Abstract
Background:
Precise gingival retraction is critical for accurate impressions in restorative dentistry. Minimizing tissue trauma while achieving adequate displacement remains a key clinical challenge.
Aim:
To evaluate and compare gingival displacement using four techniques – retraction cord, retraction paste, retraction gel, and diode laser – via intraoral scanning, and assess associated gingival inflammation by measuring interleukin-1β (IL-1β) levels.
Materials and Methods:
Eighty participants requiring maxillary anterior full-coverage restorations were randomly divided into four groups (n = 20): Group 1-retraction cord, Group 2-retraction paste, Group 3-hemostatic gel, and Group 4-laser. Horizontal and vertical gingival displacement was measured pre- and post-retraction using Computer-aided design (CAD) and computer-aided manufacturing (CAM) software. Gingival crevicular fluid was collected at baseline, day 1, and day 7 for IL-1β analysis through the enzyme-linked immunosorbent assay. Data were analyzed using the one-way ANOVA and paired t-tests (P < 0.05).
Results:
All methods achieved >0.22 mm displacement. Laser retraction showed the greatest displacement, followed by cord, paste, and gel. IL-1β levels increased postretraction, with cord showing the highest inflammatory response. No significant IL-1β differences were found among paste, gel, and laser groups at day 1.
Conclusions:
Laser and cord techniques provided superior gingival displacement. However, laser and other cordless methods induced less inflammation, making them preferable for atraumatic gingival management.
Keywords: Astringent paste, digital intraoral impression, impregnated retraction cord, laser, proinflammatory cytokines, retraction gel, tissue displacement
INTRODUCTION
Periodontal tissue health depends on properly designed restorations with margins placed approximately 0.5 mm below the free gingival margin and 3–4 mm above the alveolar bone crest to preserve biologic width, as incorrectly placed margins violate it.[1,2] Precise marginal adaptation relies on effective gingival displacement to ensure accurate impressions and restoration longevity.[3] Gingival displacement techniques facilitate the exposure of subgingival finish lines by temporarily displacing tissue, controlling crevicular fluid, and minimizing bleeding.[4]
Traditional methods include mechanical, chemical, chemo-mechanical, and surgical techniques.[5] Retraction cords remain the gold standard, mechanically displacing tissue through packing into the sulcus. Available in twisted, knitted, or braided forms, they are often impregnated with hemostatic agents such as aluminum chloride and ferric sulfate. Sure Cord Plus is a knitted, split microfiber cord impregnated with aluminum chloride, providing superior fluid absorption and gentle hemostasis, although cord placement is time-consuming and may cause mechanical trauma.[6,7]
Recently, cordless techniques have gained popularity, utilizing a chemo-mechanical mechanism by injecting specialized paste into the sulcus. They enable faster, more efficient retraction with improved gingival health, reduced sulcular fluid, less patient discomfort, and require lower application pressure.[1] 3M Astringent Retraction Paste delivers 15% aluminum chloride through an extra-fine tip for gentle lateral displacement, while Hemostaz Retraction Gel by Maarc contains 25% buffered aluminum chloride in a thixotropic, nondripping gel for effective tissue management.
Recent advancements in dentistry include the use of lasers such as diode, Nd: YAG, CO2 for procedures such as gingival retraction, dentin hypersensitivity, and soft-tissue surgeries.[8] Diode lasers (810–980 nm) provide precise tissue ablation with simultaneous hemostasis, offering minimal mechanical trauma and reduced bleeding.[7,9]
Gingival displacement triggers transient inflammation by releasing Interleukin (IL)-1β, which lead to extracellular matrix degradation and periodontal tissue destruction.[10] Retraction cords cause reversible periodontitis-like changes due to sulcular trauma, while chemical agents may elevate cytokine levels and exacerbate bone resorption. Laser method, although minimally invasive, can still induce mild inflammation from thermal effects.[9,11,12]
Earlier gingival displacement has been assessed using various techniques such as calipers, microscopy, and extraoral scanning but intraoral scanning (IOS) has been used in this study as it offers superior accuracy and patient comfort.[13]
Till now, no randomized controlled trial has concurrently compared chemo-mechanical, chemical, and surgical gingival displacement techniques while correlating the displacement achieved with inflammatory cytokine levels, making this investigation novel. Hence, this in vivo study aimed to compare gingival displacement achieved through chemomechanical, chemical, and surgical methods using IOS and evaluate their impact on IL-1β levels at different time intervals.
