Abstract
Background
Intertrochanteric (IT) fractures in the elderly are a major orthopaedic challenge due to osteoporotic bone quality, implant anchorage difficulties, and associated comorbidities. These factors contribute to nearly one-third mortality within a year of injury, representing a significant global health and economic burden.
Methods
Historically, stable IT fractures were treated with surface implants such as dynamic hip screws (DHS), whilst intramedullary (IM) implants like proximal femoral nails (PFN) were reserved for unstable patterns. Evidence from 1999 to 2010, including Cochrane reviews, supported this practice. However, recent studies and updated Cochrane data advocate intramedullary fixation for both stable and unstable fractures. The authors draw from their extensive experience on intertrochanteric fracture management, ten important principles on fixing intertrochanteric fractures using PFN.
Results
Current evidence supports the use of intramedullary implants as the preferred method for intertrochanteric fracture fixation. The authors concur with this trend and share practical tips to improve outcomes using PFN. Emphasis is placed on achieving optimal fracture reduction, which directly correlates with surgical success. Once adequate reduction is attained, a variety of intramedullary devices can effectively maintain alignment. These principles are presented as ten commandments in this article.
Conclusion
Intramedullary fixation, particularly with proximal femoral or trochanteric fixation nail (TFN) utilising a dual screw system, is recommended for both stable and unstable intertrochanteric fractures in the elderly. Despite the availability of single screw systems favoured for their ease of use, the authors maintain preference for the two-screw design due to enhanced stability. Surgical expertise in achieving and maintaining reduction remains paramount to successful outcomes.
Keywords: Inter trochanteric fractures, Proximal femoral nailing, PFN, Ten commandments, Tips and tricks, Intramedullary nailing, Hip fractures
Fixations of IT fractures in the elderly are challenging surgeries. The bones are osteoporotic with implants having less hold and the comorbidities associated in the elderly lead to almost one-third mortality by the end of one year, which contributes to a significant global economic burden. Hip fractures account for over 250,000 cases annually in the US alone. The worldwide problem at present stands at over 2 million fractures and it is expected to triple by the next 50 years due to the more longevity with better healthcare facilities. The treatment option for osteosynthesis includes open/closed reduction and fixation either with surface implants such as dynamic hip screw (DHS) or intramedullary (IM) implants such as proximal femoral nail (PFN).
Between approximately 1999 and 2010, most of the studies and the Cochrane reviews were advising DHS or the sliding Hip screw for Stable IT fractures whereas for unstable fractures, the IM implants were advocated. Now, most of the studies including the recent Cochrane data advocate the use of IM hip implants both for stable and unstable fractures. The authors also prefer and advocate the same. Here are few tips and tricks to get a better outcome with IM implants (PFN).
Reduction is the most important aspect of any fracture. The outcome of any surgery mainly depends on the surgeon’s skill in achieving reduction in the given situation. Once a fracture is reduced well, it can be stabilised in that reduced position by using any of the so many varieties of intramedullary implants which are available in the market. The authors, still as first choice, prefer the PFN and TFN with two screw system, though many surgeons prefer to use a single neck screw system due to its ease of use and surgeon-friendly instrumentation set.
Here are the Ten Commandments advocated by the authors to get good results with PFN.
1. Position: for doing any hip surgery, the surgeon must be comfortable, and he should have good access to the hip. The authors prefer eccentric placement of perineal post (Fig. 1), so that after reduction and fixation with K wires, the limb can be adducted to get easy access of the hip to make the entry point more on the medial side of greater trochanter from the neck itself. This eccentric placement of the perineal post helps in adducting the limb without the worry of fracture opening superiorly causing varus at the fracture site. To prevent the patient sliding back from eccentric position to centric position, authors use a small sand bag tied to the table as shown in Fig. 2a and b. The authors also tilt the table by about 15 to 20 degrees on the normal side (Fig. 3a and b). This helps in getting proper lateral view of the hip as the femoral head and neck are anteverted. This tilting prevents patient falling on the side of the surgeon too. A side support or the chest support also prevents patient sagging on operative side especially when traction is applied for the limb. Few surgeons prefer lateral decubitus position but the authors prefer to operate these IT fractures on a traction table and only sub trochanteric fractures he prefers to use lateral position.
