Abstract
Liquid chromatography (LC) and mass spectrometry (MS) are two critical components in proteomics. Advances in methods for both LC and MS have significantly enhanced protein identification and quantifications of limited amount proteins, particularly at the picogram- to nanogram-level of proteins. In this study, we explored various LC conditions and MS platforms to optimize protein identification and quantification using data-independent acquisition (DIA). Our investigation focused on evaluating the sensitivity for protein identification, reproducibility of quantification, and robustness across multiple models, specifically focused on analyzing proteins at pico- to nano-gram levels, with an emphasis on single-cell proteomics. We further applied our approach for proteomic analysis of HeLa single cells. Overall, we identified and quantified over 6,300 proteins from single-cell level of peptides with a coefficient of variation (CV) of less than 20%, and over 5,000 proteins from proteins isolated from single HeLa cells. Finally, we analyzed docetaxel treated and non-treated PC3 cells to reveal proteome changes at single-cell level. This study provides a comprehensive technical evaluation for LC-MS methods in protein identification and quantification for analytical applications involving single-cell proteomics from the picogram to the nanogram level of proteins.
Keywords: LC-MS, data independent acquisition, limited amount peptide input, single-cell proteomics, drug treatment
Liquid chromatography (LC) and mass spectrometry (MS)-based proteomics aims to achieve comprehensive and quantitative measurement of the proteome1, 2, from a single-cell to bulk tissue analysis3,4, equivalent to peptide analysis at picogram to microgram levels5. Tremendous efforts have been devoted to quantitative characterization in proteomics analysis of bulk tissues6, primarily through data-dependent acquisition (DDA) approach7–10 and/or data-independent acquisition (DIA) approaches11–13. In the DDA method of single cell proteomics, multiplexed isobaric tagging channels are used to label different cells, which are then pooled together for DDA-MS analysis. During this process, precursor ions are sequentially selected by the instrument14, resulting in identification and quantifications of certain peptides or proteins while others may be missed in each LC-MS/MS analysis. In addition, the quantification of the identified peptides or proteins are less reliable for low abundant peptides or proteins and can be potentially affected by interference from co-isolated peptides15, especially in single-cell level analyses16. The DIA-MS approach analyzes individual samples and fragments all precursor ions simultaneously without preselection12, 17. DIA approach can generate reproducible18, 19, comprehensive, and quantitative datasets at reduced instrument time and low cost20, 21, making it a widely adopted approach in single-cell proteomics for biological and clinical studies22–24.
Significant efforts have been made to optimize the DIA method, incorporating multiple strategies to enhance peptide separation and improve protein identification. These efforts include the use of additional ion separation dimensions25, 26, refinement of LC gradients27, 28 and multidimensional fractionation29. Further advancements involve the optimization of spectral libraries for more accurate protein identification30–32, the development of advanced data acquisition strategies to improve data quality33, and the integration of new algorithms for precise and efficient data analysis34–37. In our recent work, we achieved the identification and quantification of over 10,000 proteins in a single run within less than one hour using DIA for bulk tissue analysis38. At the single-cell level, by utilizing proper LC gradients, optimized spectral libraries, and advanced data acquisition strategies, we demonstrated the ability to identify several hundred to over a thousand proteins from single-cell samples32, 39. Further improvements in single-cell proteomics have been reported by other groups, with studies showing the feasibility of identifying thousands of proteins in single-cell proteomics40–42. Nevertheless, achieving comprehensive proteome coverage for single-cell proteomics and low-input of samples remains a significant challenge.
Benefiting from the very high frequency of the time of flight (TOF) detector and additional ion mobility separation provided by trapped ion mobility separation (tims), timsTOF instruments have been widely utilized for DIA studies25, 38, 39, 43, 44, as it enables the collection of a large number of precursor ions45. However, a comprehensive evaluation of these platforms under different analytical conditions for DIA-MS analysis at the single-cell level remains limited. In this study, we evaluated different LC methods for DIA-MS analysis of low sample amount, focusing on peptide inputs at the picogram to nanogram level. Our optimized workflow enabled the identification and quantification of approximately 3,500 proteins from as little as 15 pg of peptides derived from NCI-7 cell lines46. We analyzed docetaxel treated and non-treated PC3 cells to reveal the biological changes at single-cell level and to demonstrate the heterogeneous responses to treatment. Notably, at higher peptide inputs, such as 250 pg and 8 ng, the workflow exhibited superior performance, achieving reproducible and quantitative identification of over 6,000 and nearly 9,000 proteins, respectively. This study provides a comprehensive technical guide for optimizing LC-MS workflows for single-cell level proteomics using optimal LC-MS, enabling broad applications in high-sensitivity proteomics research.
