Comparison of two digital PCR platforms for quantification of genetically modified soybean events

Daniela Verginelli a, Sara Ciuffa a,, Katia Spinella a, Davide La Rocca a, Daniela Villa b, Alessandra Barbante b, Elena Perri b, Ugo Marchesi a
PMCID: PMC12622311  PMID: 41220334

ABSTRACT

In the European Union, the food and feed containing more than 0.9% of approved genetically modified organisms (GMOs) per ingredient must be labeled before placed on the market. In this legislative context, the official control laboratories have to perform validated PCR assays, according to the principles and requirements of ISO/IEC 17025 standard, regarding event-specific methods for the detection, identification and quantification of GMOs. In recent years, with the advent of digital PCR (dPCR) techniques, a growing number of laboratories have transferred the previously validated real-time PCR testings into a dPCR format. Compared to real-time PCR, the dPCR offers the advantage to provide accurate quantification without the need for external calibration samples, show less sensitivity to PCR inhibitors and is more suitable for multiplexing. In this study, an in-house validation of quantitative duplex dPCR methods was performed involving MON-04032–6 and MON89788 assays with the lectin reference gene, on the two different platforms Bio-Rad QX200 and Qiagen QIAcuity. All evaluated data and the validation parameters agree with the acceptance criteria validation performance parameters according to the JRC Guidance documents and technical reports in both platforms. The duplex PCR methods here investigated are equivalent in terms of performance to the singleplex real-time PCR method and suitable to perform a collaborative trial for a full validation.

KEYWORDS: Digital PCR, GMO detection, soybean, validation

Introduction

Since the first introduction of GM crops in 1996, their production has shown a continuous and steady increase; as of 2023, the global area of GM crops had reach 206.3 million hectares, with 27 collectively cultivating 11 different GM crops. Among the GM crops, soybeans are the most widely planted at 100.9 million hectares1. In Europe, the presence of genetically modified organisms (GMOs) in food and feed products is regulated, imposing a threshold for labelling of products containing more than 0.9% of authorized GMOs per ingredient (Reg. CE 1829/2003 and Reg. CE 1830/2003)2,3. According to the Reg. CE 1829/2003,2 the developer of a GMO must provide a method for quantifying specific GM events and fund a collaborative trial to validate the method. Currently, all GMO analytical methods submitted for validation to the European Union Reference Laboratory for Genetically Modified Food and Feed (EURL-GMFF) (https://gmo-crl.jrc.ec.europa.eu/) have been developed and optimized for real-time PCR (qPCR). Validated qPCR methods are widely used in European control laboratories, and they must act according to the requirements of the ISO/IEC 17025 standard4.

However, qPCR is prone to the presence of inhibitors in DNA templates, and standard curves based on simplex qPCR analyses are no longer sufficiently cost-effective as the number of GMOs increased over time5,6. Digital PCR (dPCR) is a sensitive nucleic acid quantification PCR technology that works by portioning DNA into tens of thousands of separate reactions called partitions, and then measuring the endpoint fluorescence of each partition to determine the presence (1) or absence (0) of the target7,8. This makes dPCR less reliant on the kinetics of the PCR and eliminates the need for standard curves, similar to qPCR. Statistical methods (Poisson distribution) have been used to calculate the absolute concentration of the target based on the number of positive and negative partitions8. Different sample-partitioning models are available based on several approaches, including microfluidic chips, oil-water emulsions, spinning microfluidic discs, microarrays, and microfluidic nanoplates.9–11

Using droplet digital PCR (ddPCR) (e.g., Bio-Rad QX200 ddPCR system),12 droplets were obtained in a water – oil emulsion to form partitions that separated the template DNA molecules. All reagents were dispersed in nanoliter-sized droplets, and each droplet represented a PCR. After the end-point PCR, each droplet was individually analyzed using an optical detection system. In nanoplate dPCR (e.g., Qiagen QIAcuity One system),13 partitioning was achieved using a dedicated plate. The dPCR system integrates partitioning, thermocycling, and imaging into a single dPCR instrument14. Digital PCR data analysis was performed using software that calculates the results in copies of the target sequence per microliter of reaction. Overall, this method is currently employed in various analytical fields where the quantification of nucleic acid targets is required and is widely adopted in GMO detection and quantification.15–18 Several scientific papers,19–24 guidelines,8, 25–27 and international standards26 provide the requirements for the evaluation of the performance of quantification methods by qPCR and dPCR, and verification by digital PCR has been published.

Previous studies have shown the feasibility of the direct transfer of qPCR validated methods by the EURL-GMFF (European Reference Laboratory for GM Food & Feed, http://gmocrl.jrc.ec.europa.eu/gmomethods/.) for analysis of GMOs, to a dPCR system.21,22

This study aimed to compare two different dPCR platforms to carry out an in-house validation to detect two of the most abundant GM soybean lines on the world market, the transgenic event known commercially as the “Roundup Ready” and MON89788 GM soybean (Unique identifier MON-Ø4Ø32–6 and MON-89788–1). However, for the MON89788 ddPCR duplex assay, in-house validation on the Bio-Rad platform has already been published.21 These qPCR methods have been validated by the EURL-GMFF.28,29 and are routinely used for official control by national reference laboratories (NRLs). To perform a direct comparison between Bio-Rad’s QX200™ Droplet Digital™ PCR System and Qiagen’s QIAcuity digital PCR system for each method, an identical primer-probe set was used. Optimization of the reaction conditions and method verification were performed according to published guidelines.8, 25–27, 30 dPCR performance was assessed in the context of specificity, cross-talk, robustness, dynamic range, linearity, asymmetric limit of quantification (LOQasym), and accuracy (trueness and precision). Moreover, the measurement uncertainty (MU) was evaluated as reported in the ENGL’s document.31,32

