Year TIN cases (n) Reported ADEs with statins ROR (95% CI) PRR EBGM IC
2017 5 7,646 0.80 (0.33–1.92) 0.8 0.81 −0.30
2018 9 9,639 0.41 (0.21–0.80) 0.41 0.43 −1.22
2019 2 12,089 0.07 (0.017–0.27) 0.07 0.08 −3.55
2020 12 10,088 1.13 (0.64–2.00) 1.13 1.13 0.17
2021 17 7,656 2.08 (1.29–3.35) 2.08 2.01 1.00
2022 16 6,976 2.89 (1.76–4.74) 2.89 2.71 1.44
2023 17 7,754 2.40 (1.49–3.88) 2.4 2.3 1.20
2024 42 8,503 5.77 (4.24–7.85) 5.75 5.32 2.41