Table 2.
Results of the models based on enhanced CT imaging
| Model | Metrics | Balanced_accuracy | AUC | Specificity | Sensitivity | F1 score |
|---|---|---|---|---|---|---|
| Radiomics model | Training set | 0.689 (0.644–0.724) | 0.857 (0.804–0.900) | 0.406 (0.340–0.468) | 0.971 (0.928–1.000) | 0.573 (0.504–0.634) |
| Internal validation set | 0.634 (0.556–0.712) | 0.781 (0.680–0.875) | 0.402 (0.297–0.505) | 0.867 (0.741–0.970) | 0.556 (0.444–0.652) | |
| External validation set | 0.665 (0.515–0.813) | 0.711 (0.524–0.872) | 0.565 (0.360–0.773) | 0.765 (0.556–0.944) | 0.65 (0.457–0.810) | |
| Clinical model | Training set | 0.656 (0.597–0.715) | 0.786 (0.597–0.715)) | 0.941 (0.907–0.971) | 0.371 (0.258–0.486) | 0.872 (0.838–0.903) |
| Internal validation set | 0.737 (0.646–0.824) | 0.836 (0.646–0.824) | 0.908 (0.844–0.958) | 0.567 (0.390–0.739) | 0.883 (0.830–0.926) | |
| External validation set | 0.662 (0.523–0.794) | 0.733 (0.523–0.794) | 0.913 (0.773–1.000) | 0.412 (0.188–0.650) | 0.778 (0.640–0.885) | |
| Clinincal-radiomics model | Training set | 0.794 (0.729–0.851) | 0.910 (0.729–0.851) | 0.931 (0.896–0.963) | 0.657 (0.529–0.763) | 0.908 (0.876–0.936) |
| Internal validation set | 0.832 (0.747–0.911) | 0.876 (0.747–0.911) | 0.931 (0.872–0.978) | 0.733 (0.565–0.885) | 0.920 (0.878–0.959) | |
| External validation set | 0.684 (0.555–0.802) | 0.821 (0.555–0.802) | 0.957 (0.850–1.000) | 0.412 (0.182–0.636) | 0.800 (0.654–0.897) |