Table 4.

Relative deviations of five neutron beam parameters at the BSA collimator exit were calculated using different combinations of proton and neutron libraries compared to the reference values in Table 3.

Proton/neutron libraries Inline graphic
(%)
Inline graphic
(%)
Inline graphic (%) Inline graphic
(%)
Inline graphic
(%)
ENDF/B VII.1 ENDF/B VIII.0 −0.34 0.00 −0.46 0.35 −1.28
ENDF/B VIII.1 8.61 −0.17 −2.37 25.68 0.99
JEFF-3.3 0.38 0.01 1.08 −0.97 7.38
CENDL-3.2 −0.16 0.00 −1.01 0.55 9.40
JENDL-5.0 2.83 0.23 2.68 −23.53 8.80
ENDF/B VIII.1 ENDF/B VII.1 −7.38 0.20 0.54 −19.26 −0.85
ENDF/B VIII.0 −7.85 0.23 0.46 −19.04 −1.55
JEFF-3.3 −7.02 0.14 1.83 −20.32 6.92
CENDL-3.2 −7.51 0.09 1.04 −18.86 7.79
JENDL-5.0 −5.51 0.44 4.53 −37.83 7.92
CP2020 ENDF/B VIII.0 −0.35 0.00 −0.65 0.18 −0.69
ENDF/B VIII.1 8.55 −0.19 −2.33 25.44 1.58
JEFF-3.3 0.36 0.00 1.60 −1.13 7.74
CENDL-3.2 −0.26 0.06 −0.67 0.50 10.08
JENDL-5.0 2.80 0.20 2.92 −23.42 8.93
JENDL-5.0 ENDF/B VII.1 −2.51 −0.28 −3.17 29.87 −6.79
ENDF/B VIII.0 −2.87 −0.26 −3.30 30.24 −8.83
ENDF/B VIII.1 5.63 −0.44 −4.90 63.94 −7.88
JEFF-3.3 −2.15 −0.27 −2.55 28.57 −1.28
CENDL-3.2 −2.66 −0.33 −2.52 30.64 1.10