As the brain switches from wakefulness to sleep, processing of external information weakens while restorative processes, including glymphatic removal of waste products, are activated. Yet, it is not known what drives brain fluid transport during natural sleep. Here, we employed an array of novel technologies to interrogate the forces that propel glymphatic clearance and identified tightly synchronized oscillations in norepinephrine, cerebral blood volume and cerebrospinal fluid (CSF), as the strongest predictors of glymphatic inflow and clearance during NREM sleep. Optogenetic stimulation of the locus coeruleus drove both vasomotion and anti-correlated changes in CSF signal. Glymphatic fluid transport was enhanced by direct stimulation of vascular smooth muscle cells, demonstrating that vasomotion acts as a pump driving CSF into the brain. The sleep aid zolpidem suppressed norepinephrine oscillations and glymphatic clearance. Thus, norepinephrine-driven vascular dynamics, detectable as the micro-architectural organization of NREM sleep, are the key determinants of glymphatic clearance in sleep.

Keywords: Neuromodulators, sleep aid, sleep architecture, infraslow oscillations, fiber photometry, biosensors, EEG, EMG, aging, cardiovascular diseases

Introduction

The glymphatic system is a highly organized, brain-wide network for cerebrospinal fluid (CSF) transport that exports protein waste, including amyloid and tau1–3. Glymphatic fluid transport also plays a critical function in water homeostasis4, antigen presentation5, immune cell trafficking6,7 and in delivery of solutes, including glucose8. Due to the lack of lymphatic vessels, the brain relies on CSF circulation through the tissue to remove waste proteins. The glymphatic system uses the perivascular spaces as low-resistance routes for fast influx of CSF into deep brain regions1. Increased stiffness of blood vessels, brain injury, or gliosis are all factors that can impair glymphatic flow and thereby predispose to the development of neurodegenerative diseases9–13.

Glymphatic fluid transport is enhanced during sleep14–19. The link between sleep and the glymphatic system has, in recent years, received substantial attention as poor sleep often precedes neurodegenerative diseases by years, and sleep disturbances are a predictor of early dementia20–22. Yet, the mechanistic underpinning of how sleep and wakefulness affect glymphatic flow is not clear. Initial studies in anesthetized mice showed that cardiac pulsatility is a driver of glymphatic inflow23,24, but modeling studies have pointed toward cardiac pulsatility merely having a mixing effect25,26. Instead, it has been suggested that slow vasomotion, the spontaneous and rhythmic constriction and dilation of arteries27–31, may be a driving force for solute clearance in NREM sleep, though direct evidence is lacking. In parallel, biosensor imaging has in recent years revealed that NREM sleep is characterized by regular oscillations in brain norepinephrine (NE) levels with a frequency in the range of ~0.02 Hz32–34. It is known that these slow oscillatory fluctuations in NE are important for memory performance and the micro-architectural organization of sleep32,33,35, but the effects of the rhythmic increases in NE on the vasculature and CSF dynamics are unknown, albeit NE is known to be a potent vasoconstrictor36,37.

Technical limitations have to date prevented advances in rodent glymphatic imaging studies due to the lack of methods to visualize CSF dynamics during natural, unrestrained sleep. Consequently, glymphatic rodent studies are primarily based on anesthesia used as a surrogate for sleep. However, most if not all anesthetic regimens suppress or eliminate the characteristic features of natural sleep, such as oscillatory release of NE, micro-arousals, vasomotion and REM sleep, which renders anesthesia unsuited to dissect the drivers of glymphatic flow in natural sleep38–41. Albeit neuroimaging of the human brain does not yet have the spatial resolution to quantify CSF flow in the periarterial space, several studies have shown that CSF movement in the 4th ventricle is temporally linked to neuronal slow wave activity and vascular volume changes during NREM sleep17,42. However, CSF flow in the 4th ventricle is not representative of glymphatic parenchymal flow43, leaving the fundamental question of which forces drive glymphatic flow during natural sleep unanswered.

We here developed a novel approach, “flow fiber photometry”, that enabled recordings of blood and CSF dynamics during long and uninterrupted periods of wakefulness, NREM and REM sleep by avoiding head-fixation and allowing the mice to move freely around in their home cage during the recording. Chronic labeling of blood was accomplished by liver secreted fluorescently-tagged albumin44 concurrently with tagging of CSF by a fluorescent tracer to interrogate the impact of NE oscillations on both vascular and CSF dynamics. The combined recordings of NE (GRABNE2m)45, blood44, CSF and EEG/EMG revealed a surprisingly rich and tightly linked dynamic interrelationship between brain states and fluid dynamics.

The observations identify locus coeruleus (LC)-induced NE oscillations as the key mechanism of slow vasomotion and thereby of glymphatic solute clearance during natural sleep. These findings have broad implications for understanding what constitutes restorative sleep and slow vasomotion, and why vascular dysfunction lead to glymphatic failure and predispose individuals to neurodegenerative diseases.

Results

NE drives state-dependent vasomotion

Recent work has shown that NE release from the LC displays an infraslow (~0.02 Hz) oscillatory pattern during NREM sleep32–34. Given that NE is a potent vasoconstrictor36,37, how does the LC-mediated NE release affect the cerebral vasculature? 4 month-old wildtype C57Bl/6 mice of either sex expressing the fluorescent NE sensor GRABNE2m45,46 were implanted with EEG, EMG and a fiber optic cannula in the dorsal cortex. Furthermore, mice were infected with AAV8/P3-alb-mScarlet, which targets the expression of the transgene to hepatocytes, resulting in fluorescent tagging of blood albumin44. This approach enabled prolonged and repeated recordings of NE and blood albumin in freely behaving mice across multiple cycles of sleep and wakefulness (Figure 1A). By observing the mice during their natural sleep-wake cycle, we found that fluctuations in NE and blood albumin signal were anti-correlated across both wakefulness, NREM sleep and REM sleep (Figure 1B–D). The blood albumin signal lagged after the NE signal by 0.29±0.6 seconds in wakefulness and by 0.69±0.3 seconds in NREM sleep, while a broader time dependency was observed in REM sleep. Furthermore, the dynamics of the NE/blood albumin signal differed between behavioral states with low amplitude fluctuations in wakefulness and larger and more regular fluctuations in NREM sleep. In REM sleep, a gradual decline in NE level along with a similar gradual increase in blood albumin signal occurred in accordance with the REM sleep-induced vasodilation previously reported31,47. The average blood albumin fluorescence was significantly higher in REM sleep than during wakefulness and NREM sleep (Figure 1E). The average trough-to-peak amplitudes of the NE oscillations were higher in NREM sleep than in wakefulness and REM sleep (Figure 1F). Also, the variability of the correlation coefficient between NE and blood albumin signal across mice was more than twice as high in wakefulness and REM sleep (standard deviation = 0.13) as in NREM sleep (standard deviation = 0.06) (Figure S1A), indicating that NE and blood dynamics are more tightly correlated in NREM sleep than in wakefulness and REM sleep. Slow vasomotion is a well-established phenomenon, but the exact mechanism driving the regular cycles of constriction-relaxation of vascular smooth muscle cells is not well defined29,48,49. Since NE and blood albumin signals were closely correlated and NE is a vasoconstrictor36,37, we next asked if NE release from the LC drives vascular dynamics during NREM sleep. To answer this, EEG and EMG electrodes were implanted and the light-activated cation channel channelrhodopsin-2 (ChR2) was expressed bilaterally in the LC, while GRABNE2m was expressed in the medioprefrontal cortex (mPFC) of TH-Cre transgenic mice (Figure 1G). A one-second stimulation (10 ms, 10 mW blue light pulses) of increasing frequency (5, 10 and 20 Hz) was delivered to the LC every 30 seconds during NREM sleep while cortical NE and vascular dynamics were recorded. Upon LC stimulation, an increase in NE and a decrease in blood albumin signal were consistently noted (Figure 1H). The increase in NE and the decrease in blood signal were tightly coupled. Increasing the frequency of stimulation increased, in a dose-dependent manner, the increase in NE and the decline in vascular signal. Panadrenergic inhibition (i.p. administration of the α1-adrenergic receptor antagonist prazosin, the broad β-adrenergic receptor antagonist propranolol, and the α2-adrenergic antagonist atipamezole, PPA13,14) blocked the LC-induced decrease in blood albumin signal (Figure 1H). The increase in NE and the decrease in blood albumin signal exhibited a significant correlation that was abolished by PPA, demonstrating that LC-mediated NE release in a dose-dependent manner elicits the decrease in blood albumin (Figure 1I and Figure S1B). In further support of this conclusion, optogenetic inhibition of LC activity by expression of the light-driven proton pump Arch-eGFP in TH-Cre mice decreased the NE signal concurrently with increasing the blood albumin signal. Arch-eGFP activation also negatively impacted the otherwise tight time dependency between NE and blood signals (Figure S1C–E). Thus, both optogenetic activation and inhibition of the LC control the dynamics of the cerebral vasculature.

Figure. 1. NE drives state-dependent vasomotion.

Figure. 1.

(A) Continuous fiber photometry combined with EEG and EMG recordings were acquired in freely behaving adult wildtype mice expressing the norepinephrine (NE) biosensor, GRABNE2m in the dorsal cortex, and AAV8/P3-alb-mScarlet in the liver to label blood albumin. Fiber photometry signal ΔF/F was calculated as the percentage change from the median of the first 10 minutes of the recording. (B-D) Representative recording of NE, blood, EMG and EEG during wakefulness (B), NREM sleep (C) and REM sleep (D) with cross-correlation of blood albumin signal compared to NE during each state (n=6 for wake and NREM sleep and n=5 for REM sleep). (E) Average level of blood fluorescence during periods of wakefulness, NREM and REM sleep calculated as change from mean NREM levels (n=8, effect size = 0.67, One-way ANOVA with Geisser-Greenhouse correction and Tukey’s multiple comparison). (F) Average peak-to-trough amplitude of the NE signal during periods of wakefulness, NREM and REM sleep (n=5, effect size = 0.90, One-way ANOVA with Geisser-Greenhouse correction and Tukey’s multiple comparison). (G) NE and blood fluctuations were recorded in freely behaving TH-Cre mice with GRABNE2m expression in the mPFC and bilateral ChR2 expression in the LC for optogenetic stimulation (1 second stimulation every 30 seconds with increasing stimulation frequency). The mPFC was used in this experiment to make space for a fiber optic cannula to deliver pulses of light to the LC and another fiber optic cannula to measure NE and blood dynamics in the mPFC. Prior to the experiment, the mice were injected I.V. with BSA-Alexa Fluor 594 to visualize the vasculature. (H) Average NE (top) and blood (bottom) traces upon LC stimulation with 5 Hz, 10 Hz, 20 Hz and 20 Hz in mice pre-treated with pan-adrenergic inhibitors (PPA) (n=3). (I) Correlation between the peak in NE and the decrease in blood signal following LC stimulation (n=3, Pearson correlation, color-coding depicts data points from different mice). Shaded area around line graphs represents +/− SEM. **P < 0.01, ****P < 0.0001. Min = minute. See also Figure S1.

The sensitivity of the NE signal to hemoglobin artifacts was tested in mice expressing the NE-insensitive GRAB sensor, GRABNEmut (Figure S1F–G). These mice only showed minor signal fluctuations compared to mice expressing GRABNE2m, and the peak signal during the infraslow NREM oscillation in mice expressing GRABNEmut was 7.2% of the peak signal in GRABNE2m-expressing mice.

To test if both arteries and veins exhibit the vascular dynamics observed with fiber photometry, miniscope imaging of the cortical vasculature and GRABNE2m fluorescence was performed in a separate group of mice (Figure S1H). The analysis showed that artery diameter but not vein diameter was highly dynamic and that NE and artery diameter displayed the same state-dependent oscillatory patterns and negative correlation that were observed with fiber photometry (Figure S1I–N). This is in accordance with previous studies31,47, which found the same dynamic nature for penetrating arteries, indicating that pial as well as penetrating arteries exhibit infraslow oscillations during NREM sleep.

Thus, vasomotion induced by optogenetic activation of the LC is mediated via NE acting on cerebral arteries. Combined, this set of data provides direct evidence for the conclusion that it is LC-mediated NE release that drives vasomotion during NREM sleep.

NE-mediated vasomotion drives state-dependent and anti-correlated fluctuations in CSF

How do cerebral blood dynamics affect CSF flow in the brain? Mice were transduced to express P3-alb-mNeonGreen in the liver44 along with implantation of EEG and EMG electrodes and a fiber optic cannula in the ventral cortex (claustrum) as the ventral brain regions exhibit higher tracer inflow relative to the dorsal cortex1,50,51. About 3 weeks later, a small red fluorescent CSF tracer (tetramethylrhodamine (TMR) dextran, 3 kDa) was administered into CSF via a tube chronically implanted in the cisterna magna two days prior to the experiment52 (Figure 2A). Of note, previous studies have documented that implantation of chronic EEG screws does not impair CSF flow but is associated with a minor enhancement53 and that chronic cannula implantation does not alter glymphatic flow54. We here repeated the analysis and found that chronic implantation of the fiber optic cannula did not disrupt global glymphatic flow compared to control mice with only EEG electrodes implanted (Figure S2A–C).

Figure 2. NE-mediated vasomotion drives state-dependent and anti-correlated fluctuations in CSF.

Figure 2.

(A) The CSF tracer tetramethylrhodamine dextran (dextran, 3 kDa) was injected into the cisterna magna (CM) of mice with AAV-Alb-mNeonGreen labelled blood plasma, while EEG and EMG was recorded along with fiber photometry in the ventral cortex. Representative fiber photometry traces of CSF tracer and blood signal (top) and EEG and EMG (bottom) are shown. Fiber photometry signal (ΔF/F) was calculated as the percentage change from the median of the signals 10 minutes before the beginning of the tracer injection. (B-D) Representative recording of CSF tracer, blood signal, EMG and EEG (all during the descending part of the CSF trace), and cross-correlation of CSF tracer compared to blood albumin signal during wakefulness (B), NREM sleep (C), and REM sleep (D) (n=6). (E) Average level of CSF tracer fluorescence during periods of wakefulness, NREM and REM sleep calculated as change from mean NREM levels (n=11–12, effect size = 0.67, One-way ANOVA with Geisser-Greenhouse correction and Tukey’s multiple comparison). (F) NE and CSF fluctuations were recorded in freely behaving TH-Cre mice with GRABNE2m expression in the mPFC and bilateral ChR2 expression in the LC for optogenetic stimulation (1 second stimulation every 30 seconds with increasing stimulation frequency). Prior to the experiment, the mice were injected with a tracer (3kDa dextran) into the CSF via a chronically implanted catheter in the cisterna magna. (G) Average NE (top) and CSF tracer signal (bottom) upon LC stimulation with 5, 10, 20 Hz stimulation in naïve mice and 20 Hz stimulation in mice pre-treated with pan-adrenergic inhibitors (PPA, n=3). (H) Correlation between the peak in NE and the peak in CSF tracer following LC stimulation (n=3, Pearson correlation, color-coding depicts data points from different mice). Shaded area around the line graphs are +/− SEM. Min = minute. See also Figure S2.

