Analysis of vibration and comfort in infants

Maria Rubega 1, Paola Contessa 2,✉, Maria Elena Cavicchiolo 3, Anna Trivillin 3, Edoardo Passarotto 1, Iacopo Tamellin 4, Giovanna Verlato 3, Ivan Tomasi 5, Alberto Trevisani 6, Eugenio Baraldi 1,7, Stefano Masiero 1,2
PMCID: PMC12603036  PMID: 41214014

Abstract

Infants are routinely subjected to vibration and stress when moved. While some research exists for simulated motion in cars, other transportation means such as prams are rarely studied. Additionally, the effect of vibration on the comfort of infants or young children who are unable to provide feedback has never been addressed. The objective of this study was to measure and evaluate vibrations transmitted to infants lying on a pram during a walk using wearable inertial measurement units. Sensors were placed on the infant’s forehead and thorax, on the pram, on the ankle and wrist of the parent pushing the pram on four types of terrain, and specifically resin floor, asphalt, porphyry, and gravel. The amount of vibrations transmitted to the infants was assessed by comparing the acceleration measured near the pram wheels with that measured on the infants’ thorax. The comfort level of the child was measured using the COMFORTneo scale, i.e., a method used by clinicians to measure neonates’ comfort and distress levels. The cradle and mattress act as a low-pass filter attenuating vibrations measured near the pram wheel as a result of moving on different terrains. On the terrains tested, the median value of acceleration measured at the infants’ thorax did not exceed the ISO guidelines for vibration levels perceived as hazardous to human health by an adult. This research demonstrates the feasibility of measuring vibrations on infants during transport and provides insights on vibration exposure on different types of terrain.

Keywords: Inertial measurement units, Infant comfort, Pram transport, Wearable sensors, Whole-body vibrations

Subject terms: Engineering, Health care

Introduction

Vehicles expose people to mechanical vibrations that can affect human health and comfort1. Vibrations may vary in amplitude and frequency over time depending on the speed and direction of movement. Whole-body vibration can cause discomfort, annoyance and physiological changes2. Vibrations are an important consideration both during transport using a vehicle such as a car, as well as when considering individuals who are transported on a pram pushed by another user. In fact, research on the effect of vibrations during pram transport on children and infants is scarce and pram transport is assumed to be safe or not distressful despite lack of evidence, even in the case of individuals with underlying health issues or in the case of transport on rough or uneven surfaces.

To date, only a handful of studies have attempted to assess whole-body vibration in infants during transport3–6. The majority used manikins for measuring vibrations7. Only one study measured vibrations on newborns during inter-hospital transport. This is a limitation in that manikins may not respond to vibrations in the same manner as an infant or a child.

Possibly due to the lack of research in this area, current standards for evaluating human response to whole-body vibration have been developed only for adults. The main standard is the International Standard ISO 2631-1 (1997)8. It provides methods for evaluating vibration detected while in a supine position, and thresholds for identifying when vibrations are harmful to human health in adult individuals. This directive suggests that values of vibration greater than 2.8 Inline graphic for exposures between 1 and 10 min could be harmful to human health8. In addition to health, ISO 2631-1 sets benchmarks and directives also for the person’s comfort and perception. With regard to comfort, ISO 2631-1 reports no conclusive evidence that comfort degrades with increasing duration of applied vibration. Instead, the amplitude of vibration should be assessed by calculating the frequency-weighted root mean square (rms) acceleration of each axis of translational vibration at the surface support of the person. Acceptable vibration levels for comfort depend on many factors (e.g., type of passenger activity, acoustic noise, temperature). ISO 2631-1 gives approximate indications of likely responses to different levels of total vibration in public transport (see Table 1). When above the identified acceptable ranges, they could lead to vertigo, disequilibrium, nausea, tiredness and even respiratory disorders. In terms of perception, there is a large variability in vibration perception between individuals. The perception threshold decreases slightly with increasing vibration duration up to one second and very little with further increases in duration. Although the perception threshold does not continue to decrease with increasing duration, the sensation produced by vibration magnitudes above the threshold may continue to increase. For vibration frequencies, ISO 2631-1 considers the frequency range [0.5–80] Hz for the effects on the health, comfort and perception of normal human subjects and [0.1–0.5] Hz for motion sickness. These directives however have been derived exclusively based on data from adult individuals. As of today, no standard has been developed for infants whose anthropological characteristics differ from those of adults7. Therefore, even though it may not be directly applicable to infants, ISO 2631-1 remains the only existing standard to assess the response of human body to whole-body vibration.

