Skip to main content
. 2025 Aug 25;10:56. doi: 10.1186/s41181-025-00358-3

Table 2.

Structural parameters of the RFQ-DTL design (Xia et al. 2025)

Structure Length (m) Energy interval (MeV)
RFQ 3.8 0.02–2.11
DTL 1 0.52 2.11–3.28
DTL 2 0.81 3.28–4.92
DTL 3 1.01 4.92–7.03
DTL 4 1.26 7.03–9.37
DTL 5 1.42 9.37–12.01
DTL 6 1.51 12.01–14.86
DTL 7 1.64 14.86–17.92

The overall energy interval is 17.9 MeV and the total length of the accelerator is 11.97 m