We utilized ‘Flow fiber photometry’ – a technique that combines fiber photometry with blood and CSF tracers and is the first methodology that allows simultaneous longitudinal tracking of the CSF and blood dynamics, while avoiding the use of anesthesia. Following injection of tracer into the CSF, the CSF tracer signal increased gradually and then slowly decreased over a time span of hours (Figure 2A). The CSF tracer signal fluctuated dynamically in the opposite direction of the blood albumin signal with a small lag in the blood albumin signal after the CSF tracer signal (0.3±3 seconds in wakefulness, 0.6±0.4 seconds in NREM sleep and 0.5±2.3 seconds in REM sleep) (Figure 2B–D). The average CSF tracer level was highest in NREM sleep and lowest in REM sleep (Figure 2E). Comparison between fiber photometry dynamics in the ventral and dorsal cortex and between hemispheres revealed that both the CSF and the blood albumin dynamics are symmetric across the two hemispheres and in the central and dorsal brain areas (Figure S2D–E) in accordance with the cross-hemispheric vascular symmetry previously reported47,55. CSF imaging with fiber photometry was validated by miniscope imaging through a GRIN lens in the ventral cortex during CSF tracer injection, which closely corresponded to the inflow kinetics observed with fiber photometry (Figure S2F–I). To rule out that the CSF tracer signal changes were caused by hemoglobin absorption artifacts or pH changes56, the signal dynamics were assessed in two types of control experiments: signal dynamics were analyzed in mice expressing pH-insensitive mCherry57–60 and in mice before and after CSF tracer injection to compare auto-fluorescence with CSF tracer signal. The mCherry fluorescence signal exhibited only minor fluctuations while the auto-fluorescent signal before tracer injection showed no fluctuations (Figure S2J–M). In contrast, the CSF tracer signal after tracer injection exhibited large, well-defined oscillations, arguing that the CSF tracer dynamics observed were not the result of hemoglobin absorption or other signal artifacts.

The tight relationship between blood and CSF dynamics points to LC-mediated NE release as a controller of both blood and CSF dynamics. To test this, a chronic catheter was implanted in the cisterna magna of TH-Cre transgenic mice with bilateral Cre-dependent ChR2 expression in the LC as well as GRABNE2m and a fiber optic cannula in the mPFC and in the LC (Figure 2F). Two days following the catheter implantation and while the mice were freely behaving in their home cage, a 3 kDa redshifted tracer (TMR dextran), was injected into the CSF while the NE and CSF tracer signal was continuously recorded from the mPFC. After 2 hours, optogenetic stimulations (10 mW) with increasing frequencies (5, 10 and 20 Hz) once every 30 seconds were delivered to the LC and the corresponding NE and CSF tracer signals were recorded. Upon LC stimulation, both the NE and the CSF tracer signal increased in a stimulation frequency dependent manner (Figure 2G). The increase in CSF was abolished in mice pre-treated with the panadrenergic receptor cocktail, PPA, demonstrating that it is NE that mediates the CSF dynamics via vasoconstriction. Plotting the amplitude of NE and CSF tracer following LC stimulation showed a positive correlation that was abolished by PPA in accordance with the idea that LC-mediated NE release controls CSF dynamics (Figure 2H and Figure S2N).

Thus, CSF and cerebral blood volume exhibit anti-correlated and state-dependent fluctuations that are controlled by NE released by the LC.

Infraslow oscillations in NE, cerebral blood and CSF volume are phase-locked during NREM sleep

Studies of vasomotion in awake mice and modeling studies have previously suggested that slow vasomotion may act as a “pump” for driving CSF flow30,31,61. We next set out to characterize the relationship between NE, blood and CSF during NREM sleep. Regular NE oscillations were observed in the fiber photometry traces during NREM sleep (Figure 3A). These oscillations were associated with an infraslow rhythm in EEG sigma power (8–15 Hz) known to result from the generation of sleep spindles during the descending phase of the NE oscillation32–34. Power spectral density analysis of NE, blood and CSF signals normalized to the area under the curve showed that all three signals exhibited infraslow oscillations in the 0.01–0.02 Hz range during NREM sleep (Figure 3B). REM sleep also displayed an oscillatory component but with a faster (0.02–0.03 Hz) frequency, while wakefulness displayed a much slower frequency peak below ~0.005 Hz. Analysis of the NE signal, blood albumin signal and CSF tracer signal time-locked to the sigma power peaks revealed that all signals either exhibited a peak or a trough when sigma power was highest (Figure 3C). We noted that an oscillatory cycle often was terminated by a micro-arousal with a brief shift to wake-like EEG and muscle activity33,35. To interrogate the association between micro-arousals and the cerebrovascular dynamics, we time-locked NE, blood albumin and CSF tracer signal during the efflux phase to the beginning of each micro-arousal (Figure 3D). To efficiently separate micro-arousals and awakenings, only micro-arousals with a duration of 1–10 seconds were included in the analysis. The analysis showed a distinct pattern with a sharp increase in NE levels, a sharp and transient decrease in blood albumin signal, and a sharp and transient increase in CSF signal. Thus, the oscillatory dynamics in NE, sigma power, blood and CSF in association with micro-arousals constitutes an integral part of the infraslow oscillation during NREM sleep that tightly links neural activity and vascular dynamics (Figure 3E).

Figure 3. Infra-slow oscillations in NE release, cerebral blood volume and CSF volume are phase-locked during NREM sleep.

Figure 3.

(A) Left: representative NREM EEG spectrogram, sigma power trace, NE trace and blood trace from mice expressing GRABNE2m and AAV8/P3-alb-mScarlet. Right: representative NREM EEG spectrogram, sigma power trace, blood trace and CSF trace during from mice expressing AAV8/P3-alb-mNeonGreen subjected to CSF tracer injection. (B) Power spectrum of NE (top), blood signal (middle) and CSF tracer signal (bottom) dynamics during wakefulness, NREM sleep and REM sleep. Values are normalized by division with the area under the curve from 0–0.03 Hz (n=5 for NE and n=8 for blood and CSF tracer). (C) Average NE, blood and CSF tracer time-locked to peaks in sigma power during NREM sleep. (D) Average NE, blood and CSF tracer during micro-arousals (MA) lasting 1–10 seconds (n=5, average of 35–80 micro-arousals from each mouse). (E) Schematic diagram showing the relationship between oscillations in NE, EEG sigma power, blood and CSF, as well as terminology used to describe the oscillations. Shaded area around line graphs represents +/− SEM.

Optogenetically enhancing the frequency of arterial oscillations potentiates CSF tracer influx

We previously showed that optogenetically stimulated vasoconstriction in anesthetized transgenic mice expressing channelrhodopsin-2 in vascular smooth muscle cells (Sm22-Cre:Ai32-ChR2) directly enhances CSF tracer influx43. To test the hypothesis that oscillations in blood is the pump that drives glymphatic flow during NREM sleep, we set out to test if the same principle rules in naturally sleeping mice. A 3 second (10 Hz, 50 ms duration) stimulation every 10 second paradigm was chosen because the kinetics of the vascular constriction most accurately replicated the spontaneous NE-induced changes in blood albumin signal. This increased the frequency of the vascular oscillation from 50 to 10 seconds (Figure 4A). The optogenetic stimulation was delivered via a fiber optic cannula implanted in the dorsal cortex of Sm22-Cre:Ai32-ChR2 mice with EEG and EMG electrodes. The presence of stimulation-induced vasomotion was confirmed in transgenic mice injected with a vascular tracer where fiber photometry was acquired via the same fiber optic cannula between the stimulations (Figure 4B). Stimulation of the vascular smooth muscle cells induced a decrease in blood albumin signal in both wakefulness and NREM sleep (Figure S3A) and in a similar range to natural micro-arousals (Figure 4C). To assess the effect of an enhanced arterial oscillation frequency on CSF flow, Sm22-Cre:Ai32-ChR2 mice and Sm22-Cre−/−:Ai32-ChR2 control mice were three weeks after the implantation of electrodes and a fiber optic cannula subjected to implantation of a chronic catheter in the cisterna magna for injection of CSF tracer (Figure 4D). Two days after catheter implantation, and during the inactive phase of the mice, 3 kDa TMR dextran was slowly injected into the CSF while optogenetic stimulation was delivered through the fiber optic cannula. EEG and EMG were recorded continuously while the tracer signal was recorded between the stimulations by fiber photometry in Cre and Cre−/− mice (Figure 4E). The injection was started once the mice were asleep and the stimulation continued for one hour during which the mice were left undisturbed. During the injection and circulation time, mice in both groups spent a comparable duration of time in NREM sleep (66–87%) (Figure 4F). The stimulation did not evoke changes in the EMG or EEG during NREM sleep (Figure S3B), and analysis of EEG power bands during and between stimulations showed no effect of the stimulation on the spectral properties of the EEG (Figure S3C–D). Additionally, mice with and without expression of ChR2 did not exhibit differences in the number of wake and NREM sleep bouts (Figure S3E). For analysis of the effect of increased arterial oscillations on glymphatic influx to the brain, brain areas in the stimulated and unstimulated hemisphere were compared (Figure 4G). While no difference in tracer content was identified between the hemispheres in the ventral surface far away from the stimulation light (Figure 4H), the hippocampus and the dorsal cortex both exhibited significantly higher tracer penetration in the stimulated hemisphere (Figure 4I–J). Transgenic mice without the Cre construct were tested using an identical stimulation paradigm but for this group the analysis showed no differences between the stimulated and unstimulated hemisphere (Figure S3F). In summary, increasing the frequency of vascular oscillations during NREM sleep by optogenetic stimulation locally enhanced glymphatic flow. These observations show that it is the cycles of arterial constriction-dilation that drive CSF inflow.

Figure 4. Optogenetically enhancing the frequency of arterial oscillations potentiates CSF tracer influx.

Figure 4.

(A) A unilateral fiber optic cannula was implanted in the cortex of Sm22-Cre:Ai32-ChR2 mice to optogenetically (10 Hz 470 nm blue light, 3 sec light-on and 7 sec light-off) induce constriction of vascular smooth muscle cells during NREM sleep. Continuous fiber photometry, EEG and EMG recordings were acquired in freely behaving mice that had received an i.v. injection of a 70 kDa dextran tracer to visualize blood dynamics while optogenetic stimulation (blue vertical lines) was delivered through the fiber implant. (B) Average blood trace during stimulation trains. (C) Comparison of blood signal dynamics of a micro-arousal (MA) and optogenetically-induced vasoconstriction (stim) (left) and quantification of the trough induced by micro-arousals and optogenetic stimulations normalized to the micro-arousal trough (right) (n=4, one-tailed Wilcoxon matched-pairs signed rank test compared to micro-arousal, P=0.25). (D) The same stimulation paradigm was used in Sm22-Cre:Ai32-ChR2 and Sm22-Cre−/−:Ai32-ChR2 mice implanted with a chronic CM cannula to investigate the effect of enhanced arterial oscillations on CSF influx. For a total of 1 hour during and after the injection of a CSF tracer (3 kDa dextran), fiber photometry, EEG and EMG recordings were acquired while mice were optogenetically stimulated (a total of 360 stimulations), where after the brain was dissected. (E) Average fiber photometry trace from mice with the transgene (cre+) and mice without the transgene (cre−) during 6 stimulation trains (n=7–8). (F) Quantification of time mice spent in NREM sleep and wakefulness during the tracer infusion and tracer circulation time (n=8, two-way ANOVA with Sidak’s multiple comparison). (G) Representative images of a brain slice showing the stimulated hemisphere and the unstimulated hemisphere (top) and a higher magnification insert of the hippocampus is the same mouse (scale bar = 1 mm). (H-J) Quantification of tracer inflow to the stimulated (stim) and unstimulated (unstim) hemisphere in the ventral surface (effect size = 0.26, P = 0.16) (H), the hippocampus (effect size = 0.72, P = 0.004) (I), and the dorsal cortex (effect size = 0.46, P = 0.04) (J) (n=8, paired t-test). Shaded area around line graphs represents +/− SEM. See also Figure S3.

The frequency of micro-arousals correlates with glymphatic clearance in NREM sleep

The data so far indicates that CSF flow in the perivascular spaces (PVSs) is driven forward by dynamic constriction and enlargement of the cerebral arteries, and thereby the PVS volume, rather than a steady PVS size27–31. We next asked if glymphatic clearance correlates with the infraslow NE oscillations in natural sleep. Based on the finding that most infraslow oscillations were terminated by a micro-arousal (Figure 3A), micro-arousals, scored based on a transient increase in EMG activity and change to wake-like EEG, were used as a surrogate for quantifying NE oscillations in NREM sleep. This allowed exchange of the fiber optic cannula with a cannula for injection of radioactive tracer directly into the brain tissue51,54,62 and subsequent quantification of glymphatic clearance with SPECT/CT (Figure 5A). One week prior to the experiment, a cannula for tracer delivery was implanted (Figure S4A) along with EEG and EMG electrodes and a custom-made head bar for fixation during the scans. The long delay between surgery and glymphatic clearance analysis allowed glymphatic fluid transport to normalize54. We have previously used a similar approach to show that glymphatic efflux peaks during natural sleep and anesthesia and is suppressed by wakefulness63. A small SPECT tracer [99mTc]-DTPA (molecular weight = 489 Da) was injected slowly in the awake mice and immediately followed by acquisition of a SPECT/CT scan to provide a snapshot of the tracer content in the brain51,62. The mice were then left undisturbed in their cage for 5 hours to allow enough time for glymphatic clearance to take place, before a second SPECT/CT scan was acquired to quantify [99mTc]-DTPA clearance. Glymphatic clearance efficiency was defined as the amount of radioactivity left in the brain at the second scan compared to the first scan (Figure 5B). During the 5 hours between the two scans, mice spent from 37.6 to 58.2% of the time in NREM sleep and 4.7 to 8.3% time in REM sleep (Figure S4A). Correlation of tracer clearance with basic parameters of sleep showed that neither total time spent in NREM sleep, time spent awake, time spent in REM sleep, nor the number of REM bouts predicted tracer clearance (Figure 5C and Figure S4B). Clearance was also not correlated with NREM delta power (1–4 Hz), theta power (4–8 Hz), sigma power (8–15 Hz) or beta power (13–20 Hz). Furthermore, periods of sustained wakefulness (i.e. wake periods > 20 seconds) did not correlate with tracer in the brain. Instead, the amount of tracer left in the brain exhibited a significant negative correlation with the frequency of micro-arousals, meaning that a higher frequency of micro-arousals correlated with a more efficient clearance of tracer from the brain (Figure 5C). Based on the principle of preservation of mass, glymphatic clearance relies on CSF inflow. We therefore tested if glymphatic influx also correlates with the frequency of micro-arousals. The analysis performed after injection of 3 kDa TMR dextran into the cisterna magna, 30 minutes circulation time during sleep or wakefulness followed by brain dissection and imaging confirmed the earlier observation that CSF tracer influx was significantly higher in mice that had been sleeping during the experiment than mice that had been kept awake (Figure S4C–E)14. Additionally, glymphatic influx exhibited a positive correlation with the frequency of micro-arousals, while not correlating with total time spent in NREM sleep, NREM delta power, theta power, sigma power or wake episodes > 20 seconds (Figure S4F). Thus, both the glymphatic influx and the clearance studies pointed towards the conclusion that it is the infraslow vasomotion that drives brain fluid transport. An important question is whether oscillations in NE promote glymphatic flow and micro-arousals in parallel or if micro-arousals themselves promote glymphatic flow. To answer this, we analyzed the vascular response to peaks in NE and subdivided them into two groups: one with the EEG/EMG signature of a micro-arousal and another group in which the NE peak did not evoke a micro-arousal (Figure S4G). The analysis showed that NE peaks associated with a micro-arousal induced vasoconstriction in a similar manner to NE peaks that were not associated with a micro-arousal (Figure S4H–J). This point towards the conclusion that CSF flow is promoted by NE oscillations, i.e. vasoconstriction, but do not require the presence of micro-arousals. Thus, vasomotion and micro-arousals are parallel events triggered by NE oscillations (Figure S4K).