Table 1.

Expected reactions to various magnitude of overall vibration total values in public transport from ISO 2631-18.

RMS values Level of Comfort
less than 0.315 Inline graphic not uncomfortable
Inline graphic a little uncomfortable
Inline graphic fairly uncomfortable
Inline graphic uncomfortable
Inline graphic very uncomfortable
greater than 2 Inline graphic extremely uncomfortable

For the analysis of vibration, the behavior of the human body is approximated to that of a mechanical system, and typical techniques for the analysis of mechanical vibrations are exploited9,10. The behavior of an n degrees of freedom mechanical system can be described through the set of n eigenvalue-eigenvector pairs which are the solutions of the eigenproblem related to the system linearized dynamics11. Each eigenvalue is related to a natural frequency of the system, while the related eigenvector describes one of the system mode shapes. The natural frequencies and mode shapes depend on the system inertial and elastic properties12. In the case of forced vibrations, i.e., when the system is excited through an external disturbance force, after the transient, the system will evolve accordingly to the spectrum of such force. The vibration amplitude may increase considerably when such spectrum will features harmonics in the proximity of the system natural frequencies. Such aspect is exacerbated in the case of undamped systems. In this case, the resonance frequencies of the system are equal to its natural frequencies and the resonance phenomena provide vibrations which, at least theoretically, will tend to infinite. In practice, vibrations will be large but usually finite since real systems are always at least lightly damped11.

If the external excitation source is such that the internal organs are experiencing a resonance condition, then injuries can happen due to large amplitude vibrations. Vibrations can cause disorders in the central and peripheral nervous system, gastrointestinal tract, locomotor organs as well as in the systemic micro- and macro-metabolism2,13.

Being comfortable is a sense of physical and psychological ease. Infants are not yet developmentally capable of expressing their state of comfort. Pain is one of the causes for discomfort, but not every discomfort can be attributed to pain14. Scales designed to assess pain and discomfort in infants are mainly based on physiological and behavioural changes induced by pain15–17. The assessment of discomfort and pain remains a difficult aspect of infant care because of a lack of a gold standard18. Among the pain scales developed for newborns, the COMFORTneo scale offers a validated method for clinicians to measure neonates’ comfort and distress levels19.

Since irrespective of the mode of transportation, it is unavoidable to transmit mechanical vibration from the vehicle body to the infant20, the objective of this study is to investigate the characteristics of vibrations transmitted to 18 infants (age between 0 and 6 months) during a walk with a pram, using wearable inertial measurement units (IMUs). Four distinct terrain types were selected for the experimental trials, including resin floor, asphalt, porphyry, and gravel. The level of comfort or discomfort experienced by the infant was measured by an expert clinician using the COMFORTneo scale. IMUs were applied not only on the infants’ bodies, but also on the pram and on the parents’ wrists and ankles. The comparison of the recorded signals at different locations allowed us to formulate a hypothesis about the amplitudes and frequencies detected on the infants’ bodies. Moreover, the walking pattern and cadence of the parents’ driving the pram was monitored in order to assess the influence of the parents’ driving force and acceleration on the vibrations measured on the infants.

The results of this work allowed us to measure and evaluate vibrations transmitted to infants lying on a pram during a walk over different types of terrains using wearable inertial measurement units.

Methods

Participants

Eighteen healthy subjects (age between 0 and 6 months), together with a parent, were enrolled in this study. The subjects involved in the study were two neonates and sixteen infants21. Hereafter we will refer to all the subjects as infants for brevity. The weight and age of each subject is shown in Fig. 1. Participants were born at term, with regular perinatal status, with no ongoing pathology at the time of assessment. Preterm infants and infants with acute or chronic diseases were excluded from the study. Both parents signed informed consent to participate in the study.

Figure 1.

Figure 1

Age and weight of the infants included in the study.

Experimental protocol

Each recruited infant underwent a standard pediatric examination, checking vital signs. Axial and appendicular tone, as well as posture, were assessed using the Hammersmith Neonatal Neurological Examination and the Hammersmith Infant Neurological Examination for infants22,23. These examinations were used to obtain a standardized and accurate measurement of motor skills and muscle tone in order to confirm absence of underlying conditions.

During the initial assessment, a pediatrician also assigned a score using the COMFORTneo scale19 evaluating the following parameters: alertness; calmness/agitation; crying; body movement; facial tension and body muscle tone (for further details see Appendix II). The total score ranges from 5 to 30, with the lower score (5) indicating a state of comfort and scores (> 15) indicating increasing discomfort.

