Table 8.
Relative deviations of five neutron beam parameters at the BSA collimator exit compared to original ones after replacing mg, F, pb, li, and H neutron reaction cross-sections in CENDL-3.2 library with corresponding data from ENDF/B VII.1 library.
| Neutron libraries |
(%) |
(%) |
(%) |
(%) |
(%) |
|
|---|---|---|---|---|---|---|
| CENDL-3.2 | ENDF/B VII.1(F) | 0.05 | −0.03 | −0.05 | 0.77 | −0.25 |
| ENDF/B VII.1(Mg) | −0.09 | −0.06 | 0.68 | −0.74 | 7.99 | |
| ENDF/B VII.1(Pb) | 0.22 | −0.04 | 0.08 | −0.12 | 3.57 | |
| ENDF/B VII.1(Li) | 0.06 | 0.00 | 0.23 | −0.08 | 0.57 | |
| ENDF/B VII.1(H) | 0.03 | 0.00 | −0.26 | −0.01 | −17.67 | |
| ENDF/B VII.1 | 0.26 | −0.06 | 0.68 | −0.49 | −9.16 | |