 0.72, specificity: 0.98
Precision: 0.87, NPV: 0.97
Panyarak (2023) [32] ResNet-18 ResNet-50 2,333/2,758 3/>7 0.32–0.34 Overall caries ResNet-50 performed best
ResNet-101 0.035–0.036 ICCMS™ 4 class Accuracy: 0.70–0.75, AUC: 0.88–0.91
ResNet-152 0.046–0.047 Initial stage Sensitivity: 0.78–0.83
Moderate stage Specificity: 0.54–0.67
Extensive stage
0.08 Overall caries ResNet-152 performed best
0.12 ICCMS™ 7 class Accuracy: 0.53–0.62
0.13 Outer 1/2 enamel AUC: 0.84–0.87
0.035 Inner 1/2 enamel Sensitivity: 0.63–0.75
0.026 Outer 1/3 dentine Specificity: 0.30–0.34
0.02 Middle 1/3 dentine
Inner 1/3 dentine
Pulp
Estai (2022) [24] Faster R-CNN Inception-ResNet-v2 −/2,468 3/− 0.38 Interproximal Accuracy: 0.87, F1: 0.87, recall: 0.89 precision: 0.86, specificity: 0.86
Lee (2021) [28] U-Net −/304 2/>5 – Overall caries Precision: 0.63, sensitivity: 0.65, F1: 0.64
Baydar (2023) [17] U-Net 400/500 2/>3 – Overall caries Sensitivity: 0.82, precision: 0.95, F1: 0.88
Van Nistelrooij (2024) [33] Mask-RCNN with Swin Transformer backbone 330/413 2/5 0.15 Secondary caries AUC: 0.95, F1 score: 0.77, precision: 0.81
4 Sensitivity: 0.74, specificity: 0.97
Ayan (2024) [13] Modified YOLOv5 1,000/1,200 2/>10 years 0.26 Overall caries mAP: 0.63–0.65
0.06 All caries mAP: 0.52–0.54
0.20 Enamel caries mAP: 0.74–0.77
Dentine caries
Bayati (2025) [16] YOLOv8 442/552 1/– – Interproximal caries Precision: 0.84, recall: 0.80, F1: 0.82, FNR: 0.20
1/>10 years All caries Precision: 0.96, recall: 0.96, F1: 0.96, FNR: 0.04
Enamel caries Precision: 0.80, recall: 0.73, F1: 0.77, FNR: 0.27
Dentine caries

A dash (“–”) indicates missing information.

A star (“*”) indicates that cases with annotator discrepancies were reviewed by additional annotators.

F1, F1 score; AUC, area under the curve; FPR, false-negative rate; NPV, negative predictive value; AP, average precision; mAP, mean average precision; IoU, intersection over union.