Fig. 1.

Eccentrically placed patient on Orthopaedic Traction Table. Perineal post will not prevent adduction of the limb
Fig. 2.
a View from above and b View from side, showing perineal post and the sand bag to prevent patient sliding back to centric position from the eccentric placement as shown in Fig. 1
Fig. 3.
a and b. Showing Table horizontal with femoral neck anteverted in C arm whereas by tilting the table on normal side, the head and neck comes more in line with the shaft. This helps in easy visualisation of true lateral view of hip and also patient falls due to gravity more on normal side. The sand bag prevents sliding of the patient
2. Reduction: the foremost important factor for successful outcome with intramedullary nailing is reduction. Reduction has to be good both of medial as well as anterior cortex. The reduction must be in valgus or positive cortical support, so that the neck beak can never slip into the shaft medullary canal into varus leading to failure. The reduction must be in additional 5 to 10* valgus especially if there is a void medially created by the avulsed lesser trochanter. The reduction can be assisted either by manipulating the fragment by closed techniques or by percutaneous mini-open techniques such as using a bone lever, bone spatula, bone hook, and collinear clamps The authors prefer to use percutaneously passed Steinmann pin (Fig. 4a) for intra focal manipulation and prefers to fix with two Kirschner’s wires of 2.5 mm thickness placed more anteriorly in the head and neck (Fig. 4b), so that they will not hinder the further steps of surgery like either passing of the nail or the neck screws. Once the fracture is fixed with 2 K wires after reduction, the limb can be adducted (Fig. 5a and b) as needed without the worry of fracture going into varus or the fracture opening superiorly especially whilst reaming with centring awl to lead to varus and the nail can be passed easily.
Fig. 4.
a(1 to 4) and b(1 to 4). Showing reduction technique by percutaneous intra-focal manipulation with Steinmann Pin and fixing the reduced fracture with two K wires very anteriorly placed in the head and neck
Fig. 5.
(a—Normal & b—adducted) Nail entry made easy by adducting the limb after fixation with 2 Kirshner Wires
Good medial reduction (positive cortical reduction) or the valgoid reduction of at least 5 degrees more in valgus compared to the normal side is also very important. In valgoid reduction, we make sure that neck beak is outside the distal fragment (positive cortical reduction) and should not enter into the shaft (negative cortical support) (Figs. 6a, b and c & Fig. 7). One should aim at neutral with valgus or Positive cortical reduction. This can be done by intra-focal Steinmann pin pushing the beak out medially and reducing the foot traction minimally so that beak will overlap medially on the beak of the shaft and it can never slip back inside the distal canal due to this few millimetres overlap (Fig. 4).
Fig. 6.
a, b and c Negative, Neutral and Positive Cortical Support remove patient identifier from 6B and 6C
Fig. 7.
a and b Neutral Reduction with Lesser Trochanteric Avulsion slipping into Negative cortical Support
If there is a large medial fragment of lesser trochanter extending into the subtrochanteric area, the authors prefer to fix them with encirclage wiring. In just avulsion of lesser trochanter, even if it is not reduced into its bed by opening a good valgus compensates for the medial void very well (Fig. 8).
Fig. 8.
Reduction in Additional valgus when lesser trochanteric void present leading to early union at 5 weeks
If there is a large medial fragment, fixing them with a cerclage wiring (Fig. 9a and b) as the first step as this gives stability to the fracture and helps in early union. Minor fragments can be left alone if fracture is treated by closed methods, but if large fragments are left alone, it takes more time for the fragment to get incorporated and heal. Hence the authors advocate anatomical reduction and wiring whenever possible.
