Table 8.
Summary of direct and indirect measurement components and their associated uncertainties.
| S.no | Parameter | Type | Uncertainty (%) | Source |
|---|---|---|---|---|
| 1 | Ambient temperature | Direct | ± 0.4 | Measured using calibrated thermocouples |
| 2 | Surface temperature of heat sink | Direct | ± 0.75 | The sensor accuracy and placement |
| 3 | Temperature of PCM | Direct | ± 0.85 | Multiple sensors used within PCM volume |
| 4 | Input power | Direct | ± 2.4 | Power = voltage × current |
| 5 | Voltage | Direct | ± 0.06 | Measured using multimeters loggers |
| 6 | Current | Direct | ± 0.2 | Ammeters |
| 7 | Thermal conductivity of PCM | Indirect | ± 2 | Measured via steady-state methods |
| 8 | Specific heat capacity | Indirect | ± 3 | DSC calibration |
| 9 | Latent heat of PCM | Indirect | ± 3.5 | Derived from DSC |
| 10 | Heat flux | Indirect | ± 4.1 | Derived from temperature gradients |
| 11 | Mass of PCM | Direct | ± 0.5 | Precision scales required |
| 12 | Density of PCM | Indirect | ± 1.5 | Calculated from mass and volume |
| 13 | Volume of PCM | Direct | ± 0.75 | Determined geometrically |
| 14 | Heat transfer coefficient | Indirect | ± 12.5 | Estimated using correlations |
| 15 | Thermal resistance | Indirect | ± 6.5 | Derived from temperature difference and heat input |
| 16 | Thermal diffusivity | Indirect | ± 5 | Inferred from material tests |
| 17 | Melting point of PCM | Direct | ± 0.5 | Accurate from DSC |