. 2025 Aug 22;14(8):721–734. doi: 10.1302/2046-3758.148.BJR-2024-0412.R1

Table III.

Results of finite element analysis and biomechanical experiments. All data are shown as mean (SD) unless otherwise stated.

Experimental methods FEA (500 N) Biomechanical experiments
Group Max displacement 0° (mm) Max displacement 45° (mm) Max stress 0° (internal fixations, MPa) Max stress 45° (internal fixations, MPa) Max stress 0° (patellar, MPa) Max stress 45° (patellar, MPa) Static
(500 N, mm)
Fatigue (200 ± 120 N, 1,000 cycles, mm) Fatigue (200 ± 120 N, 10,000 cycles, mm)
CB-H 0.76 (0.17) 0.21 (0.07) 325.09 (72.31) 194.82 (80.64) 114.42 (47.87) 61.12 (23.17) 1.31 (0.06) 1.11 (0.14) 1.35 (0.16)
CB-T 0.81 (0.21) 0.24 (0.07) 318.81 (72.24) 204.37 (49.94) 133.61 (49.38) 72.54 (45.88) 1.88 (0.13) 1.64 (0.32) 1.73 (0.35)
CB-S 0.39 (0.14) 0.19 (0.06) Median 1,098.00
(IQR 919.50 to
1107.00)
419.04 (107.22) 273.41 (64.53) 104.81 (66.63) 1.17 (0.08) 0.73 (0.08) 0.80 (0.08)
TBWC 0.71 (0.34) 0.15 (0.04) 1,193.47 (111.54) 631.63 (262.45) 208.03 (73.46) 96.12 (11.72) 2.09 (0.22) 1.71 (0.08) 1.78 (0.10)

CB-H, candy box technique combined with high-strength suture and Nice knot; CB-S, candy box technique combined with steel wires; CB-T, candy box technique combined with tendon sutures and Nice knot; FEA, finite element analysis; TBWC, tension-band wiring combined with cerclage wiring.