Material and Methods

DNA Extraction and Assessment of DNA Purity

The MON-04032–6 SOYA BEAN ERM-BF410bp (> 985 g/kg), ERM-BF410cp (1 g/kg), ERM-BF410dp (10 g/kg), ERM-BF410ep (100 g/kg), and non-modified soybean ERM-BF410ap (< 0.09 g/kg) CRMs were purchased from the Joint Research Centre (JRC) of the European Commission (Geel, Belgium), while MON89788 soybean (AOCS 0906-B2 ≥996 g/kg) and non-modified soybean (AOCS 0906-A <0.8 g/kg) were purchased from the American Oil Chemists’ Society (AOCS, Urbana, IL, USA). DNA was extracted from 200 mg of CRMs using the RSC PureFood GMO kit with the extractor Maxwell®RSC Instrument (Promega Madison, WI, USA), according to the manufacturer’s instructions for the Bio-Rad platform and using a DNA extraction method with 2% CTAB buffer as described in ISO21571:2005 for the Qiagen platform. DNA concentration was measured by dPCR to evaluate the copy number of the endogenous reference gene lectin (lec) using an inhibition test. The inhibition test was carried out at three serial dilution levels, with each level measured in duplicate.33 The average of the absolute copies per reaction measured in the diluted samples multiplied by the dilution factor did not differ more than 25% from the average of the absolute copies per reaction measured at the highest concentration (lowest dilution)33. Dilutions of extracted stock DNA solutions were prepared in nuclease-free water (Sigma-Aldrich Chemie GmbH, Munich, Germany). All DNA extracts were stored at +4°C until subsequent use.

Sample Preparation

The validation study involves testing several GM levels (% m/m) for MON-04032–6 and MON89788, those not available on the market as certified reference materials were produced by mixing the positive material (GM) with non-GM material.

The materials with 2%, 0.5%, and 0.05% levels (m/m) of GM MON-04032–6 were produced by dilution, respectively, of the 10%, 1% and 0.1% GM (m/m) with pure non-GM material. Similarly, the GM levels (10%, 2%, 1%, 0.5% and 0.1% GM (m/m)) of MON89788 were determined as described by Hougs et al., 2017 (annex 3).33 Mixtures were prepared by considering the absolute copy number of the lec reference gene measured by dPCR.

Workflow and Data Analysis of dPCR Analysis

The in-house validation of GM soybean MON89788 and MON-04032–6 was performed on two different digital PCR platforms: QIAcuity dPCR (QIAGEN) and QX200 Bio-Rad. The MON89788 ddPCR assay was previously validated by Verginelli et al.,21 and then the optimized assay was then transferred to the QIAcuity platform (Figure 1).

Figure 1.

Figure 1.

Schematic workflow representing the experimental design of the study.

QIAcuity dPCR (QIAGEN) was performed on a microfluidic QIAcuity Nanoplate (QIAGEN) using a fully integrated system with partitioning, thermocycling, and imaging performed on a single instrument. For qPCR, reaction mixtures were prepared and loaded onto Nanoplate 26k which provides 24 reactions with 26,000 partitions per well. After sealing, the nanoplate was loaded onto the QIAcuity One, which features a five-channel optical format. Thermocycling was performed, the partitions for each well were imaged, and data analysis was performed using the QIAcuity Software Suite (QIAGEN). On the contrary, using the QX200™ ddPCR Systems (Bio-Rad Laboratories), partitions were generated via water–oil emulsion with a droplet generation cartridge and the droplets were then transferred onto a traditional 96-well plate format. This workflow requires the preparation of each reaction well, similar to qPCR, followed by transfer of each reaction into a droplet generation cartridge. Droplets were generated using a QX200 Droplet Generator (Bio-Rad Laboratories, Inc, Berkeley, CA, USA). After the thermocycling phase, the plate was transferred to a QX200 Droplet Reader, and the droplets for each reaction well were read. A quality assessment of each partition and reading of the endpoint fluorescent signal in two available channels for partitions meeting the required quality parameters were included. The data produced were analyzed and managed using QX Manager™ 2.1 Software (Bio-Rad Laboratories).

Optimization of the dPCR Conditions

The PCR was conducted based on officially validated qPCR protocols for MON-04032–634 and MON8978835 quantification, with some modifications. To quantify MON-04032–6 in 2011, the Italian National Reference Laboratory (NRL) organized an interlaboratory study within the Italian network, including 17 laboratories.36 The EURL-GMFF published method records a temperature of annealing and extension at 60°C in both the taxon-specific and the event-specific systems, whereas original EURL-GMFF method reported different annealing temperatures between GM and reference gene systems (60°C for lectin and 55°C for MON-04032–6 soybean). Initially, to transfer the qPCR method to the ddPCR QX200 Bio-Rad, the annealing and extension temperature was tested at 60°C. But, due to an unclear cluster separation between positive signals and background noise, an annealing temperature of 55°C was adopted. The primer and/or probe concentrations were then optimized. The final concentrations of primers and probes are listed in Table S1. Figure S1 shows the optimization of the annealing and extension temperatures, along with the primer and probe concentrations, for the MON-04032–6/lectin and MON89788/lectin.

QX200 ddPCR System

PCR was performed using a QX200 ddPCR apparatus (Bio-Rad, Pleasanton, CA, USA). The reaction volume was 20 μl containing 1× ddPCR Supermix for probes (No dUTP) (Bio-Rad, Pleasanton, CA, USA), 4 μl of DNA, 600 nM of primers, and 250 nM of probes, for both the Lec and MON-04032–6/MON89788 SOYA BEAN assay (Table S1). Droplets were generated in DG8 cartridges (Bio-Rad) loaded onto a QX200 Droplet Generator (Bio-Rad Laboratories, Inc.). Droplets were then transferred to 96-well plates amplified in a PCR thermocycler Veriti™ Thermal Cycler, 96-well Fast (Thermo Fisher Scientific, Waltham, MA, USA) with the following thermal profile: 10 min DNA polymerase activation at 95°C, 45 cycles of a two-step thermal profile of 30 s at 95°C for denaturation, and 60 s at 55°C for annealing and extension, droplets stabilization at 98°C for 10 min followed by an infinite hold at 4°C. After thermal cycling, the 96-well plates were transferred to a QX200 Droplet Reader (Bio-Rad Laboratories, Inc.) and data were analyzed using the QX Manager 2.1 Standard Edition (Bio-Rad Laboratories, Inc.). The results obtained fulfill the following acceptability criteria8 to be included in the subsequent elaborations: single peak of amplitude for the positive droplets, a number of accepted droplets above 10.000 per well per 20 μl reaction with clear discrimination between positive and negative signals, the negative control (NTC) with ≤2 fluorescent droplets and the positive control and sample were >2 fluorescent droplets. The final concentration of the target was expressed in unit copies of the target sequence per microliter of reaction.