Materials and Methods
timsTOF-HT Settings
Proteomic analyses were conducted using DIA-MS on a timsTOF-HT (Bruker) coupled with an Evosep One (Evosep). Peptide samples were separated using three different Evosep methods: 100/60 samples per day (SPD) with a PepSep C18 column (8 cm × 100 μm × 3 μm), 30 SPD with a PepSep C18 column (15 cm × 150 μm × 1.5 μm), and Whispher Zoom 40 SPD (WZ-40 SPD) with a PepSep C18 column (15 cm × 75 μm × 1.9 μm) as well as AURORA ELITE C18 column (15 cm × 75 μm × 1.7 μm). All LC methods employed were established protocols by Evosep. For the TIMS on the QTOF, we set a mobility range of 0.70–1.45 V·s/cm2 and a mass range of 100–1700 m/z with dia-PASEF scan mode. An accumulation time of 166 ms was used with high-sensitivity detection enabled. In addition, collision energy settings are 20 eV at 0.60 V·s/cm2 and 59 eV at 1.60 V·s/cm2. The dia-PASEF configuration inclusded a mass range of 275 – 1580 Da and a mobility range of 0.71 – 1.45 1/K0.
timsTOF-Ultra2 Settings
Proteomic analyses were performed using the Evosep system coupled with the timsTOF Ultra2 (Bruker) LC-MS platform. Peptide separation was achieved using the Evosep WZ-40 SPD LC method with an AURORA ELITE C18 column (15 cm × 75 μm × 1.7 μm). The ion mobility range was set between 0.66 and 1.42 V·s/cm2, and the mass range covered 100–1700 m/z, operating in dia-PASEF scan mode. A 100 ms accumulation time was employed, with collision energy settings optimized at 20 eV for 0.60 V·s/cm2 and 59 eV for 1.60 V·s/cm2. The dia-PASEF configuration included one MS1 ramp, eight MS/MS ramps, and 24 MS/MS windows spanning a mass range of 400–1000 Da and a mobility range of 0.64–1.37 1/K0.
PC3 Cell Docetaxel Treatment
PC3 cells were cultured under standard tissue culture conditions (37°C, 5% CO2) in Roswell Park Memorial Institute (RPMI) 1640 Medium (Gibco, 11875093) supplemented with 10% fetal bovine serum (FBS) and 1% Penicillin-Streptomycin (Pen/Strep). For docetaxel (Selleck, S1148) treatments, PC3 cells were treated with or without 1 or 10 nM docetaxel for 72 h, respectively. After the treatment, the supernatants were collected and centrifuged to collect the floating PC3 cells. The PC3 cells on the culture plates were washed with PBS and initially trypsin digested to detach the PC3 cells from the culture plates and collected.
Single Cell Sample Preparation for NCI-7 Diluted Peptides and Single Cells
NCI-7 cells were utilized as reference materials. Peptides from NCI-7 cells were prepared following the CPTAC protocol46. Briefly, 1×10^6 cells were lysed in 8M urea, reduced using 10 mM DTT, and alkylated with 20 mM IAA. The proteins were then digested with trypsin, and the resulting peptides were serially diluted across six dilution points, ranging from 8 ng to 15 pg in 0.05% DDM (n-dodecyl ß-D-maltoside, Sigma Aldrich) water solution.
Single cells were isolated using the CellenOne® system41, 42, which allows for precise manipulation of individual cells through real-time imaging that assesses cell size. Cultured HeLa and non-treated/treated PC3 cells were diluted in 1x PBS to a concentration of 200 cells/μL and isolated based on a cell size range of 22 to 25 μm and 20 to 38 μm in diameter, respectively. Each single cell was dispensed into a well of a 384-well plate (Cat# 951040589, Eppendorf) containing 1 μL of lysis buffer, consisting of 0.1% DDM, 0.02% LMNG (Lauryl maltose neopentyl glycol, Anatrace), 5 mM TCEP (Tris 2-carboxyethyl phosphine hydrochloride, Thermo Scientific) and 10 ng of LysC/Trypsin mixture in 100 mM TEAB (Triethylammonium bicarbonate, Thermo Scientific)47. The plate was sealed using an adhesive plate seal (LabViva) to prevent evaporation and briefly centrifuged at 1000 × g for 5 minutes, followed by overnight incubation at 37°C. The resulting peptide samples were acidified with 0.5 μL of 0.5% formic acid and stored at −80°C until ready for LC-MS analysis. The Evotips were prepared by washing and activating them according to the manufacturer’s instructions prior to peptide loading. Following peptide loading, the Evotips were thoroughly washed with 20 μL of 0.1% formic acid to ensure sample desalting before LC-MS/MS analysis.
DIA-MS Data Analysis
Proteomic raw data from TimsTOF HT was processed using Spectronaut (Ver 19.5.) with the directDIA approach (FASTA database downloaded 09/15/2023, UniproKB reviewed, 20,426 entries). Briefly, raw DIA data were directly used for analysis using non-cross-normalized mode. All co-searched datasets were included in the supplementary tables. The following processing parameters were used for all software tools: a maximum of two missed cleavages and cysteine carbamidomethylation (+57.0215 Da) as the fixed modification. The FDR was set at 1% using the target-decoy strategy at both the peptide and protein levels. Microsoft Excel (Version 16.9), Prism 10, and timsTOF visualization tool from GitHub (https://github.com/zack-kirsch/timsTOF_visualization_tool) were utilized for data analysis.
