Effect of different restoration methods on fracture resistance.

Restoration timing Restoration method Mean fracture load (N) P
Immediate Full crown 2543.21 ± 389.56
Onlay 2167.89 ± 321.45 .002
Occlusal veneer 2089.34 ± 298.76 .003
Early Full crown 2215.67 ± 356.78
Onlay 1987.45 ± 312.67 .015
Occlusal veneer 1895.67 ± 289.45 .021
Delayed Full crown 1895.67 ± 345.67
Onlay 1689.34 ± 298.76 .034
Occlusal veneer 1621.56 ± 278.90 .042