QIAcuity dPCR System

MON-04032–6 and MON89788 were quantified using a QIAcuity One dPCR System (Qiagen). The reactions were conducted using 4x Probe PCR Master Mix, template DNA, and primers and probes at the same concentration as those used with the QX200 platform.

The reaction mixture with the DNA template was loaded into the QIAcuity Nanoplate 26k (24-well) (Qiagen, Hilden, Germany) in a total volume of 40 µl. The plate was then closed using the seal provided in the QIAcuity Nanoplate Kit (Qiagen, Hilden, Germany). The thermal cycling conditions were as follows: for the MON-04032–6 soybean assay (I) PCR initial heat activation at 95°C for 2 min, (II) 40 cycles of denaturation at 95°C for 15 s and annealing at 55°C for 30 s; for the MON89788 assay (I) PCR initial heat activation at 95°C for 2 min, (II) 55 cycles of denaturation at 95°C for 15 s and annealing at 60°C for 30 s. To check the absence of cross contamination during the plate assembly, a no-template control (NTC) was amplified in each PCR run. QIAcuity Software Suite 2.5.0.1 (Qiagen, Hilden, Germany) was used to analyze fluorescence data. The images were exposed for 500 ms with a gain of 6. The final concentration of the target was expressed as copies of the target sequence per microliter of the reaction.

The QIAcuity Software Suite reports the concentration of the target (copies/μl) with a confidence value at 95% confidence interval13.

Determination of dPCR Performance Parameters

The in-house validation study was evaluated according to the requirements defined in the document “Definition of Minimum Performance Requirements for Analytical Methods of GMO Testing Part 2 European Network of GMO Laboratories European Union Reference Laboratory for Genetically Modified Food and Feed – Part 2”25. The critical parameters assessed were specificity, cross-talk, robustness, dynamic range, linearity, asymmetric limit of quantification (LOQasym), accuracy (trueness and precision), and measurement uncertainty (MU). Six replicates per GM level tested for MON-04032–6 were analyzed by performing five runs over 5 days on the Bio-Rad Q×200 platform. On the QIAcuity platform, six replicates per GM level (% m/m) of MON-04032–6 or MON89788 were tested by five runs over 4 days.

The experimental design and technical approach of each parameter are described in Figure 1. The specificity of the duplex assays was investigated in silico using Primer-dimer software (version 2018, http://www.primer-dimer.com.) to predict oligonucleotide hybridization events, and Oligo-evaluator software (http://www.oligoevaluator.com/LoginServlet) to evaluate cross-dimer and hairpin formation.

Specificity was experimentally assessed by carrying out DNA melting curves to verify the presence of the expected pure and single amplicon37. The PCR experiment was performed using a Rotor-Gene Q 5plex Platform (Qiagen, GmbH-Hilden, Germany) instrument in a final reaction volume of 20 µl, including the 1X FAST Eva Green qPCR Master Mix (Fisher Molecular Biology, Rome, Italy), 1 ng of genomic DNA, and 300 nM each of reverse and forward primers. Two technical replicates were used for each sample. qPCR amplification was performed with the following program: an initial denaturation of 2 min at 95°C, followed by 40 cycles of 95°C for 5 s, 60°C for 30 s, and 72°C for 20 s, with one fluorescence reading per annealing step. A post-PCR DNA melting curve analysis was carried out using a temperature ramping rate of 0.1°C per step with a 30 s rest at each step.

The robustness of the method was also tested by making slight but deliberate and variable changes to the reaction conditions and assessing their impact on the method performance25. For the dPCR method, it is useful to investigate the effects of small changes in reagent concentrations and annealing temperatures, as they can occur due to random pipetting errors and temperature fluctuations in the thermocycler.

Robustness was evaluated at concentration close to the LOQ by applying some modifications to the original protocol. On QX200, four deliberate modifications were considered: (1) a 10% reduction of mastermix volume (18 µl instead of 20 µl); (2) an increase of 1°C of the annealing temperature; (3) the use of a slower ramp rate (+0.5 ºC/s); and (4) a 10% decrease of oligonucleotide concentration.

QIAcuity platform does not allow the ramp rate setting. Therefore, three deliberate modifications were tested: (1) a 10% reduction of mastermix volume; (2) an increase of 1°C of the annealing temperature; (3) a 10% decrease of oligonucleotide concentration.

We also investigated the amount of “rain” (i.e. droplets that have an intermediate fluorescence and do not seem to belong to either the positive or negative population) using the tool described in Lievens et al., 201638. The rain was calculated by using “Cloudy-V2-08. R” and an adapted version of “read_QX.R” for output data of QX Manager Software 2.1 Standard Edition. The intermediate signals (rain) should be less than 2.5% of the total number of partitions, as reported by Pecoraro et al., 20198.

Calculation of GM Content

The copy numbers for both event-specific and endogenous reference gene amplifications in each sample were reported using Quanta Soft Software.12 Finally, the GMO content in the mass fraction was calculated using the following equation reported in the application note of the European Reference Laboratory (EURL-GMFF).39

GMcontent%mm=cp GMcp taxon specific sequence×1CF GM×100

Where cp GM is the number of copies of the target per reaction, cp taxon-specific sequence is the number of copies of the lectin target per reaction, and CF GM is the conversion factor for the certified value of the CRMs used as determined by the EURL GMFF (conversion factors (CFs)) for CRMs.39

For QIAcuity the copies per microliter of the target were based on the known number of copies of the target molecule per partition (λ) and the number of accepted partition.