Figure 5. The frequency of micro-arousals correlates with glymphatic clearance in NREM sleep.

Figure 5.

(A) To investigate clearance, mice were implanted with a probe in the striatum, EEG and EMG electrodes and a head bar for fixation in the SPECT/CT scanner. Seven days after, the radiotracer [99mTc]-DTPA was injected into the brain followed by a baseline SPECT/CT scan, 5 hours of undisturbed EEG/EMG recording, and another SPECT/CT scan. (B) Representative SPECT image from the first scan (left) and second scan (right) showing tracer distribution overlaid on a CT background. (C) Radioactivity in the intracranial space at the second scan normalized to intracranial radioactivity in the first scan plotted against the percent time spent in NREM sleep, NREM delta power, the number of wake bouts lasting longer than 20 seconds and the number of micro-arousals/time spent in NREM sleep during the 5 hours between the first and second scan (n=15, Pearson correlation). See also Figure S4.

In summary, the frequency of micro-arousals displayed a stronger correlation with glymphatic influx and clearance than all other measures of sleep analyzed, including total amount of NREM sleep and NREM delta power, suggesting that NE oscillations is the main determinant of glymphatic clearance in NREM sleep. Furthermore, the observations indicate that glymphatic influx is not correlated with statically high NE (wakefulness) or statically low NE (REM sleep), but depends on the dynamic NE release that occurs in NREM sleep for optimal flow.

The sleep aid zolpidem impairs neuronal and vascular oscillations and suppresses CSF tracer inflow

The observations so far indicate that infraslow vascular oscillations are the main driver of glymphatic influx and clearance during NREM sleep. How well do sleep aids replicate this novel aspect of sleep microarchitecture? Zolpidem (Ambien) is a non-benzodiazepine prescribed to treat insomnia64,65. However, zolpidem has been reported to alter sleep microstructure66 and decrease EEG power67,68 in mice. We next asked if zolpidem affects NE oscillations and glymphatic flow in NREM sleep. Pilot experiments comparing the effects of 1 mg/kg and 5 mg/kg zolpidem66,67,69 showed that a 5 mg/kg dose decreased mobility after the injection without a marked effect on the marble burying test the next day, suggesting that the sedation was short-lived (Figure S5A–B). Administration of 5 mg/kg zolpidem in mice expressing GRABNE2m in the dorsal cortex resulted in a reduction in magnitude the infraslow EEG sigma power oscillation (Figure 6A–B) and sigma power amplitude (Figure S5C) along with a suppression of the infraslow NE oscillation magnitude in NREM sleep (figure 6C). The lack of defined NE peaks co-occurred with an increase in EEG-EMG defined micro-arousals (Figure S5D–E). Combined analysis of EEG/EMG scored micro-arousals and NE peaks detected from the fiber photometry trace showed a ~70% increase in the number of micro-arousals that were not associated with a peak in NE (Figure S5F). Microdialysis samples collected from prefrontal cortex demonstrated that Zolpidem decreased baseline NE by approximately 50% for several hours (Figure 6D). Simultaneous fiber photometry measurements of blood albumin signal and CSF tracer in AAV8/P3-alb-mNeonGreen expressing mice injected with a 3 kDa CSF tracer (TMR dextran) into the cisterna magna enabled tracking of vascular and CSF dynamics before and after injection with zolpidem. The correlation of EEG sigma power with the blood albumin signal and CSF tracer signal during NREM sleep was markedly suppressed after zolpidem administration compared to before (Figure 6E). This was supported by miniscope recordings of the cortical vasculature before and after zolpidem, which showed that zolpidem abolished the infraslow oscillations in artery diameter during NREM sleep (Figure 6F). Do these alterations in sleep microarchitecture alter glymphatic flow? To answer this question, mice were divided into two groups that received either an injection of 5 mg/kg zolpidem or a similar volume of vehicle. When the mice fell asleep, a fluorescent tracer (TMR dextran, 3 kDa) was injected into the CSF and allowed to circulate for 30 minutes. The brains were then harvested, vibratome sections were prepared and the CSF tracer distribution was analyzed (Figure 6G). Mice that received zolpidem fell, as expected, asleep faster than vehicle control mice but exhibited a significant decrease in EEG power (Figure S5G–H). Analysis of the brains from mice receiving zolpidem or vehicle showed that glymphatic tracer influx was lower in the zolpidem group than in the control group receiving vehicle (Figure 6H–J).

Figure 6. The sleep aid zolpidem impairs neuronal and vascular oscillations and suppresses CSF tracer inflow.

Figure 6.

(A) Continuous fiber photometry combined with EEG and EMG recordings were acquired in freely behaving adult wildtype mice expressing the norepinephrine (NE) biosensor GRABNE2m in the dorsal cortex and AAV-Alb-mScarlet in the liver to label blood albumin. Recordings were performed before and after an IP. Injection of 5 mg/kg zolpidem (the pre zol period is the hour before zolpidem administration and the post zol period is the first hour after zolpidem administration). (B) Representative traces of EEG sigma power oscillations from a mouse during NREM sleep before and after zolpidem treatment (top) and average power spectrum of the infraslow NREM sigma power oscillation before and after zolpidem treatment (bottom) (n=4–5, two-way ANOVA with Geisser-Greenhouse correction, P=0.0007). (C) Representative fiber photometry traces showing NE oscillations during NREM sleep before and after zolpidem treatment (top), and power spectrum of NE oscillations during NREM sleep before and after zolpidem treatment (bottom) (n=4, two-way ANOVA with Geisser-Greenhouse correction, P=0.0009). Insert shows the average NE signal amplitude during NREM sleep in mice before and after zolpidem treatment (n=4, paired t-test P=0.0006, effect size=0.99). (D) Extracellular prefrontal cortex NE levels measured with microdialysis in mice receiving vehicle or zolpidem. Dotted line at time = 0 shows the time of injection (n=7, effect size=0.91, two-way ANOVA with Sidak’s multiple comparison). (E) Cross-correlation of blood signal (left) and CSF tracer signal (right) compared to sigma power before and after administration of 5 mg/kg zolpidem (n=5). (F) Average power spectrum of the artery diameter imaged with a miniscope during NREM sleep in a separate cohort of mice before and after zolpidem treatment (n=4–5, two-way ANOVA with Geisser-Greenhouse correction, P=0.0183). (G) Mice with EEG/EMG electrodes and a cannula in the cisterna magna were injected with either vehicle or 5 mg/kg zolpidem and left undisturbed in the cage for 15 minutes or until sleep was observed, where after a 3 kDa fluorescent tracer (FITC dextran) was injected into the cisterna magna. 30 minutes after the end of the tracer injection, the brain was dissected and imaged. (H) Representative images of brain slices of a control mouse that received vehicle (left) and a mouse that received zolpidem (right). (I) Average mean pixel intensity from brain sections across the rostro-caudal axis from mice receiving vehicle or zolpidem (n=6–7, two-way ANOVA with Sidak’s multiple comparison). (J) Average difference compared to the vehicle-treated group (n=6, one-tailed Wilcoxon matched-pairs signed rank test compared to control, P=0.065). Shaded area around line graphs represents +/− SEM, error bars on bar graphs are SD. *P < 0.05, **P < 0.01, ***P < 0.001. See also Figure S5.

Thus, zolpidem dampens the infraslow NE dynamics of sleep, which suppresses CSF tracer influx, despite increasing the duration of sleep. Additionally, the observed increase in micro-arousal and decrease in glymphatic influx support that it is infraslow NE oscillations, and not micro-arousals, that drive CSF flow. In summary, our results point to a mechanism where LC-mediated NE release drives slow vasomotion, which in turn promotes glymphatic clearance (Figure 7).

Figure 7. CSF flow through the glymphatic system during sleep is mediated by vascular volume dynamics controlled by infraslow oscillations in NE release.

Figure 7.

Diagram of the mechanism behind glymphatic brain clearance during NREM sleep. Infraslow oscillations in NE drive slow rhythmic constrictions and dilations of the cerebral arteries, which in turn promote CSF flow (blue arrows) along the perivascular space and through the brain tissue. Because the cerebral blood volume and CSF volume is constricted to the confined space of the skull, the dynamics in vascular tone promote an anti-correlated infraslow oscillatory pattern in blood volume and CSF volume within the intracranial space. The directional flow of CSF and interstitial fluid promotes removal of waste metabolites from the brain tissue towards draining lymph nodes in the periphery.

Discussion

The motivation for this study was to understand what drives glymphatic flow during sleep. We used multiple approaches to interrogate the effects of NE dynamics on cerebral blood and CSF across wakefulness, NREM sleep and REM sleep. First, we showed that optogenetic stimulation of the LC results in NE release that, in a dose-dependent manner, decreased vascular volume. Pan-adrenergic receptor blockage eliminated vasoconstriction induced by LC activation consistent with the notion that NE is a potent vasoconstrictor36,37 (Figure 1). We also showed that cortical blood and CSF tracer signals displayed a tightly coupled and anti-correlated relationship with distinct characteristics across the different states of brain activity (Figure 2). The key observation was that NREM sleep is characterized by a stereotypic pattern of ~0.02 Hz oscillations synchronized across NE, blood and CSF (Figure 3). We hypothesized that the infraslow oscillatory increases in NE that drive slow vasomotion work as a pump to promote glymphatic flow during NREM sleep. We critically tested the causality between vascular dynamics and CSF flow by directly stimulating ChR2-expressing vascular smooth muscle cells thereby bypassing neural activity (Figure 4). The manipulation of vascular diameter during sleep enhanced CSF tracer influx to the brain regions closest to the stimulation but not in more distant regions. Additionally, correlation analysis in naturally sleeping mice showed that the frequency of NE oscillations, quantified by the frequency of micro-arousals, during NREM sleep displayed a stronger correlation with glymphatic flow than all other measures analyzed, including total amount of NREM sleep, REM sleep and NREM delta power (Figure 5), while wakefulness, as expected, suppressed glymphatic inflow (Figure S4). Conversely, although the sleep aid zolpidem promoted sleep, it impaired the infraslow oscillations in NE, blood and CSF, and diminished the vascular and neuronal oscillatory dynamics resulting in a reduction in glymphatic flow (Figure 6). In summary, correlation analysis, as well as optogenetic stimulation or inhibition of LC, or direct stimulation of vascular smooth muscle cells, as well as indirect manipulations of slow vasomotion (zolpidem) document that it is the infraslow NE oscillations that triggers slow vasomotion, which in turn is the primary driver of glymphatic flow in NREM sleep (Figure 7).

The evolving insight into what drives CSF flow in the sleeping brain

The results presented here provide further support to prior studies that identified sleep as a key driver of glymphatic flow in the rodent and human brain14,16,19,63. Thus, they contradict a recent publication claiming that glymphatic clearance is inhibited during sleep and enhanced during wakefulness70. A reason for this inconsistency may be that the mentioned publication measured tracer dispersion from one point in the brain to another but did not quantify actual brain clearance, i.e. efflux from the brain. We have recently shown that wakefulness suppresses tracer injection and dispersion within the brain compared with sleep and anesthesia63. Importantly, detection of tracer efflux from the brain, detected as signal in the blood compartment, confirmed the existing literature by showing that tracer efflux to peripheral tissues was higher in sleep and anesthesia compared with wakefulness63.

EEG slow wave activity (SWA) has been proposed to induce periarterial CSF inflow. A comparison of different anesthetic regimens showed that CSF tracer inflow correlated with the power of SWA50. Yet, several physiological parameters, such a neuromodulator and vascular dynamics differ in anesthesia versus natural sleep38–41. Anesthesia potently suppresses NE release and vasomotion71–73 possibly explaining why EEG delta wave activity (1–4 Hz) and cardiac pulsatility is the major driver of glymphatic influx in anesthetized mice17,74. Also, the increase in the interstitial space volume that occurs during anesthesia will facilitate CSF influx14. Magnetic resonance encephalography (MREG) mapping of pulsation in the human brain showed already in 2016 that infraslow vasomotion represents an alternative driver of glymphatic flow75 and later studies from the same group documented that infraslow vasomotion is enhanced during sleep76. The importance of slow vasomotion was recently supported by the observation that infraslow vasomotion predominate during NREM sleep in the rodent brain31,47 and chronic sleep fragmentation impairs both slow vasomotion and glymphatic function77. Yet, what triggers this vasomotion has until now not been defined. Most prior studies have concluded that vasomotion reflects intrinsic activity of vascular smooth muscle cells78,79. The optogenetic manipulation of LC along with monitoring of NE and vascular volume presented in Figure 1 is the first data linking the activity of LC to slow vasomotion. Why is that important? The first answer is that the dose-dependent constriction of cortical vessels demonstrate a surprisingly tight correlation to LC activity, indirectly suggesting that the sympathetic projections from the trigeminal ganglion that innervates the pial arteries likely play a less important role in vascular control during sleep80,81. Secondly, the inverse relationship between blood and CSF volume in cortex has to our knowledge not previously been documented. This observation extends the finding that vascular volume changes drive CSF flow in the 4th ventricle to include parenchymal CSF inflow17. Thus, vascular volume changes is the pump forcing CSF transport in both the 4th ventricle and within the cortical tissue. One implication of this observation is that the arterial “pumping” of CSF is expected to function optimally when the elasticity of the cerebral vessels is high. Stiffening of the vascular wall, whether induced by chronic hypertension or vascular amyloidosis, will result in smaller amplitude changes in vascular volume and thereby in reduced glymphatic clearance82. In fact, a hallmark of aging and neurodegenerative diseases is the impairment of functional hyperemia, i.e., vasodilation in response to neural activity83. Thus, establishing the connection between vascular dynamics and CSF inflow is important because it provides the mechanistic link between vascular pathology and glymphatic stagnation that may explain the increased risk of Alzheimer’s disease in patients suffering from cardiovascular diseases84,85.

