Roof pre-splitting parameters for the 10202 gob-side entry retained.

Parameters Value
Pre-splitting depth 13 m
Dip to the goaf angle 15°
Borehole spacing 500 mm
Borehole diameter 50 mm
Explosive type

No.3 emulsion

explosive

Charge quantity in a

single borehole

5.6 kg
Detonation method Direct priming
Sealing length 2.5 m