Measurement Uncertainty (MU)

The measurement uncertainty of the GM content of these materials was determined by considering several uncertainty sources, such as pipetting and the droplet volume in accordance with the guidance for measurement uncertainty for GMO analysis and the European technical guidance document for the laboratories quantifying GMOs operating using a flexible scope of accreditation.31,32 The detailed procedure is published by Verginelli et al. 2024.21

Results

Specificity Evaluation

The specificity of the duplex dPCR assays was verified in silico using an analysis software that reported the formation of secondary structures and changes in Gibbs free energy (ΔG) values. A ΔG value smaller than −9 kcal/mol is an absolute indicator of dimer formation. In multiplex PCR, all possible primer combinations can generate unintended PCR products if a matching template is present. No significant risk from dimers was observed between the pairs of oligonucleotides (primers/probes) (Table S2).

Specificity was experimentally evaluated by observing DNA melting peaks in the post-PCR analysis. No additional peaks were observed, thus confirming the absence of unintended products (Figure S2).

Cross-Talk

The cross-talk test was conducted in the absence of MON-04032–6 and with 59,741 lectin copies determined for non-modified soybean (ERM-BF410ap) in 3 replicates per testing condition using the Bio-Rad QX200 platform. Using the QIAcuity platform, an experiment was conducted using 2275 lectin copies. No cross-talk signals were observed on either platform. As reported in the guidelines for the verification of methods using dPCR,26 this performance parameter was considered irrelevant. However, especially with combinations of fluorophore/quencher pairs that are rarely used, depending on the instrument specifications (fluorescence channels), optional testing for optical cross-talk may be helpful.

In the case of MON89778 on the Bio-Rad QX200, this was already verified,21 whereas for QIAcuity in the absence of a GM event, 3773 lectin copies were verified.

Robustness

For both platforms, robustness was evaluated at an LOQ value corresponding to 0.05% for MON-04032–6 and 0.1% for MON89788 (already published for Q×200 in Verginelli et al., 202421 performing a multifactorial experiment design40 as shown in Figure 1.

The small deviations introduced did not significantly affect the measurement results obtained using either platform. The RSDr and bias were estimated to be below 30% at 0.05% and 0.1% GM content, respectively, for the MON-04032–6 and MON89788 soybeans (Table 1).

Table 1.

Robustness of duplex assay MON-04032–6/Lec (0.05% m/m gm level; 16 conditions) and MON89788/Lec (0.1% m/m; 8 conditions) by dPCR.

Protocol MON-04032–6
MON89788
Biorad QX200
Qiagen QIAcuity
Qiagen QIAcuity
Mean (%) RSDr (%) Bias (%) Mean (%) RSDr (%) Bias (%) Mean (%) RSDr (%) Bias (%)
Ramp rate change and annealing temp UNCHANGE Original 0.04 20.10 16.38 0.05 14.85 3.07 0.11 19.18 9.19
−10% Primer Probe −10% master mix 0.04 22.30 23.10 0.06 5.65 9.56 0.10 25.92 3.97
−10% Primer Probe 0.04 19.73 29.69 0.05 8.02 0.19 0.12 24.11 24.47
−10% Master Mix 0.04 20.52 28.91 0.05 8.96 4.55 0.12 22.59 21.51
Annealing temp +1°C No change PCR reagents 0.04 22.31 18.76 0.05 20.14 1.30 0.09 24.41 5.81
−10% Primer Probe −10% master mix 0.03 9.31 26.93 0.05 8.80 7.40 0.09 27.13 5.25
−10% Primer Probe 0.04 8.16 26.05 0.05 17.30 7.40 0.10 19.81 2.93
−10% Master Mix 0.04 13.71 28.41 0.05 10.40 0.40 0.10 9.80 0.85
Annealing temp +1°C and Ramp rate + 0.5 °C/s No change PCR reagents 0.04 13.80 26.22 a
−10% Primer Probe −10% master mix 0.04 11.97 22.45
−10% Primer Probe 0.04 9.94 24.69
−10% Master Mix 0.04 9.34 29.91
Ramp rate + 0.5 °C/s No change PCR reagents 0.04 12.77 29.25
−10% Primer Probe −10% master mix 0.04 22.07 18.07
−10% Primer Probe 0.04 11.29 19.19
−10% Master Mix 0.04 11.81 29.00

aSetting the ramp rate is not available on QIAcuity platform.

Dynamic Range

The dynamic range was assessed by estimating the trueness and precision, as reported in the ENGL Guidelines.25,27,30 The dynamic range for the MON-04032–6 soybean, covering the concentrations from 0.05% to 100% m/m GM level, met the acceptance criteria for precision (RSDr ≤25%) and trueness (Bias ≤25%) on both platforms (Table 2).

Table 2.

Dynamic range of GM MON-04032–6/Lec and MON89788/Lec was expressed as GM % and the relative values of trueness (Bias %) and precision (RSDr %). The samples were analyzed using duplex dPCR.

  MON-04032–6
MON89788
  Biorad QX200
Qiagen QIAcuity
Qiagen QIAcuity
GM level (%) Measured mean (%) RSDr (%) Bias (%) Measured mean (%) RSDr (%) Bias (%) Measured mean (%) RSDr (%) Bias (%)
0.05 0.04 23.38 20.50 0.05 10.79 2.42 / / /
0.1 0.08 14.14 21.49 0.09 13.4 14.01 0.11 19.11 9.87
0.5 0.38 9.52 24.35 0.46 23.84 7.89 0.50 18.09 0.08
1 0.77 5.99 22.92 0.81 17.27 18.86 1.10 14.25 10.10
2 1.52 8.91 24.02 1.59 13.61 20.56 2.13 6.26 6.33
10 7.99 1.75 20.06 8.03 5.42 19.66 9.96 3.68 0.38
100 96.14 1.75 2.40 95.34 2.36 4.28 98.67 2.36 0.68

On QIAcuity instrument, the dynamic range for the MON89788 soybean spanning the concentrations from 0.1% to 100% m/m GM level met the acceptance criteria for precision (RSDr ≤25%) and trueness (Bias ≤25%).

