Skip to main content
. 2025 Nov 14;20:1002. doi: 10.1186/s13018-025-06389-5

Table 2.

First loading condition applied to the intact and implanted femur during optimisation

Force (N) Point coordinates (mm)
X Y Z X Y Z
graphic file with name 13018_2025_6389_Figa_HTML.gif Hip Load − 535.7 − 342.5 − 1747.2 P0 0 0 0
F1 426.3 31.6 635.8 P1 − 61.2 − 7.3 − 11.0
F2 − 3.7 − 5.1 − 139.7
F3 52.9 85.3 97
F6 − 6.6 136.0 − 682.8 P2 − 53.9 − 7.4 − 56.7

Peak hip load acting on the femoral head during stair climbing walking and corresponding simplified muscle forces (F1-F6) acting on the femur at the same time point in the gait cycle of peak loading during walking. [18, 23, 24].