Table 2.
Mean and standard deviation of depth of material loss (mm.) in different types of HCSCs between immersion periods.
| T1 | T2 | T3 | T4 | T5 | |
|---|---|---|---|---|---|
| ProRoot MTA | 0.23 ± 0.13Aa | 0.28 ± 0.12Ab | 0.31 ± 0.11Ac | 0.35 ± 0.08Ad | 0.35 ± 0.05Ad |
| Biodentine | 0.16 ± 0.03Aa | 0.18 ± 0.03Bb | 0.24 ± 0.03Bc | 0.27 ± 0.04Bd | 0.31 ± 0.04Bc |
| ERRM-FSP | 0.02 ± 0.02Ba | 0.05 ± 0.17Ca | 0.09 ± 0.02Cb | 0.11 ± 0.02Cc | 0.13 ± 0.02Cd |
T1: at 15 min after root-end filling, T2: at 24 h, T3: at 7 days, T4: at 14 days, T5 at 30 days.
Different upper-case letters in the same column indicated statistically significant differences among materials (p < 0.05). Different lower-case letter in the same row indicated statistically significant differences between immersion periods (p < 0.05).