Skip to main content
. Author manuscript; available in PMC: 2025 Aug 22.
Published in final edited form as: Am J Prev Med. 2025 May 28;69(2):107736. doi: 10.1016/j.amepre.2025.107736

Appendix Table 2.

Risk of Bias Assessments From Systematic Reviews and Meta-Analyses Included in Literature Search

Publication Risk of Bias Assessment by 2022 Cochrane Review1 Risk of Bias Assessment by 2021 Review by Field et al.2 Risk of bias and overall quality Rating by USPSTF3
United States National Lung Screening Trial (NLST) Aberle 20114, NLST 20195 Random sequence generation: Low
Allocation concealment: Low
Blinding of participants of personnel: High
Blinding of outcome assessment: Low
Incomplete outcome data: Low
Selective reporting: Low
Other bias: Low
Randomization process: Low
Deviations from intended intervention: Low
Missing outcome data: Low
Measurement of the outcome: Low
Selective reporting: Low
Overall: Low
Fair
German Lung Cancer Screening Intervention (LUSI) Becker 20206 Random sequence generation: Low
Allocation concealment: Low
Blinding of participants of personnel: High
Blinding of outcome assessment: Unclear
Incomplete outcome data: Low
Selective reporting: Low
Other bias: Low
Randomization process: Low
Deviations from intended intervention: Low
Missing outcome data: Low
Measurement of the outcome: some concerns
Selective reporting: Low
Overall: some concerns
Fair
Multicentric Italian Lung Detection Trial (MILD) Pastorino 20197 Random sequence generation: Low
Allocation concealment: Low
Blinding of participants of personnel: High
Blinding of outcome assessment: Low
Incomplete outcome data: Low
Selective reporting: Low
Other bias: Low
Randomization process: High
Deviations from intended intervention: some concerns
Missing outcome data: Low
Measurement of the outcome: Low
Selective reporting: Low
Overall: High
Poor
Dutch-Belgian Nederlands-Leuvens Longkanker Screenings Onderzoek trial (NELSON) De Koning 20208 Random sequence generation: Low
Allocation concealment: Low
Blinding of participants of personnel: High
Blinding of outcome assessment: High
Incomplete outcome data: Low
Selective reporting: Low
Other bias: High
Randomization process: Low
Deviations from intended intervention: Low
Missing outcome data: Low
Measurement of the outcome: Low
Selective reporting: Low
Overall: Low
Not available
Italian Lung Cancer Screening trial (ITALUNG) Paci 20179 Random sequence generation: Low
Allocation concealment: Low
Blinding of participants of personnel: High
Blinding of outcome assessment: Low
Incomplete outcome data: Low
Selective reporting: Low
Other bias: Low
Randomization process: Low
Deviations from intended intervention: Low
Missing outcome data: Low
Measurement of the outcome: Low
Selective reporting: Low
Overall: Low
Fair
UK Lung Cancer Screening Trial (UKLS) Field 20212 Random sequence generation: Low
Allocation concealment: Low
Blinding of participants of personnel: High
Blinding of outcome assessment: Low
Incomplete outcome data: Low
Selective reporting: Low
Other bias: High
Randomization process: Low
Deviations from intended intervention: Low
Missing outcome data: Low
Measurement of the outcome: Low
Selective reporting: Low
Overall: Low
Not available
Italian Detection And screening of early lung cancer by Novel imaging TEchnology trial (DANTE) Infante 201510 Random sequence generation: Low
Allocation concealment: Low
Blinding of participants of personnel: High
Blinding of outcome assessment: High
Incomplete outcome data: Low
Selective reporting: Low
Other bias: High
Randomization process: some concerns
Deviations from intended intervention: some concerns
Missing outcome data: high
Measurement of the outcome: Low
Selective reporting: Low
Overall: High
Fair
Danish Lung Cancer Screening Trial (DLCST) Wille 201611 Random sequence generation: Low
Allocation concealment: Low
Blinding of participants of personnel: High
Blinding of outcome assessment: Low
Incomplete outcome data: Low
Selective reporting: Low
Other bias: Low
Randomization process: Low
Deviations from intended intervention: some concerns
Missing outcome data: Low
Measurement of the outcome: Low
Selective reporting: Low
Overall: some concerns
Good