Results and Discussion
Enhanced Proteome Coverage Through Optimized LC Conditions for Single-Cell Level Peptide Input.
To optimize LC conditions for single-cell level or small-scale material characterization, we compared the regular 100 SPD, 60 SPD, 30 SPD LC method with the Whisper Zoom 40 SPD (WZ-40 SPD) method on the timsTOF-HT. We also evaluated regular C18 column with ZDV sprayer (PepSep C18 column) and zero dead volume pre-column without additional sprayer (AURORA ELITE C18 column). Serial dilutions of NCI-7 peptides, ranging from 62 pg to 8 ng, were analyzed. As shown in Fig. 1A, protein identification significantly improved with the WZ-40 SPD LC method and PepSep C18 column compared to the other regular LC approaches, demonstrating superior protein identification at low peptide input levels. Specifically, at the single-cell level (approximately 62 pg of peptides)32, 48, the 30 SPD LC method identified 1,400 proteins on average, while the WZ-40 SPD LC method identified 2,100 proteins on average. At the 8 ng of peptide level, the 30 SPD LC method identified nearly 5,700 proteins, whereas the number of 6,100 proteins identified by the WZ-40 SPD LC method. These results indicate the WZ-40 SPD LC method as a better choice for single-cell and low-input peptide profiling. Furthermore, we compared the PepSep C18 column with the AURORA ELITE C18 column using the WZ-40 SPD LC method, and the latter demonstrated more than 50 % increase in protein identification (Fig. 1A). We chose WZ-40 SPD LC method combined with AURORA ELITE C18 column for further analysis on both timsTOF-HT and timsTOF-Ultra2 instruments.
Figure 1.

Assessment of proteome characterization with low peptide input amounts. (A) Evaluation of LC conditions and columns for analyzing low-input NCI-7 peptides using timsTOF HT revealed that the WZ40 SPD method outperformed other three LC methods, especially in single-cell peptide level (250 pg of peptides). (B) Performance for protein identification using WZ40 SPD with timsTOF HT or timsTOF Ultra2 for low-input NCI-7 peptide analysis.
Comparison of timsTOF-HT and timsTOF-Ultra2 at Low Peptide Inputs.
The NCI-7 cell peptide dilutions were analyzed on the timsTOF-HT and timsTOF-Ultra2 instruments, with injection amounts ranging from 15 pg to 8 ng using the WZ-40 SPD LC method (Fig. 1B). At 15 pg peptide input, the timsTOF-HT quantified around one thousand proteins, whereas the timsTOF-Ultra2 quantified over 3,300 proteins, demonstrating its superior sensitivity for subcellular-level analysis. The timsTOF-Ultra2 identified approximately 4,000 proteins at 62 pg, 6,200 proteins at 250 pg, 7,800 proteins at 1 ng, and 8,800 proteins at 8 ng. In contrast, the timsTOF-HT identified 3,400 proteins at the 62 pg, 5,000 proteins at 250 pg, 7, 000 proteins at 1 ng, and 7,600 proteins at 8 ng. More peptides were characterized on timsTOF-Ultra2 as well (Figs. S1). These results highlight the sensitivity of timsTOF-Ultra2 for indepth proteome characterization at low peptide inputs, ranging from the subcellular level to the hundred-cell level, while the timsTOF-HT performs comparably at higher peptide inputs, starting at 62 ng.
Quantification Reproducibility, and Dynamic Range of Single-Cell Proteome Analysis.
To evaluate the robustness of single-cell level analysis, we examined the reproducibility of DIA-MS. Each condition included three replicate injections with peptide amounts ranging from 15 pg to 8 ng. The CV was calculated for the entire proteome (Fig. 2). For the NCI-7 cell line samples, the CV distributions for 15 pg to 250 pg peptide injections on the timsTOF-HT instrument exhibited similar patterns, with median CVs larger than 20% (Fig. 2A). As the peptide injection amount increased, the median CV progressively decreased, falling below 20% starting from 250 pg injections in the cell line samples. The 8 ng peptide injections produced the best median CV values, achieving 10 % for NCI-7 peptides on the timsTOF-HT. For the timsTOF-Ultra2, the median CV for 15 pg NCI-7 peptide injections was 29.0%, all other median CV distributions were below 20% (Fig. 2B), with the timsTOF-Ultra2 achieving an impressive median CV of 4.1% for 8 pg NCI-7 peptide injections. Both the timsTOF-HT and timsTOF-Ultra2 instruments exhibited exceptional reproducibility at peptide inputs of 8 ng.
Figure 2.

Quantification reproducibility of low amount peptide input. (A) CV distribution of diluted NCI-7 peptides on timsTOF-HT. (B) CV distribution of diluted NCI-7 peptides on timsTOF-Ultra2.
To evaluate the quantification capabilities of these two instruments for low sample input analysis, we plotted box plots of protein DIA-MS ratio values across all tested conditions (Figs. S2A, S2B). The median quantitative fold-change values of all proteins increased with sample input and gradually approximated the true input ratios. Consistent with reproducibility findings, peptide inputs above 1 ng provided better quantitative accuracy. Similarly, NCI-7 peptide inputs above 1 ng displayed a broader dynamic range, exceeding 5 orders of magnitude (Figs. S2C, S2D). The highest dynamic range was observed both at 8 ng NCI-7 peptide input on the timsTOF-HT and 1 ng NCI-7 peptide input on the timsTOF-Ultra2, achieving dynamic ranges of 4.8 log and 5.0 log orders, respectively.
