Skip to main content
. 2025 Aug 7;7(16):10416–10429. doi: 10.1021/acsapm.5c01101

5. Permeability of the Annealed Electrospun Biopaper Samples: Pure PHBV, PHBV + Res, PHBV/ChCl:EG, PHBV/ChCl:EG + Res.

film WVP × 1014 (kg·m·m–2·Pa–1·s–1) OP × 1019(m3.m·m–2·Pa–1·s–1)
pure PHBV 0.29 ± 0.00 2.16 ± 0.01
PHBV + Res 0.23 ± 0.05 >1000
PHBV/ChCl:EG 0.68 ± 0.04 5.93 ± 0.24
PHBV/ChCl:EG + Res 0.59 ± 0.01 6.64 ± 0.05
a-c

Different letters in the same column indicate a significant difference among the samples (p < 0.05).