Fig. 9.
a and b large medial fragment along calcar and weight transmission axis being fixed first with an encirclage wire
3. Entry Point: the authors strongly recommend entry in line with medullary canal for all nailings of the femur by any implant. They feel that shifting the entry more laterally to the tip of trochanter, which is more surgeon friendly, is the basis of mal reduction and in turn failure due to varus. They also feel that there are some anatomical variations in the canal size, position of the tip of the trochanter, morphology of the proximal femur due to social customs like Asian’s sitting down cross legged on floor, squatting etc. whereas the westerners using chair normally are probably causing these morphological changes. The tip of the trochanter is placed more lateral in Asians compared to Caucasians in whom the medullary canal is almost in line with the tip of the trochanter and hence the entry needs to be in line with the medullary canal, especially whilst operating in a narrow medullary canal patient (Authors feel that this needs to be supported by a larger study as this is only a personal observation and authors feel that this is probably due to the habit of people sitting down cross legged may be the cause along with short stature and narrow medullary canals in Asians). Hence, the entry point must be in line with the medullary canal, which is almost always either the piriformis fossa (Fig. 10a), (which is a misnomer as piriformis fossa is much more posterior in the lateral view and not in the central part where the entry is taken for cephalomedullary nails,) this area is medial to the tip of trochanter at its base in AP and centre of neck in lateral view (Fig. 10b). This entry site is also called as Foot Hill Entry point. One should take care to enlarge the entry site, which is on the thick cortical bone of the neck by sharp awl (Fig. 11 a and b) or by a cheese cutter (Fig. 12a, b and c) and avoid the entry site getting lateralised inadvertently due to softer bone lateral to the entry point. As the bone is weaker on the lateral aspect, whilst passing the centring awl or the entry reamer, more bone gets removed on outer aspect and the entry site will get inadvertently lateralised leading to varus (Fig. 13 a, b and c). This in turn leads to the head and neck tilting in varus as well as screw position not proper in the head and neck, (screw in the inferior part of the neck will be central or in superior portion of the head) leading to early cut out of the improperly placed neck screw in a varus head.
Fig. 10.
a Piriformis Entry b Showing Entry medial to the base of Trochanter
Fig. 11.
a and b Sharp curved Awl to remove strong neck bone
Fig. 12.
a, b and c showing Cheese cutter being used to remove strong neck bone to prevent excessive lateralisation of entry point
Fig. 13.

(a–c). Entry getting lateralised due to softer bone on outer aspect of the entry site
4. Neck Screw Placement: neck screws should be placed parallel to the calcar, in the inferior third of the neck in AP view so that the tip of the screw should also be in the inferior part of the head and not at the centre or superior portion of the head. In the lateral view, the wire and screw should be placed in the centre or slightly posterior part of the neck and the head so that it has the purchase in the strongest part of the bone. (Fig. 14a, b, c). This will allow easy sliding of the neck screw within the nail and causes less jamming. For passing these screws properly over guide wire, one should use the trocar first to make the starting hole in the lateral cortex of the bone. The long Guide wires of 1.8–2 mm are not made for drilling the thick lateral cortex like the drill bits and they may slip over the bone especially due to longer lever arm from the other end where drill machine is attached (Fig. 15a, b). The authors prefer to use the two-screws system and both the neck screw should preferably end at a same horizontal plane, the derotation screw being little smaller and shorter. This helps in easy sliding of both the screws, whilst if superior derotation screw is longer, the load is taken predominantly by this screw leading to breakage or the sliding mechanism getting jammed. This is due to the stress at the screw nail junction leading to Z effect and reverse Z effect (Fig. 16 a, b).
Fig. 14a.
Showing Screw Position inferior third in Neck as well as head. b and c Showing Neck Screw inferior in AP and Posterior in lateral view
Fig. 15.
a and b Showing Trocar used to open the lateral cortex before passing the thin long neck guide wires of PFN/TFN
Fig. 16.
a X ray showing Z effect and b showing reverse Z effect. c Right side hip showing breakage of longer de-rotational screw, whereas left hip shows ideal tip position of both screws at same horizontal level
5. TAD (tip apex distance) of Neck Screw: the best purchase any neck screw will have is in the subchondral bone and hence, the main cervical neck screw should be placed as subchondral as possible. So if TAD is measured from fovea centralis, even though the screw is subchondral, the TAD measured will be more than optimum in spite of screw being in a very good and strong bone position and in spite of screw tip being placed in a subchondral part of the head. Hence one should measure the calcar TAD (Cal TAD), which is measured by extrapolating the screw line to the subchondral bone and where that line meets the articular surface, the TAD is measured instead of measuring from more centrally and superiorly placed fovea Centralis (Fig. 17). So, we should aim to keep the Cal TAD definitely below 25 mm considering both AP and Lateral picture measurements together.