Wearable IMUs composed by accelerometers and gyroscopes with sampling frequency Inline graphic=284 Hz (transmission/reception frequency: 2402–2484 MHz, operating temperature range: (0–50) Inline graphicC , acceleration measurement range: ± 16 g, dimension: 32Inline graphic17Inline graphic12 mm, weight: 10–14 g) (WaveTrack IMUs, manufactured by Cometa srl, Milano - Italy), were attached to the infant’s forehead and thorax, to the ankle and wrist of the parent pushing the pram, to the pram cradle (under the mattress), to the footboard between the pram wheels (Fig. 2). Sensors were attached to the skin of the child and to the pram by using medical-grade double sided tape, and they were positioned as shown in Fig. 2 to ensure that one of the three axes would align approximately with the direction of movement and that this direction would be approximately parallel to the ground.

Figure 2.

Figure 2

Position of the wearable sensors.

Data were collected during a walk of approximately 15 min of duration, with at least 30 s over a resin floor (inside the laboratory building), asphalt, porphyry and gravel, while the parent pushed the pram in a forward direction (straight line). No ascending or descending paths were considered. During the walk over each different type of floor surface, the pediatrician repeated the evaluation of the COMFORTneo scale to assess alertness, calmness/agitation, crying, body movement, facial tension and body muscle tone of the child.

This study (ID 22835, URC Code AOP3233) was conducted at the University Hospital of Padova between June and December 2024. Ethical approval was obtained from the Territorial Ethics Committee (5934/AO/24) on May 9, 2024. All experiments were performed in accordance with relevant guidelines and regulations.

Data processing

Time domain analysis

The rms value of the acceleration amplitude (a) was calculated for each direction (i) and terrain for intervals of 30 s. The translational motion considered in this work occurs along the direction of movement (Inline graphic x-axis), parallel to the ground and perpendicular to the direction of movement (Inline graphic y-axis), and parallel to the force of gravity (Inline graphic z-axis).

graphic file with name d33e585.gif 1

where N corresponds to the number of samples of the time-series. The vibration total value (Inline graphic) was then computed as follows:

graphic file with name d33e601.gif 2

To compute Inline graphic, the raw acceleration time-series for each direction (i) where high-pass filtered with a cut-off frequency of 0.5 Hz with a zero-phase digital Butterworth filter of order 6. This minimized the component of the acceleration related to voluntary movement of the infants’ head.

Time-frequency domain analysis

To avoid frequency distortion, data were not high pass filtered for the time-frequency analysis. Instead, raw data were detrended to remove time-varying drifts and the gravity components, i.e., the least squares best fit line was subtracted from each time series. Therefore, data from the infants’ forehead were not included in the frequency analysis due to the presence of low frequency content related to voluntary spontaneous movements rather then to the applied vibrations.

The spectrogram was computed using the short-time Fourier transform (STFT) for each direction and terrain with a frequency resolution of 1 Hz and a temporal resolution of 2.6 s in the interval [0.1, 100] Hz (that includes the interval [0.1 80] Hz considered in ISO 2631-1). The STFT was computed by sliding a Kaiser window g(t) over the signal and computing the Discrete Fourier Transform (DFT) of each segment of the windowed data. The Inline graphic column of the STFT matrix Inline graphic (Inline graphic number of windows; f frequency) contains the DFT of the windowed data centered about time mR:

graphic file with name d33e655.gif 3

Then, the magnitude-squared coherence which is a function of frequency with values between 0 and 1 was computed. This estimate indicates how the acceleration recorded at the infant’s thorax (y) corresponds to the acceleration recorded from the sensors (x) on the pram cradle, pram footboard and parent’s wrist at each frequency. The magnitude-squared coherence (Inline graphic) is a function of the power spectral densities, X(f) and Y(f), and the cross power spectral density of x and y, XY(f):

graphic file with name d33e700.gif 4

The power spectral density and cross power spectral density were computed using Welch’s overlapped averaged periodogram method (with 20% overlapping windows of 2.6 s) in signals of 30 s. To test whether magnitude-squared coherence was significant, a 95% confidence limit (CL) was used24. The confidence limit was approximated by the following equation:

graphic file with name d33e711.gif 5

where n is the number of windows.