Proteome Profiling of Single Cancer Cells.
We used these LC-MS/MS conditions for real single-cell measurements. Single HeLa cells were prepared, with 62 single cells analyzed on timsTOF-HT and 36 single cells analyzed on timsTOF-Ultra2. Single-cell analyses were conducted using the WZ-40 SPD LC method (Fig. 3A). On the timsTOF-HT, we quantified about 14,000 peptides and 2,500 proteins per single HeLa cell. On the timsTOF-Ultra2, we quantified over 26,000 peptides and 4,400 proteins on average per single HeLa cell. These results were consistent with the peptide dilution analyses.
Figure 3.

Evaluation of reproducibility in single-cell proteomics analysis of HeLa cells. (A) Number of protein identifications from individual HeLa cells. (B) Median CVs across different cell numbers on timsTOF-HT. (C) Examples of high expressed proteins with high CVs on timsTOF-HT.
A total of 1,002 proteins were consistently identified across all 62 cells, and 2,417 proteins were quantified in more than half of the cells on timsTOF-HT. Using the timsTOF-Ultra2, 2,333 proteins were reproducibly identified, and 4,200 proteins were quantified in more than half of total cells, with median CV values of 44.1% and 35.4%, respectively. (Fig. 3A and Fig. S3A). Most proteins identified on timsTOF-HT can also be found on timsTOF-Ultra2 (Fig. S3B). These results showed higher median CV values of HeLa single cell on both instruments than peptide dilution samples, indicating the differences among the cells. Single HeLa cell analysis demonstrated superior performance on the timsTOF-Ultra2 compared to the TimsTOF-HT.
To evaluate the biological heterogeneity of single HeLa cells, we examined the reproducibility across the single cell, 2 cells, 4 cells, 8 cells, and 16 cells on timsTOF-HT. The median CV decreased as the number of characterized cells increased, reaching below 20% when 16 cells were measured together (Fig. 3B). These results indicate that the single cell exhibits strong heterogeneity, and to avoid this, it may be necessary to measure multiple cells of the same cell type. To investigate which types of proteins exhibit high variability in single cells, particularly among high-abundance proteins, we analyzed the top 100 proteins with the highest median intensity that had a CV greater than 30%. The high-abundance variable proteins included cytoskeleton-associated proteins involved in maintaining cell morphology and architecture, such as ANXA2, VIM, ACTA2 and KRT8, along with histone proteins involved in transcription (H2BC13 and H1–2) and metabolic enzymes (PHGDH and PKM). The CV of those high-abundance proteins gradually decreased, when more cells were analyzed (Fig. 3C). However, we could not observe the same phenomena in the peptide serial dilution measurement (Fig. S3C). This observation suggests that the high variability of certain proteins was unlikely to originate from the data generation process.
To further explore these high-abundance proteins, we performed additional analyses using those proteins from varying numbers of isolated HeLa cells (Fig. S3D). The protein intensity increased as more cells were measured. The initial single-cell data suggested that high variability might result from cell heterogeneity, subsequent analyses of multi-cell proteomes confirmed that these variations were consistent across different cell numbers. This consistency supports a biological origin for the observed variability in single cell high-abundance proteins, rather than sample preparation processes.
These findings gave new insights into the dynamic variability of tumor cells, highlighting the heterogeneity of HeLa cells. The timsTOF-Ultra2 excelled in achieving deeper proteome coverage and higher reproducibility at single cell level. This analysis underscores the significant advancements in single-cell proteomics made possible by cutting-edge instrumentation, opening new approach for exploring cellular heterogeneity and advancing functional proteomics research.
We applied this advanced technique to systematically investigate the proteomic and morphological effects of the PC-3 prostate cancer cell line to chemotherapy stress. Specifically, PC-3 cells were treated with 1 nM (low dose) and 10 nM (high dose) docetaxel for 72 hours. As shown in Fig. 4A, notable morphological differences were observed across treatment conditions. Adherent (live) cells exposed to the high-dose treatment exhibited the largest cell size, suggesting potential cytoskeletal remodeling or possible polyploidization as an adaptive response to chemotherapeutic stress. In contrast, cells treated with the low dose displayed an intermediate size, while untreated cells maintained the smallest and most uniform morphology. This size increase in high-dose surviving cells may reflect a survival strategy, enabling them to withstand drug-induced cytotoxicity. Consistent with these morphological observations, proteomic analysis revealed distinct differences in protein identification across the various experimental conditions (Fig. 4B). High dose treated live cells exhibited the highest number of identified proteins. Conversely, floating (dead or dying) cells from the high-dose group showed the lowest number of identified proteins, likely due to extensive cellular damage, loss of membrane integrity, and degradation of intracellular components, which collectively lead to poor proteome coverage. In addition to protein abundance differences, we evaluated proteomic variability across conditions by calculating the CV for detected proteins (Fig. 4C). Interestingly, live cells subjected to high-dose treatment displayed the highest median CV among all experimental groups, reflecting increased heterogeneity in protein expression. This elevated variability may represent a hallmark of adaptive resistance mechanisms, wherein a subset of cells dynamically adjusts their proteomic landscape to evade the cytotoxic effects of chemotherapy. Such heterogeneity is a known contributor to drug resistance and tumor relapse in clinical settings. Together, these findings showed that high-dose chemotherapy selectively enriches for a heterogeneous protein expression of surviving cells, underscoring the complexity of therapeutic resistance at the single cell level.