Fig. 17.

TAD and Cal TAD in AP
6. Well Compressed Fracture: the authors feel that the fracture needs to be well compressed on the table itself and one should not rely on the uncontrolled inbuilt collapse which can happen by gradual sliding of the neck screws within the nail. The authors feel that failure in PFN is mainly due to not adequately compressing fracture. This happens due to not releasing the traction before final neck screw tightening or by using a little shorter screw or due to using little longer screw and leaving it out slightly. By using little shorter screw, the surgeon tries to reach the subchondral bone and by these extra tightening the shorter screw, the threads of the screw lose their purchase and becomes loose in the osteoporotic head (Fig. 18a, b, c). The authors further say that the failures are mainly due to head of the neck screw not having the support of the lateral wall which leads to toggling of the screw and giving loose purchase in the bone. They further state that, like intra capsular fractures, where we compress fracture first and then prevent further compression either by replacing with few fully threaded screws or a Pauwel’s screw, even in inter trochanteric fractures, the fracture should be compressed on the table and prevent any further collapse happening. In cases of comminuted lateral wall, the authors advocate to reconstruct the lateral wall by fixing with a screw or binding them together with wiring (Fig. 21a1, a2, a3) or to use a trochanteric buttress plate (Fig. 21b1, b2, b3) to compensate for the deficient lateral wall and try to compress the fracture against the reconstructed lateral wall. If the neck screw has a head, then the neck screw can be compressed against the nail piercing the osteoporotic lateral wall or the comminuted lateral wall and the heads can rest against the nail itself which is now acting as lateral wall. (Figs. 19d,e,f, and Fig. 20).
Fig. 18.
a, b and c. Showing 75 year lady with 2 weeks old osteoporotic IT fracture fixed with PFN. Note the screw head which is against the lateral wall on day 1 staying there only even after 14 months, indicating adequate compression on table and the fracture did not further collapse. Please also note the Positive cortical support and subchondral placement of neck screw
Fig. 21.
a Three most important points of fixation of an IM Implant. Namely Subchondral (b) Screw Placement, Neck screw slightly out of lateral cortex and finally the nail slightly out at the entry point. b Showing Nail properly projecting out at the entry site. c showing uncontrolled medialisation like a SHS/DHS when the nail tip is buried inside the cancellous bone at the entry site. d Showing Nail toggling and leading to failure when tip is burrier inside the cancellous bone
Fig. 19.
a Back end of the headless neck screw going inside the lateral cortex. b and c showing Neck screw slightly kept out of the lateral cortex to allow screw backing out due to fracture collapse, if needed. (d) showing IT Fracture with Comminuted lateral wall, here the nail itself acts as the lateral wall and see the heads of the screws resting against the nail instead of the missing lateral wall (e, f)
Fig. 20.
Composite picture showing IT fracture with comminuted lateral wall and greater Trochanter avulsion, treated with TFN having head for the neck screws, the nail compensating for the missing lateral wall and the screw heads resting against the nail. Wiring of greater trochanteric avulsion has been done. Incidentally, this patient had SHS/DHS on the opposite side and the neck length has decreased due to uncontrolled medialisation of the shaft
The authors feel that the sliding mechanism of the neck screws in the nail is not at all required in all cases and only in few cases where there will be extra resorption at the fracture site, only the implants sliding neck screw mechanism should be relied. Yes, in the eighties and nineties when the intramedullary implants were not available, the DHS with its sliding mechanism was the gold standard and we all relied upon the fracture collapse for union. That doesn’t mean that uncontrolled collapse should be allowed to happen even now when better fixation systems like the IM nails are available.