The magnitude-squared coherence allows to identify significant frequency-domain correlation between two time-series. Only estimates of the cross power spectral density where significant frequency-domain correlation exists should be considered.

In the frequency range in which the Inline graphic was significant, we computed the cross-power spectral density (XY(f)) and the amplitude of the experimental frequency response function (FRF) between the cross power XY(f) of the input x and output y divided by the auto power XX(f) of the input x as shown below:

graphic file with name d33e759.gif 6

This measure provides an indication of which frequencies are amplified at the infant’s thorax (considered as output y) compared to the signals recorded in the other positions (i.e., pram cradle, pram footboard and parent’s wrist, considered as inputs x).

To not lose the information about direction and to compute cross power spectral density avoiding any signal distortion, we decided not to compute the power spectral density of the resultant acceleration, but of the three components along the x- y- and z- axes separately.

Additionally, the parent’s cadence was inferred from the DFT (Equation 3) of the gyroscope signal recorded on the parents’ ankle. The primary peak of the spectrum was employed to estimate its value in [steps/min].

Statistical analysis

Normality of continuous variables was tested through Shapiro-Wilk tests. Because the RMS values were not normally distributed and the sample size was limited, nonparametric statistical tests were used in this study. The scores of the COMFORTneo scale, the vibration total values (Inline graphic) and the parents’ cadence, for each terrain were compared using the Kruskal-Wallis test, which is a nonparametric version of the classic one-way ANOVA and an extension of the Wilcoxon rank sum test to more than two groups. It compares the medians of the groups (i.e., four terrains) of data to determine whether the samples are from the same population (or, equivalently, from different populations with the same distribution, i.e., null hypothesis). Subsequent multiple comparison tests were then applied to pairs of sample medians. Pairwise comparisons were conducted through Wilcoxon rank sum tests. Group differences with p < .05 were considered statistically significant.

Results

Time domain analysis

First, we compared the cadence of the parents to check whether all parents maintained a comparable cadence in all four terrains. These values are represented in Fig. 3a as boxplots (i.e., box limits indicate the range of the central 50th percentile of the data, with a central line marking the median value. Lines extend from each box to capture the range of the remaining data, with crosses placed past the line edges to indicate outliers, if present). The median values for the resin floor, asphalt, porphyry and gravel were, respectively, 53.4, 55.5, 52.5, and 52.2 steps/min. The only significant difference (null hypothesis: the data in each column comes from the same distribution) was found between the cadence on the asphalt and the cadence on the gravel (Inline graphic).

Figure 3.

Figure 3

(a) Cadence in steps/min of the parents pushing the pram on the four different terrains. (b) Total score of the COMFORTneo scale on the four different terrains.

We then compared the scores of the COMFORTneo scale assigned by the pediatrician in the four different conditions (inside the laboratory, i.e., during the pediatric visit, and outside, i.e., over the asphalt, porphyry and gravel). No significant differences were detected. The median values were below 15. The maximum values were recorded on the gravel (Fig. 3b).

Figure  4 shows the vibration total value (Inline graphic) computed for consecutive 1-s non-overlapping segments in a representative subject, isolating 30 s whilst the pram is pushed inside the laboratory over a very smooth and regular surface (resin floor (a-b)) and outdoor (i.e., over the asphalt (c-d), the porphyry (e-f) and the gravel (g-h)). Qualitatively, we observe in the outdoor terrains the highest recorded values at the level of the pram footboard or at the parent’s wrist, followed by the cradle level (Fig. 4b,d,f,h). Values over the infant’s thorax appeared to be almost equivalent to the ones of the cradle.

Figure 4.

Figure 4

Vibration total value (Inline graphic) computed for consecutive 1-s non-overlapping segments for one subject for different terrains recorded at: forehead (green) and thorax (blue) of the infant, cradle (under the mattress, orange) and footboard between the two wheels (violet) of the pram, wrist of the parent (yellow). (a-b) Values on resin floor. (c-d) Values on asphalt. (e-f) Values on porphyry. (g-h) Values on gravel.