MATERIALS AND METHODS
All procedures were approved by the institutional ethical committee (ITSCDSR/IIEC/LD/CONS/2023-26/005) which was then registered in the Clinical Trials Registry of India (CTRI/2024/11/076744) and have been reported following Consolidated Standards of Reporting Trials Statement guidelines [Figure 1].
Figure 1.
Consolidated Standards of Reporting Trials Statement flow diagram
In this randomized, double-blinded clinical trial, a total of 120 participants were screened, of which 80 meeting the inclusion criteria were enrolled after obtaining informed consent from each patient. Patients indicated for full-coverage restorations in maxillary anterior teeth with ≥2 mm keratinized gingiva, probing depth <3 mm, no attachment loss, recession, bleeding on probing, fibrotic or highly scalloped gingiva, and plaque and gingival index scores of 0 or 1 were included. Additional inclusion criteria were age >18 years, nonsmokers or those who had ceased smoking ≥6 months prior, and absence of malocclusion or rotation. Exclusion criteria included periodontal disease, grossly decayed or malpositioned abutments, systemic conditions (e.g., diabetes, hypertension, and cardiovascular disorders), pregnancy, lactation, alcohol abuse, and history of specific drug use.
Randomization and group allocation
Eligible participants (n = 80) were randomly allocated into four groups (n = 20 per group) based on the gingival displacement method. Randomization was done using an open software www.randomizer.org. The allocation concealment was done according to Sequentially numbered, opaque, sealed envelope (SNOSE) method and both the participants and assessors were unaware of the tested material.
Group 1 (SURE CORD PLUS): Retraction cord impregnated with 5% aluminum chloride
Group 2 (3M ESPE retraction capsule): Retraction paste containing 15% aluminum chloride
Group 3 (MAARC Hemostaz gel): Retraction gel with 25% aluminum chloride
Group 4 (DIODE LASER): Laser-assisted gingival displacement.
Clinical procedures
Preoperative scanning
Digital intraoral scans (STL format) were obtained before retraction to record baseline gingival dimensions.
Tooth preparation
After preoperative scanning, the abutment teeth were prepared to receive full coverage all-ceramic restorations, with equigingival shoulder finish lines. Point indentations were made at mesio-buccal, mesio-lingual, disto-buccal, disto-lingual, and mid-buccal points to measure sulcular dimensions pre-and post-retraction.
Gingival retraction techniques
Group 1: A gingival cord packer was used to place a size 000 retraction cord. The single-cord technique was adopted and applied for a duration of 2 min [Figure 2a]
Group 2: The 3M ESPE retraction-paste cartridge was attached to its dispensing tip, inserted into the sulcus and slowly delivered without compressing the gingiva, maintaining light contact with the tooth surface for 2 min [Figure 2b]
Group 3: Gel was injected into the sulcus and retained for 2 min [Figure 2c]
Group 4: A diode laser operating at a wavelength of 980 nm was utilized. The procedure followed the preset gingivectomy mode, delivering 1.0 W power in continuous wave through a 300 μm diameter optical fiber. The laser’s optical tip was angled toward the soft tissue, carefully kept away from the prepared tooth and gently passed along the gingival sulcus to remove the sulcular epithelium creating a uniform 360-degree trough around the tooth [Figure 2d].
Figure 2.

