Skip to main content
The Breast : Official Journal of the European Society of Mastology logoLink to The Breast : Official Journal of the European Society of Mastology
. 2025 Nov 26;85:104668. doi: 10.1016/j.breast.2025.104668

Supplemental imaging modalities for breast cancer screening in women with dense breasts: A systematic review with economic considerations

Sinéad N Duggan a, Mohammad Azharuddin b, Rodolfo Hernández b, Clare Robertson c, David Cooper c, Emma McCall a, Paul Manson c, Gianni Virgili a, Mike Clarke a, Shaun Treweek c, Miriam Brazzelli d,⁎
PMCID: PMC12720037  PMID: 41343979

Abstract

Background

Underdiagnosis of breast cancer is a concern for women with dense breasts. This systematic review and meta-analysis evaluates the performance and cost-effectiveness of supplementary imaging modalities plus standard mammography, versus mammography alone, for detecting breast cancer in women with dense breasts.

Methods

We searched MEDLINE, Embase, Scopus, Cochrane Database, Web of Science, and CENTRAL for English-language studies published January 2014 to November 2024. Eligible studies compared the performance of a supplementary imaging modality with standard mammography in terms of cancer detection rate (CDR) in women with dense breasts undergoing screening. Risk of bias was assessed using QUADAS-2/QUADAS-C. Screening, data extraction, and quality assessment was conducted by one reviewer and checked by a second reviewer. PROSPERO: CRD42024550250.

Results

Out of 1740 search results, 36 studies met the inclusion criteria. Versus mammography alone, magnetic resonance imaging (MRI) identified 18·92 (95 % CI 15·41-22·43) additional cancers per 1000 screenings while digital breast tomosynthesis (DBT), automated breast ultrasound (ABUS), and handheld ultrasound (HHUS) detected 1·69 (95 % CI 0·81-2·58), 2·3 (95 % CI 1·28-3·33), and 2·57 (95 % CI 0·99-4·14) additional cancers, respectively. One study of contrast-enhanced mammography (CEM) reported a CDR comparable to MRI. Economic modelling studies revealed heterogeneous results, with MRI showing potential under specific model assumptions.

Concluding statement

Standard mammography often fails to detect cancers in women with dense breasts. Supplementary MRI provides better detection than DBT, ABUS, and HHUS. CEM seems comparable to MRI, based on limited evidence. These findings should be considered in future screening policy reviews for women with dense breasts.

Highlights

  • •

    Nearly half of the women invited for breast cancer screening have dense breasts.

  • •

    Breast density increases the risk of breast cancer and the likelihood that mammography will miss it.

  • •

    Supplementary MRI detects 19 additional cancers per 1000 screenings in those with dense breasts.

  • •

    Supplementary DBT and ultrasound detect only 2-3 additional cancers per 1000 screenings.

  • •

    Contrast-enhanced mammography detected a similar number of additional cancers as MRI, based on a single study.

1. Introduction

Breast cancer caused 670,000 deaths globally in 2022 and was the most common cancer in women in 157 countries out of 185 in that year, according to the World Health Organisation (WHO) [1]. In the UK, there were 56,822 new diagnoses annually between 2017 and 2019 [2]. The WHO Global Breast Cancer Initiative (GBCI) aims to achieve a 2.5 % annual reduction in breast cancer mortality by 2040 based on three pillars: health promotion for early detection; timely diagnosis; and comprehensive breast cancer management [1].

Whilst breast cancer screening remains one of the most effective strategies for reducing breast cancer mortality in average-risk women [3], underdiagnosis continues to be a critical concern for individuals with dense breasts, classified as categories C and D under the American College of Radiology (ACR) BI-RADS system [4]. Breast density describes the amount of fibroglandular tissue in the breast relative to the amount of fatty tissue. Because most cancers absorb X-rays to a similar extent as fibroglandular tissue, they appear as white areas on a mammogram. Consequently, dense (white) tissue can obscure or'mask’ cancers, making them more difficult to detect on mammography [3]. Women classified as BI-RADS categories C and D, encompassing nearly half of those screened [5], have an increased risk of developing breast cancer and an increased risk of missed diagnoses due to the reduced sensitivity of standard mammography in dense breasts [6]. Despite these challenges, recent advances in breast imaging technology offer promising solutions. A previous systematic review, which included studies up to March 2020, found that magnetic resonance imaging (MRI) was superior to other supplemental modalities for the detection of breast cancer in individuals with dense breasts and intermediate or average risk of breast cancer [7]. The European Society of Breast Imaging (EUSOBI) recommend that women with extremely dense breasts be offered supplemental MRI [8], but suggest that ultrasound could be performed if MRI is not available, with the caveat that the added value of supplemental ultrasound is limited. The recently concluded UK BRAID study investigated the effectiveness of an abbreviated MRI (Ab-MRI) protocol, contrast-enhanced mammography (CEM), and automated breast ultrasound (ABUS) in enhancing cancer detection in individuals with dense breasts. BRAID found that Ab-MRI and CEM identified three times as many invasive cancers as ABUS [9].

This review aimed to determine the effect of an additional imaging modality to supplement standard screening mammography, compared with mammography alone, for the detection of breast cancer in women with dense breasts. An accompanying economic review sought to assess the cost-effectiveness of supplemental imaging modalities for breast cancer screening in women with dense breasts.

2. Methods

2.1. Search strategy and selection criteria

This systematic review and meta-analysis followed the recommendations of the Cochrane Handbook for Systematic Reviews of Interventions [10] and adhered to the Preferred Reporting for Systematic Reviews (PRISMA) statement [11]. It was prospectively registered (PROSPERO registration CRD42024550250) [12] and supported by an Advisory Group, comprising content experts, methodological specialists, and patient partners. The research question was framed using the PICOS criteria: the Population of interest was women aged 40–70 undergoing screening, stratified by breast density categories; the Intervention comprised supplemental imaging modalities for women with dense breasts including MRI (full/abbreviated protocol), CEM, ultrasound (hand-held or automated), and digital breast tomosynthesis (DBT); the Comparator was standard mammography alone; the Outcomes of interest included cancer detection rate (CDR), interval cancer rate, recall rate, positive predictive values (PPV), false positive rate, sensitivity, specificity, cancer stage, and time needed for the additional imaging modality to be performed; and the relevant Setting was breast cancer population screening. We focused on Studies published in English in the last 10 years. Standard mammography, used as the comparator intervention, was defined as digital 2D mammography, consistent with current practice in the UK. The four categories of breast density described according to the ACR BI-RADS atlas are [4].

  • a.

    The breasts are almost entirely fatty

  • b.

    There are scattered areas of fibroglandular density

  • c.

    The breasts are heterogeneously dense, which may obscure small masses

  • d.

    The breasts are extremely dense, which lowers the sensitivity of mammography

An Information Specialist (PM) conducted searches across major databases (Fig. 1) focusing on full-text studies published 2014–2024 (Appendix A), with most recent searches in November 2024. Reference lists of relevant articles were screened for additional studies. Full texts of potentially relevant articles were evaluated by one reviewer (SD), with 20 % assessed by a second reviewer (CR). Disagreements were resolved through discussion or consultation with other authors (MB, ST, MC). Studies evaluating the role of additional imaging modalities in individuals with negative mammography results were deemed suitable for inclusion, and data specific to the supplemental imaging modality were extracted. While the primary population of interest was women aged 40–70 years, we did not exclude participants from other age groups if they were undergoing population-based screening.

Fig. 1.

Fig. 1

Study selection DBT, digital breast tomosynthesis; ABUS, automated breast ultrasound; HHUS, hand-held ultrasound; MRI, magnetic resonance imaging; CEM, contrast enhanced mammography. As some studies reported on more than one supplementary imaging modality, the number of reports providing information in each imaging modality (42) exceeds the number of included studies (36).

2.2. Data analysis

Data recorded from included studies encompassed study characteristics (first author, year, recruitment dates, location, centres, language, screening setting, objectives, inclusion and exclusion criteria), participant characteristics, number and experience of health professionals measuring breast density, screening frequency, and details of imaging modalities. Data extraction was performed by one reviewer (SD) and verified by a second (EMcC), with the AI Assistant feature in Adobe Acrobat used for cross-checking. Disagreements were resolved through discussion. All data were documented using a bespoke Microsoft Excel® form. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool assessed risk of bias in individual studies across four domains: patient selection, index test, reference standard, and flow and timing [13]. For comparative accuracy studies, the QUADAS-C version was used [14]. Assessments were performed by one reviewer (SD) and verified by a second reviewer (GV), using a bias guidance table developed in consultation with our Advisory Group (Appendix B). Multiple publications on the same study were combined, and potential duplicates were examined, with authors contacted as needed. Preliminary reports of subsequently published data were excluded from the final set. Findings were summarised narratively and, where appropriate, through meta-analyses. Results for each imaging modality were presented separately. For relevant outcome measures (e.g., CDR, recall rate) pooled effect estimates with corresponding 95 % CIs were calculated using a random-effects model. Meta-analysis results are presented in tabular form and illustrated graphically using forest plots [15]. The effect size shown for each study is the difference in the respective outcome between the supplemental modality and mammography-only. In Table 2 the outcome measure in the mammography group is presented with the difference between the specific modality and mammography shown in the next row of the table. To explore the influence of small study sizes, the study's Advisory Group recommended sensitivity analysis excluding studies with fewer than 500 participants. Heterogeneity between studies was quantified using the I2 statistic and examining forest plots, with thresholds indicating low (<30 %), moderate (30–60 %), or substantial (>60 %) heterogeneity [16]. Analyses were performed using Stata 18 [17].

Table 2.