7. Tips for Headless Neck Screws: the authors personally prefer IM Nail for the hip like PFN and TFN which have heads for the neck screw and the fracture can be adequately compressed as required by tightening these neck screws having head against the lateral wall or even against the nail in osteoporotic bones or in cases having deficit lateral wall. There are many newer single neck screw systems like PFN A2, ZNN, TFN A, etc. which are more surgeon friendly due to their of usage and passing just a single neck screw. All these newer systems do not have head for the neck screw. Hence if these screws are passed inside beyond the lateral cortex hole created (Fig. 19a), many a times during the course of fracture healing with a bit of collapse, these helical blades cannot slide out of the lateral cortex hole due to mismatch leading to these helical blades penetrating into the joint. So, the authors advise, if at all these types of implants with neck screw having no heads are used, then it is better to keep the back end of these neck screws or the blades 3–5 mm out (Fig. 19b, c) so that they can slide out easily rather than penetrating into the joint during the course of fracture collapse and healing. Fig. 19e, f and Fig. 20 shows the examples of using neck screws with heads and their advantages.
8. Nail projection at entry site: there are three important things which give support to the nail (Fig. 21a) to make it stable after fracture is fixed. The first one is subchondral placement of the screw, the second is the back side of neck screw having the support of the lateral wall and the third point is nail being slightly projecting out at the entry site. The nail has to be little projecting above the entry hole (Fig. 21b) so that the purchase of the nail at this site prevents medialisation of the shaft. If it is buried inside the cancellous bone, it can toggle, migrate medially (Fig. 21c, d) and can lead to instability, non-union and implant failure. It can be addressed by additional end cap over the tip of the nail to build up the nail to project out at the entry site.
9. Static/dynamic locking: though there are many studies in the literature showing good outcomes with static locking as well as dynamic locking, the authors feel that in few cases where fracture resorption is a bit more than normally expected, either they require dynamisation in time at 6 to 8 weeks or they can be dynamically locked from day one itself. We have observed that a few patients, especially, those belonging to the low socioeconomic status, may try to avoid the ‘second surgery’ of dynamisation leading to complications and failures in due course. Hence the authors do only dynamic locking from day one itself and with the experience of treating large number of cases over three decades, the authors strongly advocate only dynamic locking. The dynamic locking also allows axial micromotion like an Illizarov fixator whilst walking with walker in the initial few weeks and helps in throwing secondary callus and early consolidation (Figs. 22a- > d, Fig.23 and Fig. 24).
Fig. 22.
a–d Interlocking bolt migrating up due to dynamic locking during the course of fracture healing
Fig. 23.
(a1–a3). Interlocking bolt position showing dynamisation during the course of fracture healing. (b1- > b3) Showing Dynamisation working with nail subsidence in the canal due to fracture collapse and the dynamic locking bolt moving up in the dynamic hole of the nail
Fig. 24.
An example of static locking showing not allowing dynamisation and collapse leading to non-union and implant giving away. Also note that as the superior screw is also longer, it has taken the brunt of weight bearing leading to its breakage also
10. Choice of implant: good implant from a good manufacturer with laser marking to trace back if complication arises and not a poor copy from a fly by night lesser-known company, costing a bit less should be used to avoid complications related to metal quality and strength of the implant. Finally, after a very robust and stable fixation, the patient should be mobilised as pain tolerated weight bearing with a walker is stated to enhance early fracture union and to minimise complications of prolonged immobilisation. Once the patient is made to walk, his/her morale will be boosted and will cooperate for proper physiotherapy also.
Data availability
Data not required as these findings are based on extensive experience of operating on varieties of cases and the authors share their tips to avoid mistakes.
Declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical approval
This article does not contain any studies with human or animal subjects performed by any of the authors
Informed consent
For this type of study informed consent is not required.