Then, to provide a statistically meaningful analysis the vibration total values (Inline graphic) were calculated for segments of 30 s in each terrain for all participants. These values are represented in Fig. 5 as boxplots. The presence of uneven terrain leads to an increase in the detected value (i.e., the lowest values were observed on the resin floor (median value of 1.12, 0.94, 0.46, 0.90, and 1.47 for the infant’s head, infant’s thorax, cradle, footboard, and parents’ wrist, respectively), the highest values on the gravel (median value of 3.40, 2.60, 3.29, 9.44, and 6.40 for the infant’s head, infant’s thorax, cradle, footboard, and parents’ wrist, respectively), the values for the asphalt (median value of 2.41, 1.83,1.68, 4.53, and 3.96 for the infant’s head, infant’s thorax, cradle, footboard, and parents’ wrist, respectively) and porphyry (median value of 2.35, 1.94, 1.73, 3.76, and 4.03 for the infant’s head, infant’s thorax, cradle, footboard, and parents’ wrist, respectively) were comparable). Indeed, all conditions are characterized by different distributions (Fig. 5) except when comparing the values between the asphalt and porphyry conditions (p-value of 0.99, 0.98, 0.98, 0.90, and 0.57 for the forehead, thorax, wrist, cradle, and footboard positions, respectively). Asphalt and porphyry seemed to have a similar effect.

Figure 5.

Figure 5

Vibration total value (Inline graphic) computed at the infants’ (a) forehead (green) and (b) thorax (blue), (c) cradle (orange), (d) footboard (violet) and (e) parents’ wrist (yellow) for all participants.

Time-frequency domain analysis

Spectrograms, analogous to those of the representative subject (Fig. 6), were obtained for each subject (for the sake of simplicity, only spectrograms related to the z-axis are shown in Fig. 6, spectrograms related to x- and y- axes are reported in Appendix I). Qualitatively, we can see that the power does not change abruptly over time in the same terrain. Different frequency components seem to characterize different terrains. Observing the spectrograms at the cradle and the footboard (Fig. 6, second and third row), higher frequency (Inline graphic) components seem to be present that are absent at the infant’s thorax. As the terrain becomes more uneven, the presence of higher frequency components increases as expected. Values at the infants’ thorax are always at frequencies lower than Inline graphic 50 Hz.

Figure 6.

Figure 6

Time-frequency power spectrum of accelerations along the z-axis recorded for different terrains for one subject at: the thorax of the infant (first row), at the cradle (under the mattress - second row), footboard between the two wheels of the pram (third row) and at the parent’s wrist (fourth row). Amplitudes are color coded (cold colors represent lowest values and hot colors represent highest values). A red horizontal straight line highlights the 80 Hz threshold.

The magnitude-squared coherence, averaged over all participants, between the signal recorded at the infants’ thorax and the signals recorded at the cradle, footboard and parents’ wrist was then computed and compared to the confidence limit, i.e., CL = 0.21 ((Fig. 7a–d). The magnitude-squared coherence estimate has values between 0 and 1, which indicate how well the two signals correlate at each frequency, with values closer to 1 indicating higher correlation and values closer to 0 indicating lower correlation. Inline graphic showed that the signal recorded at the infants’ thorax was correlated with that recorded at the cradle, footboard and parents’ wrist along z-axis for specific frequency ranges. Above 8 Hz, the Inline graphic between the infants’ thorax and the cradle tends to decrease with increasing frequency (orange signals in (Fig. 7 a–d). On average, above Inline graphic 50 Hz, this correlation was not significant (i.e., lower than the confidence limit). A lower correlation, but still greater than CL, was present between the infants’ thorax and the footboard and between the infants’ thorax and the parents’ wrist along z-axis (respectively, violet and yellow in Fig. 7 a–d). Above Inline graphic 20 Hz, this correlation was not significant.

Figure 7.

Figure 7

Magnitude-squared coherence, cross spectral density and frequency response function amplitude averaged among all participants for each terrain along z-axis. (a-d) The first row represents the magnitude-squared coherence between the signal recorded at the infant’s thorax versus, respectively, the signal recorded at the cradle (orange), at the footboard (violet) and at the parent’s wrist (yellow) along z-axis (confidence limit (CL) is represented by a black straight line). (e-h) The second row represents the cross-spectral density along the z-axis. (i-l) The third row represents the FRF amplitude along the z-axis.

The cross power spectral density, which measures the distribution of power of a pair of signals as a function of frequency, reported two main peaks at Inline graphic 2 Hz and 8 Hz between the signals at the infants’ thorax and parents’ wrist (yellow in Fig. 7 (e-h)). The cross power spectral density between the signals at the infants’ thorax and cradle (orange) and between the infants’ thorax and footboard (violet) reported common frequency components in the interval Inline graphic [2, 15] Hz (Fig. 7 (e-h)).

