Skip to main content
. 2025 Oct 22;5(4):100296. doi: 10.1016/j.ynirp.2025.100296

Table 2.

Summary statistics of reliability by scan duration. Q1/Q3: first and third quartiles.

Scan Duration (minutes) ICC Statistics
Percentage of Edges with ICCs in Qualitative Benchmark Ranges
Mean SD Median Q1 Q3 Poor (<0.4) Fair (0.4–0.59) Good (0.6–0.74) Excellent (≥0.75)
3 0.17 0.30 0.19 −0.03 0.39 74.06 17.34 5.48 1.12
4 0.22 0.30 0.24 0.02 0.44 69.91 20.68 7.43 1.98
5 0.26 0.30 0.28 0.06 0.48 65.45 22.26 9.56 2.73
6 0.29 0.29 0.32 0.10 0.51 60.93 24.04 11.31 3.72
7 0.30 0.29 0.32 0.11 0.51 60.22 24.19 11.79 3.81
8 0.32 0.29 0.36 0.14 0.54 55.96 25.59 13.60 4.86
9 0.35 0.29 0.38 0.16 0.57 52.26 26.84 14.84 6.06
10 0.37 0.29 0.40 0.19 0.59 49.61 27.15 16.19 7.05
11 0.39 0.29 0.43 0.21 0.61 46.62 27.55 17.35 8.49
12 0.40 0.28 0.44 0.22 0.62 44.59 27.96 18.44 9.01