Linearity

Seven levels (% m/m) of MON-04032–6 (0.05%, 0.1%, 0.5%, 1%, 2%, 10%, 100%) and six levels (% m/m) of MON89778 (0.1%, 0.5%, 1%, 2%, 10%, 100%) were measured, and R2 and slope between the theoretical and observed values of GM% were evaluated.

R2 coefficient should be greater than or equal to 0.98, and the slope should be 1 ± 0.25, as reported in the ENGL guidelines. Duplex assays performed using the Bio-Rad QX200 and QIAgen QIAcuity platforms fulfill the acceptance criteria, exhibiting an R2 of 1 and a slope within the acceptable range (Table 3).

Table 3.

Linearity GM level duplex assays MON-04032–6/Lec (% m/m) and MON89788/Lec (% m/m).

PCR Run MON-04032-6
MON89788
QX200 Biorad
Qiagen QIAcuity
Qiagen QIAcuity
Slope Intercept R2 Slope Intercept R2 Slope Intercept R2
R 1 1.02 0.53 1.00 1.04 0.37 1.00 1.02 0.11 1.00
R 2 1.02 0.48 1.00 1.05 0.31 1.00 1.01 0.04 1.00
R 3 1.02 0.48 1.00 1.04 0.38 1.00 1.02 0.08 1.00
R 4 1.02 0.50 1.00 1.03 0.31 1.00 1.00 0.06 1.00
R 5 1.02 0.55 1.00 \ \ \ \ \ \
Mean 1.02 0.51 1.00 1.04 0.34 1.00 1.01 0.07 1.00

The correlation between the measured GM levels (% m/m) per reaction for MON-04032–6 and MON89788 is shown in Figure 2.

Figure 2.

Figure 2.

(a) Correlation between measured gm level (% m/m) per reaction of MON-04032–6/Lec using Bio-Rad QX200and Qiagen QIAcuity (b) linearity of gm MON89788/Lec on Qiagen QIAcuity platform.

Trueness

According to the ENGL guidelines,25,30 the acceptance criterion for trueness is that the measured value should be within ±25% of the accepted reference value over the whole dynamic range. The use of certified reference materials is one approach to obtain a suitable reference value, as well as a comparison with results obtained from other methods. The use of another dPCR platform with different MON-04032-6 parameters in greater depth. Trueness, expressed as relative mean bias, was below 25% across the entire dynamic range for the dPCR methods MON-04032–6 and MON89788 for both dPCR platforms, although the value was lower than the QX200 values both cases (Table 4).

Table 4.

Comparison of performance parameters for the duplex dPCR assays for MON-04032–6/Lec (a) and MON89788/Lec (b) using digital PCR.

a)
Performance parameters
  MON-04032–6
  QX200 Biorad Qiagen QIAcuity
GM level (%) N rep Measured GM (%) Sr RSDr% Ubias Bias Bias % U (%, with k=2) N rep Measured GM (%) Sr RSDr% Ubias Bias Bias % U (%, with k=2)
0.05 30 0.04 0.01 23.38 0.04 0.01 20.5 0.004 24 0.05 0.01 10.79 0.01 0.001 2.42 0.001
0.1 30 0.08 0.01 14.14 0.10 0.02 21.49 0.01 24 0.09 0.01 13.40 0.10 0.01 14.01 0.01
0.5 30 0.38 0.04 9.52 0.85 0.12 24.35 0.09 24 0.46 0.11 23.84 0.28 0.04 7.89 0.03
1 30 0.77 0.05 5.99 0.62 0.23 22.92 0.06 24 0.81 0.14 17.27 0.67 0.19 18.86 0.07
2 30 1.52 0.14 8.91 2.22 0.48 24.02 0.23 24 1.59 0.22 13.61 1.15 0.41 20.56 0.12
10 30 7.99 0.14 1.75 5.11 2.00 20.06 0.52 24 8.03 0.44 5.42 5.17 1.97 19.66 0.53
100a
30
96.14
1.68
1.75
10.16
2.36
2.40
1.44
24
95.34
2.25
2.36
10.51
4.27
4.28
1.49
b)
 
MON89788
 
Qiagen QIAcuity
GM level (%)
N rep
Measured GM (%)
Sr
RSDr%
Ubias
Bias
Bias %
U (%, with k=2)
0.05 / / / / / / / /
0.1 24 0.11 0.02 19.11 0.32 0.01 9.87 0.04
0.5 24 0.50 0.09 18.09 0.31 0.00 0.08 0.04
1 24 1.10 0.16 14.25 2.02 0.10 10.10 0.25
2 24 2.13 0.13 6.26 0.95 0.13 6.33 0.12
10 24 9.96 0.37 3.68 2.15 0.04 0.38 0.28
100 24 98.67 2.33 2.36 5.39 0.67 0.93 0.74

aCorresponding to CRM 99.6% MON-04032–6

Precision

Precision was estimated by setting up the same experiments that were performed to assess the trueness of the MON-04032–6 and MON89788 dPCR methods. Precision was calculated as RSDr at different concentration levels (% m/m) within the dynamic range under repeatability conditions within the runs and intermediate precision conditions between the runs.

As shown in Table 4, the methods satisfied this requirement for both platforms at all GM levels tested, showing an RSDr spanning from 1.75% on QX200 for the estimation of CRM 100% (m/m) and 23.84% (m/m) for 0.5% (m/m) MON-04032–06 soybean on QIAcuity dPCR.

The RSDr % was higher on QIAcuity platform with the exception of 0.05 GM% (m/m) level of MON-04032–06.