A question that remains to be fully understood is what accounts for the suppression of glymphatic flow during wakefulness. One suggestion is that the hemodynamic/CSF coupling boosts glymphatic flow during sleep, because the expansion of the interstitial space volume is a prerequisite for CSF inflow. The interstitial space expands by as much as 60% during sleep and anesthesia and the reduced resistance towards fluid movement facilitates fluid dispersion within the tissue14. In addition, astrocyte endfeet may act as valves that promote CSF flow through the perivascular spaces and prevent backflow86,87. Such valves will, combined with the oscillatory pressure imposed by the vascular dynamics and the enlarged brain interstitial space, propel CSF influx as a consequence of reduced parenchymal resistance toward fluid flow during sleep14. It is also important to note that glymphatic flow is partly active in quiet wakefulness, whereas active wakefulness potently suppresses CSF inflow88. In fact, very recent studies have documented that glymphatic flow is enhanced by optogenetic stimulation of excitatory neurons in hippocampus across a broad range of frequencies89 and similar observations have been done in response to sensory gamma stimulation (40 Hz, visual or auditory)90. Common to both studies was the finding that neural synchrony drive glymphatic clearance. Our study support and extend this concept by showing that vascular and CSF volumes are anti-correlated, i.e., the functional hyperemia induced by neural activity promotes CSF flow. Another question that remains to be answered is if and how REM sleep influences glymphatic flow. We did not here identify a correlation between REM sleep and glymphatic influx or clearance. However, REM sleep is an inherent part of the sleep microstructure, and it is possible that REM sleep contributes to glymphatic function by measures we were not able to detect.

The negative effects of the sleep aid, zolpidem, on NE oscillations and glymphatic flow

Zolpidem (Ambien) is a high-affinity positive modulator of GABAA receptors, that enhances GABAergic transmission by binding to the alpha1 subunit91. Zolpidem is one of the most commonly prescribed sleep aids and our analysis clearly showed that zolpidem dampened the power of the NE oscillations and reduced glymphatic CSF tracer inflow (Figure 6). A key difference between natural and pharmacologically supported sleep is that boosting of inhibitory transmission dramatically alters the microarchitecture of sleep, possibly by direct suppression of LC activity, and thereby the NE oscillations characteristic of NREM sleep. The result is suppression of glymphatic flow compared with natural sleep. In the clinic, zolpidem has previously been shown to increase the risk of reversible dementia and has also been linked to neuropsychiatric adverse events92. Prescription of zolpidem is currently not recommended for individuals older than 65 by the American Geriatric Society93,94. Other studies reported divergent observations with regard to the effects of zolpidem on EEG sigma power, micro-arousals and consolidation of memory67,68,95,96. Since most of the above mentioned studies are based on polysomnographic studies of patients suffering from various conditions, including sleep apnea, insomnia or dementia, it is difficult to decipher whether zolpidem also suppresses NE dynamics in human subjects. Yet, our study clearly indicates that zolpidem reduced the latency to sleep, concurrently with potently interfering with the normal sleep architecture and suppressing glymphatic flow in mice. Sleep aids are therefore an unlikely tool for improving glymphatic function consistent with the general concept that these drugs are associated with considerable adverse effects and an increased risk of early mortality97.

Using fiber photometry to study brain fluid dynamics

To interrogate NE, vascular and CSF volume dynamics in natural sleep, we here developed a new methodology for recording real-time blood and CSF dynamics in unrestrained mice: flow fiber photometry. Most prior studies looking at vascular dynamics have used two-photon imaging in head-fixed mice31,47,98, whereas measurements of CSF dynamics have proven more difficult and have mostly been restricted to experiments in awake and anesthetized mice24. Since it is difficult to control when rodents enter natural sleep, anesthesia is commonly used as a proxy for sleep1,24,99,100. To be able to measure local changes in blood and CSF dynamics in non-restricted, non-anesthetized mice, we used a fiber optic cannula implanted in the brain in combination with permanent labeling of the vascular compartment by expression of fluorescently-tagged albumin. This approach allowed detection of fast fluctuations in local blood- and CSF signal across hours in freely behaving mice. Furthermore, flow fiber photometry enables recordings from deep brain tissues and combined monitoring of blood and CSF dynamics using virally-delivered biosensors45,101–104. Changes in hemoglobin content and pH around the fiber optic cannula can induce artefacts in the fluorescent signal56. For this study, we therefore chose a red-shifted CSF tracer to minimize confounding effects of these artifacts56. Additionally, recordings of control mice expressing the mutated GRAB sensor GRABNEmut, or mCherry, and analysis of auto-fluorescence in the CSF tracer channel prior to the tracer injection showed that the contribution of hemoglobin artifacts to the signals during NREM sleep were minor (up to ~7%) (Figure S1I–H and Figure S2).

Translational aspects

Multiple studies have proven the existence of a glymphatic system in humans10,16,105–107. Likewise, the infraslow oscillatory dynamics in sleep spindle activity are conserved across rodent and human NREM sleep108,109, and slow vasomotion is present in human sleep29. Also, the pupil size, which is controlled by NE110 exhibit fluctuations that are anticorrelated with sleep spindles in the same frequency range in humans111. Interestingly, a slightly faster 0.05 Hz oscillation in CSF flow was observed in the 4th ventricle of human subjects while sleeping in an MR scanner17 and was temporally directly correlated with autonomic arousals42. This view lends support to our observations that directly links NE release to slow vasomotion and CSF flow. An important goal for future studies will be to confirm the relationship between NE release and brain solute clearance in humans, and assess how compromised sleep and stiffening of the cerebral vasculature affect brain clearance in aging and disease states.

Conclusion

In summary, our findings point to a key role for NE-driven infraslow arterial oscillations in promoting glymphatic fluid transport and brain clearance in sleep. Additionally, the sleep aid zolpidem impaired the NE dynamics that characterize normal restorative sleep resulting in reduced glymphatic flow.

Method details

Animals

Wildtype C57BL/6 males and females were acquired from Janvier Labs at 8 weeks of age. For optogenetic stimulation of smooth muscle cells, male and female Sm22-Cre:Ai32-ChR2 mice and Sm22-Cre−/−:Ai32-ChR2 mice43 were used. For optogenetic activation and inhibition of the LC, heterozygous TH::Cre mice bred on a C57BL/6 background were used. Animals were housed with unlimited access to food and water in a regular 12-h light/dark cycle. Experiments were performed when animals were 13–16 weeks old and weighed 22–35 grams at the time of surgery. All experiments were performed during the light phase. All experiments were approved by the Danish Animal Experiments Inspectorate and were overseen by the University of Copenhagen Institutional Animal Care and Use Committee (IACUC), in compliance with the European Communities Council Directive of 22 September 2010 (2010/63/EU) legislation governing the protection of animals used for scientific purposes. Care was taken to minimize the number of animals included in the study.

Surgeries

All surgeries were performed in accordance with institutional guidelines and by experienced practitioners. For all surgical procedures, mice were anaesthetized with isoflurane and placed on a heating pad, and carprofen (5 mg/kg) and buprenorphine (0.05 mg/kg) were injected subcutaneously s.c., and lidocaine (1 mg/ml) was injected locally at the surgical site. After confirming lack of pain reflexes, the neck region was shaved and cleaned with ethanol and iodine. Following surgeries, all implants were fixed to the skull with dental glue (Panavia SA Cement Plus, Kuraray, America) and dental dement (Elstrøm Dental, Esbjerg, Denmark). Carprofen was injected s.c. 24 and 48 hours post-surgery to manage post-surgical pain. Full published protocol for fiber photometry surgery and recordings available46.

EEG implantation

Three burr holes for EEG were drilled in the skull with a handheld electrical drill (Tech2000, RAM Microtorque 45,000 rpm) over the left frontal cortex contralateral to the fiber implant, the right parietal cortex, and over the cerebellum, which served as the EEG reference. 0.8 mm low impedance stainless steel screws (NeuroTek, Toronto, Canada) were screwed into the burr holes and two silver wires (W3 Wires International) were inserted into the trapezius muscle serving as an EMG electrode.

Virus injection

AAV9-hSyn-GRABNE2m under the neuronal hSyn promoter (provided by Yulong Li, Peking University) was used to record NE fluctuations. The virus was injected with a nano injector pump (World Precision Instruments, USA) mounted onto a MP-255 manipulator, prior to the fiber optic cannula at the following coordinates relative to bregma: dorsal cortex: M/L: −3.0 mm, A/P: −1.7 mm, D/V: −1.2 mm, −1.35 mm and −1.5mm, mPFC: M/L −0.3 mm, A/P +1.7 mm, and D/V −2.00 mm, −2.25 mm, −2.50 mm and −2.75 mm. For optogenetic stimulation of the LC, ssAAV5/2-hEF1a-dlox-hChR2(H134R)-eYFP(rev)-dlox-WPRE-hGHp(A) was injected bilaterally in the LC at M/L ±0.9 mm, A/P −5.5 mm and D/V −3.75 mm. Virus was infused at 100 nl/min, and the needle was left in place for an additional 7 minutes and then slowly withdrawn. The dorsal cortex was chosen for concurrent NE and blood albumin recordings in order to place the probe in close proximity to the penetrating arteries arising from the middle cerebral artery. For control experiments, AAV9-CBh-mCherry (provided by Ayumu Konno, Gunma University) and pAAV-hSyn-GRAB_NEmut was used. Virus injections were performed at least 3 weeks prior to experiments to allow time for proper expression.

Albumin labelling

To visualize changes in parenchymal blood content, we the used the albumin probe AAV8/P3-Alb-mNeonGreen (Alb-mNG) and AAV8/P3-Alb-mScarlet (Alb-mSc) that guides the expression of mNeonGreen or mScarlet in albumin secreted by liver hepatocytes for chronic visualization of blood albumin44. Alb-mNG (6×10^11vg in 0.1 ml saline) or Alb-mSc (6×10^11vg in 0.1 ml saline) was delivered by I.P. injection at the end of the surgery. For a subset of mice, albumin expression was obtained by using alb-mScarlet-ST003 KI mice genetically modified to express fluorescent albumin112. The virus injection was performed at least 3 weeks prior to experiments to allow time for proper expression.

construct Provider Cat#
AAV9-hSyn-GRABNE2m WZ Biosciences YL003008-AV9
pAAV-hSyn-GRAB_NEmut Addgene 123310-AAVrg
AAV9-CBh-mCherry Ayumu Konno
AAV8/P3-Alb-mNeonGreen Hajime Hirase
AAV8/P3-Alb-mScarlet Hajime Hirase
ssAAV5/2-hEF1a-dlox-hChR2(H134R)-eYFP(rev)-dlox-WPRE-hGHp(A) Zurich Vector Core v214-5
ssAAV-5/2-mTH-iCre-WPRE-bGHp(A) Zurich Vector Core v659-5
ssAAV-5/2-shortCAG-dlox-ArchT-eGFP-dlox-WPRE-SV40p(A) Zurich Vector Core 461-5
Fiber-optic cannula implantation

A burr hole was drilled in the skull and a mono fiber-optic cannula (400 μm, 0.48 NA, Doric Lenses) attached to a 2.5 mm diameter metal ferrule was implanted according to stereotaxic coordinates relative to bregma (ventral cortex: M/L −1.7 mm, A/P +1.7 mm, D/V +3.8 mm, dorsal cortex: M/L: −3.0 mm, A/P: −1.7 mm, D/V: −1.3 mm, mPFC: M/L −0.3 mm, A/P +1.7 mm, D/V −2.5 mm). For optogenetic LC stimulation, a dual fiberoptic cannula (200 μm, 0.22 NA, Doric Lenses) were implanted above LC (M/L ±0.9 mm, A/P −5.5 mm, D/V −3.65 mm). For testing glymphatic influx after probe implantation, a stainless steel dummy probe (Plastics One, Bilaney) was implanted at the same ventral cortex coordinates.

Striatal probe and head plate implantation

For efflux experiments, a burr hole was drilled above the striatum and a stainless steel cannula (Plastics One, Bilaney) was placed according to stereotaxic coordinates relative to bregma (A/P 0.6 mm, M/L −2 mm, D/V −3.25 mm). A custom-made headplate for fixation in the SPECT scanner was fitted around the implants following implantation.

Miniscope surgery

For miniscope imaging of the cortical vasculature, the placement of the miniscope was centered above the middle cerebral artery where AAV9-hSyn-GRABNE2m was injected at two different depths posterior to the cranial window in an angled position to increase virus delivery underneath the cranial window. A round craniotomy of 4 mm diameter was made over the parietal cortex using a handheld electrical drill (Tech200, RAM Microtorque), covered with a sterile glass coverslip (circular, MINI, 0.17 mm thick, 4 mm diameter) and sealed with a mix of super glue (precision, Loctite) and dental cement powder (Paladur, Kulzer). For GRIN lens experiments, no virus was injected, but a GRIN lens (1 mm diameter, Inscopix) was implanted at the stereotaxic coordinates relative to bregma M/L −1.7 mm, A/P +1.7 mm, D/V +3.8 mm and sealed with super glue. A miniature fluorescent microscope (miniscope V4.4, Open Ephys) connected to a baseplate (Variant 2, Open Ephys) was placed in a stereotactic frame and placed above the cranial window or GRIN lens while live recording was used to guide optimal placement and distance and height. The baseplate was then fixed to the skull with dental cement (Sun Medical, Super Bond, C&B). When the cement was dry, the miniscope was carefully unscrewed and raised out of the baseplate covered by a protective cap (Open Ephys).

Cisterna magna cannulation

Two days prior to the tracer infusion experiment, mice were anaesthetized with isoflurane and placed on a heating pad. Carprofen (5 mg/kg) and buprenorphine (0.05 mg/kg) were injected s.c. and lidocaine (1 mg/ml) was injected locally in the neck region. After confirming lack of pain reflexes, animals were placed in a stereotaxic frame with the neck slightly flexed (30–40°), the neck region was shaved and cleaned with ethanol and iodine, and a small incision (~0.5 cm) was made to expose the atlanto-occipital membrane and the cisterna magna. A cisterna magna catheter was made by connecting the tip of a 30-gauge needle to a 3 cm long piece of PE10 tubing (Scandidact) that was filled with artificial CSF and sealed. The needle tip was then carefully placed in the cisterna magna by first puncturing the atlanto-occipital membrane where the area between the cerebellum and brain stem leaves most space underneath the membrane, and then inserting the needle so only the open end of the tip was inside the cisterna magna. The catheter was fixed with cyanoacrylate glue (Loctite) and cured with glue accelerator followed by application of dental cement. Carprofen was injected s.c. 24 hours post-surgery. Full published protocol for cisterna magna cannulation and tracer infusion available52.