Figure 4.

Single cell analyses for docetaxel treated PC3 cells. (A) Cell size of docetaxel treated PC3 cells. (B) Protein identifications for all conditions. (C) CV distribution of all condition.
Conclusion
We evaluated LC conditions in combination with MS instruments to achieve high-sensitivity protein identification across peptide inputs ranging from 15 pg to 8 ng using the DIA approach. This workflow demonstrated versatility across diverse peptide input amounts. At the single-cell and low-peptide input level, the WZ-40 SPD LC method combined with zero dead volume pre-column without additional sprayer column provided best performance. The timsTOF-Ultra2 demonstrated the ability to profile subcellular quantities of 15 pg peptides, identifying over 3,300 proteins. Furthermore, with a consistent WZ-40 SPD LC system and the timsTOF-Ultra2, we demonstrated a proteome coverage from subcellular to hundred-cell level analyses, identifying 3,300 to 8,800 proteins. Single HeLa cell and docetaxel treated PC3 cell profiling revealed dynamic variability in protein expression, emphasizing the potential of advanced instrumentation to uncover cellular heterogeneity and differential drug responses while advancing the field of single-cell proteomics. This work paves the way for future studies leveraging state-of-the-art instrumentation to explore cellular diversity, functional proteomics, drug response mechanism, and biomarker discovery with unprecedented depth and precision.
Supplementary Material
ASSOCIATED CONTENT
Supporting Information
The Supporting Information is available free of charge on the ACS Publications website.
The supplementary figures were provided in the Supporting Information.
All data matrices related to this study were provided in supplementary table (Table SI.xlsx) of the Supporting Information.
ACKNOWLEDGMENT
This work was supported by the Clinical Proteomic Tumor Analysis Consortium (CPTAC, U24CA271079) the Early Detection Research Network (EDRN, U2CCA271895) and Pancreatic Cancer Detection Consortium (PCDC, U01CA274514) from National Institutes of Health, National Cancer Institute. The Bruker Daltonics Mass Spectrometry demo facility (Billerica, Massachusetts, USA) provided the timsTOF-Ultra2 instrument. Toc image was generated by BioRender.com
REFERENCES
- (1).Altelaar AF; Munoz J; Heck AJ Next-Generation Proteomics: towards an Integrative View of Proteome Dynamics. Nat Rev Genet 2013, 14 (1), 35–48. DOI: 10.1038/nrg3356. [DOI] [PubMed] [Google Scholar]
- (2).Aebersold R; Mann M Mass-Spectrometric Exploration of Proteome Structure and Function. Nature 2016, 537 (7620), 347–355. DOI: 10.1038/nature19949. [DOI] [PubMed] [Google Scholar]
- (3).Marx V A Dream of Single-Cell Proteomics. Nat Methods 2019, 16 (9), 809–812. DOI: 10.1038/s41592-019-0540-6. [DOI] [PubMed] [Google Scholar]
- (4).Vistain LF; Tay S Single-Cell Proteomics. Trends Biochem Sci 2021, 46 (8), 661–672. DOI: 10.1016/j.tibs.2021.01.013. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (5).Ctortecka C; Mechtler K The Rise of Single-Cell Proteomics. Anal Sci Adv 2021, 2 (3–4), 84–94. DOI: 10.1002/ansa.202000152. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (6).Wang Y; Jin RU; Xu J; Lin DC; Sun Z; Xu Y; Li QK; Zhang H Harnessing Technologies to Unravel Gastric Cancer Heterogeneity. Trends Cancer 2025. DOI: 10.1016/j.trecan.2025.04.011. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (7).Mun DG; Bhin J; Kim S; Kim H; Jung JH; Jung Y; Jang YE; Park JM; Kim H; Jung Y; et al. Proteogenomic Characterization of Human Early-Onset Gastric Cancer. Cancer Cell 2019, 35 (1), 111–124.e110. DOI: 10.1016/j.ccell.2018.12.003. [DOI] [PubMed] [Google Scholar]
- (8).Gao Q; Zhu H; Dong L; Shi W; Chen R; Song Z; Huang C; Li J; Dong X; Zhou Y; et al. Integrated Proteogenomic Characterization of HBV-Related Hepatocellular Carcinoma. Cell 2019, 179 (2), 561–577.e522. DOI: 10.1016/j.cell.2019.08.052. [DOI] [PubMed] [Google Scholar]