Retraction methods. (a) Retraction cord in sulcus, (b) 15% AlCl3 paste in sulcus, (c) 25% AlCl3 Gel in sulcus, (d) diode laser troughing
Postoperative scanning
Digital scans were repeated postretraction to measure displacement using CAD/CAM software.
Horizontal and vertical displacement
Gingival retraction was assessed at the point indentations made on the tooth. The average vertical and lateral displacement was determined using the measurement tool of Exocad CAD-CAM software. The horizontal displacement was determined by measuring the horizontal distance from the point indentation on the tooth to the gingival crest, calculated as the difference between pre- and post-retraction widths. Similarly, vertical displacement was determined by measuring the distance vertically from the point indentation on the tooth to the free gingival margin, calculated as the difference between pre- and post-retraction measurements.
Clinical procedures for the biochemical analysis of proinflammatory cytokine levels
Collection of Gingival Crevicular Fluid (GCF): GCF samples were collected using calibrated volumetric microcapillary pipettes positioned extracrevicularly at the gingival margin. A total of 2 μL GCF was obtained from the sulcus at three time points: baseline (day 0), day 1 (posttooth preparation and gingival displacement), and day 7, across all three experimental groups. Samples were transferred into Eppendorf tubes containing 1 mL phosphate-buffered saline and stored at −70°C until analysis
Evaluation of IL-1β: IL-1β levels were assessed using a commercial IL-1β enzyme-linked immunosorbent assay (ELISA) kit (Diaclone SAS, France).
Statistical analysis
The data were analyzed using the SPSS statistical software 23.0 Version(SPSS Inc., Chicago, IL, USA). The descriptive statistics included mean and standard deviation. The intergroup comparison was done using one-way ANOVA to find the difference between the groups. The intragroup comparison between the time intervals was done using the paired t-test. The level of the significance was fixed at 5%. The Shapiro–Wilk test was used to investigate the distribution of the data and Levene’s test to explore the homogeneity of the variables.
RESULTS
The results suggest that all four gingival retraction methods produced a gingival displacement >0.22 mm, which is considered the minimum required for accurately capturing gingival finish lines.
Intergroup comparison revealed that Group 4 exhibited the highest mean horizontal displacement, followed by Group 1, Group 2, and Group 3. The results were statistically significant (P < 0.05), except between Groups 3 and 4, where the results were not statistically significant (P > 0.05) [Table 1].
Table 1.
Intergroup and intragroup comparison of horizontal and vertical displacement between the groups
| Horizontal displacement | Vertical displacement | |||||||
|---|---|---|---|---|---|---|---|---|
|
|
|
|||||||
| Group 1, mean±SD | Group 2, mean±SD | Group 3, mean±SD | Group 4, mean±SD | Group 1, mean±SD | Group 2, mean±SD | Group 3, mean±SD | Group 4, mean±SD | |
| Mesiobuccal | 0.389±0.086A | 0.358±0.046a,B | 0.354±0.053a,C | 0.411±0.103D | 0.369±0.0661 | 0.337±0.026i,2 | 0.334±0.033i,3 | 0.390±0.0834 |
| Mesiolingual | 0.380±0.071A | 0.345±0.091b,B | 0.345±0.049b,C | 0.399±0.066D | 0.360±0.0511 | 0.326±0.071ii,2 | 0.325±0.029ii,3 | 0.378±0.0464 |
| Mid buccal | 0.377±0.102A | 0.356±0.047c,B | 0.355±0.048c,C | 0.389±0.046D | 0.358±0.0821 | 0.336±0.027iii,2 | 0.335±0.028iii,3 | 0.368±0.0264 |
| Distobuccal | 0.377±0.092A | 0.354±0.042d,B | 0.352±0.050d,C | 0.396±0.058D | 0.355±0.0721 | 0.334±0.022iv,2 | 0.332±0.030iv,3 | 0.366±0.0384 |
| Distolingual | 0.380±0.101A | 0.355±0.036e,B | 0.353±0.040eC | 0.398±0.064D | 0.360±0.0811 | 0.337±0.016v,2 | 0.333±0.020v,3 | 0.368±0.0444 |
Same superscript along the row in lowercase shows statistically nonsignificant difference for horizontal displacement, Same superscript along the column in uppercase shows statistically nonsignificant difference for horizontal displacement, Same superscript along the row in roman number shows statistically nonsignificant difference for vertical displacement, Same superscript along the column in Arabic number shows statistically nonsignificant difference for vertical displacement. SD: Standard deviation
A similar trend was also noted in vertical displacement, with Group 4 exhibiting the highest mean, followed by Group 1, Group 2, and Group 3 [Table 1].