The FRF, which indicates amplification of vibrations for values > 1, highlighted that the frequency components characterizing the infants’ thorax response (considering as inputs, respectively, the cradle, footboard and parents’ wrist signals) were in the interval Inline graphic [4 - 14] Hz (Fig. 7 (i-l)).

Discussion

The motivation of this work stemmed from the lack of standards for whole-body vibration exposure during infant transport. The results show that:

  1. The vibrations measured on infants are detectable by wearable inertial measurement units.

  2. The cadence of the parents pushing the pram is detectable by the gyroscope on the ankle.

  3. The COMFORTneo scale did not report statistically significant differences in the level of comfort of the infants during the walk.

  4. The vibration total value measured on the infants, on average, was less than 2.8 Inline graphic except for the forehead on the gravel.

  5. In our experiment, the frequency range [0.1 80] Hz proposed by ISO 2631-1 seems suitable to estimate the vibration accelerations measured on the infants.

  6. The common frequency components between the vibration accelerations measured on the infants and on the pram were in the interval Inline graphic [4, 15] Hz.

The parents’ cadence was faster on the asphalt. Parents tended to be slower on the resin floor, probably because they were in a corridor in an enclosed environment and were more careful to avoid possible people or obstacles, and on the porphyry and gravel, probably because they perceived more vibration and tended to reduce their speed. Despite that the cadence median values are comparable among the four terrains. Interestingly, the first main peak in the cross spectral density between the infants’ thorax and parents’ wrist corresponds to the second harmonic of the cadence (Inline graphic 2 Hz).

COMFORTneo scale scores did not emphasize significant differences in the comfort of the infants during the walk, but the maximum scores were recorded on the gravel. It is important to emphasize that the COMFORTneo scale score is not limited to measuring the level of discomfort due to vibrations and that the state of the infant evaluated by this scale can be conditioned by numerous factors. Nonetheless, this scale was chosen because it assesses comfort, rather than only pain, and it has been validated in newborns and infants25,26.

The median recorded values of the vibration total value Inline graphic for the infant did not exceed the threshold of 2.8 Inline graphic except for the values recorded at the infants’ forehead over the gravel. Values of vibration total values should however be interpreted with caution because, despite filtering, their values were likely to be still influenced by infants’ spontaneous movements. Moreover, the rms values along the x-axis includes the acceleration caused by the parent pushing the pram, which possesses neither a constant velocity nor a null acceleration. This encompasses not only the effect of the different terrains, but also other factors.

The frequency weighting proposed in ISO 2631-1 was not applied because our measurements included sensors directly on the person and not on the contact surface between the person and the means of transport.

The frequency range [0.1, 80] Hz – proposed by ISO 2631-1 – seems sufficient to record vibrations on the infant’s body in our experiment. From the time-frequency analysis, at the cradle and the footboard, higher frequency (Inline graphic) components were present that were absent at the infant’s thorax. The infant’s thorax presented values not exceeding Inline graphic 50 Hz. The analysis of cross spectral density and frequency response function revealed common frequency components between the infants and the pram in the interval Inline graphic [4 15] Hz. In the literature, there was an attempt to estimate the natural frequencies of the child’s body reporting two frequency intervals of [8-11] Hz and [6-17] Hz for the thorax. This method estimated the natural frequencies of parts of the child’s skeletal system from data collected from adults in a seated position27.

There are few results in the literature analyzing the vibration accelerations in prams. Results from different studies are difficult to compare because of differences in equipment design, types of transport vehicles, and measurement tools7. A pilot study on vibrations estimated on a 3.8 kg brick inside a pram when moving on different surfaces at 4 km/h found vibration rms values (along our z-axis) ranging from 0.45 to 4.74 Inline graphic and mainly in the frequency interval from 0 to 30 Hz3. Although a brick was used as a dummy in the above study, the cadence of the adult pushing the pram, rms values and frequency ranges are in agreement with our results.

Another study on a simulated environment with an empty incubator pushed over a selected route inside the hospital, found vibrations in the z-axis above the ISO 2631-1 extremely uncomfortable level (2 Inline graphic). Average rms values for the acceleration were found to be at a maximum of 2.6 Inline graphic, and the peak acceleration values were found to be at a maximum of 15.9 Inline graphic4. To potentially attenuate vibration levels in incubator transport, several engineering modifications focused on the type of mattress28–30. In our experimental protocol, the cradle (and the mattress) seems to have a Inline graphic 15 Hz low-pass filter effect as evidenced by the lower frequency range of vibrations recorded at the different locations of the pram and on the infants.

