Table 4.

Summary table listing all publications discussed in this manuscript on ex vivo pancreas perfusion.

Study Animal species/strain Perfusion solution Tubing type/length Use of oxygenators Flow rate Length of perfusion Temperature (°C) Application Functional tests performed Cannulation site
Pancreas
 Benchtop/incubator
  Single-pass method (Pegg, 1982) WAG rats Gelatin polypeptide Haemaccel + 5.4 mM calcium + glucose (5 mM for first hour, 30 mM for second hour) Not described Bubbled oxygen (95% O2, 5% CO2) 2 mL/min 2 h 38°C To test assays for measuring glucose-responsiveness Insulin secretion assay (5 mM vs. 30 mM glucose) Input: Aorta (below superior mesenteric artery)
  Recirculation method (Pegg, 1982) WAG rats Gelatin polypeptide Haemaccel + 5.4 mM calcium + 5 mM glucose Not described Bubbled oxygen (95% O2, 5% CO2) 60 mmHg (pressure) 2 h 38°C To test assays for measuring glucose-responsiveness Insulin secretion assay (5 mM vs. 30 mM glucose) Input: Aorta (below superior mesenteric artery)
  Loubatieres-Mariani, 1980 Wistar rats Krebs–Ringer bicarbonate buffer + 2 g/L purified bovine albumin + 0–3 g/L glucose Not described Bubbled oxygen (93% O2, 7% CO2) 2.4 mL/min 90 min 28°C & 37.5°C To test effect of temperature (hypothermia) on glucose responsiveness Insulin secretion assay (following stimulation with high glucose, tolbutamide, acetylcholine, and glucagon) N/A
  Kojima, 1984 Wistar rats Na+; 131 mEq/1, lactate-: 28 mEq/L, K+: 4 mEq/1, Ca∗: 3 mEq/L, CI-: 110 mEq/1, Dextran 40:30.0 gr/1, glucose: 1 gr/1, pH: 8.2 + 0.2. T Not described Artificial lung 10 mL/min 6 h 4°C (hypothermic) To test the effect of hypothermia, hyperbaria, and oxygenation during pancreas preservation on islet health and function Insulin secretion assay; transplantation into diabetic mice for reversal of diabetes Input: celiac axis
  Klempanauer, 1982 Wistar rats Protide gel solution, fructose-bicarbonate solution, modified cryoprecipitated plasma, Collins' C3 solution, Sack's solution Not described No Not described 24 h 0°C–4°C To demonstrate that a simpler approach, using initial perfusion with a chilled solution, following by storage at 0–4C is superior to other methods for 24 h perfusion N/A Input: Aorta (below superior mesenteric artery)
  Mantke, 2009 Wistar rats Modified Krebs–Ringer bicarbonate Not described 95% O2, 5% CO2 1 mL/min (220 mmHg) 80 min (60 min perfusion time, 20 min equilibration time) 37°C (using heat exchanger) To examine early mechanisms leading to acinar cell injury in acute pancreatitis Amylase, lipase, and lactate dehydrogenase activity Causal aorta (input), portal vein (output). Both cannulated with Teflon tube