Skip to main content
. 2025 Oct 13;15:35661. doi: 10.1038/s41598-025-19530-5

Table 2.

Voltage stress of switches in proposed 17-level inverter.

Switch Voltage stress Switch Voltage stress
Value Per-unit Value Per-unit
S1 2Vdc = 0.25Vo, max 0.25 K2 3Vdc = 0.375Vo, max 0.375
S2 2Vdc = 0.25Vo, max 0.25 T1 6Vdc = 0.75Vo, max 0.75
S3 6Vdc = 0.75Vo, max 0.75 T2 8Vdc = Vo, max 1
S4 6Vdc = 0.75Vo, max 0.75 T3 8Vdc = Vo, max 1
K1 Vdc=0.125Vo, max 0.125 T4 6Vdc = 0.75Vo, max 0.75
Total voltage stress (TVS) Value 48Vdc
Per unit 6