Combined pooled estimates of the screening performance measures of four supplementary imaging modalities compared to digital mammography, with and without sensitivity analysis.

Parameter DBT ABUS HHUS MRI
CDR Number of studies 13 6 8 6d
CDR for mammography only, per 1000 exams 5.43 (3.75, 7.11) 4.52 (3.03, 6.02) 2.68 (1.77, 3.59) -c
Additional CDR, per 1000 exams 1.69 (0.81, 2.58) 2.3 (1.28, 3.33) 2.57 (0.99, 4.14) 18.92 (15.41, 22.43)
Sensitivity analysisa - - – 17.23 (14.38, 20.08)
Recall rate Number of studies 11 5 5 3
Recall rate for mammography only, % 12.56 (8.96,16.15) 5.97 (−0.32,12.27) 4.25 (1.37,7.12) -c
Difference in recall rate, % −2.19 (−4.03, −0.34) 5.49 (0.85, 10.13) 6.65 (1.02, 12.27) 7.98 (4.62, 11.34)
Sensitivity analysisb −1.94 (-3.83, -0.05) - – 9.55 (8.85,10.24)
Biopsy rate Number of studies 3 5 2 3
Biopsy rate for mammography only, % 2.07 (1.57,2.57) 1.83 (0.30,3.36) – –
Difference in biopsy rate, % 0.32 (0.15, 1.32) 1.62 (0.54, 2.70) n/a n/a

CDR, cancer detection rate; DBT, digital breast tomosynthesis; ABUS, automated breast ultrasound; HHUS, hand-held ultrasound; MRI, magnetic resonance imaging. Data in parentheses are 95 % confidence intervals.

a

Kaiser and Chen removed for MRI sensitivity analysis [26,49].

b

Upadhyay removed for DBT sensitivity analysis [36].

c

These values are zero because the comparator arm in the MRI studies is ‘negative mammography’.

d

Veenhuizen was not included in the meta-analysis as this study reported the incident screening round [30]; Chen reports both abbreviated and full protocol MRI, so there are six comparisons in five studies represented in the MRI meta-analysis [49].

2.3. Patient and public involvement (PPI), and language and inclusivity statement

PPI partners with lived experience of mammography and breast cancer contributed to our Advisory Group alongside content and methodological experts. They actively participated in all project meetings and provided input across all review stages. While the UK breast screening programme primarily targets women, this review intentionally uses both gender-specific and gender-neutral language to acknowledge all individuals who access breast screening services.

Role of funding source

This review was funded by the National Institute for Health and Care Research (NIHR) Evidence Synthesis Programme (project number NIHR164221) and commissioned by the United Kingdom National Screening Committee (UK NSC). The UK NSC provides screening recommendations to the UK government, based on a range of criteria, including a consistent approach to the identification and synthesis of relevant literature. The UK NSC and NIHR have recently agreed on a formal collaboration to ensure the quality of evidence reports. The NIHR Evidence Synthesis Programme had no role in the collection, analysis, or interpretation of the data; in the writing of the report; or in the decision to submit the article for publication. The UK NSC, as commissioners of the work, participated in the Advisory Group and provided expert input on study design, data interpretation, and the current screening pathway. However, they had no role in writing the manuscript, formulating the conclusions, or deciding to submit it for publication.

2.4. Economic evaluation

A review of economic evaluations assessing the costs and consequences of supplemental imaging modalities for breast cancer screening in women with dense breasts was conducted in parallel and is summarised briefly in this manuscript. The search strategy and PRISMA flowchart for the economic review are in Appendices C and D.

3. Results

A total of 1740 citations were identified from the literature searches, with 178 reports selected for full-text screening. Forty-one relevant studies were identified, including two articles from additional sources (Fig. 1), one of which was accessed in its prepublication version and subsequently published [9]. After removing five duplicates, 36 studies were included, ten of which were published between 2023 and 2025 [9,[18], [19], [20], [21], [22], [23], [24], [25], [26]]. Publications excluded after review of full text are listed in Appendix E. The studies were geographically distributed: 16 in Europe [9,22,24,[26], [27], [28], [29], [30], [31], [32], [33], [34], [35], [36], [37], [38]], 10 in North America [[39], [40], [41], [42], [43], [44], [45], [46], [47], [48]], and 10 in Asia [[18], [19], [20], [21],23,25,[49], [50], [51], [52]]. Digital breast tomosynthesis (DBT) was the most frequently assessed modality (18 studies) [22,24,27,33,34,[36], [37], [38], [39], [40], [41], [42], [43], [44], [45],47,48,50], followed by handheld ultrasound (HHUS, nine studies) [[19], [20], [21],23,25,28,37,51,52], ABUS (six studies) [9,18,20,29,32,46], MRI (six studies) [9,26,30,31,35,49], whole breast sonography (WBS, one study) [45], and CEM (one study) [9]. For all MRI studies, only participants with a negative mammography received MRI. Full-protocol MRI was used in five studies [26,30,31,35,49], while an Ab-MRI was adopted in two studies [9,49] (one study compared both protocols) [49]. Table 1 illustrates the characteristics of the included studies. Reporting of equality, diversity and inclusion (EDI) characteristics was generally poor.

Table 1.

Reported characteristics of included studies for each supplementary imaging modality plus mammography in women with dense breasts.

