Onset detection error (mean ± SEM) for different algorithms across various SNR levels for white noise.

Algorithm SNR 0 SNR 5 SNR 10 SNR 15
Baseline 0.569 ± 0.106 0.385 ± 0.082 0.186 ± 0.042 0.090 ± 0.019
Noisereduce (ours) 0.192 ± 0.065 0.187 ± 0.058 0.124 ± 0.034 0.069 ± 0.019
Wiener 0.297 ± 0.063 0.237 ± 0.052 0.197 ± 0.054 0.080 ± 0.024
Savitzky-Golay 0.242 ± 0.058 0.201 ± 0.045 0.169 ± 0.044 0.090 ± 0.023