Skip to main content
. 2025 Aug 22;15:30842. doi: 10.1038/s41598-025-03660-x

Table 8.

Summary of direct and indirect measurement components and their associated uncertainties.

S.no Parameter Type Uncertainty (%) Source
1 Ambient temperature Direct  ± 0.4 Measured using calibrated thermocouples
2 Surface temperature of heat sink Direct  ± 0.75 The sensor accuracy and placement
3 Temperature of PCM Direct  ± 0.85 Multiple sensors used within PCM volume
4 Input power Direct  ± 2.4 Power = voltage × current
5 Voltage Direct  ± 0.06 Measured using multimeters loggers
6 Current Direct  ± 0.2 Ammeters
7 Thermal conductivity of PCM Indirect  ± 2 Measured via steady-state methods
8 Specific heat capacity Indirect  ± 3 DSC calibration
9 Latent heat of PCM Indirect  ± 3.5 Derived from DSC
10 Heat flux Indirect  ± 4.1 Derived from temperature gradients
11 Mass of PCM Direct  ± 0.5 Precision scales required
12 Density of PCM Indirect  ± 1.5 Calculated from mass and volume
13 Volume of PCM Direct  ± 0.75 Determined geometrically
14 Heat transfer coefficient Indirect  ± 12.5 Estimated using correlations
15 Thermal resistance Indirect  ± 6.5 Derived from temperature difference and heat input
16 Thermal diffusivity Indirect  ± 5 Inferred from material tests
17 Melting point of PCM Direct  ± 0.5 Accurate from DSC