Footnotes
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Further readings
- 1.Shivashankar, B., & Keshkar, S. (2021). Intertrochanteric fractures: Ten commandments for how to get good results with proximal femoral nailing. Indian Journal of Orthopaedics,55, 521–524. 10.1007/s43465-021-00373-x [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Bhandari, M., Devereaux, P. J., Tornetta, P., 3rd., Swiontkowski, M. F., Berry, D. J., Haidukewych, G., et al. (2005). Operative management of displaced femoral neck fractures in elderly patients. An international survey. The Journal of Bone and Joint Surgery: American Volume,87(9), 2122–2130. [DOI] [PubMed] [Google Scholar]
- 3.Lenich, A., Vester, H., Nerlich, M., Mayr, E., Stöckle, U., & Füchtmeier, B. (2010). Clinical comparison of the second and third generation of intramedullary devices for trochanteric fractures of the hip—blade vs screw. Injury,41, 1292–1296. [DOI] [PubMed] [Google Scholar]
- 4.Sadowski, C., Lübbeke, A., Saudan, M., Riand, N., et al. (2002). Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screwplate: A prospective, randomized study. The Journal of Bone and Joint Surgery: American,84A, 372–381. [PubMed] [Google Scholar]
- 5.Anglen, J. O., Weinstein, J. N., American Board of Orthopaedic Surgery Research Committee. (2008). Nail or plate fixation of intertrochanteric hip fractures: Changing pattern of practice. A review of the American Board of Orthopaedic Surgery database. The Journal of Bone and Joint Surgery,90, 700–707. [DOI] [PubMed] [Google Scholar]
- 6.Sanders, D., Bryant, D., Tieszer, C., Lawendy, A.-R., MacLeod, M., Papp, S., et al. (2017). A multicenter randomized control trial comparing a novel intramedullary device (InterTAN) versus conventional treatment (sliding hip screw) of geriatric hip fractures. Journal of Orthopaedic Trauma,31, 1–8. [DOI] [PubMed] [Google Scholar]
- 7.De Castro, J., Unsay, I. C., Huat, T., & Kee, E. K. B. (2020). Early experience with the trochanteric fixation nail-advanced (TFN-A): A descriptive review of thirty-four cases from a single center. The Indian Journal of Orthopaedics.,54(Suppl 2), 246–253. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Chang, S.-M., Zhang, Y.-Q., Ma, Z., Li, Q., Dargel, J., & Eysel, P. (2015). Fracture reduction with positive medial cortical support: A key element instability reconstruction for the unstable pertrochanteric hip fractures. Archives of Orthopaedic and Trauma Surgery.,135(6), 811–818. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Baumgaertner, M. R., Curtin, S. L., Lindskog, D. M., & Keggi, J. M. (1995). The value of the tip apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. Journal of Bone and Joint Surgery,77, 1058–1064. [DOI] [PubMed] [Google Scholar]
- 10.Aicale, R., & Maffulli, N. (2018). Greater rate of cephalic screw mobilisation following proximal femoral nailing in hip fractures with a tip–apex distance (TAD) and a calcar referenced TAD greater than 25 mm. Journal of Orthopaedic Surgery and Research.,13, 106. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Henschel, et al. (2016). Load distribution between cephalic screws in a dual lag screw trochanteric nail. Journal of Orthopaedic Surgery and Research,11, 41. 10.1186/s13018-016-0377-y [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Abulsoud, M. I., Elmarghany, M., Ibrahim, M. A. A., et al. (2024). The “foothill” entry for cephalomedullary nailing in unstable proximal femoral fractures: A technical note with a review of the literature. European Journal of Orthopaedic Surgery & Traumatology,34, 3365–3371. 10.1007/s00590-024-04014-5 [DOI] [PubMed] [Google Scholar]
- 13.Ganjale, S. B., Gadegone, W. M., & Kothadia, P. (2018). Trochanteric buttress plate combined with proximal femoral nail for unstable intertrochanteric fractures. Open Journal of Orthopedics. 10.4236/ojo.2018.86027 [Google Scholar]
- 14.Kulkarni, S. G., Babhulkar, S. S., Kulkarni, S. M., Kulkarni, G. S., Kulkarni, M. S., & Patil, R. (2017). Augmentation of intramedullary nailing in unstable intertrochanteric fractures using cerclage wire and lag screws: A comparative study. Injury,48(Suppl 2), S18–S22. 10.1016/S0020-1383(17)30489-8. PMID: 28802415. [DOI] [PubMed] [Google Scholar]
- 15.Gadegone, W. M., Shivashankar, B., Lokhande, V., & Salphale, Y. (2017). Augmentation of proximal femoral nail in unstable trochanteric fractures. SICOT J. 10.1051/sicotj/2016052 [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Data not required as these findings are based on extensive experience of operating on varieties of cases and the authors share their tips to avoid mistakes.





