Intracisternal tracer infusion

Two days after the cisterna magna cannulation, a PE10 tubing filled with tracer was connected to the cisterna magna catheter. 10 μl CSF tracer was slowly infused into the cisterna magna (infusion rates were 1 μl/min for slice influx studies and 0.5 μl/min for fiber photometry studies) in freely behaving mice. For the experiment testing glymphatic influx after probe implantation, mice were left undisturbed in their home cage for 30 minutes following the tracer infusion before the brain was dissected and dropfixed in 4% paraformaldehyde at 4°C overnight for later slicing and analysis. For the experiment correlating tracer influx with sleep measures, EEG and EMG was recorded during and after the tracer infusion where mice were left undisturbed in their home cage for 30 minutes or kept awake by continuously presenting the mice to novel objects. A separate group of mice were sleep deprived 4 hours prior to the tracer infusion using novel objects and allowed to sleep during the tracer infusion and for the next 30 minutes until the brain was dissected. For zolpidem experiments, the mice received an i.p. injection of either 5 mg/kg zolpidem previously dissolved in miliQ and Tween, or a similar volume of miliQ as control 15 minutes prior to the tracer injection. The pump was started 15 minutes after the injection of zolpidem or miliQ, or when mice injected with miliQ first transitioned into sleep (on average this occurred 13.29 minutes after the injection). All injections were done in the beginning of the light phase to ensure stable, natural sleep. 30 minutes after the end of the tracer injection, the mice were decapitated and the brain was dissected and drop-fixed in 4% paraformaldehyde at 4°C overnight. For fiber photometry experiments, 2% 3 kDa tetramethylrhodamine dextran in aCSF was used in mice expressing P3-alb-mNeonGreen, and 2% 3kDa FITC dextran in aCSF was used in a subset of mice expressing P3-alb-mScarlet. After the end of the infusion, the tubing was cut and sealed to prevent backflow. For infusion of i.v. tracer, 0.2 ml tracer was injected into the tail vein and the mouse was subsequently returned to the recording cage for EEG and fiber photometry recordings. The tracers used for cisterna magna injection and i.v. delivery were:

Tracer Delivery route Company Cat#
2% 3 kDa tetramethyl-rhodamine dextran in aCSF Cisterna magna Thermo Fischer D3308
2% 3 kDa FITC dextran in aCSF Cisterna magna Thermo Fischer D3306
99mTc-labeled DTPA (489 Da) Striatum Curium Pharma -
Bovine serum albumin (BSA) Alexa Fluor 594 I.V. Thermo Fischer A13101
2.5% 70 kDa tetramethylrhodamine dextran in saline I.V. Invitrogen D1818

Drug preparation

Zolpidem pills (Actavis) were crushed and dissolved in 1 ml Tween 20 (Sigma) under constant stirring at 60°C for 1 hour. Sterile miliQ water was then added for a final concentration of 10 or 5 mg/ml and stirred at 60°C for another hour. The solution was stored in the fridge and not used for more than 3 days. For the marble burying test, mice received 5 mg/kg or 10 mg/kg i.p. For all other experiments, mice received 5 mg/kg i.p.

The noradrenergic receptor inhibitors/antagonist cocktail (PPA) was mixed in saline and DMSO the same day of the experiment in the following concentrations: prazosin hydrochloride (10 μg per gram, P7791, Sigma-Aldrich), propranolol hydrochloride (10 μg per gram, P8688, Sigma-Aldrich), and atipamezole (1 μg per gram, A9611, Sigma-Aldrich).

Glymphatic slice imaging and analysis

Following brain dissection, the brain was drop-fixed in 4% paraformaldehyde at 4 °C overnight. Brains were cut in 100 μm-thick coronal slices on a vibratome (VT1200S, Leica Biosystems), and 5 brain sections spaced evenly across the anterior-posterior axis were incubated for 5 minutes with 4′,6-diamidin-2-phenylindol (DAPI, Thermo Fischer Scientific) diluted in PBS (1/100). Brain sections were then mounted to glass slides with mounting medium (Prolong Antifade Gold), coverslipped, and imaged on a Nikon Eclipse NI-E epifluorescence microscope using NIS Elements software. Multi-channel whole slice montages were generated at 4x magnification with emission filters for DAPI and Fluorescein isothiocyanate (FITC) or far red. Mean pixel intensities were calculated using ImageJ software. For comparison of hemispheres, ROIs in each hemisphere were drawn and the mean pixel intensity was calculated and averaged across sections.

Sleep recordings

For fiber photometry, miniscope, and influx studies, mice were placed in circular recording cages (ViewPoint Behavior Technology) with unlimited access to food and water, and cables were connected to the EEG and EMG electrodes and to a commutator (Plastics One, Bilaney, SL12C). Mice were allowed to habituate to the recording cage and cables for at least one day prior to recordings. On the day of fiber photometry or miniscope recordings, mice were connected to a fiber optic implant or a miniscope, which were synchronized with EEG, EMG, and video recordings via TTL pules, and recorded continuously. EEG and EMG signals were amplified (National Instruments Inc., 16-channel AC amplifier Model 3500) and filtered (EEG signal: high-pass at 1 Hz and low-pass at 100 Hz; EMG signal: high-pass at 10 Hz and low-pass at 100 Hz), and a notch filter of 50 Hz was used to reduce power line noise. Signals were then digitized using a Multifunction I/O DAQ Device (National Instrument, USB-6343) and sampled at a sampling rate of 512 Hz. Video was recorded continuously using an infrared camera (Flir Systems) and used later to aid in the scoring of vigilance states. Sleep scoring was performed manually by visual inspection of EEG and EMG traces divided into 4-second bins using SleepScore software (ViewPoint Behavior Technology). For analysis of the average NE, blood and CSF trace during micro-arousals, NREM periods were scored in 2 second bins to increase temporal resolution. Vigilance states were defined as wake (high muscle tonus and a high frequency, low amplitude EEG), NREM sleep (no muscle tonus and low frequency, high amplitude EEG,), and REM sleep (no muscle tonus and high frequency, low amplitude EEG). Micro-arousals were defined as wake bouts during NREM sleep with a duration of less than 20 seconds. For plotting purposes, some figures only show micro-arousals of 1–10 seconds (stated in the corresponding text). For sleep scoring in 4 second bins, a bin would be scored as wakefulness if at least 1 second out of the 4-second bin consisted of wake-like EEG and increased muscle activity. EEG power within different power bands (delta power (1–4 Hz), theta power (4–8 Hz), sigma power (8–15 Hz), beta power (13–20 Hz)) was calculated as the percentage out of the total power spectrum from 1–30 Hz. For visualization purposes, some analysis only included micro-arousals of a certain duration.

For SPECT experiments, EEG and EMG cables were connected to a 32-channel head stage (Intan Technologies) connected to an acquisition board (Open Ephys). EEG and EMG were recorded using the Open Ephys Gui113 at a sampling rate of 1250 Hz. Sleep scoring was performed by visual inspection of EEG and EMG in 5-second bins using the Wonambi Python package, v7.06 (https://wonambi-python.github.io) using the same scoring criteria as above. Data analysis was performed in MATLAB using custom-made scripts.

Fiber photometry recordings

Fiber photometry experiments were performed at least 2–3 weeks following fiber optic cannula implantation and virus injection to allow time for recovery and virus expression. We used a RZ5 or RZ10-X Lux-I/O Processor (Tucker Davis Technologies) with integrated LED drivers to control integrated excitation LEDs (465 nm and 560 nm, LUX LEDs, Tucker Davis Technologies). 465 nm and 560 nm excitation light was integrated using a minicube (Doric Lenses) and delivered through the same patch cord to excite fluorescent albumin and CSF tracer. A fiber-optic patch cord (400 μm core, NA = 0.48, Doric Lenses) provided a light path to the animals and Zirconia sleeves were used to attach fiber-optic patch cords to fiber implants on the animal. The fiber-optic signals were collected using integrated LUX photosensors (Tucker Davis Technologies) and independently recovered using standard synchronous demodulation techniques implemented on the RZ10-X real-time processor with a sampling rate of 1000 Hz. Synapse software (Tucker-Davis Technologies) was used to control the signal processor and align fluorescent signals with video and EEG/EMG signals through TTL pulses. Excitation LEDs were bleached for 1 hour prior to recordings using the Synapse software.

Miniscope recordings

Over three days prior to experiment, mice habituated to wear the miniscope using a 3D-printed dummy of similar weight (3.1 g). On the day of recording, the miniscope was mounted on the head of the mouse and connected to a DAQ box (V3.3, Open Ephys) via a thin, flexible 50 Ohm coaxial cable (Open Ephys) that was further connected to a PC for power, communication, and data transmission. Recordings were controlled by DAQ software supplied by the UCLA miniscope project. Images were acquired with 30 frames per second and recorded into uncompressed .avi files. While the mouse was left undisturbed in its home cage, 4 recordings of 30 min duration were acquired. A 15 min break was placed in between recordings where the miniscope was turned off to minimize the risk of damaging the cortical tissue from heat produced by the LED light. For GRIN lens imaging experiments, a cannula was implanted in the cisterna magna as described above. 2 days after, a subset of mice were injected i.v. with 0.1 ml 3 kDa FITC dextran to visualize the vasculature and left undisturbed for at least 1 hour until the tracer had diminished from the blood. All mice had then 10 μl of the same tracer infused with 1 μl/minute into the cisterna magna. Following the tracer infusion, miniscope images were acquired every 30 minutes the next 7 hours to visualize tracer influx and clearance.

Optogenetic LC inhibition

TH-Cre transgenic mice were injected with GRABNE2m in the mPFC, injected with AAV5/2 encoding floxed ArchT-eGFP bilaterally in the LC, implanted with a mono fiber-optic cannula in the mPFC and a dual fiberoptic cannula in the LC, as well as electrodes for EEG and EMG as described above. AAV-8/P3-Alb-mScarlet was injected retro-orbitally unilaterally for vascular recordings. A 532-nm laser (SLOC Lasers, Changchun New Industries Optoelectronics Technology Co. Ltd., model 16030476) was used to generate stimulations (5 mW at the tip of each fiber) bilaterally in LC simultaneously with mPFC fiber photometry recordings and EEG and EMG measurements. Mice were left undisturbed in EEG recording chambers during the light phase. The sessions lasted 3 to 5 hours and were recorded between 9 am and 7 pm. The laser stimulations were generated based on real time ΔF/F (%) calculations of NE levels that fell below a predetermined threshold of −5 and lasted 2 minutes followed by a 4 minute period where the laser could not be triggered. Only laser stimulations that were initiated during NREM sleep were selected for subsequent analysis.

Optogenetic LC stimulation

TH-Cre transgenic mice were injected with GRABNE2m in the mPFC, injected with AAV5/2 encoding floxed hChR2-eYFP bilaterally in the LC, implanted with a mono fiber-optic cannula in the mPFC and a dual fiberoptic cannula in the LC, as well as electrodes for EEG and EMG as described above. On the day of recordings, mice were either injected i.v. with 0.1 ml BSA Alexa Fluor 594 to record vascular dynamics or injected with 10 μl 3 kDa tetramethylrhodamine dextran in the cisterna magna to record CSF dynamics. After confirmation of sleep by inspection of the EEG and EMG, the optogenetic stimulation paradigm controlled by Synapse software (Tucker-Davis Technologies) was started. A 430–490-nm laser (Shanghai Laser & Optics Century Co. Ltd., model BL473–200FC) was used to generate 1-second stimulations (10 mW) of increasing frequency (5, 10 and 20 Hz) every 30 seconds bilaterally in the LC. EEG, EMG, GRABNE2m and red fluorescence from either the vascular or CSF tracer was recorded simultaneously. For baseline recordings, 2 × 20 stimulations with alternating stimulation frequencies and a 10 minutes break in between the two stimulation trains were performed. For LC stimulations after pharmacological inhibition of NE receptors, 1 × 20 stimulations with 20 Hz was used.

Optogenetic arterial constriction

Sm22-Cre:Ai32-ChR2 and Sm22-Cre−/−:Ai32-ChR2 mice were implanted with EEG and EMG electrodes and a fiber optic cannula in the dorsal cortex as described above. Two weeks after the surgery, a subset of Sm22-Cre:Ai32-ChR2 mice were used to assess the optimal stimulation parameters. The mice were connected to the EEG and fiber photometry acquisition cables and received an i.v. injection of BSA Alexa Fluor 594 to visualize blood dynamics via the fiber optic cannula. Optogenetic stimulation was delivered via the same cannula with varying amplitudes and durations controlled by Synapse software (Tucker-Davis Technologies) while fiber photometry and EEG/EMG was acquired. To define the optimal stimulation settings, blood tracer dynamics during natural micro-arousals scored during periods of undisturbed sleep in between the optogentic stimulation trains were compared to the blood tracer dynamics elicited by optogenetic stimulation. A week later, mice were implanted with a chronic catheter in the cisterna magna as described above and placed in cages for EEG/EMG and fiber photometry acquisition. Two days after the catheter implantation, the mice were connected to cables for EEG/EMG and fiber photometry and a PE10 tubing filled with 3 kDa tetramethylrhodamine dextran was connected to the cisternal catheter as described above and placed back in the cage. When the mouse entered sleep, 10 μl tracer was injected into the CSF with 1 μl/minute via a long tubing that allowed unhindered movement. At the same time, optogenetic stimulation with blue light at an amplitude of 1 was delivered via the fiber optic cannula (470 nm, stimulation trains with 10 Hz (50 ms) for 3 seconds at 10 seconds intervals for a total of 60 minutes). One hour after the beginning of the tracer infusion, the brain was dissected and dropfixed in 4% paraformaldehyde at 4°C overnight for later slicing and analysis as described above. All experiments were performed during the light period from Zeitgeber 2–6.