Study name
Author, year (country)
Supplementary screening modality/comparator imaging
(interval between tests)
Design (number of centres) Study years Number with dense breasts in study arm/number with dense breasts in DM only arm a Brief population description
Ageb
Screening programme interval Reference standard
DBT
CBTST
Pulido-Carmona, 2024 [22] (Spain)c
DBT/DM
(Interval: simultaneous)
Retrospective study (1) 2015 Jan to 2016 Dec 4207/8950 People 50-69y resident in Cordoba participating in breast cancer screening
Age NR
Biennial Linkage with multiple registries and database of centre's Breast Unit
MBTST
Olinder, 2023 [24] (Sweden)
DBT/DM
(Interval: simultaneous -acquired at one screening occasion)
Prospective screening trial (1) 2010 Jan to 2015 Feb 6645/6, 645 (participants underwent both imaging modalities) Random sample of people 40-74y selected from screening registry in Malmö, Sweden
Age NR (reported for highest density quintiles only)
NR NR
RETomo
Pattacini, 2022 [34] (Italy)
DBT/DM
(Interval: simultaneous)
RCT (3) 2014 Mar to 2017 Aug 5970/5978 People aged 45–69y attending screening in one of three clinics
Age NR
45–49 y annual
50–74 y biennial
All recruited people followed up in screening programme and Cancer Registry
Evaluation of surgical specimen considered final diagnosis of lesion
Durand, 2021 [42] (USA) DBT/DM
(Interval: NR)
Retrospective study (10) DBT start dates between 2011 Apr and 2012 May to 2013 Jun
DM start dates NR
86,571/95,914 Screening examinations from 10 academic and community practices
Age:
40-49y: 113,950 (29.9 %)
50-69y: 209,753 (55.1 %)
≥70y: 45,019 (11.8 %)
Annual Linkage to site and state cancer registries
Pang, 2021 [47] (Canada) DBT/DM
(Interval: simultaneous; combined DBT and DM)
Observational (2) 2015 to 2018 58,281/67,489 People ≥40y who underwent screening at two large volume multisite radiology groups in Alberta, Canada
Age NR
Biennial Linkage to Alberta Cancer Registry
Ban, 2021 [50] (Japan) DBT/DM
(Interval: NR)
Prospective trial (1) 2017 May to 2019 Mar 1739/4226 People attending population-based screening in Japan who also had opportunistic DBT screening (workplace/private) and were >30y
Age: NR
Biennial NR
Oslo Tomosynthesis Screening Trial
Osteras, 2019 [27] (Norway)
DBT/DM
(Interval: simultaneous [combined DBT and DM])
Prospective clinical trial (1) 2010 Nov to 2012 Dec 8466/8466 (participants underwent both imaging modalities) People aged 50-69y attending population-based screening program, BreastScreen Norway
Age:
50–54y: 3158
55–59y: 2390
60–64y: 1574
65–69y: 1624
Biennial 2 years of follow-up to assess interval cancers
Stepanek, 2019 [48] (USA) DBT/DM
(Interval: simultaneous; combined DBT and DM)
Retrospective review (1) DM: 2010 Sep to 2011 Aug
DBT/DM: 2014 Jan to 2015 Jun
4389/4895 Screening programme with DM; DBT made available at an additional charge
Age NR
Annual Category 3 lesions followed for minimum 2 y or cross-referenced with the state tumour registry
Negative findings BIRADS 1/2 resumed annual screenings
MBTST
Johnson, 2019 [38] (Sweden)
DBT/DM
(Interval: simultaneous -one screening occasion)
Prospective, population-based screening trial (NR) 2010 Jan to 2015 Feb 6202/6202 (participants underwent both imaging modalities) Random sample of people from screening registry in the city of Malmö, Sweden
Age NR
NR Pathologic assessment of surgical specimens
Linkage with Cancer Registry
Upadhyay, 2018 [36] (UK) DBT/DM
(Interval: simultaneous)
Retrospective reader study (1) 2013 Jan to 2013 Dec 423/423 (participants underwent both imaging modalities) People aged 46–53 were recruited from the prevalent screening round of the NHS Breast Screening Programme
Age NR
Triennial Recalls: Assessment within 3 weeks (further imaging, biopsy as appropriate)
Rose, 2017 [44] (USA) DBT/DM
(Interval: Simultaneous -combined DBT/DM for all or part of the analysis period)
Retrospective review of screening mammography audit data (31) 2015 Jan to 2015 Dec 10,360/21,929 Community-based screening programme for people <50y
Age NR
NR Data validated by auditing patient outcomes, imaging reports, and pathology results for biopsy and surgical specimens
Freer, 2017 [41] (USA) DBT/DM
(Interval: simultaneous)
Retrospective study with institutional databases (NR) 2013 Oct to 2014 Dec (cohort 3 end date 2015 Dec) 521/8302 People who presented for screening MM to any screening facility of their academic medical centre
Cohort 2: Under 40: 1.7 %; 40–49: 27.5 %; 50–59: 34.2 %; 60–69: 25.3 %; 70–74: 6.9 %; Over 74: 4.4 %
Cohort 3: Under 40: 1.4 %; 40–49: 26.0 %; 50–59: 31.7 %; 60–69: 25.5 %; 70–74: 7.8 %; Over 74: 7.6 %
NR NR
STORM-2
Bernardi, 2016 [33] (Italy)
DBT/DM
(Interval: simultaneous)
Prospective population-based screening study (1) 2013 May to 2015 May 2592/2592 (participants underwent both imaging modalities) People >49y attending population-based screening programme
Age NR
Biennial Biopsy
Recalled patients: completed assessment outcome, inclusive of work-up imaging (with or without biopsy)
Starikov, 2016 [45] (USA) DBT/MM
(Interval: same day)
Retrospective observational case–control study (1) 2013 Jan to 2013 Dec 1875/7117 People presenting for screening mammography
Age: Majority of patients >40y
Annual List of biopsy proven screen-detected breast cancers
PROSPR
Conant, 2016 [43] (USA)
DBT/DM
(Interval NR)
Retrospective analysis of prospective cohort data (3) 2011 to 2014 21,133/44,303 People 40-74y with no known prior breast cancer
Age:
40–49 years: 37,155 (26.0 %) for DM, 18,668 (33.3 %) for DBT
50–59 years: 51,096 (35.8 %) for DM, 20,839 (36.4 %) for DBT
60–74 years: 54,632 (38.2 %) for DM, 16,941 (30.3 %) for DBT
NR Biopsy information from electronic health records and pathology databases
-≥ 1 year of imaging follow-up
Cancer data from local institutional tumour registries, state registries,
and one statewide surveillance system
ASTOUND
Tagliofico, 2016 [37] (Italy)
DBT/negative DM
(Interval: simultaneous
Prospective multicentre study (5) 2012 Dec to 2015 Mar 3231/3231 (participants underwent both imaging modalities) Asymptomatic people with negative MM aged 38 years or older with dense breasts
Age: median (IQR) age 51 y (44–78) (of those invited to study; 64 declined to participate))
NR Biopsy
Recalled subjects: work-up imaging with or without core-needle biopsy
MacDonald, 2016 [40] (USA) DBT/DM
(Interval NR)
Retrospective analysis (1) 2010 Sep to 2011 Aug 3611/3489 People underdoing screening mammography at the University of Pennsylvania
Mean (SD) age:
DM cohort: 56.9 (11.0)
Unclear, likely annual Biopsy
Pennsylvania State Cancer Registry queried to determine interval cancer rate
MacDonald, 2015 [39] (USA) DBT/DM
(Interval NR)
Retrospective analysis of a natural outcomes experiment (1) 2010 Sept to 2013 Feb 632/405 People underdoing screening mammography at the University of Pennsylvania
Mean (SD) age:
DM cohort: 49.2y (10.1)
DBT cohort: 48.9y (10.6)
NR Biopsy or surgical outcomes tracked within 180 days of screening
recall
Min 12 months of follow-up data available for all patients in both cohorts
Linkage to Pennsylvania State Cancer Registry
ABUS
BRAID, Gilbert, 2024 [9] (UK) ABUS/negative screening MM
(Interval median days [IQR]: 111 [77–150])
RCT (10) 2019 Sept to 2024 Mar 2141/6306 MM-negative people attending UK population breast screening at 10 centres
Median (IQR) age:
56 (52–61)
Triennial Recall cases: further imaging and biopsy if lesion was confirmed
Where doubt about lesion or not: repeat CEM or MRI/short term follow up offered
Kwon, 2023 [18] (South Korea) ABUS/DM
(Mean interval 4 days; range 0–90 days)
Retrospective analysis involving database search (1) 2018 Jan to 2019 Dec 2155/2155 (participants underwent both imaging modalities) Database of consecutive asymptomatic people breast cancer screening
Age profile:
<50y 40 %
>50y 60 %
NR Histopathologic results from surgical excision, US-guided core biopsy or vacuum-assisted biopsy, stereotactic biopsy, or stability on follow-up imaging
Ren, 2023 [20] (China) ABUS/DM
(Interval NR, but people with an odd number at end of ID receive ABUS first while those with even number attend DM first – suggesting immediate)
Multicentre, population-based study (6) 2018 Feb to 2022 Aug Total group 10,884 Asymptomatic people attending breast cancer screening in China
Median (IQR) age:
51.54 (4.61)
NR Biopsy or 1-year follow-up
Gatta, 2021 [32] (Italy) ABUS/FFDM
(Interval NR)
Prospective observational study (1) 2017 Jun to 2019 Feb 1165/1165 People with dense breasts attending health screening centre
Age:
40-50y 68 %
50-60y 25 %
60-70y 7 %
Annual (for dense breasts) No signs of malignancy: dense breast annual checkup
Suspected malignancy:
Biopsy
Wilczek, 2016 [29] (Sweden) ABUS/DM
(Interval: immediate)
Prospective evaluation of a breast screening programme (1) 2020 Nov to 2012 Feb 1668/1668 Asymptomatic people with dense breasts who had been invited for breast cancer service screening mammography
Age:
40-49y: 59.7 %
50-59y: 26.7 %
60-69y: 13.5 %
People aged 40-49y every 18 months Suspicious findings (DM or ABUS): recalled and subjected to mammography work–up with complementary views and HHUS
dCode 1–2: invited to the next screening after appropriate interval
dCode 3–5: biopsy
Somolnsight
Brem, 2015 [46] (USA)
ABUS/DM
(Interval: Immediate)
Observational, multicentre study (10) 2009 to 2019 15,318/15,318 People aged >25 years with dense breast tissue
Mean (SD) age 53.3 (10)
Annual Normal, benign, or probably benign: followed
up for 12 months
Developed breast symptoms during the follow-up period:
clinically indicated evaluation
HHUS
Ha, 2024 [25] (South Korea) HHUS/DM
(Interval NR, but some on same day)
Retrospective study (1) 2017 Jan to 2018 Dec 5707/5707 Consecutive asymptomatic people (≥40 years) with dense breasts who underwent routine screening DM and supplemental US
Age:
Mean (SD) age 52.4 (7.9) y
Annual Histologic examination and 1-year follow-up data
Positive cases: short-interval follow-up (6 months) and additional DM or biopsy recommended
Lee, 2024 [21] (South Korea) US/DM
(Interval: within 1 month)
Retrospective study (1) 2017 Jan to 2017 Dec 1325/1325 Patients with dense breasts who underwent both screening DM and screening US
Mean 53 years, median 53 years
At least biennial Cancer diagnosis: pathological evaluation
Benign diagnoses: MM/US follow-up documenting at least 24 months of imaging stability
J-Start
Nakamura, 2024 [19] (Japan)
HHUS/DM
(Interval NR)
Retrospective analysis of breast cancer screening data (NR) 2018 to 2021 6271/11,765 People in their 40s undergoing breast cancer screening
Age: NR for people with dense breasts
NR Positive cases referred to specialised institution
Ren, 2023 [20] (China) HHUS/negative DM
(Interval NR, but people with an odd number at end of ID receive ABUS first while those with even number attend DM first – suggesting immediately)
Multicentre, population-based study (6) 2018 Feb to 2022 Aug 10,884/10,884 (participants underwent both imaging modalities) Asymptomatic people attending breast cancer screening in China with negative DM
Median (IQR) age:
51.54 (4.61)
NR Biopsy or 1-year follow-up
Rani, 2023 [23] (India) US/DM
(Interval: ‘mammography followed by ultrasound’)
Prospective, observational study (1) NR 125/125 (participants underwent both imaging modalities) Asymptomatic people coming for breast cancer screening
Age >40y
Annual health screening - not clear if this was annual breast screening Biopsy
BIRADS 3 lesions subjected to short interval follow up and few lesions had surgical excision
J-Start
Harada-Shoji, 2021 [52] (Japan)
HHUS/DM
(Interval NR)
Secondary analysis of a randomised clinical trial (42) 2007 Jul to 2011 Mar 5797/5593 Asymptomatic people aged 40–49 years who were enrolled in J-START
Mean (SD) age:
44.8 (2.8)
NR Linkage with hospital discharge records and cancer registry databases used to identify breast cancer diagnosis information
Buchberger, 2018 [28] (Austria) HHUS/DM
(Interval: at same visit)
Observational data from a population-based screening program (22) 2008 Jun to 2010 May 31,918/31,918 (participants underwent both imaging modalities) Participants identified through the Tyrolean breast cancer screening program, included all people aged 40–69 who lived in Tyrol and were covered by compulsory social insurance
Age NR
Aged 40–59: annual
Aged 60–69: biennial
Linking the screening dataset to all breast cancer cases collected in Cancer Registry of Tyrol
ASTOUND
Tagliafico, 2016 [37] (Italy)
HHUS/negative DM
(Interval unclear, but likely immediate)
Prospective multicentre study (5) 2012 Dec to 2015 Mar 3231/3231 (participants underwent both imaging modalities) Asymptomatic people with negative MM aged 38 years or older with dense breasts
Age:
Median (IQR) 51 (44–78)
NR Biopsy
Recalled subjects: work-up imaging with or without core-needle biopsy
Chang, 2015 [51] (South Korea) HHUS/negative DM
(Interval unclear: ‘Scheduling simultaneously performed’)
Retrospective review of a database (1) 2008 Jan to 2008 Dec 990/990 (participants underwent both imaging modalities) MM-negative people attending health screening centre
62 % of all participants <50y
NR Most severe biopsy results within 1 year of screening and clinical follow-up at 1 year or both
MRI
MA-DETECT
Kaiser, 2024 [26] (Germany)
Fp-MRI/negative screening DM
(Interval: not to exceed 2 months)
Prospective screening study, preliminary report (1) 2021 Jun to 2023 Jun 200/200 (participants underwent both imaging modalities) MM-negative people attending national German breast cancer screening programme; report for first 200 people
Age NR
NR BI-RADS 3: MRI follow-up after 6 months
BI-RADS 4 and 5: Biopsy (as per EUSOBI recommendations)
BRAID
Gilbert, 2024 [9] (UK)
Ab-MRI/negative screening DM
(Interval median days [IQR]: 143 [98–183])
RCT (10) 2019 Sept to 2024 Mar 2130/6306 (participants underwent both imaging modalities) MM-negative people attending UK population breast screening at 10 centres
Median (IQR) age:
56 (52–61)
Triennial Recall cases: further imaging and biopsy if lesion was confirmed
Ab-MRI group: Fp-MRI conducted when no lesion found on assessment
Where doubt about lesion or not: repeat CEM or MRI/short term follow up offered
DENSE (2nd Round) Veenhuizen, 2021 [30] (Netherlands) Fp-MRI/negative screening DM
(Median [IQR] interval 8 [3–13] weeks)
Prospective, multicentre trial embedded within the screening programme (NR) 2011 Dec to 2016 Jan 3436/3436 (participants underwent both imaging modalities) MM-negative people attending Dutch population based biennial screening programme for second MRI (all extremely dense breasts)
Median (IQR) age:
54 (51–59)
Biennial MRI screening and diagnostic work-up (biopsy and histopathological examination)
DENSE (1st Round)
Bakker, 2019 [35] (Netherlands)
FpMRI/negative screening DM
(Median [IQR] interval: 10 [I8-14] weeks)
Multicentre RCT (8) 2011 Dec to 2015 Nov 4783/4783 (participants underwent both imaging modalities) MM-negative people attending Dutch National population-based biennial screening for first round MRI (all extremely dense breasts)
Median (IQR) age:
DM only: 54 (51–61)
MRI: 55 (51–61)
Biennial Linkage with the Netherlands
Cancer Registry
MRI invitation group: 6-month repeat screening
Kuhl, 2017 [31] (Germany) Fp-MRI/negative screening DM
(Median interval: 5 days; range 0–28 days)
Prospective observational study (2) 2005 Jan to 2013 Dec 1282/1282 (participants underwent both modalities) MM-negative women of average breast cancer risk invited to supplemental screening at one of two academic centres.
Some women also negative on ultrasound.
First round data presented.
Age NR
NR Negative screens followed with MM with or without US for at least another 24 months
BI-RADS 3 underwent short-term follow-up and returned to regular screening
Suspicious findings underwent biopsy with MRI screening
High risk lesion: biopsy/surgical excision
Chen, 2017 [49] (China) Fp-MRI/negative DM
Ab-MRI/negative DM
NR (1) 2013 Jan to 2015 Mar 478/478 (participants underwent MM, FP-MRI and Ab-MRI) MM-negative women with dense breasts invited to supplemental screening at a single institution in China
Mean age: 49.3
NR Biopsy and surgical pathology
OTHER imaging modalities
BRAID Gilbert, 2024 [9] (UK) CEM/DM
(Interval median days [IQR]: 134 [91–173])
RCT (10) 2019 Sept to 2024 Mar 2035/6303 MM-negative people attending UK population breast screening at 10 centres
Median (IQR) age:
56 (52–61)
Triennial Recall cases: further imaging and biopsy if lesion confirmed
Where doubt about lesion or not: repeat CEM or MRI/short term follow up offered
Starikov, 2016 [45] (USA) WBS/DM
One third of WBS performed with ABUS machine, two thirds performed with HHUS
(Interval: same day)
Retrospective observational case–control study (1) 2013 Jan to 2013 Dec 1397/7117 People presenting for screening mammography
Majority of patients >40y
Annual List of biopsy proven screen-detected breast cancers
Starikov, 2016 [45] (USA) WBS plus DBT/DM
One third of WBS performed with ABUS machine, two thirds performed with HHUS
(Interval: same day)
Retrospective observational case–control study (1) 2013 Jan to 2013 Dec 526/7117 People presenting for screening mammography
Majority of patients >40y
Annual List of biopsy proven screen-detected breast cancers