Intragroup comparison of horizontal and vertical displacement showed no statistically significant differences among all groups at all sites [Table 1].
The intergroup comparison of IL levels revealed no statistically significant differences on day 0 among all the groups (P > 0.05). On day 1, Group 1 had significantly higher IL-1β concentration compared to Group 3, Group 2, and Group 4. On day 7, the decrease in IL-1β was significant in Group 4 in comparison to other groups [Table 2].
Table 2.
Intergroup and intragroup comparison of interleukin-1β between the groups
| Group 1, mean±SD | Group 2, mean±SD | Group 3, mean±SD | Group 4, mean±SD | |
|---|---|---|---|---|
| Day 0 | 28.910±5.392a | 28.700±7.372a | 27.680±7.651a | 28.700±7.372a |
| Day 1 | 59.160±8.890A | 48.870±8.991b,B | 50.950±8.578b,C | 46.870±7.991b,D |
| Day 7 | 52.630±7.045c,A | 47.430±6.012c,B | 48.180±7.424c,C | 40.180±6.424D |
Same superscript along the row in the lowercase shows statistically nonsignificant difference, Same superscript along the column in the uppercase shows statistically nonsignificant difference. SD: Standard deviation
Statistical analysis showed that intragroup comparisons between day 0 and day 1, as well as between day 0 and day 7, were statistically significant (P < 0.05). However, comparison between day 1 and day 7 did not show statistically significant differences (P > 0.05) [Table 2].
DISCUSSION
Gingival displacement is a critical step in restorative procedures for accurate margin capture and long-term periodontal health. Different gingival displacement techniques vary in their effectiveness and impact on soft tissues. The inflammatory response elicited by these methods can influence healing and restoration success. By evaluating IL-1β levels and using IOS, this study provides important insights into tissue response, guiding clinicians in choosing methods that optimize impression accuracy and minimize inflammation.
Knitted impregnated retraction cord (#000) was employed in this study owing to its proven superiority in achieving greater gingival displacement, effective control of hemorrhage and crevicular fluid, and its adaptability to narrow anterior sulci. The 3M Astringent Paste containing 15% aluminum chloride was selected as a cordless alternative, providing advantages such as reduced chair time, improved patient comfort, and atraumatic tissue management. Hemostaz Retraction Gel with 25% aluminum chloride was incorporated to assess the effect of a higher concentration of the same agent. The diode laser (980 nm) was included for its precise and minimally invasive tissue management, as it has been shown to promote faster healing and induce less inflammation and gingival recession compared to conventional cord techniques. Finally, digital IOS was chosen over conventional impression methods due to its superior accuracy in capturing finish lines, decreased patient discomfort and reduced chairside time.
Laser troughing demonstrated the greatest displacement across all sites and also lowest IL-1β levels. Diode lasers are selectively absorbed by pigmented tissues such as hemoglobin and melanin with minimal interaction with dental hard tissues, enabling effective soft-tissue cutting, coagulation, vaporization, or ablation with minimal collateral damage.[7] Dawani et al.[14] noted that preserving basal cell layers during gingival retraction reduces trauma and recession. Diode lasers achieve this by removing superficial epithelium while protecting the basal layer and vasculature, minimizing bleeding.[7]
These findings align with previous studies by Goutham et al.,[15] Aldhuwayhi,[16] and Abdelhamid et al.[17] Stuffken (2016)[9] further emphasized the minimally invasive nature of lasers, noting reduced gingival recession after 30 days compared to traditional methods.