- (9).Gillette MA; Satpathy S; Cao S; Dhanasekaran SM; Vasaikar SV; Krug K; Petralia F; Li Y; Liang WW; Reva B; et al. Proteogenomic Characterization Reveals Therapeutic Vulnerabilities in Lung Adenocarcinoma. Cell 2020, 182 (1), 200–225.e235. DOI: 10.1016/j.cell.2020.06.013. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (10).Chen YJ; Roumeliotis TI; Chang YH; Chen CT; Han CL; Lin MH; Chen HW; Chang GC; Chang YL; Wu CT; et al. Proteogenomics of Non-smoking Lung Cancer in East Asia Delineates Molecular Signatures of Pathogenesis and Progression. Cell 2020, 182 (1), 226–244.e217. DOI: 10.1016/j.cell.2020.06.012. [DOI] [PubMed] [Google Scholar]
- (11).Schubert OT; Röst HL; Collins BC; Rosenberger G; Aebersold R Quantitative Proteomics: Challenges and Opportunities in Basic and Applied Research. Nat Protoc 2017, 12 (7), 1289–1294. DOI: 10.1038/nprot.2017.040. [DOI] [PubMed] [Google Scholar]
- (12).Gillet LC; Navarro P; Tate S; Röst H; Selevsek N; Reiter L; Bonner R; Aebersold R Targeted Data Extraction of the MS/MS Spectra Generated by Data-Independent Acquisition: a New Concept for Consistent and Accurate Proteome Analysis. Mol Cell Proteomics 2012, 11 (6), O111.016717. DOI: 10.1074/mcp.O111.016717. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (13).Li Y; Lih TM; Dhanasekaran SM; Mannan R; Chen L; Cieslik M; Wu Y; Lu RJ; Clark DJ; Kołodziejczak I; et al. Histopathologic and Proteogenomic Heterogeneity Reveals Features of Clear Cell Renal Cell Carcinoma Aggressiveness. Cancer Cell 2023, 41 (1), 139–163.e117. DOI: 10.1016/j.ccell.2022.12.001. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (14).Mertins P; Tang LC; Krug K; Clark DJ; Gritsenko MA; Chen L; Clauser KR; Clauss TR; Shah P; Gillette MA; et al. Reproducible Workflow for Multiplexed Deep-Scale Proteome and Phosphoproteome Analysis of Tumor Tissues by Liquid Chromatography-Mass Spectrometry. Nat Protoc 2018, 13 (7), 1632–1661. DOI: 10.1038/s41596-018-0006-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (15).O’Brien JJ; O’Connell JD; Paulo JA; Thakurta S; Rose CM; Weekes MP; Huttlin EL; Gygi SP Compositional Proteomics: Effects of Spatial Constraints on Protein Quantification Utilizing Isobaric Tags. J Proteome Res 2018, 17 (1), 590–599. DOI: 10.1021/acs.jproteome.7b00699. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (16).Cheung TK; Lee CY; Bayer FP; McCoy A; Kuster B; Rose CM Defining the Carrier Proteome Limit for Single-Cell Proteomics. Nat Methods 2021, 18 (1), 76–83. DOI: 10.1038/s41592-020-01002-5. [DOI] [PubMed] [Google Scholar]
- (17).Ludwig C; Gillet L; Rosenberger G; Amon S; Collins BC; Aebersold R Data-Independent Acquisition-based SWATH-MS for Quantitative Proteomics: A Tutorial. Mol Syst Biol 2018, 14 (8), e8126. DOI: 10.15252/msb.20178126. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (18).Collins BC; Hunter CL; Liu Y; Schilling B; Rosenberger G; Bader SL; Chan DW; Gibson BW; Gingras AC; Held JM; et al. Multi-Laboratory Assessment of Reproducibility, Qualitative and Quantitative Performance of SWATH-Mass Spectrometry. Nat Commun 2017, 8 (1), 291. DOI: 10.1038/s41467-017-00249-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (19).Cho KC; Oh S; Wang Y; Rosenthal LS; Na CH; Zhang H Evaluation of the Sensitivity and Reproducibility of Targeted Proteomic Analysis Using Data-Independent Acquisition for Serum and Cerebrospinal Fluid Proteins. J Proteome Res 2021, 20 (9), 4284–4291. DOI: 10.1021/acs.jproteome.1c00238. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (20).Muntel J; Kirkpatrick J; Bruderer R; Huang T; Vitek O; Ori A; Reiter L Comparison of Protein Quantification in a Complex Background by DIA and TMT Workflows with Fixed Instrument Time. J Proteome Res 2019, 18 (3), 1340–1351. DOI: 10.1021/acs.jproteome.8b00898. [DOI] [PubMed] [Google Scholar]