^NR, but obtained via author correspondence

a

Number of people with supplementary modality plus DM study arm, and in the DM only arm (according to BIRADS categories D and C corresponding to heterogeneously and extremely dense breasts, respectively).

b

Age shown if reported specifically for people with dense breasts; presented as mean, median, proportions as reported.

c

Study was eligible for inclusion however as the intervention (supplemental modality) included synthesis mammography as well as digital breast tomosynthesis, study was not amenable to meta-analysis.

d

Five step coding: (1) normal, (2) benign, (3) probably benign, (4) highly suspicious of malignancy, (5) malignant.

Most studies had low risk of bias in the domain of patient selection; however, five studies (14 %) were rated as high risk due to opportunistic selection [19,23,41,48,50] and unclear reporting [23]. Applicability concerns were identified in 15 studies (41 %), mainly due to age profiles that did not align well with the UK screening programme [18,19,36,44,46,49,51,52], or inclusion of women with extremely dense breasts only [30,35]. A further study was flagged for applicability concerns as approximately 65 % of MRI participants had a negative ultrasound as well as a negative mammography [31], and an unspecified number of individuals had negative ultrasounds and were ineligible for the MRI study. Therefore, the comparator arm had an advantage over the mammography-only arm, likely leading to an underestimation of MRI's cancer detection performance [31]. Seventeen studies (47.2 %) were at low risk based on randomised design or adequate control for confounders [9,18,20,23,24,[26], [27], [28],30,[33], [34], [35], [36], [37], [38],49,51], while six studies (17 %) exhibited high risk due to non-randomised design [19,22,31,41,48,50]. Regarding reference standards, 24 studies (67 %) employed multiple verification methods [9,18,[20], [21], [22],[25], [26], [27], [28], [29], [30],32,[34], [35], [36], [37], [38], [39], [40],42,43,48,51,52]; however, ten studies (28 %) had high risk due to inadequate follow-up of participants with negative results [23,24,33,41,[44], [45], [46], [47],49,50]. Flow and timing risks were rated as unclear in 47 % [19,23,24,27,28,33,36,37,[40], [41], [42], [43], [44], [45],47,50,52] and high in 22 % [18,20,21,25,31,48,49] of studies due to inadequate reporting or missing data related to follow-up procedures (Appendix K).

RCT, randomised controlled trial; CBTST, Córdoba Breast Tomosynthesis Screening Trial; MBTST, Malmö Breast Tomosynthesis Screening Trial; RETomo, Reggio Emilia Tomosynthesis; PROSPR, Population-based research optimizing screening through personalized regimens; STORM, Screening with Tomosynthesis Or standard Mammograph; ASTOUND, Adjunct Screening With Tomosynthesis or Ultrasound in People With Mammography-Negative Dense Breasts; NR, not reported; DM, digital mammography; DBT, digital breast tomosynthesis; MM, mammography; BIRADS, breast imaging reporting and data system; IQR, inter-quartile range; SD, standard deviation; MRI, magnetic resonance imaging; HHUS, hand-held ultrasound; ABUS, automated breast ultrasound; BRAID, Breast Screening; Risk Adaptive Imaging for Density; CEM contrast enhanced mammography; RCT, randomised controlled trial; Ab-MRI, abbreviated MRI; Fp-MRI, full protocol MRI; DENSE, Dense Tissue and Early Breast Neoplasm Screening; EUSOBI, European Society of Breast Imaging; WBS, whole breast sonography; Meta-analyses were conducted for four supplemental imaging modalities - DBT, ABUS, HHUS, and MRI - compared with standard mammography (Table 2, Fig. 2). All supplementary modalities demonstrated higher CDR than mammography alone. In the meta-analysis, MRI showed the greatest benefit with a pooled effect size of 18·92 (95 % CI 15·41 to 22·43) additional cancers detected per 1000 screenings (Fig. 2 (i) D). A sensitivity analysis excluding small studies (<500 participants) [26,49] yielded a CDR difference for MRI of 17·23 (95 % CI 14·38 to 20·08). Screening-round analysis by Veenhuizen et al. showed a lower CDR for incident MRI screening (5·8 per 1000; 95 % CI 3·8 to 9)30 compared to the prevalent screening round (16·5 per 1,000, 95 % CI 12·92 to 20·12) [35]. The BRAID trial reported a CDR of 19·2 (95 % CI 13·7 to 26·1) for CEM, comparable to MRI [9]. Meta-analyses of DBT, ABUS, and HHUS showed smaller but statistically significant increases in CDR: 1·69 (95 % CI 0·81 to 2·58) (Fig. 2 (i) A), 2·30 (95 % CI 1·28 to 3·33) (Fig. 2 (i) B), and 2·57 (95 % CI 0·99 to 4·14) (Fig. 2 (i) C), respectively. However, substantial heterogeneity was observed across the DBT and HHUS studies (I2 >60 %).