However, contrasting results reported by Solimei et al. may be due to their in vitro study design which does not replicate in vivo tissue responses.[18]
The significant gingival displacement observed with retraction cords is attributed to their chemico-mechanical action. The SURE-Cord used has a stable loop structure that expands to exert gentle lateral pressure, aiding in gingival displacement and fluid absorption. The inclusion of AlCl3 enhances this effect by promoting hemostasis through protein precipitation, vasoconstriction, and tissue fluid extraction, without compromising the cord’s absorbent capacity.[1]
Retraction pastes showed reduced gingival displacement, likely due to lower pressure than cords. Bennani et al. reported KnitTrax cords, Expasyl paste, and 3M ESPE Astringent Retraction Paste produced 5396 kPa, 143 kPa, and 38.8 kPa of pressure.[19]
However, the present findings differ from those of Qureshi et al., possibly due to the use of different cord types – braided in their study versus knitted in the present investigation.[20]
The 3M Astringent Paste capsule has a long, thin tip with a soft tip for precise sulcus placement, and a probe-like orientation ring for deep filling with minimal trauma.[1,21] This may explain why 15% AlCl3 showed greater displacement than 25% AlCl3.
Mechanical trauma and the use of astringents during retraction can stimulate a gingival inflammatory response, leading to elevated IL-1β levels on day 1 across all groups.[22] This aligns with findings by Igić et al.,[11] who observed mild to moderate acute gingival inflammation 1 day postretraction.
In contrast, retraction cords applied with hand instruments can exert excessive mechanical force. Van der Velden reported epithelial attachment damage at 1 N/mm² and rupture at 2.5 N/mm², levels common with cord use. Phatale et al.[23] observed epithelial stripping and degeneration histologically with cords. Wang et al.,[24] in a systematic review and meta-analysis, concluded that retraction pastes are superior to cords in preserving periodontal health, supporting the present study’s finding of highest IL-1β expression with cord use.
A key strength of this in vivo study is its comprehensive evaluation of gingival retraction techniques from both mechanical and biological perspectives. It is the first to compare chemomechanical, chemical, and surgical methods for lateral and vertical gingival displacement using IOS. In addition, IL-1β levels in GCF were measured, offering valuable insight into the correlation between retraction methods and tissue-level inflammation. Unlike previous studies focusing mainly on displacement, this research reflects real clinical conditions and provides deeper understanding of biocompatibility. The use of sensitive ELISA testing enhances the objectivity of cytokine analysis. Clinically, the findings highlight the need to choose retraction methods that balance effective tissue displacement with minimal trauma.
Despite its strengths, the present study has certain limitations. First, the sample size, although adequate for preliminary comparisons, may limit the generalizability of the findings across populations with varying periodontal health. A larger, more diverse sample could better reflect how different tissue biotypes respond to retraction methods. Second, while biomarkers such as IL-1β offer insights into the inflammatory response, the study focused only on the short-term changes. Longitudinal assessment would help clarify the long-term effects on periodontal tissues. In addition, patient-reported outcomes such as discomfort, bleeding, or satisfaction were not evaluated, which are important for comprehensive clinical assessment. The exclusion of histological analysis is another limitation, as microscopic evaluation could have complemented the biomarker data.
Future research should include larger, diverse populations, long-term outcomes, patient-centered evaluations, histology, advanced imaging, and minimally invasive technologies to optimize the retraction protocols within digital workflows.