SPECT/CT acquisition

Mice with EEG/EMG electrodes and a striatal cannula were placed in the scanner bed and fixed using a custom-build fixation system that allowed a 35 degrees flex of the head to obtain a more natural position. A VECTor4CT (MILabs) system with a high energy ultra-high resolution (voxel size: 0.8 × 0.8 × 0.8 mm) rat clustered multi-pinhole collimator (HE-UHR-RM, 1.8mm pinhole diameter) was used for both CT and SPECT acquisition. A 100 μL Hamilton microsyringe (Sigma Aldrich) in an micro infusion pump was used to deliver 1 μL 99mTc-labeled diethylenetriaminepentaacetic acid (12.5 mg/ml, TechneScan DTPA, Curium Pharma; 489 Da) into the striatum via the striatal cannula at a controlled rate of 0.1 μl/min. Immediately following the tracer infusion, SPECT was acquired as 1 frame of 15 minutes covering the full body of the mouse (11 positions) with detection peak energy of 1200 keV. A full-body CT scan was performed after the SPECT acquisition. The full-body CT scan was acquired with 50 kV tube voltage, 20 ms exposure time, x22 binning and 360 projections over 40 seconds. Scatter and CT-based non-uniform attenuation correction were performed, and the images were reconstructed using a Similarity-Regulated Ordered Subsets Estimation Maximization (SROSEM) with a voxel size of 0.6 mm and 5 iterations. A 0.8 FWHM (mm) gaussian filter was added post reconstruction. SPECT images were reconstructed with a photopeak window centered around 140 keV with 20% width. All injected doses and scans were decay corrected to a reference time point and quantified. Analysis of SPECT images were performed with ITK snap114 where 3D segmentations were drawn manually on a reference CT image that all animals were registered to.

Marble burying test

Mice received vehicle, 1 mg/kg zolpidem or 5 mg/kg zolpidem and were 15 minutes after placed in a container with 5 cm depth of sawdust bedding and 21 marbles placed on the bedding. After 15 minutes in the container, the mouse was placed back in its home cage and the activity of the mouse was quantified as the number of marbles that had been partly or fully buried. The points for buried marbles were given such that a marble on top of the bedding gave 1 point, a marble partly buried by bedding gave 2 points and a marble completely buried by bedding gave 3 points. The test was repeated the following day to test if the effect of the drug had worn off.

Microdialysis

Mice were anaesthetized with isoflurane and placed on a heating pad, and carprofen (5 mg/kg) was injected subcutaneously and lidocaine (1 mg/ml) was injected locally at the surgical site. After confirming lack of pain reflexes, the neck region was shaved and cleaned with ethanol and iodine. An incision was made on the scalp between the ears, and the skull was cleaned where after a small hole was drilled in the skull above the prefrontal cortex (M/L: 0.50, A/P: 2.00, D/V: −1.00) using a handheld electrical drill (Tech2000, RAM Microtorque 45,000 rpm). Subsequently, a CMA/7 guide cannula with a dummy (CMA/Microdialysis, Stockholm, Sweden) was inserted and dental cement (Dentalon Plus, Heraeus, Germany) was applied to cover the cannula. Mice were allowed to recover for 48 hours before the experiment. On the day of the experiment, the guide cannula with dummy was removed and replaced with a CMA/7 6 kDa microdialysis probe with a 2 mm membrane (CMA/Microdialysis, Stockholm, Sweden). The microdialysis probe was connected to a microdialysis syringe pump (CMA 402 Microdialysis Syringe Pump, Harvard Apparatus, United States) with 1 ml syringes aCSF. For the first 2 hours after probe placement, the mice were allowed to recover, and the probe was flushed at a flow rate of 1.2 μl/min. After this, the flow rate was maintained at 0.5 μl/min, and samples were obtained every 20 min. The first 20 minutes (2 samples) mice were left undisturbed to establish baseline values before drug treatment. The mice then either received an i.p. injection of zolpidem (5 mg/kg) or a similar volume of saline while microdialysis samples were continuously collected for 3 hours. After end study the mice were sacrificed, and the brain dissected to confirm correct probe placement. The levels of NE, were determined by HPLC with electrochemical detection. The HPLC EC system consisted of a HPLC pump (LC-10AD Shimadzu Europa GmbH), a LC-27A degasser (BASJ, Tokyo, Japan), a refrigerated Autosampler (Shimadzu Europa GmbH), an amperometric detector (Antec Decade from Antec, Leiden, Netherlands), and a computerized data acquisition system (LC solution, Shimadzu Europa GmbH). The electrochemical detector cell was equipped with a glassy carbon electrode operating at +0,7V vs. Ag/AgCl reference electrode. Typically, 10 μl samples were injected onto a Prodigy C18 column (100×2 mm I.D., 3- m particle size, Phenomnex, Torrance, California). The mobile phase consisted of 55 mM sodium acetate, 1 mM octanesulfonic acid, 0.1 mM Na2EDTA, and 8% Acetonitrile, adjusted to pH 3.2 with 0.1 M acetic acid. The flow rate was 0.15 ml/minute and the injection volume was 10 μL. The limits of detection (at signal-to-noise-ratio 3) for NE, concentrations were 12 fmol/10 μl.

Fiber photometry signal analysis

Files were analyzed with custom-made scripts in MATLAB R2020a (MathWorks). Fiber photometry traces were down sampled 100 times and filtered using the “filtfilt” function in Matlab prior to analysis. Fiber photometry signals used for calculating relative signal levels and cross-correlations were furthermore detrended prior to the analysis by subtraction of the same signal that had been smoothed using a moving average created with the “conv” function in Matlab. All analysis of CSF tracer signal was performed on both the influx and clearance part of the trace, except the average CSF trace during micro-arousals which was performed on the non-detrended CSF signal during the clearance phase only. ΔF/F calculations were generated by using the median of 10 minutes of baseline recording prior to the tracer infusion or the median of the first 10 minutes if the experiment did not include tracer infusion. For the optogenetic stimulation experiments, the median of 5 minutes prior to the beginning of the tracer infusion was used. The percentage change (ΔF) from the median (F) was then calculated as:

ΔF/F(%)=((signal–median)/median)*100;

The transition plots were computed over the relevant combinations of the different states: awake-NREM, NREM-awake, NREM-REM, REM-NREM. To be included in the analysis, the length of each state before and after the transitions had to be at least 100 seconds (40 seconds in the case of REM), allowing 20 seconds of intruding states. The signal was filtered using a second order high pass Butterworth filter with a 5×10−4 cut-off frequency prior to plotting. After that, the signal was normalized by dividing it with the maximum value. To calculate the relative levels of CSF tracer and blood albumin across different states, the signals were detrended and divided into segments of awake, NREM or REM, and only segments lasting at least 100 seconds were used. The mean of each state segment was calculated and the mean for each mouse was calculated from the overall mean of each segment. Cross correlations with fiber photometry data from NE trace, CSF tracer signal and blood albumin signal were calculated with detrended fiber photometry traces during periods of wakefulness or NREM sleep lasting at least 100 seconds and periods of REM sleep lasting at least 30 seconds. The average cross correlation within a specific state was generated for each mouse by averaging cross correlations computed for all periods of each state. The lag axis of the cross correlations have been inverted to show actual time instead of lag. EEG power within different power bands (delta power (1–4 Hz), theta power (4–8 Hz), sigma power (8–15 Hz), beta power (13–20 Hz)) was calculated from spectrograms of the whole EEG trace and interpolated to fit the length of the CSF and albumin traces. Average power spectral density (PSD) plots for fiber photometry signals during wakefulness, NREM and REM sleep was generated using the “pwelch” function in Matlab after application of a highpass filter of 0.005. Only sustained periods of wakefulness or NREM sleep lasting more than 300 seconds (including micro-arousals) and sustained periods of REM sleep lasting more than 100 seconds were included in the PSD analysis. For PSD plots of fiber photometry traces showing wakefulness, NREM sleep and REM sleep in the same plot, the values were normalized by division with the area under the curve from 0–0.03 Hz. For visualization of NE, albumin and CSF tracer signal during sigma power peaks, the “findpeaks” function in Matlab was used to detect all peaks in the sigma power trace after smoothing using the “smoothdata” function. The time stamp of the sigma power peaks were saved and the NE, albumin and CSF trace during the same time stamps were averaged and plotted. Mice with excessive noise on the EEG signal were excluded from EEG power analyses. For analysis of fiber photometry signals during micro-arousals in natural sleep, all micro-arousals lasting 1–10 seconds and with at least 40 seconds of NREM sleep before and after the micro-arousal were included. Fiber photometry traces 30 seconds before and after the micro-arousal were stored, normalized by subtraction of the first 20 seconds of the trace and averaged for each mouse.

Miniscope analysis

Quantification of blood vessel diameter were performed in Fiji/ImageJ using an open-source DIAMETER plug-in115. Based on a linear ROI manually selected across the vessel by the operator, 5 measurements (i.e., 1 line and 2 parallel shifts in both directions) were taken throughout the image stacks. Likewise, Fiji/ImageJ was used to measure NE signal as the mean grey value within a circular ROI, drawn within the brain parenchyma containing no visible blood vessels and throughout image stacks. Results were saved as .txt files and the data analysis were subsequently performed in MATLAB using custom-written code. The vessel diameter signal was created by taking the median across the 5 line-measurements extracted from the DIAMETER plug-in. A 15- to 35-order one-dimensional median filter was applied to remove artifactual spikes from the raw traces. To normalize vessel diameters across mice, the relative means within each state were converted into changes in signal from periods of quite wake (events with small but negligible head movements or posture changes in absence of locomotion manually identified using video recordings). The percentage change in diameter (ΔD) from the mean diameter of periods of quiet wakefulness (D) was then calculated as:

ΔD/D(%)=((diameter–meanquietwakediameter)/meanquietwakediameter)*100;

For comparison of mean vessel diameter between brain states, only events >20 seconds in duration were considered while intruding events lasting <10 seconds were excluded in the analysis. Cross-correlations between vessel diameter, NE level, and EEG power bands were conducted in MATLAB on awake and NREM events lasting >50 seconds with a time lag of 25 seconds, and REM events lasting >20 seconds with a time lag of 10 seconds. Analysis of tracer inflow and clearance from the GRIN lens recordings was performed in Fiji/ImageJ by placing a circular ROI over the field of view and calculating the mean pixel intensity.

Assessment of fiber photometry hemoglobin absorption

To investigate the effect of hemoglobin absorption56 on the fiber photometry recordings of CSF tracer, red fluorescence was recorded from mice expressing AAV9-CBh-mCherry and green fluorescence was recorded from mice expressing pAAV-hSyn-GRABNEmut. Additionally, fiber photometry recordings in the red channel before and after injection of a red-shifted CSF tracer was compared to assess the effect of hemoglobin fluctuations in the background fluorescence. All micro-arousals from 1–10 seconds were included in the analysis. mCherry, GRAB-mut fluorescence and background fluorescence before tracer injection was found to exhibit lower intensity during REM sleep, which is most likely caused by the vasodilation known to be associated with REM sleep. Thus, it is possible that some amount of hemoglobin absorption is affecting the CSF tracer trace during REM sleep and we therefore focused the study on NREM sleep. in NREM sleep, minor fluctuations in mCherry fluorescence were observed, but to a smaller extend and with a less pronounced waveform than the CSF tracer trace after CSF tracer injection. The GRAB-mut fluorescence and background fluorescence before tracer injection showed no fluctuations during NREM sleep or during micro-arousals. Thus, hemoglobin absorption may alter the CSF trace during NREM sleep, but it is not likely to be the main cause of the observed dynamics. Likewise, the anti-correlated nature of blood and CSF is not likely to be the result of hemoglobin absorption as this relationship has been established with MR imaging17,42.

Statistical analysis

Statistical analysis was performed using GraphPad Prism, version 7.0c for Mac OS X (GraphPad Software, La Jolla, CA). The data are presented as mean ± SD unless otherwise noted. The Shapiro–Wilk test was used to assess normality of data. Two-sided paired t-test or unpaired t-test was used to compare pairs of groups, if data passed the normality test, otherwise, the Wilcoxon matched-pairs signed-rank test was used. For statistical analysis of three means, one-way ANOVA with Geisser-Greenhouse correction and Tukey’s multiple comparison was used. For repeated measurements, two-way ANOVAs with Sidak’s post hoc test were used. For comparison of a group mean to normalized data, one-tailed Wilcoxon matched-pairs signed rank test was used. Graphs were generated using GraphPad Prism, version 7.0c and Adobe Illustrator CC 2019 (Adobe). Outliers were eliminated using ROUT’s test with Q=5. Effect sizes are calculated as Eta squared. For the glymphatic clearance study (Figure 5), mice that spent less than 75 minutes of the 5 hours (25% of the time) between scans in sleep were omitted from the analysis (1 mouse). For the glymphatic influx study (Figure S4), mice that spent less than 20 of the 30 minutes circulation time in sleep were omitted from the analysis (2 mice) in order to obtain enough sleep data. For all analysis of EEG power, mice were omitted if EEG power analysis could not be performed due to too noisy signals.

Supplementary Material

1

Highlights.

  • Norepinephrine release from the locus coeruleus drives slow vasomotion in NREM sleep

  • Infraslow norepinephrine oscillations dictate anti-correlated cycles of blood- and CSF volume changes

  • The frequency of norepinephrine oscillations during NREM sleep predicts glymphatic clearance

  • The sleep aid zolpidem suppresses norepinephrine oscillations and glymphatic flow

Acknowledgements

We would like to thank Dan Xue for expert graphical support, the Department of Clinical Physiology and Nuclear Medicine, Rigshospitalet, for providing us with [99mTc]-DTPA, Palle Koch for technical assistance with EEG recordings and SPECT imaging and Hashmat Ghanizada for help and guidance on the preparation of pan-adrenergic blockers. This work was supported by Lundbeck Foundation grant R386- 2021-165 (M.N.), 114955 (V.U.), Novo Nordisk Foundation grant NNF20OC0066419 (M.N.), NNF23OC0082427 (N.H.), NNFOC0058058 (H.H.), National Institutes of Health grant R01AT011439 (M.N.), National Institutes of Health grant U19NS128613 (M.N. and HH), US Army Research Office grant MURI W911NF1910280 (M.N.), Human Frontier Science Program grant RGP0036 (M.N.), the Dr. Miriam and Sheldon G. Adelson Medical Research Foundation (M.N.), Simons Foundation grant 811237 (M.N.), Danmarks Frie Forskningsfond 0134-00107B (H.H), 3101-00282B (M.N.), JPND/HBCI 1098-00030B (M.N.) and JPND/Good Vibes 2092-00006B (M.N.).

Footnotes

Declaration of interests

MN is a paid consultant of CNS2 for unrealted studies.