Fig. 2.

Fig. 2

Forest plots showing effect size of supplementary imaging modalities for (i) Cancer Detection Rate, (ii) Recall Rate, and (iii) Biopsy Rate (i) Effect size of supplementary A) DBT B) ABUS C) HHUS and D) MRI versus DM alone for Cancer Detection Rate (ii) Effect size of supplementary A) DBT B) ABUS C) HHUS and D) MRI versus DM alone for % Recall Rate (reported definition of recall rate in parentheses) (iii) Effect size of supplementary A) DBT and B) ABUS versus DM alone for % Biopsy Rate.

Regarding recall rates, substantial heterogeneity was observed across all supplementary modalities (I2 >90 %) (Fig. 2 (ii) A-D) DBT showed a pooled reduction of −2·19 (95 % CI -4·03 to 0·34) (Fig. 2 (ii) A) in recall rates compared with mammography alone, whereas ABUS, HHUS, and MRI (Fig. 2 (ii) B-D) demonstrated increases of 5·49 % (95 % CI 0·85 to 10·13), 6·65 % (95 % CI 1·02 to 12·27), and 7·98 % (95 % CI 4·62 to 11·34), respectively. The recall rate for CEM (9·7 %, 95 % CI 8·4 to 11) was comparable with that of MRI. Notably, definitions of recall varied across studies, contributing to the inconsistency of findings.

Regarding biopsy rates, meta-analyses were conducted only for DBT and ABUS. DBT showed no significant difference in biopsy rates versus mammography alone (pooled effect size: 0·32, 95 % CI -0·12 to 0·76) (Fig. 2 (iii) A) [24,43,44]. ABUS showed a higher rate (1·62, 95 % CI 0·54 to 2·70) with substantial heterogeneity (Fig. 2 (iii) B) [9,18,29,32,46]. For MRI, biopsy rates were 4·93 % (95 % CI 3·98 to 5·88) in the BRAID study [9]. Biopsy rates were 6·27 % (95 % CI 5·58 to 6·96) and 2·44 % (95 % CI 1·93 to 2·96) in the first [35] and second rounds [30] of the DENSE study, respectively.

Sensitivity, specificity, positive predictive value 1(number of cancers diagnosed per number of positive screens, PPV1), and biopsy proven predictive value (PPV3) were infrequently reported (Appendices F-I). Sensitivity was generally higher in supplementary imaging, except in one study where ABUS had lower sensitivity (63·6 %) than mammography-only (94·6 %) [18]. One MRI study showed high sensitivity (95·2 % [95 % CI 88·1 to 98·7]) for MRI following negative mammography [35]. A second MRI study reported sensitivity of 100 % and 88.3 % for full-protocol and abbreviated protocol MRI, respectively [49]. In the DENSE studies, MRI false positive rate declined from 79·835 to 26·330 per 1000 screenings between first and second screening rounds.

One DBT study reported interval cancer rates of 0·95 % in the supplementary arm versus 3·17 % with mammography-only [22], while the RETomo trial reported rates of 0·23 % in the supplementary group versus 0·25 % in the mammography-only group [34]. One study showed lower rates with supplemental HHUS [52] while another reported ‘no interval cancers’ in the HHUS/negative mammography group [51]. The DENSE trial identified four interval cancers among participants who underwent MRI and 16 among those who declined MRI, compared to 161 in the mammography group [35]. No interval cancers occurred during a two-year follow-up in the MRI study by Kuhl et al. (Appendices F-I) [31].

Cancer pathology was reported in 13 studies across all modalities. Focusing on MRI as the best-performing modality, four studies reported the detection of 4,26 14,30 32,9 and 6435 invasive cancers, respectively, in participants who'd had negative mammography. The median (IQR) tumour size detected by supplementary MRI was 1.0 cm (0.8–1.5)9 and 0.7 cm (0.6–1.0)30 in two studies reporting these data. A single study assessing CEM reported that 32 of 39 detected cancers were invasive, a similar performance to MRI [9].

MRI acceptance rates varied across studies and were low in some cases. Bakker et al. reported that only 59 % of invitees accepted the invitation for MRI screening [35]. In the preliminary report by Kaiser et al., 80 of 200 women (40 %) were screened but not scheduled for MRI for various reasons [26]. In the BRAID study, 188 of 2318 (8 %) women withdrew from the MRI arm due to factors such as relocation, inability to attend, personal issues, and contrast contraindications [9]. Two MRI studies did not report declinations or failures to attend MRI screening [31,49].

Nine studies reported the time taken to perform and/or interpret supplementary imaging, of which three studies reported on MRI. One study reported that supplementary full-protocol MRI took just under 10min [26]. Similarly, a second full protocol MRI study reported a performance time of less than 10min [31]. Chen et al. reported a mean (SD) interpretation time for full and abbreviated MRI protocols of 192 (44) seconds and 42 (18) seconds, respectively [49].

Regarding the safety of supplemental modalities, among the studies on MRI, Kuhl et al., [31] Chen et al., [49] and Kaiser et al. [26] did not report on adverse events or safety. In the DENSE trial, Veenhuizen et al. reported one vasovagal reaction requiring emergency department attendance, classified as a serious adverse event occurring during or immediately after the MRI examination [30]. Two additional events were associated with contrast agent extravasation. Bakker et al. reported an incidence of 0.1 % for both adverse events and serious adverse events occurring during or immediately after MRI examination [35]. In the study published by Gilbert et al. one case of extravasation was reported (0.5 events per 1000 examinations), with no other adverse events noted [9]. In contrast, Gilbert et al. observed 24 iodinated contrast reactions in the CEM group comprising 17 minor, six moderate, and one severe reaction along with three cases of extravasation [9]. The authors did not report whether the observed difference in adverse reactions to intravenous contrast media between MRI (0.5 in total per 1000 examinations) and CEM (13.3 in total per 1000 examinations) was statistically significant.

The parallel systematic review of economic models assessing enhanced mammographic screening for individuals with dense breasts identified 12 modelling studies [[53], [54], [55], [56], [57], [58], [59], [60], [61], [62], [63], [64]]. These included ten cost-utility analyses (CUA) [[53], [54], [55], [56],[59], [60], [61], [62], [63], [64]], and two cost-effectiveness analyses (CEA) [57,58], primarily from the US, employing diverse decision-analytic approaches such as microsimulation, discrete event simulation (DES), and hybrid Markov or decision tree models (Appendix M). MRI was the most commonly assessed supplemental modality. Five of seven MRI modelling studies found it potentially cost-effective [53,56,57,59,62], particularly in risk-stratified strategies or as a replacement for mammography in women with extremely dense breasts (Appendix P). Some studies conducted in the Netherlands supported MRI every four years for women with BI-RADS D density [56], and Ab-MRI biennially for women aged 50–65 with BI-RADS C or D density [57], both reporting acceptable incremental cost-effectiveness ratio (ICERs) under the pre-specified €20,000 per life-year gained (LYG) threshold. In contrast, UK [64] and Canadian [61] studies found minimal QALY gains and high ICERs, deeming MRI or Ab-MRI not cost-effective. Cost-effectiveness of MRI was highly sensitive to assumptions about mammography sensitivity, age-related density decline, and utility weights. Some economic models reported Ab-MRI to be cost-effective when added after a negative result for annual mammography, but these results were often driven by optimistic assumptions of near-perfect utility for healthy or treated individuals, potentially inflating QALY gains. CEM, though less frequently evaluated, yielded mixed results. One UK-based study suggested that a screening strategy combining mammography and CEM could offer a more cost-effective approach than MRI-based screening strategies (Appendix Q) [64]. Another study found CEM less favourable compared to Ab-MRI or ABUS (Appendix Q) [53]. Quality assessment using the Philips checklist showed variable reporting standards, with scores ranging from 38 % to 89 % (Appendix O). Only four studies calibrated their models against independent data [[53], [54], [55], [56]], and many relied on pre-existing frameworks (e.g., MISCAN, CISNET, SiMRiSc, Appendix M). Utility assumptions strongly influenced ICERs; perfect or near-perfect values (1·059,62 or 0·9959) for individuals without cancer or post-treatment, biased the results toward cost-effectiveness. Characteristics of economic analyses (Appendix O), MRI summary results (Appendix P) and summary results of various supplemental modalities used alongside MRI and CEM (Appendix Q) are provided in the supplementary file.

4. Discussion

Standard mammography often fails to detect breast cancer in individuals with dense breasts; notwithstanding, the accuracy of screening interpretation is also influenced by factors such as the technical quality of the mammogram and the radiologist's level of experience. In our review, DBT detected 1-2 additional cancers per 1000 screenings, while both ABUS and HHUS identified 2-3 additional cancers per 1000 screenings compared to mammography alone. MRI emerged as a superior imaging modality, detecting nearly 19 additional cancers per 1000 screenings. Even after excluding smaller studies, MRI consistently identified more than 17 additional cancers per 1000 screenings. In a single study, CEM detected 19 additional cancers per 1000 screenings, suggesting its performance may be comparable to MRI in average-risk individuals with dense breasts [9]. This highlights CEM's promise as a supplementary tool, particularly because it has traditionally been used in higher-risk populations.