- (21).Thomas SN; Friedrich B; Schnaubelt M; Chan DW; Zhang H; Aebersold R Orthogonal Proteomic Platforms and Their Implications for the Stable Classification of High-Grade Serous Ovarian Cancer Subtypes. iScience 2020, 23 (6), 101079. DOI: 10.1016/j.isci.2020.101079. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (22).Fröhlich K; Fahrner M; Brombacher E; Seredynska A; Maldacker M; Kreutz C; Schmidt A; Schilling O Data-Independent Acquisition: A Milestone and Prospect in Clinical Mass Spectrometry-Based Proteomics. Mol Cell Proteomics 2024, 23 (8), 100800. DOI: 10.1016/j.mcpro.2024.100800. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (23).Huffman RG; Leduc A; Wichmann C; Di Gioia M; Borriello F; Specht H; Derks J; Khan S; Khoury L; Emmott E; et al. Prioritized Mass Spectrometry Increases the Depth, Sensitivity and Data Completeness of Single-Cell Proteomics. Nat Methods 2023, 20 (5), 714–722. DOI: 10.1038/s41592-023-01830-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (24).Petrosius V; Aragon-Fernandez P; Üresin N; Kovacs G; Phlairaharn T; Furtwängler B; Op De Beeck J; Skovbakke SL; Goletz S; Thomsen SF; et al. Exploration of Cell State Heterogeneity using Single-Cell Proteomics through Sensitivity-Tailored Data-Independent Acquisition. Nat Commun 2023, 14 (1), 5910. DOI: 10.1038/s41467-023-41602-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (25).Meier F; Brunner AD; Frank M; Ha A; Bludau I; Voytik E; Kaspar-Schoenefeld S; Lubeck M; Raether O; Bache N; et al. diaPASEF: Parallel Accumulation-Serial Fragmentation Combined with Data-Independent Acquisition. Nat Methods 2020, 17 (12), 1229–1236. DOI: 10.1038/s41592-020-00998-0. [DOI] [PubMed] [Google Scholar]
- (26).Reilly L; Lara E; Ramos D; Li Z; Pantazis CB; Stadler J; Santiana M; Roberts J; Faghri F; Hao Y; et al. A Fully Automated FAIMS-DIA Mass Spectrometry-based Proteomic Pipeline. Cell Rep Methods 2023, 3 (10), 100593. DOI: 10.1016/j.crmeth.2023.100593. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (27).Bache N; Geyer PE; Bekker-Jensen DB; Hoerning O; Falkenby L; Treit PV; Doll S; Paron I; Müller JB; Meier F; et al. A Novel LC System Embeds Analytes in Pre-formed Gradients for Rapid, Ultra-robust Proteomics. Mol Cell Proteomics 2018, 17 (11), 2284–2296. DOI: 10.1074/mcp.TIR118.000853. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (28).Røberg-Larsen H; Lundanes E; Nyman TA; Berven FS; Wilson SR Liquid Chromatography, a Key Tool for the Advancement of Single-Cell Omics Analysis. Anal Chim Acta 2021, 1178, 338551. DOI: 10.1016/j.aca.2021.338551. [DOI] [PubMed] [Google Scholar]
- (29).Cho KC; Clark DJ; Schnaubelt M; Teo GC; Leprevost FDV; Bocik W; Boja ES; Hiltke T; Nesvizhskii AI; Zhang H Deep Proteomics Using Two Dimensional Data Independent Acquisition Mass Spectrometry. Anal Chem 2020, 92 (6), 4217–4225. DOI: 10.1021/acs.analchem.9b04418. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (30).Parker SJ; Venkatraman V; Van Eyk JE Effect of Peptide Assay Library Size and Composition in Targeted Data-Independent Acquisition-MS Analyses. Proteomics 2016, 16 (15–16), 2221–2237. DOI: 10.1002/pmic.201600007. [DOI] [PubMed] [Google Scholar]
- (31).Siyal AA; Chen ES; Chan HJ; Kitata RB; Yang JC; Tu HL; Chen YJ Sample Size-Comparable Spectral Library Enhances Data-Independent Acquisition-Based Proteome Coverage of Low-Input Cells. Anal Chem 2021, 93 (51), 17003–17011. DOI: 10.1021/acs.analchem.1c03477. [DOI] [PubMed] [Google Scholar]
- (32).Wang Y; Lih TM; Chen L; Xu Y; Kuczler MD; Cao L; Pienta KJ; Amend SR; Zhang H Optimized Data-Independent Acquisition Approach for Proteomic Analysis at Single-Cell Level. Clin Proteomics 2022, 19 (1), 24. DOI: 10.1186/s12014-022-09359-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (33).Lou R; Shui W Acquisition and Analysis of DIA-Based Proteomic Data: A Comprehensive Survey in 2023. Mol Cell Proteomics 2024, 23 (2), 100712. DOI: 10.1016/j.mcpro.2024.100712. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (34).Bruderer R; Bernhardt OM; Gandhi T; Miladinović SM; Cheng LY; Messner S; Ehrenberger T; Zanotelli V; Butscheid Y; Escher C; et al. Extending the Limits of Quantitative Proteome Profiling with Data-Independent Acquisition and Application to Acetaminophen-treated Three-Dimensional Liver Microtissues. Mol Cell Proteomics 2015, 14 (5), 1400–1410. DOI: 10.1074/mcp.M114.044305. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (35).Tsou CC; Avtonomov D; Larsen B; Tucholska M; Choi H; Gingras AC; Nesvizhskii AI DIA-Umpire: Comprehensive Computational Framework for Data-Independent Acquisition Proteomics. Nat Methods 2015, 12 (3), 258–264, 257 p following 264. DOI: 10.1038/nmeth.3255. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (36).Ting YS; Egertson JD; Bollinger JG; Searle BC; Payne SH; Noble WS; MacCoss MJ PECAN: Library-Free Peptide Detection for Data-Independent Acquisition Tandem Mass Spectrometry Data. Nat Methods 2017, 14 (9), 903–908. DOI: 10.1038/nmeth.4390. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (37).Guldberg SM; Okholm TLH; McCarthy EE; Spitzer MH Computational Methods for Single-Cell Proteomics. Annu Rev Biomed Data Sci 2023, 6, 47–71. DOI: 10.1146/annurev-biodatasci-020422-050255. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (38).Wang Y; Lih TM; Lee JW; Ohtsuka T; Hozaka Y; Mino-Kenudson M; Adsay NV; Luchini C; Scarpa A; Maker AV; et al. Multi-omic Profiling of Intraductal Papillary Neoplasms of the Pancreas Reveals Distinct Expression Patterns and Potential Markers of Progression. bioRxiv 2024. DOI: 10.1101/2024.07.07.602385. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (39).Woo J; Loycano M; Amanullah M; Qian J; Amend SR; Pienta KJ; Zhang H Single-Cell Proteomic Characterization of Drug-Resistant Prostate Cancer Cells Reveals Molecular Signatures Associated with Morphological Changes. Mol Cell Proteomics 2025, 24 (4), 100949. DOI: 10.1016/j.mcpro.2025.100949. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (40).Matzinger M; Müller E; Dürnberger G; Pichler P; Mechtler K Robust and Easy-to-Use One-Pot Workflow for Label-Free Single-Cell Proteomics. Anal Chem 2023, 95 (9), 4435–4445. DOI: 10.1021/acs.analchem.2c05022. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (41).Mun DG; Bhat FA; Joshi N; Sandoval L; Ding H; Jain A; Peterson JA; Kang T; Pujari GP; Tomlinson JL; et al. Diversity of Post-Translational Modifications and Cell Signaling Revealed by Single Cell and Single Organelle Mass Spectrometry. Commun Biol 2024, 7 (1), 884. DOI: 10.1038/s42003-024-06579-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (42).Ye Z; Sabatier P; van der Hoeven L; Lechner MY; Phlairaharn T; Guzman UH; Liu Z; Huang H; Huang M; Li X; et al. Enhanced Sensitivity and Scalability with a Chip-Tip Workflow Enables Deep Single-Cell Proteomics. Nat Methods 2025, 22 (3), 499–509. DOI: 10.1038/s41592-024-02558-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (43).Skowronek P; Thielert M; Voytik E; Tanzer MC; Hansen FM; Willems S; Karayel O; Brunner AD; Meier F; Mann M Rapid and In-Depth Coverage of the (Phospho-)Proteome With Deep Libraries and Optimal Window Design for dia-PASEF. Mol Cell Proteomics 2022, 21 (9), 100279. DOI: 10.1016/j.mcpro.2022.100279. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (44).Demichev V; Szyrwiel L; Yu F; Teo GC; Rosenberger G; Niewienda A; Ludwig D; Decker J; Kaspar-Schoenefeld S; Lilley KS; et al. dia-PASEF Data Analysis using FragPipe and DIA-NN for Deep Proteomics of Low Sample Amounts. Nat Commun 2022, 13 (1), 3944. DOI: 10.1038/s41467-022-31492-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (45).Silveira JA; Ridgeway ME; Laukien FH; Mann M; Park MA Parallel Accumulation for 100% Duty Cycle Trapped Ion Mobility-Mass Spectrometry. International Journal of Mass Spectrometry 2017, 413, 168–175. DOI: 10.1016/j.ijms.2016.03.004. [DOI] [Google Scholar]
- (46).Clark DJ; Hu Y; Bocik W; Chen L; Schnaubelt M; Roberts R; Shah P; Whiteley G; Zhang H Evaluation of NCI-7 Cell Line Panel as a Reference Material for Clinical Proteomics. J Proteome Res 2018, 17 (6), 2205–2215. DOI: 10.1021/acs.jproteome.8b00165. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (47).Konno R; Ishikawa M; Nakajima D; Endo Y; Ohara O; Kawashima Y Universal Pretreatment Development for Low-input Proteomics Using Lauryl Maltose Neopentyl Glycol. Mol Cell Proteomics 2024, 23 (4), 100745. DOI: 10.1016/j.mcpro.2024.100745. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (48).Zhu Y; Clair G; Chrisler WB; Shen Y; Zhao R; Shukla AK; Moore RJ; Misra RS; Pryhuber GS; Smith RD; et al. Proteomic Analysis of Single Mammalian Cells Enabled by Microfluidic Nanodroplet Sample Preparation and Ultrasensitive NanoLC-MS. Angew Chem Int Ed Engl 2018, 57 (38), 12370–12374. DOI: 10.1002/anie.201802843. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.