Asymmetric LOQ (LOQasym)

Thirty replicates at the 0.05% MON-04032–6 were tested for QX200 and for QIAcuity. The determined LOQasym was 38.96 copies per reaction for MON-04032–6 soya bean (Table S3) on the QX200 Bio-Rad and 25.10 copies per reaction on the QIAcuity Qiagen. For MON89788 in the QIAcuity assay, the LOQ asym value was 16.6 copies per reaction. These results were compliant with the minimum performance parameters, showing an acceptable level of precision expressed in terms of RSDr (≤25%) for both digital PCR platforms (Table S3).

Discussion

The growing number of GM events on the market requires rapid, fast and efficient methods for detection and quantification of GM them. Among numerous authorized soybean GM events, MON-04032–6 and MON89788 are the most common and specific quantification methods already validated by JRC34,35 using real-time PCR approach. In this study, we aimed to compare two digital PCR platforms: the nanoplate‐based Qiagen QIAcuity Digital PCR and the Bio-Rad QX200 Droplet Digital PCR12,13.

In this work, the qPCR assays were optimized and transferred in duplex digital PCR methods; moreover, the transferability was also evaluated on two dPCR platforms: QX200 Bio-Rad and QIAcuity Qiagen.12,13 Both platforms allow the absolute quantification of the target DNA template without the need for calibrators and standard curves, thus overcoming the shortcomings of quantitative PCR (qPCR). In digital PCR, the target quantification is obtained by dividing a bulk qPCR-like reaction mixture into numerous plenty of individual reactions called partitions; each partition is subjected to an end point PCR reaction. The number of positive partitions is directly related to concentration, and the absolute quantification is determined using the Poisson statistics. The partitioning approach is the main difference between the dPCR platforms used in this study. Actually, the absolute quantification of the target on the Bio-Rad apparatus is based on water-emulsion droplet, while on the QIAcuity dPCR system, the absolute quantification is obtained by microfluidic nanoplate technology. This different approach generates two workflows, with different technical features; e.g. samples/plate, partitions/well and input volume. For this reason, the need to compare the performance of the two platforms was identified and evaluated with this study, showing a good transferability of the MON-04032–6 and MON89788 GM soybean assays, with minor and mandatory modifications (e.g. reaction volume, mastermix). This study represents the first assessment of the GMO quantification on the QX200 and QIAcuity systems, two dPCR platforms with different fluidic partition systems and different histories; the Bio-Rad system was one of the first dPCR systems placed on the market, while QIAcuity was introduced later with a different usage approach. Fluidic partitioning is different between the two apparatuses; ddPCR has a droplet-generating system and a counter to evaluate and count the generated droplets, whereas QIAcuity has physical support for partitioning. In ddPCR, the system is optimized for at least 20,000 droplets of proper size, whereas the Qiagen apparatus uses plates with a physical partition system and allows different number of partitions to be used. The manufacturer recommends a 24,000 partitions plate for low-target quantification and GM testing. These different fluidic systems varied in terms of their outcomes. In this study, the difference in results was validated with respect to the ENGL guideline parameters, showing acceptable validation results.

Demeke et al., 202518 reported the factors that must be considered for multiplex digital PCR detection: DNA quality, quantity, presence of inhibitors, and droplet or partition volume. These elements can affect the accuracy and uncertainty of dPCR measurements41. The Qiagen dPCR system does not allow the setting of temperature gradients, which may lead to potentially inaccurate annealing during the optimization phase. Overall, we observed no annealing issues. Moreover, the robustness study conducted without setting the ramp rate confirms the validity of the results of both platforms. Overall, together with the evaluation of the “rain” we conclusively state that no inaccurate annealings were observed during the dPCR reactions.

The same CRMs were used for this validation study, and DNA was extracted using two different techniques. DNA quality was verified by performing an inhibition test to evaluate the copy number of the lectin reference gene, as described in the Materials and Methods. The observed differences were extremely small, indicating that the DNA extraction step may have a negligible impact, especially when simple matrix materials such as CRMs are analyzed.

All validation parameters, including specificity, cross-talk, robustness, dynamic range, linearity, asymmetric limit of quantification (LOQasym), accuracy (trueness and precision), and measurement uncertainty (MU), on droplet digital PCR and digital PCR in nanoplates have demonstrated comparable results in compliance with international standards42,43 and are in agreement with the ENGL document.8,25,27 The dPCR methods on the two platforms were suitable for the application of both dPCR systems for the detection and quantification of GM events for regulatory compliance.

In conclusion, digital PCR quantification of MON-04032–6 and MON89788 in a duplex assay with respect to the endogenous reference gene lectin showed concordance in terms of validation parameters between the QX200 and QIAcuity systems. Overall, this outcome highlights the suitability of the two platforms for full validation by official control laboratories.

Supplementary Material

Supplemental Material
KGMC_A_2583781_SM2149.docx (581.9KB, docx)

Acknowledgments

Conceptualization: D.Ve; Formal analysis, writing—original draft preparation: K.S.; Validation: S.C., D.V., A.B., K.S; Writing, review editing and Visualization: D.Ve; data curation: D.L.R; investigation: S.C, A.B and D.V; Writing, review and editing D.V, A.B and E.P; supervision: U.M.

All authors have read and agreed to the published version of the manuscript

Funding Statement

This study was funded by the Italian Ministry of Health under the current research framework, research code IZSLT RC LT11/23 [G89I23001500001].

Disclosure Statement

No potential conflict of interest was reported by the author(s).

