Power Consumption Summary for a 24-Hour Sampling Event.

Components Voltage Current Draw Runtime per Day Energy (Wh/day)
Particle Boron LTE 3.3 V 150 mA 24 h 11.88
Peristaltic Pump w/DRV8825 12 V 400 mA 4 min per hour 7.68
eTape 3.3 V 5 mA 24 h 0.40
Water Sensor 5 V 20 mA 24 h 2.40
Total Load ∼ 22.76 Wh/day
Solar Input (10 W panel) 5 h @ 80 % efficiency 40 Wh/day