CONCLUSIONS
Within the limitation of this study, the following conclusion can be drawn:
Lasers provided the highest gingival displacement and minimal trauma to the gingival tissues, making it not only efficient but also the most biologically considerate option
Cord was significantly better than paste and gel in comparison of the gingival displacement
Cord showed statistically more increase in the IL-1β levels at all the time periods.
Clinical significance
Diode – laser retraction yields optimal gingival displacement with minimal IL-1β release and is significantly less traumatic than cord or paste techniques.
Recommendation
Based on the findings of the present study, diode laser retraction is recommended as the material of choice for optimal displacement with minimal inflammation, while cords may be used as an alternative if lasers are unavailable.
Conflicts of interest
There are no conflicts of interest.
Funding Statement
Nil.
REFERENCES
- 1.Madaan R, Paliwal J, Sharma V, Meena KK, Dadarwal A, Kumar R. Comparative evaluation of the clinical efficacy of four different gingival retraction systems: An in vivo study. Cureus. 2022;14:e23923. doi: 10.7759/cureus.23923. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Nugala B, Kumar BS, Sahitya S, Krishna PM. Biologic width and its importance in periodontal and restorative dentistry. J Conserv Dent. 2012;15:12–7. doi: 10.4103/0972-0707.92599. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Beleidy M, Serag Elddien A. Clinical comparative evaluation of different retraction systems in gingival displacement and their influence on periodontal health: A randomized clinical trial. Egypt Dent J. 2020;66:1667–78. [Google Scholar]
- 4.Kazakova R, Vlahova A, Tomov G, Dimitrova M, Kazakov S, Zlatev S, et al. A comparative analysis of post-retraction changes in gingival height after conventional and surgical gingival displacement: Rotary curettage, diode and Er: YAG laser troughing. Healthcare (Basel) 2023;11:2262. doi: 10.3390/healthcare11162262. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Mehra N, Rathi A, Sharma R, Kaushik M, Sood T. Evaluation of alpha-adrenomimetic agents for gingival retraction: A randomized crossover clinical trial. J Conserv Dent. 2019;22:533–7. doi: 10.4103/JCD.JCD_76_19. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Bandi M, Mallineni SK, Nuvvula S. Clinical applications of ferric sulfate in dentistry: A narrative review. J Conserv Dent. 2017;20:278–81. doi: 10.4103/JCD.JCD_259_16. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Diwan V, Chauhan MR, Tembhurne J, Gangurde A, Wani H, Danane S. Comparative evaluation of the effect of impregnated retraction cord versus laser on gingival attachment level and pain perception following retraction for subgingival margins –A prospective, split-mouth, controlled, clinical study. J Indian Prosthodont Soc. 2024;24:136–43. doi: 10.4103/jips.jips_437_23. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Siddiqui S, Khan M, Chandra R, Tripathi S, Jain J, Tiwari UO. Comparative evaluation of the efficacy of light amplification by the stimulated emission of radiation, desensitizing agents, and their combined effect on dentinal hypersensitivity in cuspids and bicuspids – In vivo study. J Conserv Dent. 2022;25:363–8. doi: 10.4103/jcd.jcd_47_22. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Stuffken M, Vahidi F. Preimpression troughing with the diode laser: A preliminary study. J Prosthet Dent. 2016;115:441–6. doi: 10.1016/j.prosdent.2015.10.008. [DOI] [PubMed] [Google Scholar]