Data Availability Statement

Data associated with this manuscript can be accessed online at …

Supplementary Material

Supplemental data for this article can be accessed online at https://doi.org/10.1080/21645698.2025.2583781

References

  • 1.Cheng X, Li , Li H, Tang Qu , Zhang H, Liu T, Wang Y.. Trends in the global commercialization of genetically modified crops in 2023. J Integr Agric. 2024;23(12):3943–52. doi: 10.1016/j.jia.2024.09.012. [DOI] [Google Scholar]
  • 2.European Union law . Eur-Lex access to European Union law. Regulation (EC) No 1829/2003 of the European Parliament and of the Council of. 2003. Sep 22 on genetically modified food and feed. [Google Scholar]
  • 3.European Parliament, Council of the European Union. Regulation (EC) No 1830/2003 of the European Parliament and of the Council of 22 September 2003 Concerning the Traceability and Labelling of Genetically Modified Organisms and the Traceability of Food and Feed Products Produced from Genetically Modified Organisms and Amending Directive 2001/18/ECl; Publications Office of the European Union: Luxembourg, 2003.
  • 4.EN. IEC 17025 . General requirements for the competence of testing and calibration laboratories. 2005.
  • 5.Demeke T, Jenkins GR.. Influence of DNA extraction methods, PCR inhibitors and quantification methods on real-time PCR assay of biotechnology-derived traits. Anal Bioanal Chem. 2010;396(6):1977–90. doi: 10.1007/s00216-009-3150-9. [DOI] [PubMed] [Google Scholar]
  • 6.Pavšič J, Žel J, Milavec M. Assessment of the real-time PCR and different digital PCR platforms for DNA quantification. Anal Bioanal Chem. 2016. Jan. 408(1):107–21. doi: 10.1007/s00216-015-9107-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Vogelstein B, Kinzler KDP. Proc Natl Acad Sci USA. Proc Natl Acad Sci, India, Sect B Biol Sci. 1999. Aug 3. 96(16):9236–41. doi: 10.1073/pnas.96.16.9236. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Pecoraro S, Berben G, Burns M, Corbisier P, De Giacomo M, De Loose M, Dagand E, Dobnik D, Eriksson R, Holst-Jensen A. Overview and recommendations for the application of digital. PCR European Network of GMO Laboratories (Engl.). 2019. [Google Scholar]
  • 9.Burns MJ, Burrell AM, Foy CA. The applicability of digital PCR for the assessment of detection limits in GMO analysis. Eur Food Res Technol. 2010;231(3):353–62. doi: 10.1007/s00217-010-1277-8. [DOI] [Google Scholar]
  • 10.Iwobi A, Gerdes L, Busch U, Pecoraro S. Droplet digital PCR for routine analysis of genetically modified foods (GMO) – a comparison with real-time quantitative PCR. Food Control. 2016;69:205–13. doi: 10.1016/j.foodcont.2016.04.048. [DOI] [Google Scholar]
  • 11.Grelewska-Nowotko K, Żurawska-Zajfert M, E Ż, Sowa S. Optimization and verification of droplet digital PCR even-specific methods for the quantification of GM maize DAS1507 and NK603. Appl Biochem Biotechnol. 2018. May. 185(1):207–20. doi: 10.1007/s12010-017-2634-x. [DOI] [PubMed] [Google Scholar]
  • 12.Bio-Rad . Droplet digital™ PCR droplet digital™ PCR applications guide. Hercules (CA): Bio-Rad Laboratories, Life Science Group; 2018. [Google Scholar]
  • 13.Qiagen . QIAcuity digital PCR system. https://www.qiagen.com/us/products/instruments-and-automation/pcr-instruments/qiacuity-digital-pcr-system.
  • 14.Basu AS. Digital assays part I: partitioning statistics and digital PCR. SLAS Technol. 2017. Aug. 22(4):369–86. doi: 10.1177/2472630317705680. [DOI] [PubMed] [Google Scholar]
  • 15.Bogožalec Košir AB, Demšar T, Štebih D, Žel J, Milavec M. Digital PCR as an effective tool for GMO quantification in complex matrices. Food Chem. 2019. Oct 1. 294:73–78. doi: 10.1016/j.foodchem.2019.05.029. [DOI] [PubMed] [Google Scholar]
  • 16.Dobnik D, D Š, Blejec A, Morisset D, J Ž. Multiplex quantification of four DNA targets in one reaction with Bio-Rad droplet digital PCR system for GMO detection. Sci Rep. 2016;6(1):35451. doi: 10.1038/srep35451. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Long L, Yan W, He Y, Dong L, Xing Z, Li C, Xia W, Li F. Development of a duplex digital PCR method to quantify five genetically modified soybean events. Food Anal Methods. 2022;15(2):294–306. doi: 10.1007/s12161-021-02104-2. [DOI] [Google Scholar]
  • 18.Demeke T. Considerations for the successful detection and quantification of genetically modified events in grain and food samples using multiplex digital PCR. Foods. 2024. Dec 31. 14(1):75. doi: 10.3390/foods14010075. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Košir AB, Spilsberg B, Holst-Jensen A, J Ž, Dobnik D. Development and inter-laboratory assessment of droplet digital PCR assays for multiplex quantification of 15 genetically modified soybean lines. Sci Rep. 2017;7(1):8601. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Demeke T, Eng M. Detection of soybean GMO events using two multiplex droplet digital PCR assays. J AOAC Int. 2025. Jan 1. 108(1):23–28. doi: 10.1093/jaoacint/qsae082. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Verginelli D, Ciuffa S, Spinella K, La Rocca D, Misto M, Quarchioni C, Bonini P, Fusco C, Peroni L, Peddis S, et al. In-house validation of four duplex droplet digital PCR assays to quantify GM soybean events. Foods. 2024. Dec 11. 13(24):4011. doi: 10.3390/foods13244011. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Noma S, Kikuchi Y, Satou M, Tanaka T, Takiya T, Okusu H, Futo S, Takabatake R, Kitta K, Mano J. Simple, precise, and less biased GMO quantification by multiplexed genetic element-specific digital PCR. J AOAC Int. 2022. Feb 4. 105(1):159–66. doi: 10.1093/jaoacint/qsab138. [DOI] [PubMed] [Google Scholar]
