Skip to main content
. 2025 Nov 15;18:15959–15971. doi: 10.2147/JIR.S539688

Table 4.

Performance of the Five Models in the Training and Test Sets

Model AUC (95% CI) Specificity Accuracy Sensitivity
Combined model 0.97 (0.936–1) 0.972 0.954 0.864
Radiomics model 0.903 (0.845–0.961) 0.872 0.847 0.727
Training set Clinical model 0.66 (0.55–0.77) 0.651 0.634 0.545
BISAP model 0.62 (0.504–0.736) 0.578 0.588 0.636
MRSI model 0.804 (0.714–0.894) 0.725 0.748 0.864
Combined model 0.979 (0.947–1) 0.854 0.877 0.857
Radiomics model 0.831 (0.723–0.939) 0.75 0.772 0.889
Test set Clinical model 0.743 (0.59–0.896) 0.75 0.702 0.444
BISAP model 0.668 (0.51–0.826) 0.667 0.649 0.556
MRSI model 0.731 (0.537–0.926) 0.75 0.754 0.778

Abbreviations: AUC, area under the curve; BISAP, bedside index for severity in acute pancreatitis; MRSI, magnetic resonance severity index.