While CDR is a key outcome measure, breast screening programmes also commonly report the ‘referral to assessment rate’ (RAR) – often referred to as recall rate – to mitigate the psychological burden and unnecessary investigations associated with false-positive findings. UK target recall rates are set at under 7 % for prevalent screenings and below 5 % for incident screenings [65]. Although elevated recall rates are undesirable, they may correlate with lower interval cancer rates [66], suggesting a minimal threshold may be important to optimise screening benefits. Our meta-analyses showed recall rates were broadly similar for ABUS, HHUS, and MRI, despite MRI meta-analysis having a much higher CDR, which typically aligns with increased recall rate. Studies of prevalent screenings [9,31,35] reported higher recall rates than the study by Veenhuizen [30] on incident screenings, indicating that both CDR and recall rate may decline over time. Disparities in how ‘recall’ was defined likely contributed to the substantial heterogeneity and wide confidence intervals across studies. Inclusion of BI-RADS 0 in recall criteria in several studies complicated direct comparisons. In contrast, MRI studies used more consistent definitions, enhancing the reliability of the meta-analysis results.

Interval cancer rates were rarely reported, but two MRI studies provided relevant data [31,35]. One study found an interval cancer rate of 2·5 per 1000 screenings in the MRI group, versus 5·0 per 1000 screenings in the mammography alone group [35]. Notably, in this study, only 59 % of participants accepted MRI screening, highlighting potential challenges with acceptability and implementation. Among those who declined, the interval cancer rate was 4·9 per 1000 screenings compared to 0·8 per 1000 screenings among those who underwent MRI. A second MRI study reported no interval cancers after over two years of follow-up among participants who had supplemental MRI after negative mammography or negative mammography and ultrasound, albeit in a small population sample [31].

Sensitivity and specificity values were inconsistently reported, hampering the ability to conduct further analysis. Where available, sensitivity was higher for supplementary imaging than for mammography alone, and specificity often exceeded 90 %, indicating reliable performance.

Quality assessment of the modelling studies revealed a potential risk of bias related to flow and timing. Delays between tests were common, likely due to logistical challenges such as limited imaging access, specialist expertise and costs. For example, median intervals between imaging tests ranged from 8 to 20 weeks across MRI studies [9,30,35], while the study by Kaiser et al. did not report the median interval between tests but excluded delays over two months to avoid misclassifying interval cancers [26]. Similar delays were observed in the BRAID study: 16 weeks (IQR 11–21) for ABUS and 19 weeks (IQR 13–25) for CEM, indicating systemic scheduling constraints [9].

Economic modelling studies produced mixed results. While MRI showed potential cost-effectiveness, particularly for younger women with dense breasts, results were highly sensitive to modelling assumptions. Risk-stratified screening approaches yielded inconsistent outcomes even for studies conducted for the same country and perspective [63,64], driven by substantial differences in QALY estimates.

4.1. Implications for practice and policy

Both MRI and CEM showed higher CDR compared to DBT, ABUS, and HHUS in individuals with dense breast tissue. Given their superior performance MRI, and potentially CEM, should be considered in future screening policy reviews for this population. Further research directly comparing MRI to CEM in women with dense breasts is needed, because current ongoing studies, including CMIST (completion expected in 2025) and C-MERIT (late 2026), assess CEM in screening contexts but do not offer head-to-head comparisons. Our economic evaluation also highlights the need for standardised models and context-specific analyses to support informed screening policy decisions.

MRI and CEM require different types of contrast media with distinct safety profiles. The risk of immediate adverse reactions to gadolinium-based contrast agent (GBCA, used in MRI) has been reported to be approximately 6–9 per 10,000 examinations [67], whereas for modern non-ionic, low-osmolality iodinated contrast (used in CEM) the risk of hypersensitivity reaction may occur in up to 1 % of patients [68]. The administration of either agent in a screening setting introduces a potential risk of harm that must be carefully weighed over and above the established potential harm of screening, such as overdiagnosis and overtreatment. Three studies on supplemental MRI screening reported adverse events related to vasovagal reactions or contrast extravasation. In the study by Gilbert et al., a higher rate of adverse reactions was observed in the CEM arm compared with the MRI arm which might be consistent with what would be expected in clinical practice [9].

4.2. Strengths and weaknesses

This review included both retrospective studies and those with randomised or paired designs, which may potentially introduce selection bias. To mitigate this, we excluded studies involving pre-selected high-risk populations, such as individuals with family history or prior breast cancer, ensuring our focus remained on average-risk individuals with dense breasts. Supplemental screening may be more feasible for individuals with extremely dense breasts, representing less than 10 % of the screening population, rather than for the broader group with dense and extremely dense tissue (nearly 50 % of the screening population). However, we did not evaluate whether supplemental imaging modalities are more effective for those with extremely dense breasts. Pooled estimates reflect relative differences in outcomes, rather than absolute detection values. Importantly, our review incorporated recent literature, including studies published up to November 2024, ensuring the inclusion of the most up-to-date evidence in this rapidly evolving field.

5. Conclusions

Standard mammography alone is insufficient for detecting breast cancer in individuals with dense breasts. While adjunctive modalities such as ABUS, HHUS, and DBT offer modest incremental improvements, they still miss many cancers. MRI substantially increases CDR, and emerging evidence suggests CEM may also be a valuable supplemental screening option. Overall, quality assessment revealed methodological variability, delays in imaging access, and underrepresentation of women with extremely dense breasts. To inform effective screening strategies, future research must address the current key evidence gaps, particularly the comparative effectiveness of CEM versus MRI and their cost-effectiveness.

CRediT authorship contribution statement

Sinéad N. Duggan: Writing – review & editing, Writing – original draft, Visualization, Methodology, Investigation, Data curation. Mohammad Azharuddin: Writing – review & editing, Writing – original draft, Visualization, Methodology, Investigation, Data curation. Rodolfo Hernández: Writing – review & editing, Writing – original draft, Supervision, Methodology, Investigation, Conceptualization. Clare Robertson: Writing – review & editing, Writing – original draft, Visualization, Methodology, Investigation, Data curation. David Cooper: Writing – review & editing, Visualization, Formal analysis. Emma McCall: Writing – review & editing, Validation, Investigation. Paul Manson: Writing – review & editing, Resources, Methodology. Gianni Virgili: Writing – review & editing, Supervision, Methodology. Mike Clarke: Writing – review & editing, Supervision, Methodology, Funding acquisition, Conceptualization. Shaun Treweek: Writing – review & editing, Supervision, Methodology, Funding acquisition, Conceptualization. Miriam Brazzelli: Writing – review & editing, Writing – original draft, Supervision, Project administration, Methodology, Funding acquisition, Conceptualization.

Ethical approval

Not applicable.

Data sharing

This is an evidence synthesis; all quantitative data are presented in the text or contained within tables, figures, and supplementary material. No new data suitable for data sharing have been created in the preparation of this synthesis. All queries should be submitted to the corresponding author for consideration.

Declaration of generative AI and AI-assisted technologies in the writing process

During the preparation of this work the authors used ChatGPT-4o to shorten sections of the manuscript and to prepare an initial draft of the summary to help meet the word count limit. AI was not used to generate new content. All original text was written by a human author, and the ChatGPT-generated summary was derived solely from human-written material. After using this tool/service, the final versions of the summary was reviewed by all authors and differs significantly from the initial ChatGTP-generated draft, and the authors take full responsibility for the content of the publication.

Funding source

This review was funded by the National Institute for Health and Care Research (NIHR) Evidence Synthesis Programme (project number NIHR164221), and commissioned by the United Kingdom National Screening Committee (NSC). The NIHR Evidence Synthesis Programme had no role in review design; in the collection, analysis, and interpretation of data; in the writing of the report; or in the decision to submit the article for publication. The UK NSC, as commissioners of this research, contributed to study design, and were part of the study Advisory Group who provided expert advice regarding interpretation of data and the current screening pathway. However, they had no role in the writing of this manuscript or in the decision to submit it for publication.

Declaration of competing interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Acknowledgements

The research reported in this manuscript was funded by the National Institute for Health and Care Research (NIHR) Evidence Synthesis Programme and commissioned by the United Kingdom National Screening Committee (UK NSC). The views and opinions expressed by the authors in this publication are those of the authors themselves and do not necessarily reflect those of the NIHR Evidence Synthesis Programme, the UK NSC, the NHS or the UK Department of Health and Social Care. We gratefully acknowledge Professor Fiona Gilbert (Professor of Radiology, NHS Cambridge University Hospitals) for providing data from the BRAID Trial ahead of its subsequent publication. We also thank the members of our Advisory Group for their clinical and policy insights, including Dr Cristina Visintin (Research Lead for UK National Screening Committee Research Methodology Group), Dr Rosalind Given-Wilson, (Consultant Radiologist/Honorary Professor, University of Warwick/Warick Medical School), and Professor Lesley Anderson (Professor of Health Data Science and Interdisciplinary Director for Health, Nutrition and Wellbeing, University of Aberdeen). Finally, we extend our sincere thanks to our patient partners, Ms Ruth Blacker-Burns and Ms Debra Dulake, for their valuable advice, time, and gracious support.

Footnotes

Appendix A

Supplementary data to this article can be found online at https://doi.org/10.1016/j.breast.2025.104668.

Appendix A. Supplementary data

The following is the Supplementary data to this article.