  • 23.Kim EH, Cho YS, Kim B, Yoo Y, Lee JI, Kim YS, Park TS. Development of a duplex chamber digital PCR to quantify twelve genetically modified maize events. GM Crops Food. 2025. Dec. 16(1):527–38. doi: 10.1080/21645698.2025.2548053. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Brara Z, Madani K, Costa J, Taouzinet L, Djaoudene O, Amrane-Abider M, Bougherra H, Mouhoubi K, Brahimi N, Bouiche C, et al. Current progress on the detection of genetically modified organisms in food: from transgenic towards genome-edited crops. Compr Rev Food Sci Food Saf. 2025. Sep. 24(5):e70243. doi: 10.1111/1541-4337.70243. [DOI] [PubMed] [Google Scholar]
  • 25.Gatto F, Savini C, Baillie CK, Broothaerts W, Burns M, Dagand E, Debode F, Dobnik D, Grantina-Levina L, Grohmann L. Definition of minimum performance requirements for analytical methods of GMO testing. Part 2, European Network of GMO Laboratories. European Union Reference Laboratory for Genetically Modified Food and Feed. Publications Office of the European Union; 2023. https://data.europa.eu/doi/10.2760/63656. [Google Scholar]
  • 26.Weidner C, Frenzel J, Bartsch D, Waiblinger HU, Mankertz J. Guideline for the verification of digital PCR methods in analytical GMO testing. J Consum Prot Food Saf. 2024;19(3):335–37. doi: 10.1007/s00003-024-01516-6. [DOI] [Google Scholar]
  • 27.Grohmann L, Barbante A, Eriksson R, Gatto F, Georgieva T, Huber I, Hulin J, Köppel R, Marchesi U, Marmin L, et al. Guidance document on multiplex real-time PCR methods. En: Luxembourg: Publications Office of the European Union, 30708; EUR; 2021. [Google Scholar]
  • 28.ISO 20395 . Biotechnology – requirements for evaluating the performance of quantification methods for nucleic acid target sequences – qPCR and dPCR. Geneva (Switzerland): ISO; 2019. [Google Scholar]
  • 29.Nijland JAB, Hokken MWJ, Prins TW. Set-up and in-house validation of two multiplex event-specific PCR methods to simplify screening for GMOs without common screening elements. J Food Compos Anal. 2024;125:105722. doi: 10.1016/j.jfca.2023.105722. [DOI] [Google Scholar]
  • 30.Mazzara M, Delobel C, Savini C. Definition of minimum performance requirements for analytical methods of GMO testing. Luxembourg: European Network of GMO Laboratories (ENGL) Publications Office of the European Union. 2008. [Google Scholar]
  • 31.Trapmann S, Burns M, Corbisier P, Gatto F, Robouch P, Sowa S, Emons H. Guidance document on measurement uncertainty for gmo testing laboratories. 3rd ed. Luxembourg: Publications Office of the European Union; 2020. [Google Scholar]
  • 32.Trapmann S, Delobel C, Corbisier P, Emons H, Hougs L, Philipp P, Sandberg M, Schulze M. European technical guidance document for the flexible scope accreditation of laboratories quantifying GMOs. Luxembourg: Publications Office of the European Union. 2013. [Google Scholar]
  • 33.Hougs L, Gatto F, Goerlich O, Grohmann L, Lieske K, Mazzara M, Narendja F, Ovesna J, Papazova N, Scholtens I. Verification of analytical methods for GMO testing when implementing interlaboratory validated methods. version 2. 2017.
  • 34.European Union Reference Laboratory for GM Food and Feed (EURL GMFF) . Joint research Centre (JRC), European commission. Event-specific method for the quantification of soybean line 40-3-2 using real-time PCR - JRC validated methods, reference methods and measurements report - corrected. version 1. Luxembourg: Publications Office of the European Union. 2017. [Google Scholar]
  • 35.Delobel C, Bogni A, Pinski G, Mazzara M, Den Eede G V. Event-specific method for the quantification of soybean line MON 89788 using real-time PCR v. 1.01 – validation report and protocol. Luxembourg: Publications Office of the European Union. 2013. [Google Scholar]
  • 36.Gatto F, Paternò A, Ciabatti I, Marchesi U, Amaddeo D. Report of the collaborative study for the validation of real time PCR methods for GMO screening. [Technical report]. 2011: https://www.izslt.it/crogm/wpcontent/uploads/sites/5/2019/04/CROGM_report_screening-1.pdf.
  • 37.Sinha M, Mack H, Coleman TP, Fraley SI. A high-resolution digital DNA melting platform for robust sequence profiling and enhanced genotype discrimination. SLAS Technol. 2018;23(6):580–91. doi: 10.1177/2472630318769846. [DOI] [PubMed] [Google Scholar]
  • 38.Lievens A, Jacchia S, Kagkli D, Savini C, Querci M. Measuring digital PCR quality: performance parameters and their optimization. PLOS ONE. 2016;11(5). doi: 10.1371/journal.pone.0153317. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.EURLGMFF . European Union reference laboratories for genetically modified food and feed. Use of the harmonised conversion factors to transform PCR results from the DNA copy number ratio domain into the mass fraction domain: application note. V1.0. Brussels, Belgium: European Union; 2019. [Google Scholar]
  • 40.Montgomery DC. Design and analysis of experiments. Hoboken (NJ): John Wiley & Sons; 1991. [Google Scholar]
  • 41.Košir AB, Divieto C, J P, Pavarelli S, Dobnik D, Dreo T, Bellotti R, Sassi MP, J Ž. Droplet volume variability as a critical factor for accuracy of absolute quantification using droplet digital PCR. Anal Bioanal Chem. 2017;409(28):6689–97. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42.Chapela MJ, et al. Guidelines on performance criteria and validation of methods for detection, identification and quantification of specific DNA sequences and specific proteins in foods . Codex Alimentarius, CAC/GL. 2010;74. [Google Scholar]
  • 43.ISO 5725-1 . Accuracy (trueness and precision) of measurement methods and results – Part 1: General principles and definitions. 1994.

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplemental Material
KGMC_A_2583781_SM2149.docx (581.9KB, docx)

Data Availability Statement

Data associated with this manuscript can be accessed online at …


Articles from GM Crops & Food are provided here courtesy of Taylor & Francis

RESOURCES