- 10.Jain S, Sundar S, Haritha JS, Natanasabapathy V. Comparision of interleukin-1β concentrations in posttreatment endodontic disease and other pulpal and periapical conditions –A clinical study. J Conserv Dent Endod. 2024;27:843–8. doi: 10.4103/JCDE.JCDE_324_24. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Igić MA, Kostić MM, Đorđević NS, Bašić JT, Đorđević MG, Gligorijević NR, et al. Determination of gingival index and salivary proinflammatory cytokines (Interleukin 6 and Tumour Necrosis Factor α) after chemical-mechanical retraction procedure. Diagnostics (Basel) 2025;15:424. doi: 10.3390/diagnostics15040424. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Feng J, Aboyoussef H, Weiner S, Singh S, Jandinski J. The effect of gingival retraction procedures on periodontal indices and crevicular fluid cytokine levels: A pilot study. J Prosthodont. 2006;15:108–12. doi: 10.1111/j.1532-849X.2006.00083.x. [DOI] [PubMed] [Google Scholar]
- 13.Manghani K, Jain D, Gupta A, Soni M, Pandey S. Comparative evaluation of vertical and lateral gingival displacement produced by mechanical and chemical retraction systems through digital impressions using intraoral scanner: An in-vivo study. Int J Innov Sci Res Technol. 2023;8:2302–9. [Google Scholar]
- 14.Dawani M, Sathe S, Godbole SR. Comparative evaluation of clinical efficacy of two new gingival retraction systems-An in vivo research. Int J Sci Res. 2016;5:4–10. [Google Scholar]
- 15.Goutham GB, Jayanti I, Jalaluddin M, Avijeeta A, Ramanna PK, Joy J. Clinical assessment of gingival sulcus width using various gingival displacement materials. J Contemp Dent Pract. 2018;19:502–6. [PubMed] [Google Scholar]
- 16.Aldhuwayhi S. Comparative evaluation of three gingival displacement systems: An in-vivo study. Eur Rev Med Pharmacol Sci. 2023;27:8019–25. doi: 10.26355/eurrev_202309_33563. [DOI] [PubMed] [Google Scholar]
- 17.Abdelhamid AA, Mahallawi OS, Khodary NA. Assessment of lateral and vertical tissue displacement obtained by the retraction cord and diode laser: A randomized controlled clinical trial. Int J Health Sci. 2022;6:1944–59. [Google Scholar]
- 18.Solimei L, Amaroli A, Turkina A, Benedicenti S, Signore L, Signore A. Gingival retraction with 980-nm diode laser compared to double-cord technique: An in vitro study. Open Dent J. 2024;18:e18742106301712. [Google Scholar]
- 19.Bennani V, Inger M, Aarts JM. Comparison of pressure generated by cordless gingival displacement materials. J Prosthet Dent. 2014;112:163–7. doi: 10.1016/j.prosdent.2013.09.035. [DOI] [PubMed] [Google Scholar]
- 20.Qureshi SM, Anasane NS, Kakade D. Comparative evaluation of the amount of gingival displacement using three recent gingival retraction systems – In vivo study. Contemp Clin Dent. 2020;11:28–33. doi: 10.4103/ccd.ccd_311_19. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Kuhn K, Zügel D, Korbay VA, Papas T, Schnutenhaus S, Luthardt RG, et al. Gingival displacement in the vertical and horizontal dimension under the condition of mild gingivitis-A randomized clinical study. J Clin Med. 2022;11:437. doi: 10.3390/jcm11020437. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Toyman U, Tüter G, Kurtiş B, Kıvrak E, Bozkurt Ş, Yücel AA, et al. Evaluation of gingival crevicular fluid levels of tissue plasminogen activator, plasminogen activator inhibitor 2, matrix metalloproteinase-3 and interleukin 1-β in patients with different periodontal diseases. J Periodontal Res. 2015;50:44–51. doi: 10.1111/jre.12179. [DOI] [PubMed] [Google Scholar]
- 23.Phatale S, Marawar PP, Byakod G, Lagdive SB, Kalburge JV. Effect of retraction materials on gingival health: A histopathological study. J Indian Soc Periodontol. 2010;14:35–9. doi: 10.4103/0972-124X.65436. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Wang Y, Fan F, Li X, Zhou Q, He B, Huang X, et al. Influence of gingival retraction paste versus cord on periodontal health: A systematic review and meta-analysis. Quintessence Int. 2019;50:234–44. doi: 10.3290/j.qi.a41976. [DOI] [PubMed] [Google Scholar]