References

  • 1.Iliff JJ, Wang M, Liao Y, et al. A Paravascular Pathway Facilitates CSF Flow Through the Brain Parenchyma and the Clearance of Interstitial Solutes, Including Amyloid. Sci Transl Med. 2012;4(147):1–11. doi: 10.1126/scitranslmed.3003748 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Iliff JJ, Chen MJ, Plog BA, et al. Impairment of Glymphatic Pathway Function Promotes Tau Pathology after Traumatic Brain Injury. J Neurosci. 2014;34(49):16180–16193. doi: 10.1523/JNEUROSCI.3020-14.2014 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Ishida K, Yamada K, Nishiyama R, et al. Glymphatic system clears extracellular tau and protects from tau aggregation and neurodegeneration. J Exp Med. 2022;219(3):1–9. doi: 10.1084/jem.20211275 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Rasmussen MK, Mestre H, Nedergaard M. Fluid transport in the brain. Physiol Rev. 2022;102(2):1025–1151. doi: 10.1152/physrev.00031.2020 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Louveau A, Plog BA, Antila S, Alitalo K, Nedergaard M, Kipnis J. Understanding the functions and relationships of the glymphatic system and meningeal lymphatics. J Clin Invest. 2017;127(9):3210–3219. doi: 10.1172/JCI90603 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Louveau A, Herz J, Alme MN, et al. CNS lymphatic drainage and neuroinflammation are regulated by meningeal lymphatic vasculature. Nat Neurosci. 2018;21(10):1380–1391. doi: 10.1038/s41593-018-0227-9 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Kipnis J The anatomy of brainwashing. Science (80- ). 2024;385(6707):368–370. doi: 10.1126/science.adp1705 [DOI] [PubMed] [Google Scholar]
  • 8.Lundgaard I, Li B, Xie L, et al. Direct neuronal glucose uptake heralds activity-dependent increases in cerebral metabolism. Nat Commun. 2015;6(1):6807. doi: 10.1038/ncomms7807 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Kress BT, Iliff JJ, Xia M, et al. Impairment of paravascular clearance pathways in the aging brain. Ann Neurol. 2014;76(6):845–861. doi: 10.1002/ana.24271 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Zhou Y, Cai J, Zhang W, et al. Impairment of the Glymphatic Pathway and Putative Meningeal Lymphatic Vessels in the Aging Human. Ann Neurol. 2020;87(3):357–369. doi: 10.1002/ana.25670 [DOI] [PubMed] [Google Scholar]
  • 11.Liu G, Mestre H, Sweeney AM, et al. Direct Measurement of Cerebrospinal Fluid Production in Mice. Cell Rep. 2020;33(12):108524. doi: 10.1016/j.celrep.2020.108524 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Mestre H, Du T, Sweeney AM, et al. Cerebrospinal fluid influx drives acute ischemic tissue swelling. Science (80- ). 2020;367(6483):1198–1199. doi: 10.1126/science.aax7171 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Hussain R, Tithof J, Wang W, et al. Potentiating glymphatic drainage minimizes post-traumatic cerebral oedema. Nature. 2023;623(7989):992–1000. doi: 10.1038/s41586-023-06737-7 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Xie L, Kang H, Xu Q, et al. Sleep Drives Metabolite Clearance from the Adult Brain. Science (80- ). 2013;342(6156):373–377. doi: 10.1126/science.1241224 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Hauglund NL, Pavan C, Nedergaard M. Cleaning the sleeping brain – the potential restorative function of the glymphatic system. Curr Opin Physiol. 2020;15:1–6. doi: 10.1016/j.cophys.2019.10.020 [DOI] [Google Scholar]
  • 16.Eide PK, Vinje V, Pripp AH, Mardal K-A, Ringstad G. Sleep deprivation impairs molecular clearance from the human brain. Brain. 2021;144(3):863–874. doi: 10.1093/brain/awaa443 [DOI] [PubMed] [Google Scholar]
  • 17.Fultz NE, Bonmassar G, Setsompop K, et al. Coupled electrophysiological, hemodynamic, and cerebrospinal fluid oscillations in human sleep. Science (80- ). 2019;366(6465):628–631. doi: 10.1126/science.aax5440 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Shokri-Kojori E, Wang G-J, Wiers CE, et al. β-Amyloid accumulation in the human brain after one night of sleep deprivation. Proc Natl Acad Sci. 2018;115(17):4483–4488. doi: 10.1073/pnas.1721694115 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Miyakoshi LM, Stæger FF, Li Q, et al. The state of brain activity modulates cerebrospinal fluid transport. Prog Neurobiol. 2023;229(June):102512. doi: 10.1016/j.pneurobio.2023.102512 [DOI] [PubMed] [Google Scholar]
  • 20.Shi L, Chen S-J, Ma M-Y, et al. Sleep disturbances increase the risk of dementia: A systematic review and meta-analysis. Sleep Med Rev. 2018;40:4–16. doi: 10.1016/j.smrv.2017.06.010 [DOI] [PubMed] [Google Scholar]
  • 21.Sabia S, Fayosse A, Dumurgier J, et al. Association of sleep duration in middle and old age with incidence of dementia. Nat Commun. 2021;12(1):2289. doi: 10.1038/s41467-021-22354-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Yaffe K, Laffan AM, Harrison SL, et al. Sleep-Disordered Breathing, Hypoxia, and Risk of Mild Cognitive Impairment and Dementia in Older Women. JAMA. 2011;306(6):613–619. doi: 10.1001/jama.2011.1115 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Iliff JJ, Wang M, Zeppenfeld DM, et al. Cerebral Arterial Pulsation Drives Paravascular CSF-Interstitial Fluid Exchange in the Murine Brain. J Neurosci. 2013;33(46):18190–18199. doi: 10.1523/JNEUROSCI.1592-13.2013 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Mestre H, Tithof J, Du T, et al. Flow of cerebrospinal fluid is driven by arterial pulsations and is reduced in hypertension. Nat Commun. 2018;9(1):4878. doi: 10.1038/s41467-018-07318-3 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Asgari M, de Zélicourt D, Kurtcuoglu V. Glymphatic solute transport does not require bulk flow. Sci Rep. 2016;6(1):38635. doi: 10.1038/srep38635 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Rey J, Sarntinoranont M. Pulsatile flow drivers in brain parenchyma and perivascular spaces: a resistance network model study. Fluids Barriers CNS. 2018;15(20):1–11. doi: 10.1186/s12987-018-0105-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Funk W, Endrich B, Messmer K, Intaglietta M. Spontaneous arteriolar vasomotion as a determinant of peripheral vascular resistance. Int J Microcirc Clin Exp. 1983;2(1):11–25. [PubMed] [Google Scholar]
  • 28.Hayoz D, Tardy Y, Rutschmann B, et al. Spontaneous diameter oscillations of the radial artery in humans. Am J Physiol Circ Physiol. 1993;264(6):2080–2084. doi: 10.1152/ajpheart.1993.264.6.H2080 [DOI] [PubMed] [Google Scholar]
  • 29.Zhang Z, Khatami R. Predominant endothelial vasomotor activity during human sleep: a near-infrared spectroscopy study. Eur J Neurosci. 2014;40(9):3396–3404. doi: 10.1111/ejn.12702 [DOI] [PubMed] [Google Scholar]
  • 30.van Veluw SJ, Hou SS, Calvo-Rodriguez M, et al. Vasomotion as a Driving Force for Paravascular Clearance in the Awake Mouse Brain. Neuron. 2020;105(3):549–561. doi: 10.1016/j.neuron.2019.10.033 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Bojarskaite L, Vallet A, Bjørnstad DM, et al. Sleep cycle-dependent vascular dynamics in male mice and the predicted effects on perivascular cerebrospinal fluid flow and solute transport. Nat Commun. 2023;14(1):953. doi: 10.1038/s41467-023-36643-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Osorio-Forero A, Cardis R, Vantomme G, et al. Noradrenergic circuit control of non-REM sleep substates. Curr Biol. 2021;31(22):5009–5023. doi: 10.1016/j.cub.2021.09.041 [DOI] [PubMed] [Google Scholar]
  • 33.Kjaerby C, Andersen M, Hauglund N, et al. Memory-enhancing properties of sleep depend on the oscillatory amplitude of norepinephrine. Nat Neurosci. 2022;25(8):1059–1070. doi: 10.1038/s41593-022-01102-9 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Antila H, Kwak I, Choi A, et al. A noradrenergic-hypothalamic neural substrate for stress-induced sleep disturbances. Proc Natl Acad Sci. 2022;119(45):1–12. doi: 10.1073/pnas.2123528119 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Osorio-Forero A, Foustoukos G, Cardis R, et al. Locus coeruleus activity fluctuations set a non - reducible timeframe for mammalian NREM - REM sleep cycles. bioRxiv. 2023;(184759):1–40. doi: 10.1101/2023.05.20.541586 [DOI] [Google Scholar]
  • 36.Avakian O V, Gillespie JS. Uptake of noradrenaline by adrenergic nerves, smooth muscle and connective tissue in isolated perfused arteries and its correlation with the vasoconstrictor response. Br J Pharmacol Chemother. 1968;32(1):168–184. doi: 10.1111/j.1476-5381.1968.tb00441.x [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Korte N, James G, You H, et al. Noradrenaline released from locus coeruleus axons contracts cerebral capillary pericytes via α 2 adrenergic receptors. J Cereb Blood Flow Metab. 2023;43(7):1142–1152. doi: 10.1177/0271678X231152549 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.Colantuoni A, Bertuglia S, Intaglietta M. Effects of anesthesia on the spontaneous activity of the microvasculature. Int J Microcirc Clin Exp. 1984;3(1):13–28. [PubMed] [Google Scholar]
  • 39.Akata T, Kodama K, Takahashi S. Volatile anaesthetic actions on norepinephrine-induced contraction of small splanchnic resistance arteries. Can J Anaesth. 1995;42(11):1040–1050. doi: 10.1007/BF03011080 [DOI] [PubMed] [Google Scholar]
  • 40.Akeju O, Brown EN. Neural oscillations demonstrate that general anesthesia and sedative states are neurophysiologically distinct from sleep. Curr Opin Neurobiol. 2017;44:178–185. doi: 10.1016/j.conb.2017.04.011 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41.Tort-Colet N, Capone C, Sanchez-Vives MV., Mattia M. Attractor competition enriches cortical dynamics during awakening from anesthesia. Cell Rep. 2021;35(12):109270. doi: 10.1016/j.celrep.2021.109270 [DOI] [PubMed] [Google Scholar]
  • 42.Picchioni D, Özbay PS, Mandelkow H, et al. Autonomic arousals contribute to brain fluid pulsations during sleep. Neuroimage. 2022;249(November 2021):118888. doi: 10.1016/j.neuroimage.2022.118888 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43.Holstein-Rønsbo S, Gan Y, Giannetto MJ, et al. Glymphatic influx and clearance are accelerated by neurovascular coupling. Nat Neurosci. 2023;26(6):1042–1053. doi: 10.1038/s41593-023-01327-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 44.Wang X, Delle C, Asiminas A, et al. Liver-secreted fluorescent blood plasma markers enable chronic imaging of the microcirculation. Cell Reports Methods. Published online September 2022:100302. doi: 10.1016/j.crmeth.2022.100302 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 45.Feng J, Zhang C, Lischinsky JE, et al. A Genetically Encoded Fluorescent Sensor for Rapid and Specific In Vivo Detection of Norepinephrine. Neuron. 2019;102(4):745–761.e8. doi: 10.1016/j.neuron.2019.02.037 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Andersen M, Tsopanidou A, Radovanovic T, et al. Using Fiber Photometry in Mice to Estimate Fluorescent Biosensor Levels During Sleep. BIO-PROTOCOL. 2023;13(15):1–17. doi: 10.21769/BioProtoc.4734 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 47.Turner KL, Gheres KW, Proctor EA, Drew PJ. Neurovascular coupling and bilateral connectivity during nrem and rem sleep. Elife. 2020;9:1. doi: 10.7554/eLife.62071 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48.Kvernmo HD, Stefanovska A, Kirkebøen KA, Kvernebo K. Oscillations in the human cutaneous blood perfusion signal modified by endothelium-dependent and endothelium-independent vasodilators. Microvasc Res. Published online 1999. doi: 10.1006/mvre.1998.2139 [DOI] [PubMed] [Google Scholar]
  • 49.Ren H, Jiang X, Xu K, et al. A Review of Cerebral Hemodynamics During Sleep Using Near-Infrared Spectroscopy. Front Neurol. 2020;11. doi: 10.3389/fneur.2020.524009 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50.Hablitz LM, Vinitsky HS, Sun Q, et al. Increased glymphatic influx is correlated with high EEG delta power and low heart rate in mice under anesthesia. Sci Adv. 2019;5(2):1–8. doi: 10.1126/sciadv.aav5447 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 51.Sigurdsson B, Hauglund NL, Lilius TO, et al. A SPECT-based method for dynamic imaging of the glymphatic system in rats. J Cereb Blood Flow Metab. Published online February 21, 2023:0271678X2311569. doi: 10.1177/0271678X231156982 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 52.Xavier ALR, Hauglund NL, von Holstein-Rathlou S, et al. Cannula Implantation into the Cisterna Magna of Rodents. J Vis Exp. 2018;(135). doi: 10.3791/57378 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 53.Hauglund NL, Kusk P, Kornum BR, Nedergaard M. Meningeal lymphangiogenesis and enhanced glymphatic activity in mice with chronically implanted EEG electrodes. J Neurosci. 2020;40(10):2371–2380. doi: 10.1523/JNEUROSCI.2223-19.2020 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 54.Plá V, Bork P, Harnpramukkul A, et al. A real-time in vivo clearance assay for quantification of glymphatic efflux. Cell Rep. 2022;40(11):111320. doi: 10.1016/j.celrep.2022.111320 [DOI] [PubMed] [Google Scholar]
  • 55.Mateo C, Knutsen PM, Tsai PS, Shih AY, Kleinfeld D. Entrainment of Arteriole Vasomotor Fluctuations by Neural Activity Is a Basis of Blood-Oxygenation-Level-Dependent “Resting-State” Connectivity. Neuron. 2017;96(4):936–948.e3. doi: 10.1016/j.neuron.2017.10.012 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 56.Zhang R, Kim CK. Correcting for the hemoglobin absorption artifact in fiber photometry data. Cell Reports Methods. 2022;2(7):100257. doi: 10.1016/j.crmeth.2022.100257 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 57.Shaner NC, Campbell RE, Steinbach PA, Giepmans BNG, Palmer AE, Tsien RY. Improved monomeric red, orange and yellow fluorescent proteins derived from Discosoma sp. red fluorescent protein. Nat Biotechnol. 2004;22(12):1567–1572. doi: 10.1038/nbt1037 [DOI] [PubMed] [Google Scholar]
