Table 5.
Results of thermoeconomic assessment for proposed plant.
| Component |
|
, $/yr |
, $/yr |
, $/yr |
, $/yr |
|---|---|---|---|---|---|
| Boiler | 45.2 | 0.50 | 621.8 | 613 | 764 |
| Turbine | 90.0 | 10.60 | 101,503 | 90307.5 | 11,196 |
| Pump | 69.85 | 0.98 | 3656.5 | 2552 | 1104 |
| Condenser (ORC) | 1.0 | 157.51 | 70,863 | 794 | 70,854 |
| Steam Generator | 38.30 | 0.87 | 628.0 | 240.2 | 388 |
| Heat Exchanger (ORC) | 13.18 | 0.43 | 2100.3 | 322.72 | 2093 |
| Evaporator | 77.40 | 27.40 | 1304.4 | 1303 | 381.5 |
| Condenser (Ejector) | 37.72 | 4.60 | 4716 | 1776 | 2940 |
| Ejector | 0.0 | 5.72 | 5876 | 0.0 | 5876 |
| Expansion valve | 73.65 | 1.07 | 1.9 | 0.6 | 1.4 |
| Whole plant | 20.18 | 26.07 | 484,577 | 97,907 | 386,672 |