TABLE 2.

Biolayer interferometry (Octet) analysis of monoclonal antibody pairing using as binding antigen recombinant leptospiral virulence-modifying protein, LA0591a,b,c,d

Capture mAb in pair Detection mAb in pair
6A5 5E10 5G10 5F8 5A7
6A5 0.04 0.3246 0.2652 0.3658 0.0399
5E10 0.1099 0.0304 0.1584 0.0575 0.1675
5G10 0.0835 0.1359 0.0518 0.1365 0.0912
5F8 0.0783 0.0075 0.1019 0.0283 0.128
5A7 0.0929 0.2232 0.1762 0.2364 −0.0076
a

Binding Response Unit (nm) – in nanometers, measures wavelength shift due to biomolecular binding (reflecting mass changes on the biosensor surface).

b

Paired antibodies are indicated by an underline.

c

The self-pairing or blocking effect, highlighted in gray, is used as a threshold to determine the strong pairs.

d

Mouse-pooled purified IgG was included as a negative control as a detection antibody, and it shows that the sensor is completely saturated.