To the best of our knowledge, our study is the first to measure vibrations directly on the infant’s body and simultaneously at different levels of the pram and on the parent pushing the pram. The inclusion of infants and parents in our experimental protocols had the benefit of mimicking a real life condition, but it also led to a number of limitations. First, the infant was not always completely still and the position of the sensor was not perfectly parallel to the floor. Second, we could collect data for a relatively short amount of time (total walk of  15 min duration) because the infants could only be cooperative for a limited amount of time. This approach however also ensured that parents did not fatigue during the walk and did not vary their walking pace considerably. Third, parents did show a tendency to reduce their walking speed as the terrain becomes more uneven or unfamiliar.

A second difficulty in discussing and interpreting our results is the lack of standards and guidelines for vibration exposure during infant transport. The only standards available are for adults.

It should also be noted that our measurements could be in part dependent on the mechanical characteristics of the pram used.

This research provides unique measures of vibration exposure to the infant body during a walk in a pram in an ecological environment. The results are consistent with values reported in the literature on similar experimental protocols. Specifically, the cradle/mattress seems to act as a low-pass filter. The median values estimated at the thorax of the infant seemed to not exceed the ISO guidelines for vibration levels that would be perceived as hazardous to human health by an adult (2.8 Inline graphic).

These preliminary findings contribute to a more comprehensive understanding of vibration exposure and transmission to infants. The data and methodological approaches presented can hopefully also encourage further studies in the field for developing standards and whole-body vibration exposure limits that apply throughout the lifespan, and that could inform the design of prams, transport incubators, and mattresses, among others.

Supplementary Information

Author contributions

M.R., G.V., I.T., A.T., E.B, and M.S. conceived the experiment(s) and designed the work, M.R., P.C., M.E.C., and A.T. conducted the experiment(s), M.R. analysed the results, M.R., P.C., I.T., and A.T. interpreted the data. M.R. and P.C. drafted the manuscript. All authors reviewed the manuscript.

Funding

This work was supported in part by “Ministero delle Imprese e del Made in Italy” (D.M. MISE 31/12/2021 - Accordi per l’innovazione - Id: 10210 - MISE 127 - DESIGN FOR BABY WELLNESS). Maria Rubega and Edoardo Passarotto are supported by the European Union - Next Generation EU, Mission 4 Component 1 (CUP C53D23006170006).

Data Availability

The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.

Declarations

Competing interests

The authors declare no competing interests.

Footnotes

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

The online version contains supplementary material available at 10.1038/s41598-025-21080-9.