  • 58.Futatsuki T, Yamashita A, Ikbar KN, et al. Involvement of orexin neurons in fasting- and central adenosine-induced hypothermia. Sci Rep. 2018;8(1):2717. doi: 10.1038/s41598-018-21252-w [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 59.Rossano AJ, Kato A, Minard KI, Romero MF, Macleod GT. Na + /H + exchange via the Drosophila vesicular glutamate transporter mediates activity-induced acid efflux from presynaptic terminals. J Physiol. 2017;595(3):805–824. doi: 10.1113/JP273105 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 60.Zhao L, Zhao Y, Tang F-L, et al. pHluorin-BACE1-mCherry Acts as a Reporter for the Intracellular Distribution of Active BACE1 In Vitro and In Vivo. Cells. 2019;8(5):474. doi: 10.3390/cells8050474 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 61.Kedarasetti RT, Turner KL, Echagarruga C, Gluckman BJ, Drew PJ, Costanzo F. Functional hyperemia drives fluid exchange in the paravascular space. Fluids Barriers CNS. 2020;17(1):52. doi: 10.1186/s12987-020-00214-3 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 62.Lilius TO, Rosenholm M, Klinger L, et al. SPECT/CT imaging reveals CNS-wide modulation of glymphatic cerebrospinal fluid flow by systemic hypertonic saline. iScience. Published online September 2022:105250. doi: 10.1016/j.isci.2022.105250 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 63.Kroesbergen E, Riesselmann LV, Gomolka RS, et al. Glymphatic clearance is enhanced during sleep. bioRxiv. Published online 2024. doi: 10.1101/2024.08.24.609514 [DOI] [Google Scholar]
  • 64.Monti JM, Spence DW, Buttoo K, Pandi-Perumal SR. Zolpidem’s use for insomnia. Asian J Psychiatr. 2017;25:79–90. doi: 10.1016/j.ajp.2016.10.006 [DOI] [PubMed] [Google Scholar]
  • 65.Machado F V, Louzada LL, Cross NE, Camargos EF, Dang-Vu TT, Nóbrega OT. More than a quarter century of the most prescribed sleeping pill: Systematic review of zolpidem use by older adults. Exp Gerontol. 2020;136:1–18. doi: 10.1016/j.exger.2020.110962 [DOI] [PubMed] [Google Scholar]
  • 66.Alexandre C, Dordal A, Aixendri R, Guzman A, Hamon M, Adrien J. Sleep-Stabilizing Effects of E-6199, Compared to Zopiclone, Zolpidem and THIP in Mice. Sleep. 2008;31(2):259–270. doi: 10.1093/sleep/31.2.259 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 67.Kopp C, Rudolph U, Tobler I. Sleep EEG changes after zolpidem in mice. Neuroreport. 2004;15(14):2299–2302. doi: 10.1097/00001756-200410050-00031 [DOI] [PubMed] [Google Scholar]
  • 68.Uygun DS, Ye Z, Zecharia AY, et al. Bottom-Up versus Top-Down Induction of Sleep by Zolpidem Acting on Histaminergic and Neocortex Neurons. J Neurosci. 2016;36(44):11171–11184. doi: 10.1523/JNEUROSCI.3714-15.2016 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 69.Fisher SP, Godinho SIH, Pothecary CA, Hankins MW, Foster RG, Peirson SN. Rapid Assessment of Sleep-Wake Behavior in Mice. J Biol Rhythms. 2012;27(1):48–58. doi: 10.1177/0748730411431550 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 70.Miao A, Luo T, Hsieh B, et al. Brain clearance is reduced during sleep and anesthesia. Nat Neurosci. Published online May 13, 2024. doi: 10.1038/s41593-024-01638-y [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 71.Mefford IN, Garrick NA. Effects of xylazine on cerebrospinal fluid catecholamines in the rhesus monkey. Brain Res. 1989;492(1–2):377–380. doi: 10.1016/0006-8993(89)90923-2 [DOI] [PubMed] [Google Scholar]
  • 72.Ambrisko TD, Hikasa Y. Neurohormonal and metabolic effects of medetomidine compared with xylazine in beagle dogs. Can J Vet Res. 2002;66(1):42–49. [PMC free article] [PubMed] [Google Scholar]
  • 73.Kanda T, Hikasa Y. Neurohormonal and metabolic effects of medetomidine compared with xylazine in healthy cats. Can J Vet Res. 2008;72(3):278–286. [PMC free article] [PubMed] [Google Scholar]
  • 74.Smith AJ, Yao X, Dix JA, Jin B-J, Verkman AS. Test of the “glymphatic” hypothesis demonstrates diffusive and aquaporin-4-independent solute transport in rodent brain parenchyma. Elife. 2017;6:1–16. doi: 10.7554/eLife.27679 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 75.Kiviniemi V, Wang X, Korhonen V, et al. Ultra-fast magnetic resonance encephalography of physiological brain activity – Glymphatic pulsation mechanisms? J Cereb Blood Flow Metab. 2016;36(6):1033–1045. doi: 10.1177/0271678X15622047 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 76.Helakari H, Korhonen V, Holst SC, et al. Human NREM Sleep Promotes Brain-Wide Vasomotor and Respiratory Pulsations. J Neurosci. 2022;42(12):2503–2515. doi: 10.1523/JNEUROSCI.0934-21.2022 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 77.Deng S, Hu Y, Chen S, et al. Chronic sleep fragmentation impairs brain interstitial clearance in young wildtype mice. J Cereb Blood Flow Metab. 2024;(130). doi: 10.1177/0271678X241230188 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 78.Vasomotion Intaglietta M. and flowmotion: physiological mechanisms and clinical evidence. Vasc Med Rev. 1990;vmr-1(2):101–112. doi: 10.1177/1358836X9000100202 [DOI] [Google Scholar]
  • 79.Aalkjær C, Boedtkjer D, Matchkov V. Vasomotion – what is currently thought? Acta Physiol. 2011;202(3):253–269. doi: 10.1111/j.1748-1716.2011.02320.x [DOI] [PubMed] [Google Scholar]
  • 80.Zhang Q-J, Hara H, Kobayashi S. Distribution Patterns of Sensory Innervation from the Trigeminal Ganglion to Cerebral Arteries in Rabbits Studied by Wheat Germ Agglutinin-conjugated Horseradish Peroxidase Anterograde Tracing. Neurosurgery. 1993;32(6):993–999. doi: 10.1227/00006123-199306000-00019 [DOI] [PubMed] [Google Scholar]
  • 81.Terrier L, Hadjikhani N, Velut S, et al. The trigeminal system: The meningovascular complex— A review. J Anat. 2021;239(1):1–11. doi: 10.1111/joa.13413 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 82.Kozberg MG, Munting LP, Maresco LH, et al. Loss of spontaneous vasomotion precedes impaired cerebrovascular reactivity and microbleeds in a mouse model of cerebral amyloid angiopathy. BioR. Published online 2024. doi: 10.1101/2024.04.26.591414 [DOI] [Google Scholar]
  • 83.Zimmerman B, Rypma B, Gratton G, Fabiani M. Age-related changes in cerebrovascular health and their effects on neural function and cognition: A comprehensive review. Psychophysiology. 2021;58(7):e13796. doi: 10.1111/psyp.13796 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 84.Lennon MJ, Makkar SR, Crawford JD, Sachdev PS. Midlife Hypertension and Alzheimer’s Disease: A Systematic Review and Meta-Analysis. J Alzheimer’s Dis. 2019;71(1):307–316. doi: 10.3233/JAD-190474 [DOI] [PubMed] [Google Scholar]
  • 85.Abdulrahman H, van Dalen JW, den Brok M, Latimer CS, Larson EB, Richard E. Hypertension and Alzheimer’s disease pathology at autopsy: A systematic review. Alzheimer’s Dement. 2022;18(11):2308–2326. doi: 10.1002/alz.12707 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 86.Bork PAR, Ladrón-de-Guevara A, Christensen AH, Jensen KH, Nedergaard M, Bohr T. Astrocyte endfeet may theoretically act as valves to convert pressure oscillations to glymphatic flow. J R Soc Interface. 2023;20(204):1–5. doi: 10.1098/rsif.2023.0050 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 87.Gan Y, Holstein-Rønsbo S, Nedergaard M, Boster KAS, Thomas JH, Kelley DH. Perivascular pumping of cerebrospinal fluid in the brain with a valve mechanism. J R Soc Interface. 2023;20(206):1–17. doi: 10.1098/rsif.2023.0288 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 88.von Holstein-Rathlou S, Petersen NC, Nedergaard M. Voluntary running enhances glymphatic influx in awake behaving, young mice. Neurosci Lett. 2018;662(September 2017):253–258. doi: 10.1016/j.neulet.2017.10.035 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 89.Jiang-Xie L-F, Drieu A, Bhasiin K, Quintero D, Smirnov I, Kipnis J. Neuronal dynamics direct cerebrospinal fluid perfusion and brain clearance. Nature. 2024;627(8002):157–164. doi: 10.1038/s41586-024-07108-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 90.Murdock MH, Yang CY, Sun N, et al. Multisensory gamma stimulation promotes glymphatic clearance of amyloid. Nature. 2024;627(8002):149–156. doi: 10.1038/s41586-024-07132-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 91.Kralic JE, O’Buckley TK, Khisti RT, Hodge CW, Homanics GE, Morrow AL. GABAA receptor alpha-1 subunit deletion alters receptor subtype assembly, pharmacological and behavioral responses to benzodiazepines and zolpidem. Neuropharmacology. 2002;43(4):685–694. doi: 10.1016/S0028-3908(02)00174-0 [DOI] [PubMed] [Google Scholar]
  • 92.Mittal N, Mittal R, Gupta MC. Zolpidem for Insomnia: A Double-Edged Sword. A Systematic Literature Review on Zolpidem-Induced Complex Sleep Behaviors. Indian J Psychol Med. Published online 2021. doi: 10.1177/0253717621992372 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 93.Shih H-I, Lin C-C, Tu Y-F, et al. An Increased Risk of Reversible Dementia May Occur After Zolpidem Derivative Use in the Elderly Population. Medicine (Baltimore). 2015;94(17):e809. doi: 10.1097/MD.0000000000000809 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 94.Merel SE, Paauw DS. Common Drug Side Effects and Drug-Drug Interactions in Elderly Adults in Primary Care. J Am Geriatr Soc. 2017;65(7):1578–1585. doi: 10.1111/jgs.14870 [DOI] [PubMed] [Google Scholar]
  • 95.Leong CWY, Leow JWS, Grunstein RR, et al. A systematic scoping review of the effects of central nervous system active drugs on sleep spindles and sleep-dependent memory consolidation. Sleep Med Rev. 2022;62:101605. doi: 10.1016/j.smrv.2022.101605 [DOI] [PubMed] [Google Scholar]
  • 96.Zhang J, Yetton B, Whitehurst LN, Naji M, Mednick SC. The effect of zolpidem on memory consolidation over a night of sleep. Sleep. 2020;43(11). doi: 10.1093/sleep/zsaa084 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 97.Lohela TJ, Lilius TO, Nedergaard M. The glymphatic system: implications for drugs for central nervous system diseases. Nat Rev Drug Discov. 2022;21(10):763–779. doi: 10.1038/s41573-022-00500-9 [DOI] [PubMed] [Google Scholar]
  • 98.Tsai C-J, Nagata T, Liu C-Y, et al. Cerebral capillary blood flow upsurge during REM sleep is mediated by A2a receptors. Cell Rep. 2021;36(7):109558. doi: 10.1016/j.celrep.2021.109558 [DOI] [PubMed] [Google Scholar]
  • 99.Lee H, Xie L, Yu M, et al. The Effect of Body Posture on Brain Glymphatic Transport. J Neurosci. 2015;35(31):11034–11044. doi: 10.1523/JNEUROSCI.1625-15.2015 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 100.Plog BA, Mestre H, Olveda GE, et al. Transcranial optical imaging reveals a pathway for optimizing the delivery of immunotherapeutics to the brain. JCI Insight. 2018;3(23):1–15. doi: 10.1172/jci.insight.126138 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 101.Jing M, Li Y, Zeng J, et al. An optimized acetylcholine sensor for monitoring in vivo cholinergic activity. Nat Methods. 2020;17(11):1139–1146. doi: 10.1038/s41592-020-0953-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 102.Wan J, Peng W, Li X, et al. A genetically encoded sensor for measuring serotonin dynamics. Nat Neurosci. 2021;24(5):746–752. doi: 10.1038/s41593-021-00823-7 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 103.Zhu R, Zhang G, Jing M, et al. Genetically encoded formaldehyde sensors inspired by a protein intra-helical crosslinking reaction. Nat Commun. 2021;12(1):581. doi: 10.1038/s41467-020-20754-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 104.Wu Z, He K, Chen Y, et al. A sensitive GRAB sensor for detecting extracellular ATP in vitro and in vivo. Neuron. 2022;110(5):770–782. doi: 10.1016/j.neuron.2021.11.027 [DOI] [PubMed] [Google Scholar]
  • 105.Eide PK, Vatnehol SAS, Emblem KE, Ringstad G. Magnetic resonance imaging provides evidence of glymphatic drainage from human brain to cervical lymph nodes. Sci Rep. 2018;8(1):7194. doi: 10.1038/s41598-018-25666-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 106.Demiral ŞB, Tomasi D, Sarlls J, et al. Apparent diffusion coefficient changes in human brain during sleep – Does it inform on the existence of a glymphatic system? Neuroimage. 2019;185:263–273. doi: 10.1016/j.neuroimage.2018.10.043 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 107.Yang G, Deng N, Liu Y, Gu Y, Yao X. Evaluation of Glymphatic System Using Diffusion MR Technique in T2DM Cases. Front Hum Neurosci. 2020;14:1–7. doi: 10.3389/fnhum.2020.00300 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 108.Lecci S, Fernandez LMJ, Weber FD, et al. Coordinated infraslow neural and cardiac oscillations mark fragility and offline periods in mammalian sleep. Sci Adv. 2017;3(2):1–14. doi: 10.1126/sciadv.1602026 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 109.Lázár ZI, Dijk D-J, Lázár AS. Infraslow oscillations in human sleep spindle activity. J Neurosci Methods. 2019;316:22–34. doi: 10.1016/j.jneumeth.2018.12.002 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 110.Viglione A, Mazziotti R, Pizzorusso T. From pupil to the brain: New insights for studying cortical plasticity through pupillometry. Front Neural Circuits. 2023;17. doi: 10.3389/fncir.2023.1151847 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 111.Carro-Domínguez M, Huwiler S, Oberlin S, et al. Pupil size reveals arousal level dynamics in human sleep. bioRxiv. Published online 2023. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 112.Vittani M, Knak PAG, Hiraoka Y, et al. Visualization of murine cerebral circulation by fluorescent protein knock-in to the albumin locus. In: Society for Neuroscience Meeting.; 2023:abstract number 357.07. [Google Scholar]
  • 113.Siegle JH, López AC, Patel YA, Abramov K, Ohayon S, Voigts J. Open Ephys: an open-source, plugin-based platform for multichannel electrophysiology. J Neural Eng. 2017;14(4):1–13. doi: 10.1088/1741-2552/aa5eea [DOI] [PubMed] [Google Scholar]
  • 114.Yushkevich PA, Piven J, Hazlett HC, et al. User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability. Neuroimage. 2006;31(3):1116–1128. doi: 10.1016/j.neuroimage.2006.01.015 [DOI] [PubMed] [Google Scholar]
  • 115.Fischer MJM, Uchida S, Messlinger K. Measurement of meningeal blood vessel diameter in vivo with a plug-in for ImageJ. Microvasc Res. 2010;80(2):258–266. doi: 10.1016/j.mvr.2010.04.004 [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

1

RESOURCES