Multimedia component 1
mmc1.docx (506.2KB, docx)

References

  • 1.World Health Organization Breast Cancer. 2024 https://www.who.int/news-room/fact-sheets/detail/breast-cancer [Google Scholar]
  • 2.Cancer Research UK Cancer statistics for the UK. https://www.cancerresearchuk.org/health-professional/cancer-statistics-for-the-uk
  • 3.Mann R.M., Athanasiou A., Baltzer P.A.T., et al. Breast cancer screening in women with extremely dense breasts recommendations of the European society of breast imaging (EUSOBI) Eur Radiol. 2022;32(6):4036–4045. doi: 10.1007/s00330-022-08617-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.American College of Radiology ACR BI-RADS atlas, breast imaging reporting and data system 2013. 2013. https://www.acr.org/Clinical-Resources/Reporting-and-Data-Systems/Bi-Rads
  • 5.Sprague B.L., Kerlikowske K., Bowles E.J.A., et al. Trends in clinical breast density assessment from the breast cancer surveillance consortium. J Natl Cancer Inst. 2019;111(6):629–632. doi: 10.1093/jnci/djy210. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Edmonds C.E., O'Brien S.R., Conant E.F. Mammographic breast density: current assessment methods, clinical implications, and future directions. Semin Ultrasound CT MR. 2023;44(1):35–45. doi: 10.1053/j.sult.2022.11.001. [DOI] [PubMed] [Google Scholar]
  • 7.Hussein H., Abbas E., Keshavarzi S., et al. Supplemental breast cancer screening in women with dense breasts and negative mammography: a systematic review and meta-analysis. Radiology. 2023;306(3) doi: 10.1148/radiol.221785. [DOI] [PubMed] [Google Scholar]
  • 8.Marcon M., Fuchsjäger M., Clauser P., Mann R. ESR essentials: screening for breast cancer - general recommendations by EUSOBI. Eur Radiol. 2024;34(10):6348–6357. doi: 10.1007/s00330-024-10740-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Gilbert F.J., Payne N.R., Allajbeu I., et al. Comparison of supplemental breast cancer imaging techniques—interim results from the BRAID randomised controlled trial. Lancet. 2025;405:1935–1944. doi: 10.1016/S0140-6736(25)00582-3. 10493. [DOI] [PubMed] [Google Scholar]
  • 10.Higgins J., Thomas J., Chandler J., et al. Cochrane handbook for systematic reviews of interventions. 2024. www.training.cochrane.org/handbook (updated August 2024)
  • 11.Page M.J., McKenzie J.E., Bossuyt P.M., et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. Br Med J. 2021;372 doi: 10.1136/bmj.n71. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Duggan S., Clarke M., Brazzelli M., et al. Risk-adapted breast imaging in population breast cancer screening programmes. 2024. https://www.crd.york.ac.uk/PROSPERO/view/CRD42024550250
  • 13.Whiting P.F., Rutjes A.W.S., Westwood M.E., et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155(8):529–536. doi: 10.7326/0003-4819-155-8-201110180-00009. [DOI] [PubMed] [Google Scholar]
  • 14.Yang B., Mallett S., Takwoingi Y., et al. QUADAS-C: a tool for assessing risk of bias in comparative diagnostic accuracy studies. Ann Intern Med. 2021;174(11):1592–1599. doi: 10.7326/M21-2234. [DOI] [PubMed] [Google Scholar]
  • 15.Lewis S., Clarke M. Forest plots: trying to see the wood and the trees. Br Med J. 2001;322(7300):1479–1480. doi: 10.1136/bmj.322.7300.1479. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Higgins J.P., Thompson S.G., Deeks J.J., Altman D.G. Measuring inconsistency in meta-analyses. Br Med J. 2003;327(7414):557–560. doi: 10.1136/bmj.327.7414.557. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.StataCorp. Stata statistical software: release vol. 18. College Station, TX: StataCorp LLC; 2023.
  • 18.Kwon M.-R., Choi J.S., Lee M.Y., et al. Screening outcomes of supplemental automated breast US in Asian women with dense and nondense breasts. Radiology. 2023;307(4) doi: 10.1148/radiol.222435. [DOI] [PubMed] [Google Scholar]
  • 19.Nakamura A., Ohnuki K., Takahashi H., et al. The effects of breast density on the benefits of mammograms with adjunctive ultrasonography in breast screening. Breast Cancer. 2024;31(2):228–233. doi: 10.1007/s12282-023-01525-7. [DOI] [PubMed] [Google Scholar]
  • 20.Ren W., Yan H., Zhao X., et al. Integration of handheld ultrasound or automated breast ultrasound among women with negative mammographic screening findings: a multi-center population-based study in China. Acad Radiol. 2023;30:S114–S126. doi: 10.1016/j.acra.2023.02.026. (Supplement 2) [DOI] [PubMed] [Google Scholar]
  • 21.Lee S.E., Yoon J.H., Son N.-H., Han K., Moon H.J. Screening in patients with dense breasts: comparison of mammography, artificial intelligence, and supplementary ultrasound. AJR Am J Roentgenol. 2024;222(1) doi: 10.2214/AJR.23.29655. [DOI] [PubMed] [Google Scholar]
  • 22.Pulido-Carmona C., Romero-Martín S., Raya-Povedano J.L., et al. Interval cancer in the Córdoba breast tomosynthesis screening trial (CBTST): comparison of digital breast tomosynthesis plus digital mammography to digital mammography alone. Eur Radiol. 2024 doi: 10.1007/s00330-023-10546-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Rani V.R., Reddy B.N. Diagnostic performance in detecting breast cancer on combined mammography and ultrasound. J Cardiovasc Dis Res. 2023;14(5):1649–1652. [Google Scholar]
  • 24.Olinder J., Johnson K., Akesson A., Fornvik D., Zackrisson S. Impact of breast density on diagnostic accuracy in digital breast tomosynthesis versus digital mammography: results from a European screening trial. Breast Cancer Res. 2023;25(1):116. doi: 10.1186/s13058-023-01712-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Ha S.M., Jang M.-J., Youn I., et al. Screening outcomes of mammography with AI in dense breasts: a comparative study with supplemental screening US. Radiology. 2024;312(1) doi: 10.1148/radiol.233391. [DOI] [PubMed] [Google Scholar]
  • 26.Kaiser C.G.N., Wilhelm T., Walter S., Singer S., Keller E., Baltzer P.A.T. Cancer detection rate of breast-MR in supplemental screening after negative mammography in women with dense breasts. Preliminary results of the MA-DETECT-Study after 200 participants. Eur J Radiol. 2024;176 doi: 10.1016/j.ejrad.2024.111476. [DOI] [PubMed] [Google Scholar]
  • 27.Osteras B.H., Martinsen A.C.T., Gullien R., Skaane P. Digital mammography versus breast tomosynthesis: impact of breast density on diagnostic performance in population-based screening. Radiology. 2019;293(1):60–68. doi: 10.1148/radiol.2019190425. [DOI] [PubMed] [Google Scholar]
  • 28.Buchberger W., Geiger-Gritsch S., Knapp R., Gautsch K., Oberaigner W. Combined screening with mammography and ultrasound in a population-based screening program. Eur J Radiol. 2018;101:24–29. doi: 10.1016/j.ejrad.2018.01.022. [DOI] [PubMed] [Google Scholar]
  • 29.Wilczek B., Wilczek H.E., Rasouliyan L., Leifland K. Adding 3D automated breast ultrasound to mammography screening in women with heterogeneously and extremely dense breasts: report from a hospital-based, high-volume, single-center breast cancer screening program. Eur J Radiol. 2016;85(9):1554–1563. doi: 10.1016/j.ejrad.2016.06.004. [DOI] [PubMed] [Google Scholar]
  • 30.Veenhuizen S.G.A., de Lange S.V., Bakker M.F., et al. Supplemental breast MRI for women with extremely dense breasts: results of the second screening round of the DENSE trial. Radiology. 2021;299(2):278–286. doi: 10.1148/radiol.2021203633. [DOI] [PubMed] [Google Scholar]
  • 31.Kuhl C.K., Strobel K., Bieling H., Leutner C., Schild H.H., Schrading S. Supplemental breast MR imaging screening of women with average risk of breast cancer. Radiology. 2017;283(2):361–370. doi: 10.1148/radiol.2016161444. [DOI] [PubMed] [Google Scholar]
  • 32.Gatta G., Cappabianca S., La Forgia D., et al. Second-generation 3D automated breast ultrasonography (Prone ABUS) for dense breast cancer screening integrated to mammography: effectiveness, performance and detection rates. J Personalized Med. 2021;11(9) doi: 10.3390/jpm11090875. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Bernardi D., Macaskill P., Pellegrini M., et al. Breast cancer screening with tomosynthesis (3D mammography) with acquired or synthetic 2D mammography compared with 2D mammography alone (STORM-2): a population-based prospective study. Lancet Oncol. 2016;17(8):1105–1113. doi: 10.1016/S1470-2045(16)30101-2. [DOI] [PubMed] [Google Scholar]
  • 34.Pattacini P., Nitrosi A., Giorgi Rossi P., et al. A randomized trial comparing breast cancer incidence and interval cancers after tomosynthesis plus mammography versus mammography alone. Radiology. 2022;303(2):256–266. doi: 10.1148/radiol.211132. [DOI] [PubMed] [Google Scholar]
  • 35.Bakker M.F., de Lange S.V., Pijnappel R.M., et al. Supplemental MRI screening for women with extremely dense breast tissue. N Engl J Med. 2019;381(22):2091–2102. doi: 10.1056/NEJMoa1903986. [DOI] [PubMed] [Google Scholar]
  • 36.Upadhyay N., Soneji N., Stewart V., Ralleigh G. The effect of the addition of tomosynthesis to digital mammography on reader recall rate and reader confidence in the UK prevalent screening round. Clin Radiol. 2018;73(8):744–749. doi: 10.1016/j.crad.2018.03.013. [DOI] [PubMed] [Google Scholar]
  • 37.Tagliafico A.S., Calabrese M., Mariscotti G., et al. Adjunct screening with tomosynthesis or ultrasound in women with mammography-negative dense breasts: interim report of a prospective comparative trial. J Clin Oncol. 2016;34(16):1882–1888. doi: 10.1200/JCO.2015.63.4147. [DOI] [PubMed] [Google Scholar]