References

  • 1.Paddan, G. & Griffin, M. Evaluation of whole-body vibration in vehicles. J. Sound Vib.253, 195–213 (2002). [Google Scholar]
  • 2.Griffin, M. J. Handbook of human vibration (Academic press, 2012). [Google Scholar]
  • 3.Sierzputowski, G. et al. Pilot studies of vibrations induced in perambulators when moving on different surfaces. Appl. Sci.11, 7746 (2021). [Google Scholar]
  • 4.Browning, J., Walding, D., Klasen, J. & David, Y. Vibration issues of neonatal incubators during in-hospital transport. J. Clin. Eng.33, 74–77 (2008). [Google Scholar]
  • 5.Blaxter, L. et al. Neonatal head and torso vibration exposure during inter-hospital transfer. Proceedings of the Institution of Mechanical Engineers. Part H Journal of Engineering in Medicine 231: 99–113 (2017). [DOI] [PMC free article] [PubMed]
  • 6.Solvik-Olsen, T., Kåsin, J. I., Hagemo, J. & Heyerdahl, F. Manikin study showed that neonates are exposed to high sound and vibration levels during helicopter incubator transports. Acta Paediatr.113, 2384–2390 (2024). [DOI] [PubMed] [Google Scholar]
  • 7.Goswami, I. et al. Whole-body vibration in neonatal transport: A review of current knowledge and future research challenges. Early Human Dev.146, 105051 (2020). [DOI] [PubMed] [Google Scholar]
  • 8.Mechanical Vibration And Shock – Evaluation of human exposure to whole-body vibration. Part 1 (BS ISO 2631, 1997).
  • 9.Kitazaki, S. & Griffin, M. J. A modal analysis of whole-body vertical vibration, using a finite element model of the human body. J. Sound Vib.200, 83–103 (1997). [Google Scholar]
  • 10.Rützel, S., Hinz, B. & Wölfel, H. P. Modal description-a better way of characterizing human vibration behavior. J. Sound Vib.298, 810–823 (2006). [Google Scholar]
  • 11.Ewins, D. Modal Testing: Theory, Practice and Application (Research Studies Press LTD., 2000), 2nd edition edn.
  • 12.Richiedei, D., Tamellin, I. & Trevisani, A. Simultaneous assignment of resonances and antiresonances in vibrating systems through inverse dynamic structural modification. J. Sound Vib.485, 115552 (2020). [Google Scholar]
  • 13.Dupuis, H. & Zerlett, G. The effects of whole-body vibration (Springer, Berlin, 2012). [Google Scholar]
  • 14.Ashkenazy, S. & Ganz, F. D. The differentiation between pain and discomfort: a concept analysis of discomfort. Pain Manag. Nurs.20, 556–562 (2019). [DOI] [PubMed] [Google Scholar]
  • 15.Luna-Hernández, G., Varela-Cardoso, M. & Palacios-Blanco, J. C. Utility of a physiologic stability index based on transport risk index of physiologic stability (trips) for the evaluation of infants transferred to a specialized hospital. Bol. Med. Hosp. Infant. Mex.72, 45–54 (2015). [DOI] [PubMed] [Google Scholar]
  • 16.Lee, S. K. et al. Transport risk index of physiologic stability: a practical system for assessing infant transport care. J. Pediatr.139, 220–226 (2001). [DOI] [PubMed] [Google Scholar]
  • 17.van Dijk, M. et al. Taking up the challenge of measuring prolonged pain in (premature) neonates: the comfortneo scale seems promising. Clin. J. Pain25, 607–616 (2009). [DOI] [PubMed] [Google Scholar]
  • 18.Ranger, M., Johnston, C. C. & Anand, K. Current controversies regarding pain assessment in neonates. In Seminars in perinatology, vol. 31, 283–288 (Elsevier, 2007). [DOI] [PubMed]
  • 19.Meesters, N. J. et al. Comfortneo scale: a reliable and valid instrument to measure prolonged pain in neonates?. J. Perinatol.43, 595–600 (2023). [DOI] [PubMed] [Google Scholar]
  • 20.Wasserman, D. E. Vibration: principles, measurements, and health standards. In Seminars in Perinatology14, 311–321 (1990). [PubMed] [Google Scholar]
  • 21.Williams, K. et al. Standard 6: age groups for pediatric trials. Pediatrics129, S153–S160 (2012). [DOI] [PubMed] [Google Scholar]
  • 22.Mercuri, E., Ricci, D., Pane, M. & Baranello, G. The neurological examination of the newborn baby. Early Human Dev.81, 947–956 (2005). [DOI] [PubMed] [Google Scholar]
  • 23.Skorup, J. C. et al. Hammersmith neonatal and infant neurological examinations scores in typically developing infants aged 1–6 months. J. Child Neurol.40, 10–14 (2025). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Mima, T. & Hallett, M. Electroencephalographic analysis of cortico-muscular coherence: reference effect, volume conduction and generator mechanism. Clin. Neurophysiol.110, 1892–1899 (1999). [DOI] [PubMed] [Google Scholar]
  • 25.Krechel, S. & Bildner, J. Cries: a new neonatal postoperative pain measurement score initial testing of validity and reliability. Paediatr. Anaesthesia5, 53–61 (1995). [DOI] [PubMed] [Google Scholar]
  • 26.Crellin, D. J., Harrison, D., Santamaria, N., Huque, H. & Babl, F. E. The psychometric properties of the flacc scale used to assess procedural pain. J. Pain19, 862–872 (2018). [DOI] [PubMed] [Google Scholar]
  • 27.Więckowski, D. An attempt to estimate natural frequencies of parts of the child’s body. Archiwum Motoryzacji 61–74 (2012).
  • 28.Prehn, J. et al. Decreasing sound and vibration during ground transport of infants with very low birth weight. J. Perinatol.35, 110–114 (2015). [DOI] [PubMed] [Google Scholar]
  • 29.Sallee, W., Bentley, A., Walding, D. & Christofi, C. Neonatal transport incubator: vibration identification, ranking, and attenuation—a novel approach to patient tray stabilization. J. Clin. Eng.41, 101–105 (2016). [Google Scholar]
  • 30.Gajendragadkar, G. et al. Mechanical vibration in neonatal transport: a randomized study of different mattresses. J. Perinatol.20, 307–310 (2000). [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Data Availability Statement

The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.