Table 7.
Relative deviations of five neutron beam parameters at the BSA collimator exit compared to original ones after replacing mg, F, pb, li, and Cu neutron reaction cross-sections in JEFF-3.3 library with corresponding data from ENDF/B VII.1 library.
| Neutron libraries |
(%) |
(%) |
(%) |
(%) |
(%) |
|
|---|---|---|---|---|---|---|
| JEFF3.3 | ENDF/B VII.1(F) | 0.08 | −0.01 | −0.51 | 0.66 | 0.06 |
| ENDF/B VII.1(Mg) | 0.01 | −0.01 | −0.76 | 0.08 | −0.39 | |
| ENDF/B VII.1(Pb) | −0.58 | 0.06 | −1.66 | 0.52 | −3.64 | |
| ENDF/B VII.1(Li) | 0.00 | 0.00 | 0.03 | 0.00 | 0.00 | |
| ENDF/B VII.1(Cu) | 0.16 | −0.04 | 0.15 | −0.08 | −2.90 | |
| ENDF/B VII.1 | −0.36 | 0.00 | −1.58 | 1.14 | −7.18 | |