  • 38.Johnson K., Zackrisson S., Rosso A., et al. Tumor characteristics and molecular subtypes in breast cancer screening with digital breast tomosynthesis: the Malmö breast tomosynthesis screening trial. Radiology. 2019;293(2):273–281. doi: 10.1148/radiol.2019190132. [DOI] [PubMed] [Google Scholar]
  • 39.McDonald E.S., McCarthy A.M., Akhtar A.L., Synnestvedt M.B., Schnall M., Conant E.F. Baseline screening mammography: performance of full-field digital mammography versus digital breast tomosynthesis. AJR Am J Roentgenol. 2015;205(5):1143–1148. doi: 10.2214/AJR.15.14406. [DOI] [PubMed] [Google Scholar]
  • 40.McDonald E.S., Oustimov A., Weinstein S.P., Synnestvedt M.B., Schnall M., Conant E.F. Effectiveness of digital breast tomosynthesis compared with digital mammography: outcomes analysis from 3 years of breast cancer screening. JAMA Oncol. 2016;2(6):737–743. doi: 10.1001/jamaoncol.2015.5536. [DOI] [PubMed] [Google Scholar]
  • 41.Freer P.E., Riegert J., Eisenmenger L., et al. Clinical implementation of synthesized mammography with digital breast tomosynthesis in a routine clinical practice. Breast Cancer Res Treat. 2017;166(2):501–509. doi: 10.1007/s10549-017-4431-1. [DOI] [PubMed] [Google Scholar]
  • 42.Durand M.A., Friedewald S.M., Plecha D.M., et al. False-negative rates of breast cancer screening with and without digital breast tomosynthesis. Radiology. 2021;298(2):296–305. doi: 10.1148/radiol.2020202858. [DOI] [PubMed] [Google Scholar]
  • 43.Conant E.F., Beaber E.F., Sprague B.L., et al. Breast cancer screening using tomosynthesis in combination with digital mammography compared to digital mammography alone: a cohort study within the PROSPR consortium. Breast Cancer Res Treat. 2016;156(1):109–116. doi: 10.1007/s10549-016-3695-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 44.Rose S.L., Shisler J.L. Tomosynthesis impact on breast cancer screening in patients younger than 50 years old. AJR Am J Roentgenol. 2018;210(6):1401–1404. doi: 10.2214/AJR.17.18839. [DOI] [PubMed] [Google Scholar]
  • 45.Starikov A., Drotman M., Hentel K., Katzen J., Min R.J., Arleo E.K. 2D mammography, digital breast tomosynthesis, and ultrasound: which should be used for the different breast densities in breast cancer screening? Clin Imag. 2016;40(1):68–71. doi: 10.1016/j.clinimag.2015.10.001. [DOI] [PubMed] [Google Scholar]
  • 46.Brem R.F., Tabar L., Duffy S.W., et al. Assessing improvement in detection of breast cancer with three-dimensional automated breast US in women with dense breast tissue: the SomoInsight study. Radiology. 2015;274(3):663–673. doi: 10.1148/radiol.14132832. [DOI] [PubMed] [Google Scholar]
  • 47.Pang J.X., Newsome J., Sun M., et al. Impact of switching from digital mammography to tomosynthesis plus digital mammography on breast cancer screening in Alberta, Canada. J Med Screen. 2022;29(1):38–43. doi: 10.1177/09691413211032265. [DOI] [PubMed] [Google Scholar]
  • 48.Stepanek T., Constantinou N., Marshall H., et al. Changes in the utilization of the BI-RADS category 3 assessment in recalled patients before and after the implementation of screening digital breast tomosynthesis. Acad Radiol. 2019;26(11):1515–1525. doi: 10.1016/j.acra.2018.12.020. [DOI] [PubMed] [Google Scholar]
  • 49.Chen S.Q., Huang M., Shen Y.Y., Liu C.L., Xu C.X. Application of abbreviated protocol of magnetic resonance imaging for breast cancer screening in dense breast tissue. Acad Radiol. 2017;24(3):316–320. doi: 10.1016/j.acra.2016.10.003. [DOI] [PubMed] [Google Scholar]
  • 50.Ban K., Tsunoda H., Togashi S., et al. Breast cancer screening using digital breast tomosynthesis compared to digital mammography alone for Japanese women. Breast Cancer. 2021;28(2):459–464. doi: 10.1007/s12282-020-01180-2. [DOI] [PubMed] [Google Scholar]
  • 51.Chang J.M., Koo H.R., Moon W.K. Radiologist-performed hand-held ultrasound screening at average risk of breast cancer: results from a single health screening center. Acta Radiol. 2015;56(6):652–658. doi: 10.1177/0284185114538252. [DOI] [PubMed] [Google Scholar]
  • 52.Harada-Shoji N., Suzuki A., Ishida T., et al. Evaluation of adjunctive ultrasonography for breast cancer detection among women aged 40-49 years with varying breast density undergoing screening mammography: a secondary analysis of a randomized clinical trial. JAMA Netw Open. 2021;4(8) doi: 10.1001/jamanetworkopen.2021.21505. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 53.Blankenburg M., Sanchez-Collado I., Soyemi B.O., et al. Economic evaluation of supplemental breast cancer screening modalities to mammography or digital breast tomosynthesis in women with heterogeneously and extremely dense breasts and average or intermediate breast cancer risk in US healthcare. J Med Econ. 2023;26(1):850–861. doi: 10.1080/13696998.2023.2222035. [DOI] [PubMed] [Google Scholar]
  • 54.Lee C.I., Cevik M., Alagoz O., et al. Comparative effectiveness of combined digital mammography and tomosynthesis screening for women with dense breasts. Radiology. 2015;274(3):772–780. doi: 10.1148/radiol.14141237. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 55.Sprague B.L., Stout N.K., Schechter C., et al. Benefits, harms, and cost-effectiveness of supplemental ultrasonography screening for women with dense breasts. Ann Intern Med. 2015;162(3):157–166. doi: 10.7326/M14-0692. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 56.Geuzinge H., Bakker M.F., Heijnsdijk E.A.M., et al. Cost-effectiveness of magnetic resonance imaging screening for women with extremely dense breast tissue. J Natl Cancer Inst. 2021;113(11):1476–1483. doi: 10.1093/jnci/djab119. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 57.Wang J., Greuter M.J.W., Vermeulen K.M., et al. Cost-effectiveness of abbreviated-protocol MRI screening for women with mammographically dense breasts in a national breast cancer screening program. Breast. 2022;61:58–65. doi: 10.1016/j.breast.2021.12.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 58.Wang J., Phi X.A., Greuter M.J.W., et al. The cost-effectiveness of digital breast tomosynthesis in a population breast cancer screening program. Eur Radiol. 2020;30(10):5437–5445. doi: 10.1007/s00330-020-06812-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 59.Tollens F., Baltzer P.A.T., Dietzel M., et al. Cost-effectiveness of MR-Mammography in breast cancer screening of women with extremely dense breasts after two rounds of screening. Front Oncol. 2021;11 doi: 10.3389/fonc.2021.724543. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 60.Couto H.L., Gargano L.P., de Oliveira V.M., et al. Cost-effectiveness analysis of digital breast tomosynthesis added to synthetic mammography in breast cancer screening in Brazil. PharmacoEconomics - Open. 2024;8:403–416. doi: 10.1007/s41669-023-00470-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 61.Ontario Health . Ontario Health; Canada: 2023. Supplemental screening as an adjunct to mammography for breast cancer screening in people with dense breasts: a health technology assessment. [PMC free article] [PubMed] [Google Scholar]
  • 62.Kaiser C.G., Dietzel M., Vag T., Froelich M.F. Cost-effectiveness of MR-mammography vs. conventional mammography in screening patients at intermediate risk of breast cancer - a model-based economic evaluation. Eur J Radiol. 2021;136 doi: 10.1016/j.ejrad.2020.109355. [DOI] [PubMed] [Google Scholar]
  • 63.Gray E., Donten A., Karssemeijer N., et al. Evaluation of a stratified national breast screening program in the United Kingdom: an early model-based cost-effectiveness analysis. Value Health. 2017;20(8):1100–1109. doi: 10.1016/j.jval.2017.04.012. [DOI] [PubMed] [Google Scholar]
  • 64.Hill H., Kearns B., Pashayan N., et al. The cost-effectiveness of risk-stratified breast cancer screening in the UK. Br J Cancer. 2023;129(11):1801–1809. doi: 10.1038/s41416-023-02461-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 65.NHS England Breast screening programme: standards. 2017. https://www.gov.uk/government/publications/breast-screening-consolidated-programme-standards
  • 66.Burnside E.S., Vulkan D., Blanks R.G., Duffy S.W. Association between screening mammography recall rate and interval cancers in the UK breast cancer service screening program: a cohort study. Radiology. 2018;288(1):47–54. doi: 10.1148/radiol.2018171539. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 67.Royal College of Radiologists . Royal College of Radiologists; London: 2019. Guidance on gadolinium-based contrast agent administration to adult patients.https://www.rcr.ac.uk/our-services/all-our-publications/clinical-radiology-publications/guidance-on-gadolinium-based-contrast-agent-administration-to-adult-patients/ [Google Scholar]
  • 68.Royal Australian and New Zealand College of Radiologists . RANZCR; Sydney: 2018. Iodinated contrast media guideline.https://www.ranzcr.com/whats-on/news-media/iodinated-contrast-media-guideline-update [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Multimedia component 1
mmc1.docx (506.2KB, docx)

Articles from The Breast : Official Journal of the European Society of Mastology are provided here courtesy of Elsevier

RESOURCES